Global Cerebral Ischemia in a Beagle Dog (비글견에서 발생한 전반적 대뇌허혈)

  • Choi, Ho-Jung;Choi, Soo-Young;An, Ji-Young;O, I-Se;Jeong, Seong-Mok;Cho, Sung-Whan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.26 no.1
    • /
    • pp.104-108
    • /
    • 2009
  • Global cerebral ischemia occurs commonly in patients who have a variety of clinical conditions including cardiac arrest and shock. Cerebral ischemia results in a rapid depletion of energy stores that triggers resulting in excitotoxic death. Imaging studies of the brain with computed tomography(CT) or magnetic resonance imaging(MRI) are necessary to confirm the clinical neurolocalization, identify any associated mass effect, and rule out other causes of focal brain disorders. Cardiopulmonary arrest was occurred by propofol anesthesia in a 1 year old, intact female Beagle dog. After successful cardiopulmonary resuscitation was performed within 5 minutes, clinical signs such as vocalization, paddling, opisthotonus and seizure were represented. At the 12th day, CT and MRI examinations of the brain were performed to evaluate the brain. After euthanasia, histopathologic examination was performed. On transverse image of CT, lesions appeared as a hypodense in the right dorsal surface of the frontal lobe and level of optic canal, and dorsomedial surface of occipital lobe of cerebrum. No contrast enhancement was represented following intravenous contrast administration. On MR images of brain, the lesions were seen as a hyperintense on T2-weighted(T2W) images and a isointense or mild hypointense on T1-weighted(T1W) images. Hyperintense lesions both T2W and T1W images were observed at the surrounding cerebral sulcus. There was no significant signal changes on contrast T1WI. Histopathologic examination after euthanasia revealed that the lesion was necrosis of the cerebral cortex caused by cerebral ischemia.

Evaluation of Accuracy on Hitchcoke CT/angio localization system using QA head phantom (QA용 두부 팬톰을 이용한 Hitchcoke CT 및 혈관조영 정위적 시스템에 대한 정확도 평가)

  • 김성현;서태석;윤세철;손병철;김문찬;신경섭
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • In order to provide complementary image data, CT(computed tomography), MR(magnetic resonance) and angiography have been used in the field of Stereotactic Radiosurgery(SRS) and neurosurgery. The aim of this work is to develop 3-D stereotactic localization system in order to determine the precise shape, size and location of the lesion in the brain in the field of Stereotactic Radiosurgery(SRS) and neurosurgery using multi-image modality and multi purpose QA phantom. In order to obtain accurate position of a target, Hitchcoke stereotactic frame and CT/angiography localizers were rigidly attached to the phantom with nine targets dispersed in 3-D space. The algorithms to obtain a 3-D stereotactic coordinates of the target have been developed using the images of the geometrical phantom which were taken by CT/angiography. Positions of targets computed by our algorithms were compared to the absolute position assigned in the phantom. Outlines of targets on each CT image were superimposed each other on angiography images. A spatial mean distance errors were 1.02${\pm}$0.17mm for CT with a 512${\times}$512 matrix and 2mm slice thickness, 0.41${\pm}$0.05mm for angiogra- phy localization. The resulting accuracy in the target localization suggests that the developed system has enough Qualification for Stereotactic Radiosurgery (SRS).

  • PDF

Evaluation of Automatic Image Segmentation for 3D Volume Measurement of Liver and Spleen Based on 3D Region-growing Algorithm using Animal Phantom (간과 비장의 체적을 구하기 위한 3차원 영역 확장 기반 자동 영상 분할 알고리즘의 동물팬텀을 이용한 성능검증)

