• Title/Summary/Keyword: Magnetic relaxation

Search Result 276, Processing Time 0.018 seconds

A Study on Locational Control of Motion Ghost in Magnetic Imaging System (자기공명영상장치(磁氣共鳴映像裝置)에서 움직임허상(虛像)의 위치제어(位置制御)에 관(關)한 연구(硏究))

  • Lee, Who-Min
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.19-26
    • /
    • 1993
  • Magnetic Resonance Image represents three-dimensional diagnostic imaging technique using both nuclear magnetic resonance phenomenon and computer. Compared with computed tomography (CT), MRI have advantages harmless to patient's body, three-dimensional image with high resolution and disadvantages long data acquisition time because of long T1 relaxation time, relatively low signal to noise ratio, high cost of setting, also. As physiologic motion of tissue results in motion ghost in MRI, high 2.0Tesla make improve low signal to noise ratio. This study have aim to improve image quality with controling motion ghost of tissue. Supposing a moving pixel in constant frequency, one pixel make two ghosts which are same size and different anti-phase. So, this study will show adjust parameter on locational control of motion ghost. Author made moving phantom replaced by respiratory movement of human, researched change of motion frequency, FOV by location shift, and them decided optimal FOV (field of view). The results are as follows: 1. The frequency content of the motion determines how far the image always appear in phase-encoding direction, the morphology of the ghost image is characteristic of the direction of the motion and its amplitude. 2. Double FOV of fixed signal object for locational control of motion ghost is recommended. Decreasement of spatial resolution by increasing FOV can compensate on increasing of matrix in spite of scan time increasement.

  • PDF

Low Temperature Sintering and Tunable Dielectrics Properties of Thick Films added of Li2CO3 on BST (티탄산 바륨 스트론튬(BaxSr1-xTiO3)에 Li2CO3 첨가한 후막의 저온소결과 가변 유전특성)

  • Jeon, So-Hyun;Kim, In-Sung;Jung, Sun-Jong;Song, Jae-Sung;Yoon, Jon-Do
    • Korean Journal of Materials Research
    • /
    • v.16 no.12
    • /
    • pp.747-753
    • /
    • 2006
  • (BaSr)$TiO_3$ (BST) thick films were prepared by tape casting method, using $BaTiO_3$ and $SrTiO_3$ powder slurry and their dielectric properties were investigated. With an additive, $Li_2CO_3$, the sintering temperature was lowered by $200^{\circ}C$. Sintering density was 5.7 g/$cm^3$ and the BST thick films exhibited a maximum dielectric constant, tunability at temperatures near phase transition point. Whilst their characteristics were deteriorated above the phase transition temperature, they were unchanged below the phase transition temperature, which is presumedly due to the acceleration of $90^{\circ}$ domain formation, its contribution to the relaxation of internal stress and the increase in sintering according to the replacement of Li.

In situ Stress Measurements with Submonolayer Sensitivity As a Probe of Coherent-to-incoherent Matching at an Interface in Ultrathin Magnetic Films

  • Jeong, Jong-Ryul;Kim, Young-Seok;Shin, Sung-Chul
    • Journal of Magnetics
    • /
    • v.7 no.4
    • /
    • pp.151-155
    • /
    • 2002
  • In situ stress changes at interfaces of ultrathin magnetic films were measured by means of a non-contact optical fiber bundle displacement detector. A bending of the substrate due to stress of a deposited film was detected in cantilever geometry. The highest sensitivity of 134 mV/$\mu$m for the displacement detector was realized with a help of computer simulation. The detector was applied to in situ stress measurements of Co/Pt and Ni/Pd magnetic multilayer films prepared on the glass substrates by dc magnetron sputtering. The detector turned out to have a submonolayer sensitivity that enables to observe coherent-to-incoherent transition in these mismatched multilayers and even detect the stress changes within the monoatomic coverage. This highly sensitive detector paves new way to probe the stress relaxation at an interface in ultrathin films.

Pulsed NMR Study of $CuF_{2}.2H_{2}O$ ($CuF_{2}.2H_{2}O$의 펄스 핵자기공명 연구)

  • Lee, C.E.;Yoon, E.H.;Lee, C.H.;Kim, K.;Jeon, S.J.
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.1
    • /
    • pp.13-17
    • /
    • 1993
  • We have studied $CuF_{2}.2H_{2}O$ using $^{1}H$ and $^{19}F$ pulsed nuclear magnetic resonance at 30 MHz. From the data of lineshapes, the spin-lattice relaxation times ($T_1$) and the spin echo decay times, lattice dynamics in the structure is investigated. $T_1$ data from both $^{1}H$ and $^{19}F$ NMR indicate that spin-lattice relaxation is dominated by the paramagnetic ion centers at the Cu sites. The lineshapes at room temperature appear to be strongly affected by exchange narrowing and motional narrowing.

