Magnetic Dipole Model in an Eddy Current Flow Detection for a Nondestructive Evaluation

  • Han, S.G.;Kang, J.H.
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.266-270
    • /
    • 1999
  • A SQUID magnetometer or a SQUID gradiometer can be used to measure the field or gradient distribution, respectively. We describe the magnetic dipole model of the eddy currents in a nondestructive evaluation. Such a theoretical calculation of the magnetic dipole fields produced by a deep flaw in metallic materials can be used in aerospace and transportation industries.

  • PDF

Magnetic dipole model in an eddy current flow detection for a Nondestructive evaluation

  • Han, S.G.;Kim, J.Y.;Kang, J.H.
    • Progress in Superconductivity
    • /
    • v.1 no.1
    • /
    • pp.26-30
    • /
    • 1999
  • A SQUID magnetometer or a SQUID gradiometer can be used to measure the field or gradient distribution respectively. We describe the magnetic dipole model of the eddy current for the nondestructive evaluation. Such a theoretical calculation of the magnetic dipole field produced by a deep flaw in matalic materials can be used for aerospace and transportation fields.

  • PDF

Microscopic Interdiffusion in Multilayer Structure

  • Kim, Jai-Young
    • Journal of Magnetics
    • /
    • v.2 no.2
    • /
    • pp.58-66
    • /
    • 1997
  • Recently, artificially modulated magnetic multilayer materials, for examples giant magnetoresistant magnetic head materials and magneto-optic recording materials in the wavelength of a blue laser beam, attract great attention in the electronics industry due to their unique properties derived from the modulated multilayer structure. Since the multilayer structure as well as amorphous structure, is non-equilibrium state in terms of free energy, an assessment of the thermal staibility in the multilayer structure is crucially importnat both for basic research and applications. In this review paper, effective microscopic interdiffusion process in the two dimensional multilayer structure will be described in terms of steep concentration gradient effect, strain effect and magnetic transition effect.

  • PDF

Treatment of Rolled Steel Coolant Wastewater by Superconducting High Gradient Magnetic Separation

  • Kim, Tea-Hyung;Ha, Dong-Woo;Oh, Sang-Soo;Kim, Ho-Sup;Ko, Rock-Kil;Lee, Nam-Jin;Kwon, Jun-Mo;Kim, Young-Hun;Kung, Chae-Hun;Ha, Tae-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.354-354
    • /
    • 2009
  • We have developed the prototypes of superconducting magnetic separation system with high temperature superconductor wire. This separation filter system consist of magnetized matrix SUS430 wire and acrylic frame. This study introduced rolled steel process coolant wastewater applied superconductor HGMS(High Gradient Magnetic Separation). HGMS treatment have acted high efficient method for various wastewater. We have surveyed superconducting magnetic separation technology and reviewed the status of related industries using applied superconductivity. In our basic preliminary experiment using HGMS, it was made clear that the fine para-magnetic particles in the wastewater obtained from rolling process of steel can be separated with high efficiency. We investigated the ability of magnetic flock formation, which used inorganic materials and polymer coagulants. We had a purpose to remove SS of coolant at steel factory. Maximum coagulation remove rate of SS 98%. Removing ratio of $Fe_3O_4$ fine particles in wastewater showed over than 99% in the wastewater containing magnetic fines after four times of repetition of separation.

  • PDF

Minimum-Power Design of Actively-Shielded Transverse Gradient Coils for MRI (MRI용 차폐된 X,Y-경사자계코일의 최소전력설계)

  • Lee, D.R.;Kim, S.K.;Yang, Y.J.;Lee, H.K.;Ahn, C.B.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.307-309
    • /
    • 1996
  • A new design scheme of actively-shielded x,y-gradient coils for Magnetic Resonance Imaging(MRI) is proposed. An actively-shielded x-gradient coil has been designed as an example and the results are presented. In MRI, gradient coils are needed for spatial selection and position coding to obtain the position information of the NMR signal. They are usually switched on and off during imaging and the eddy current induced by the current switching usually degrades the final image quality To reduce or remove this kind of problems, the active shielding has been proposed few years ago. In this paper, a new design scheme for actively-shielded x,y-gradient coils, namely, a minimum-power design scheme using current-loop elements, has been proposed. Its utility in designing MRI gradient coils has been shown by using simulation. The design scheme seems to be useful for actively-shielded transverse gradient coils, even of non-cylindrical or of arbitrary-selected shapes.