  • Kim, Jin-Sung;Cho, June-Sik;Shin, Kyung-Sook;Kim, Jin-Hwan;Jeon, Ho-Sang;Cho, Gyu-Seong
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.178-185
    • /
    • 2008
  • Living donor liver transplantation is increasingly performed as an alternative to cadaveric transplantation. Preoperative screening of the donor candidates is very important. The quality, size, and vascular and biliary anatomy of the liver are best assessed with magnetic resonance (MR) imaging or computed tomography (CT). In particular, the volume of the potential graft must be measured to ensure sufficient liver function after surgery. Preoperative liver segmentation has proved useful for measuring the graft volume before living donor liver transplantations in previous studies. In these studies, the liver segments were manually delineated on each image section. The delineated areas were multiplied by the section thickness to obtain volumes and summed to obtain the total volume of the liver segments. This process is tedious and time consuming. To compensate for this problem, automatic segmentation techniques have been proposed with multiplanar CT images. These methods involve the use of sequences of thresholding, morphologic operations (ie, mathematic operations, such as image dilation, erosion, opening, and closing, that are based on shape), and 3D region growing methods. These techniques are complex but require a few computation times. We made a phantom for volume measurement with pig and evaluated actual volume of spleen and liver of phantom. The results represent that our semiautomatic volume measurement algorithm shows a good accuracy and repeatability with actual volume of phantom and possibility for clinical use to assist physician as a measuring tool.

  • PDF

A Study on the Deviation of Cluster Based on Template Images of Korean Children's Brain SPECT Image Using the Statistical Parametic Mapping (통계적 파라미터 뇌지도작성을 이용한 국내 어린이 뇌 SPECT영상의 표준틀영상에 따른 화소덩어리의 편차연구)

  • 신동호;박성옥;권수일;조철우;윤석남;이명훈;신동오
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.45-53
    • /
    • 2004
  • SPM has been widely applied for comparison studios of the functional image data among groups of patients or individuals under different conditions and these images are from people ranging from children to adults. However, the analysis of children's brain images by using SPM can make children's brain images normalized to an adult's template image and this can result in some errors. So this study created the children's mean MR images based on the Magnetic Resonance Images of 36 normal children (age: 2~6, average age: 4.36, SD age: 1.41, M/F: 17/19), and the children's mean SPECT images by using SPECT images of 13 normal children (age: 2~6, average age: 4.80, SD age: 1.17, M/F: 10/3). We created the Korean children's brain template image, based on those mean images, and then we compared between the positions of the clusters, based on the blood flow, by normalizing ADHD children's SPECT image to Korean children's template image and SPM adult's template image. As a result of the analysis, the variation of the cluster positions was found to be a maximum of 25 ㎜. Therefore, we should be aware that we need to consider the template image and the p-value when we analyze the chlidren's brain image by using SPM.

  • PDF

A Study of Whiter Matter Fiber Tractography in Young Internet Addiction Disorder using a Brain Diffusion Tensor Magnetic Resonance Imaging (뇌 확산텐서 자기공명영상을 이용한 청소년 인터넷 중독자의 백질 섬유로에 관한 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.7-13
    • /
    • 2016
  • The goal of this study is to investigate corpus callosum and both internal capsule changes with the internet addiction disorder compared to control group using MR diffusion tensor imaging. A total of 22 teenager volunteers who had 10 high-risk group with internet addiction and 12 normal control group were conducted for this study. Imaging was conducted on a 3 T using a EPI sequence. Image evaluation was analysed of the FA, ADC($10^{-3}mm^2/s$), length(mm). We did select ROI for image tracking on corpus callosum of 5 and including 2(internal capsule). The data from these ROIs were compared statistically among the groups using independent t-test, correlation coefficient. There were significant inter-group differences(p<0.05) among FA, ADC($10^{-3}mm^2/s$) and length(mm). And also significantly negative correlations were fond between FA values of corpus callosum and IAD scale(p=0.000). DTI was shown significant changes of FA and ADC, LNF values in IAD compared to control group. Therefore, our results may provided clinical information for brain wite matter functions.