  • PDF

($^{11}$B NMR study of vortex dynamics in LuNi$_2$B$_2$C

  • Lee, K.H.;Seo, S.W.;Kim, D.H.;Khang, K.H.;Seo, H.S.;Hwang, C.S.;Cho, B.K.;Lee, Moo-Hee
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.107-110
    • /
    • 2000
  • ($^{11}$B NMR measurements have been performed on single crystals of LuNi$_2$B$_2$C superconductor to investigate vortex lattice structures and dynamical behavior. The spectrum in the superconducting state is significantly broadened by local field inhomogeneity due to the vortex lattice and the peak point of the spectrum shifts toward low magnetic field due to the imperfect field penetration. The linewidth of the spectrum reflecting local field variation is much smaller than expected for conventional vortex lattices and shows peculiar increase at low temperature. Furthermore, the transverse relaxation rate, 1/T$_2$, probing the slow motion of vortices, exhibits a single peak as temperature decreases. These prominent results highlight significant fluctuation of vortices even for this low T$_c$, and nearly isotropic 3D superconductor.

  • PDF

Analytical Techniques for Measurement of Crosslink Densities of Rubber Vulcanizates

  • Son, Chae Eun;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • v.54 no.3
    • /
    • pp.209-219
    • /
    • 2019
  • It is important to analyze crosslink densities of rubber articles because the physical properties are dependent on the crosslink densities. In this paper, analytical techniques for the measurement of crosslink densities of rubber vulcanizates are described. The most widely used method to measure the crosslink density is a swelling method combined with the Flory-Rehner equation. Application of the interaction parameter (${\chi}$) of rubber and swelling solvent is critical because the crosslink density is absolutely dependent on the ${\chi}$ value. Methods for obtaining ${\chi}$ employ not only solubility parameters of the polymer and swelling solvent but also inverse gas chromatography (IGC). The solubilities of rubbers can be obtained using micro differential scanning calorimetry (${\mu}DSC$), intrinsic viscosity measurement, and UV-visible spectroscopy. Nuclear magnetic resonance (NMR) spectroscopy has been also used for the measurement of the crosslink density using the $T_2$ relaxation time, which is determined by spin-spin relaxation in solid-state NMR. For sulfur-cured rubber vulcanizates, crosslink densities according to the crosslink types of mono-, di-, and polysulfides are measured by treating the rubber samples with a chemical probe composed of thiol and amine compounds. Measurement methods of physical crosslinking by filler, crystallization, and ionic bonding have also been introduced.

AC Voltage and Frequency Dependence in Tunneling Magnetoresistance Device (터널링 자기저항 소자의 교류 전압 및 주파수 의존성 연구)

  • Bae, Seong-Cheol;Yoon, Seok Soo;Kim, Dong Young
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.6
    • /
    • pp.201-205
    • /
    • 2016
  • In this report, we measured the impedance spectrum in TMR device, and the relaxation behavior of the real and imaginary impedance spectrum was analyzed by using the equilibrant circuit of tunneling capacitance ($C_T$) and tunneling resistance ($R_T$). The relaxation frequency was increased with AC voltage in both the parallel and antiparallel alignment of two magnetic layers. The $R_T$ with AC voltage showed the typical bias voltage dependence. However, the $C_T$ showed large value than the expected geometrical capacitance. The huge increase of $C_T$ was affecting as a limiting factor for the high speed operation of TMR devices. Thus, the supercapacitance of $C_T$ should be considered to design the high speed TMR devices.