  • PDF

Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI (MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석)

  • Lee H. R.;Han J. Y.;Cho M. H.;Im C. H.;Jung H. K.;Lee S. Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.108-115
    • /
    • 2003
  • Purpose : To evaluate the effect of the gradient switching noise on the ECD source localization with the EEG data recorded during the MRI scan. Materials and Methods : We have fabricated a spherical EEG phantom that emulates a human head on which multiple electrodes are attached. Inside the phantom, electric current dipole(ECD) sources are located to evaluate the source localization error. The EEG phantom was placed in the center of the whole-body 3.0 Tesla MRI magnet, and a sinusoidal current was fed to the ECD sources. With an MRI-compatible EEG measurement system, we recorded the multi channel electric potential signals during gradient echo single-shot EPI scans. To evaluate the effect of the gradient switching noise on the ECD source localization, we controlled the gradient noise level by changing the FOV of the EPI scan. With the measured potential signals, we have performed the ECD source localization. Results : The source localization error depends on the gradient switching noise level and the ECD source position. The gradient switching noise has much bigger negative effects on the source localization than the Gaussian noise. We have found that the ECD source localization works reasonably when the gradient switching noise power is smaller than $10\%$ of the EEG signal power. Conclusion : We think that the results of the present study can be used as a guideline to determine the degree of gradient switching noise suppression in EEG when the EEG data are to be used to enhance the performance of fMRI.

  • PDF

Study of Magnetic Filtration for Subway MVAC Dust (지하철 공조실 미세먼지에 대한 자성포집연구)

  • Park, Hae Woo;Chung, Sang Gui;Jo, Young Min
    • Particle and aerosol research
    • /
    • v.11 no.2
    • /
    • pp.37-46
    • /
    • 2015
  • Dust particles, which inflow to the subway mechanical ventilation and air conditioning(MVAC) chamber, contain a fair amount of iron compounds, approximately 25.2w/w%. This work attempted to capture those iron containing dust using magnetic filters. Average magnetization value of the test MVAC dust was 0.012 emu on 5,000 Oe, which could correspond sufficiently with the magnetic interaction. External permanent magnets provided with magnetization of iron mesh screen showing high gradient magnetic field(HGM). It resulted in the capture efficiency with 84.0 ~ 99.7% and 81.2 ~ 99.8% for $PM_{10}$ and $PM_{2.5}$ respectively. Magnetic capture was found to be closely associated with the magnetic intensity, mesh opening size and flow velocity.

A Study of the Hull Form of Oil Recovery Vessel by Using Magnetic Fluid (자성유체를 이용한 유회수선박의 선형연구)

  • 이귀주;박영식;김경화;노준혁;장희문
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.1-5
    • /
    • 2001
  • A study on the new active type oil-water separation system including the oil-water separation system of magnetic film was carried out. Separation system is composed of several active types of circulating oil separation steps and one magnetic film separation step at final stage. At the magnetic separation step, ferrofluid easily forms a weak magnetic mixture with oil, which is from the water by magnetic field gradient. The vessel has been designed to run at the maximum speed of 25 knots. And two typical forms of SWATH and Catamaran have been studied as a new type of oil recovery vessel.

  • PDF

Strain gradient theory for vibration analysis of embedded CNT-reinforced micro Mindlin cylindrical shells considering agglomeration effects

  • Tohidi, H.;Hosseini-Hashemi, S.H.;Maghsoudpour, A.;Etemadi, S.
    • Structural Engineering and Mechanics
    • /
    • v.62 no.5
    • /
    • pp.551-565
    • /
    • 2017
  • Based on the strain gradient theory (SGT), vibration analysis of an embedded micro cylindrical shell reinforced with agglomerated carbon nanotubes (CNTs) is investigated. The elastic medium is simulated by the orthotropic Pasternak foundation. The structure is subjected to magnetic field in the axial direction. For obtaining the equivalent material properties of structure and considering agglomeration effects, the Mori-Tanaka model is applied. The motion equations are derived on the basis of Mindlin cylindrical shell theory, energy method and Hamilton's principal. Differential quadrature method (DQM) is proposed to evaluate the frequency of system for different boundary conditions. The effects of different parameters such as CNTs volume percent, agglomeration of CNTs, elastic medium, magnetic field, boundary conditions, length to radius ratio and small scale parameter are shown on the frequency of the structure. The results indicate that the effect of CNTs agglomeration plays an important role in the frequency of system so that considering agglomeration leads to lower frequency. Furthermore, the frequency of structure increases with enhancing the small scale parameter.

A Study on the Characteristics of Electronic Magnetic Interference(EMI) in Acoustic Emission Testing for Corrosion Detection of Ground Tank (지상탱크의 부식감지를 위한 음향방출시험에서 발생한 전자기간섭신호의 특성 연구)

  • Kim, Sung-Dai;Jung, Woo-Gwang
    • Korean Journal of Materials Research
    • /
    • v.17 no.5
    • /
    • pp.239-243
    • /
    • 2007
  • The evaluation and comparison have been made for the EMI noise which was included in the signal from the sensors in the acoustic emission testing for the bottom plate of ground tank at full. The EMI signal has been classified into two types. One is the signal with very short AE count, and this signal possibly can be filtered by front end filter setting of the channel count with low level of 4 and high level of $10^8$. The other EMI signal occurred from CH 1, CH 3 and CH 10, and had high and constant duration with high energy and count (maximun duration > $10^5\;{\mu}s$), and has characteristic gradient of accumulation amplitude distribution. This signal should be removed in the AE signal evaluation by filtering, because this may affect to the total gradient.