Proton Magnetic Resonance Chemical Shift Imaging(1H-CSI)-directed Stereotactic Brain Biopsy (양성자 화학적 이동영상기법(1H-CSI)을 이용한 정위적 뇌생검)

  • Chang, Kyung-Sool;Son, Byung-Chul;Kim, Moon-Chan;Choi, Byung-Gil;Kim, Euy-Neying;Kim, Bum-Soo;Choe, Bo-Young;Baik, Hyun-Man;Hong, Yong-Kil;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1606-1611
    • /
    • 2000
  • Objective : To obtain more reliable sample in stereotactic biopsy, authors adopted proton chemical shift imaging ($^1H$-CSI)-directed biopsy. Until now, proton single voxel spectroscopy($^1H$-SVS) technique has been reported as a technique using metabolic information in stereotactic biopsy. The authors performed $^1H$-CSI with a stereotactic headframe in place and evaluated the pathologic results obtained from local metabolic information through $^1H$-CSI. Methods : $^1H$ CSI-directed stereotactic biopsy was performed in four patients. $^1H$-CSI and conventional Gd-enhancement stereotactic MRI was done simultaneously after application of the stereotatic frame. After reconstruction of metabolic maps of NAA/Cr, Cho/Cr, and Lactate/Cr ratios, the focal areas of increased Cho/Cr ratios and decreased NAA/Cr ratios were selected for target sites in the MR images Results : There was no difficulty in performing $^1H$-CSI with the stereotactic headframe in place. In pathologic examinations, the samples taken in area of increased Cho/Cr ratios and decreased NAA/Cr ratios showed the features of increased cellularity, mitoses and cellular atypism, thus facilitated the diagnosis. The pathologic samples taken from the area of increased Lactate/Cr ratios showed prominent feature of necrosis. Conclusion : $^1H$-CSI was feasible with stereotactic head frame in place. The final pathologic results obtained in our samples were concordant with the local metabolic informations from $^1H$-CSI. Authors believe that $^1H$ CSI-directed stereotactic biopsy may provide us advantages in obtaining more reliable tissue specimen in stereotactic biopsy.