The Use of Polymer Gel for the Visualization of 3-D Dose Distribution in Brachytherapy Using Magnetic Resonance Imaging (방사선 근접치료에 있어서 핵자기공명영상을 이용한 3차원 방사선 선량분포도의 가시화를 위한 polymer 젤의 이용)

  • 강해진;조삼주;정은기;강승희;오영택;전미선;권수일
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.207-215
    • /
    • 1998
  • There have been many radiation measurement methods so far among which film dosimetry, TLD, and ion chamber are the most frequently used methods. But this study describes a new radiation measurement method which uses polymer gel and magnetic resonance imaging(MRI). The objective of this study is to fabricate a polymer gel sensitive to radiation and to generate a dose to MRI contrast relationship, and to apply this results to the radiation measurement for the brachytherapy. To do this, 12 cm diameter cylindrical gel phantom was made, and the phantom was irradiated using the 30 mm diameter circular collimator which was used for radiosurgery. And this irradiated phantom was scanned with MRI. To find out the relationship between the radiation dose and the transversal relaxation time, an image processing software(IDL) was used. From this study it is found out that the radiation dose showed linear relationship to the transversal relaxation time of the gel up to 17 Gy($R^2$=0.993) and they had a different relationship above 17 Gy. The dose distributions were calculated using these results for the Ir-192 sources, one for the HDR afterloading system and the other for a 2 mCi seed source. And these calculated dose distributions were compared to the ones from the treatment planning computers. From this study the dose to the irradiated gel's transversal relaxation time relationship was examined, and this result was tried for the measurement of the brachytherapy.

  • PDF

[ $^1H$ ] Nuclear Magnetic Resonance Study of Ferroelectric $(NH_4)_3H(SO_4)_2$

  • Choi, S.H.;Han, K.S.;Kwon, S.K.;Nam, S.K.;Choi, H.H.;Lee, Moo-Hee;Lim, Ae-Ran
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.11 no.2
    • /
    • pp.64-72
    • /
    • 2007
  • [ $^1H$ ] nuclear magnetic resonance (NMR) experiments have been performed at 30 - 300 K and 7 T to investigate dynamics of hydrogen bond network in the single crystal $(NH_4)_3H(SO_4)_2$. The two proton sites, ammonium proton and hydrogen-bond proton, are identified from the $^1H$ NMR MAS spectrum at 340 K. As temperature decreases, the $^1H$ NMR spectrum shifts to the higher frequency side with a larger linewidth. The spectrum at 65 K shows a distinctive change in line shape toward the ferroelectric transition at 63 K. The measured values of $T_1$ for ammonium and hydrogen-bond protons are similar in the whole range of temperature. $T_1$ of $^1H$ NMR shows a gradual decrease down to 120 K and starts to steeply increase below 100 K. Then $T_1$ shows abrupt decrease below 70 K with a sharp minimum at 63 K, where the ferroelectric transition occurs. This temperature dependence of spectrum and $T_1$ clearly prove that the large change in the dynamics of hydrogen bond network is associated with the ferroelectric phase transition at 63 K.

  • PDF

Review of SQUID Sensors for Measuring Magnetocardiography (심자도 측정을 위한 SQUID 센서 기술의 개발 현황)

  • Lee, Y.H.;Kim, J.M.;Yu, K.K.;Kim, K.;Kwon, H.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Measurement of magnetic signals generated from electric activity of myocardium provides useful information for the functional diagnosis of heart diseases. Key technical component of the magnetocardiography (MCG) technology is SQUID. To measure MCG signals with high signal-to-noise ratio, sensitive SQUID magnetic field sensors are needed. Present magnetic field sensors based on Nb SQUIDs have field sensitivity good enough to measure most of MCG signals. However, for accurate measurement of fine signal pattern or detection of local atrial fibrillation signals, we may need higher field sensitivity. In addition to field sensitivity, economic aspect of the SQUID system is also important. To simplify the SQUID readout electronics, the output voltage or flux-to-voltage transfer of SQUID should be large enough so that direct measurement of SQUID output can be done using room-temperature preamplifiers. Double relaxation oscillation SQUID (DROS), having about 10 times larger flux-to-voltage transfers than those of DC-SQUIDs, was shown to be a good choice to make the electronics compact. For effective cancellation of external noise inside a thin economic shielded room, first-order axial gradiometer with high balance, simple structure and long-baseline is needed. We developed a technology to make the axial gradiometer compact using direct bonding of superconductive wires between pickup coil and input coil. Conventional insert has mechanical support to hold the gradiometer array, and the dewar neck has equal diameter with the dewar bottom. Boiling of the liquid He can generate mechanical vibrations in the gradiometer array due to mechanical connection structure. Elimination of the mechanical support, and direct mounting of the gradiometer array into the dewar bottom can reduce the dewar neck diameter, resulting in the reduction of liquid He consumption.