  • PDF

MD로써 기대하는 PhD의 역할과 현실

  • 정태섭
    • Proceedings of the KSMRM Conference
    • /
    • 1999.11a
    • /
    • pp.69-71
    • /
    • 1999
  • 최근 한국 의학의 발전은 전체 한국의 선진화를 선도하다고 보기에는 힘드리만 최소한 국제무대에의 진출은 괄목할만한 발전을 보이고 있다. 최근에 들어 국내 방사선영상과련 학회의 발전은 날로 비약적인 추세를 보이고 있다. 일례로 대한방사선의학회는 본 저자가 전공의 하던 1980년도 초기만 해도 호텔의 큰 홀 한 개만 빌려서 하루만 해도 넉넉하게 진행되었다. 그러나 최근의 학회사정은 대형호텔 1개층 통째로 빌리고 3일간 진행해도 여유가 없을 정도이며 더욱이 추계학회는 지방에서 유치할만한 공간이 부족하여 이제는 없어져야할 지경에 이러렀다. 그뿐 아니라 대한 자기공명의과학회를 포함한 각종 학회가 이제 그 규모를 더해가고 있어. 대한민국에 있어서 진단 방사선영역의 의학은 급속히 발전하여 RSNA, ISMRM등에서도 세계 발표순위가 4-5위권을 다투게 되었다. 이러한 발전은 양적인 발전이 우세하여 주로 임상연구에 기반을 두고 있는데 이 자체로는 장기적인 발전에 한계점이 있으므로 앞으로는 기초과학연구에 기초한 질적 발전을 같이 추구하여야만 균형있는 성장을 기대할 수 있겠다. 이러한 기존의 구성에 최근 급격한 변화를 주도하는 학문이 MRI부분이 되며 이 분야를 연구하는 PhD 들의 역할이 크게 대두되고 있다. 현재 국내에도 초기 단계이지만 MRI를 생산하고 있으며 PhD들의 활동이 성장단계에 접어들었다고 할수 있다. 과거 우리의 NRI역사에서는 금성사 MR기계처럼 육성되기 전에 시들며 노력하던 기술진이 흩어져야 했던 어두운 기억이 있다. 이러한 시점에서 우리의 힘들었던 과거를 돌이켜보며 또 하나의 기초부분이 육성되 수 있도록 서로가 격려하며 협조하여야 될 것으로 생각되어 다음과 같이 요약을 하였다. 소기관으로는 세포 막, 미토콘드리아 (mitochondria), endoplasmic reticulum, Golgi 체, lysosome, peroxisome 그리고 세포질등이 있으며, 이들중에서 lysosomes, peroxisomes, 그리고 미토콘드리아가 특정한 유전성 백질질환에 중요한 역할을 하는 것이 밝혀졌다. 이러한 질환들은 최소한 각 소기관에 의한 질환군으로 분류될 수 있다.SXR이 ER의 transactivation 효과를 약간 촉진한 반면 MDA-MB-231세포는 SXR을 제외한 CAR와 PPAR${\gamma}$에 의해 ER의 transactivation 효과가 약간 증가되는 경향을 보였다. 이러한 결과는 유방암세포에서는 CAR, SXR, PPAR${\gamma}$과 같은 xenobiotic nuclear receptor에 의한 ER transactivation 효과가 간암세포와는 다르게 나타나며, 유방암의 종류에 따라서 endogenous CAR, SXR, PPAR${\gamma}$수용체가 다르게 발현됨으로써 이들에 대한 반응이 서로 상이한 특징을 나타낼 수 있을 것으로 사료된다. 따라서 estrogen receptor에 의해 매개되는 estrogn의 전사활성조절기전이 표적세포에 따라 다른 경로를 포함 할 수 있음을 시사한다.서 흡착 능력이 우수하게 나타났으며, 황화수소는 펄라이트, 왕겨, 소나무수피에서 상대적으로 우수한 것으로 나타났으며, 혼합충전재는 암모니아의 경우 코코넛과 펄라이트의 비율이 7:3인 혼합 재료 3번과 소나무수피와 펄라이트의 비율이 7:3인 혼합 재료 6번에서 다른 혼합 재료에 비하여 우수한 것으

  • PDF

3-Dimensional Computed Tomography of Atlantoaxial Instability in Three Dogs (개에서 컴퓨터단층영상의 3차원 재구성을 통한 환축추골 아탈구 진단 3례)

  • Ahn, Se-Joon;Choi, Soo-Young;Lim, Soo-Ji;An, Ji-Young;Lee, In;Kwon, Young-Hang;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.26 no.5
    • /
    • pp.490-494
    • /
    • 2009
  • A 2-year-old Maltese and a 5-month-old Yorkshire terrier were presented with ataxia. Tetraparesis was observed in a 9-year -old Yorkshire terrier. The localizations of the lesions suggested brain or cervical spinal cord by the neurological examination, and the following images was achieved: radiography, axial images of computed tomography (CT), reconstruction image of CT such as multi-planar reformation(MPR) and 3-dimensional(3D) reconstruction and magnetic resonance imaging (MRI). On radiography, the misalignment between atlas (C1) and axis (C2), absent dens of axis, and increased space between the dorsal arch of C1 and spinous process of C2 were found. The discontinuation between dens and body of C2 was identified through axial CT images, and the fragmentation of dens separated from axis was observed through MPR and 3D image in all case. The hyperintense lesions and the spinal cord compression on T2-weighted MR images were represented in a dog with tetraparesis, the others represented only spinal cord compression. Three dogs were diagnosed as atlantoaxial instability (AAI) by dens fracture of C2. The dog with tetraparesis was euthanized due to guarded prognosis. The others were recovered completely. It is difficult to differentiate dens fracture of C2 from abnormal dens such as agenesis and hypoplasia. We thought that CT is very useful to evaluate the dens of C2 and differentiate the causes of AAI, and the reconstruction images of CT such as MPR and 3D make the translation of the fragmented dens or axis of AAI more precisely evaluate.

Lumbar Herniated Disc Resorption of 78 Patients after Korean Medicine Treatment (요추 추간판 탈출증 환자 78명의 한방치료 후 디스크 재흡수 증례 보고)

  • Jung, Bum-Hwan;Jo, Joo-Hyun;Yoon, Yong-Il;Park, Sang-won;Kim, Sung-Moon;Go, Ung;Jung, Jin-soo;Kim, Jung-Hoon;Huh, Suk-Won;Kim, Ji-Won;Kim, Moon-Hwi
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.26 no.1
    • /
    • pp.87-93
    • /
    • 2016
  • Objectives To analyze the resorption of herniated lumbar intervertebral disc on MRI in patients who were treated with Korean Medicine. Methods 78 patients with lumbar disc herniation were included, 47 males and 32 females. Patients' diagnosis was based on magnetic resonance imaging (MRI). All of the patients were only treated with Korean Medicine for 6 months treatment, and underwent MRI examination twice, pre-treatment and post-treatment. MR images were assessed by reduction in diameter of T2-weighted image between pre-treatment and post-treatment, and analyzed by differences in sex, age and disc type. Results 91.2% (71 people) of total patients had extrusion type. Korean medicine treatment reduced lumbar disc herniation diameter of all the patients from 7.11 mm to 3.67 mm on average (p<0.001). The reduction of diameter in the male group was 3.52 mm on average. The reduction of diameter in the female group was 3.32 mm on average. The reduction of diameter was 3.28 mm in the group below age 29, 3.88 mm in the 30~39 age group, 3.39 mm in the 40~49 age group, and 2.71 mm in the above 50 age group on average. Conclusions The MRI results suggest that lumbar herniated disc can resorb with Korean Medicine treatment. The likelihood of lumbar disc resorption was higher at extrusion type. but there was not a significant difference between the sexes and between ages.

Analysis of Images According to the Fluid Velocity in Time-of-Flight Magnetic Resonance Angiography, and Contrast Enhancement Angiography

  • Kim, Eng-Chan;Heo, Yeong-Cheol;Cho, Jae-Hwan;Lee, Hyun-Jeong;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.185-191
    • /
    • 2014
  • In this study we evaluated that flow rate changes affect the (time of flight) TOF image and contrast-enhanced (CE) in a three-dimensional TOF angiography. We used a 3.0T MR System, a nonpulsatile flow rate model. Saline was used as a fluid injected at a flow rate of 11.4 cm/sec by auto injector. The fluid signal strength, phantom body signal strength and background signal strength were measured at 1, 5, 10, 15, 20 and 25-th cross-section in the experienced images and then they were used to determine signal-to-noise ratio and contrast-to-noise ratio. The inlet, middle and outlet length were measured using coronal images obtained through the maximum intensity projection method. As a result, the length of inner cavity was 2.66 mm with no difference among the inlet, middle and outlet length. We also could know that the magnification rate is 49-55.6% in inlet part, 49-59% in middle part and 49-59% in outlet part, and so the image is generally larger than in the actual measurement. Signal-to-noise ratio and contrast-to-noise ratio were negatively correlated with the fluid velocity and so we could see that signal-to-noise ratio and contrast-to-noise ratio are reduced by faster fluid velocity. Signal-to-noise ratio was 42.2-52.5 in 5-25th section and contrast-to-noise ratio was from 34.0-46.1 also not different, but there was a difference in the 1st section. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s. Consequently, 3D TOF MRA tests show that the faster fluid velocity decreases the signal-to-noise ratio and contrast-to-noise ratio, and basically it can be determined that 3D TOF MRA and 3D CE MRA are displayed larger than in the actual measurement.