• Title/Summary/Keyword: Magnetic field gradient

Search Result 217, Processing Time 0.025 seconds

Crystallographic and Mossbauer studies of $Ni_{0.65}Zn_{0.35}Cu_{0.1}Fe_{1.9}O_4$ ($Ni_{0.65}Zn_{0.35}Cu_{0.1}Fe_{1.9}O_4$의 결정학적 및 Mossbauer 효과 연구)

  • 김우철;이승화;홍성렬;옥항남;김철성
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.3
    • /
    • pp.118-124
    • /
    • 1998
  • $Ni_{0.65}Zn_{0.35}Cu_{0.1}Fe{1.9}O_4$ has been studied with Mossbauer spectroscopy and X-ray diffraction. The crystal structure is found to be a cubic spinel with the lattice constant $a_0=8.390{\AA}$. Mossbauer spectra of $Ni_{0.65}Zn_{0.35}Cu_{0.1}Fe{1.9}O_4$ has been taken at various temperatures ranging from 12 K to 705 K. The isomer shift indicates that iron ions are ferric at tetrahedral [A] and octahedral sites [B], respectively. The Neel temperature is determined to be $T_N=705\;K$. As the temperature increases toward $T_N$ a systematic line broadening effect in the Mossbauer spectrum is observed and interpreted to originate from different temperature dependencies of the magnetic hyperfine fields at various iron sites. The quadrupole splitting just on $T_N$ is 0.41 mm/s whereas the quadrupole shift below $T_N$ vanishes. This implies that the orientation of the magnetic hyperfine field with respect to be principal axes of the electric field gradient is random.

  • PDF

Evaluation of Hydration Effect on Human Skin by $^1H$ MRS at 14.1T

  • Choi Chi-Bong;Hong Sung-Tak;Choe Bo-Young;Woo Dong-Chul;Yoon Seong-Ik;Cho Ji-Hyun;Lee Chul-Hyun;Cheong Chae-Joon;Park Sang-Yong;Oh Chil-Hwan
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.10 no.1
    • /
    • pp.105-114
    • /
    • 2006
  • Purpose: We achieved high resolution MR imaging and spectra of human skin in vitro with using a 14.1 T MRI/MRS system, and evaluated the hydration effect of various cosmetic products by measuring the skin's. moisture concentration. Materials and Methods: We used the Bruker 14.1 T MRI/MRS system with a vertical standard bore that was equipped with a DMX spectrometer gradient system (200 G/cm at a maximum 40 A), RF resonators (2, 5 and 10 mm) and Para Vision software. Spin echo and fast spin echo pulse sequences were employed for obtaining the high resolution MR images. The 3D-localized point resolved spectroscopy (PRESS) method was used to acquire the MR spectra. Results: The high resolution MR images and spectra of human skin in vitro were successfully obtained on a 14.1 T system. The water concentration of human skin after applying a moisturizer was higher than that before applying a moisturizer. Conclusions: The present study demonstrated that the high-resolution MR images and spectra of human skin from a high field NMR instrument could be applicable to evaluating the hydration state of the stratum corneum.

  • PDF

Rapid gravity and gravity gradiometry terrain corrections via an adaptive quadtree mesh discretization (최적 4 진트리 격자화를 이용한 중력 및 중력 변화율 탐사에서의 고속 지형보정)

  • Davis, Kristofer;Kass, M.Andy;Li, Yaoguo
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.1
    • /
    • pp.88-97
    • /
    • 2011
  • We present a method for modelling the terrain response of gravity gradiometry surveys utilising an adaptive quadtree mesh discretization. The data- and terrain-dependent method is tailored to provide rapid and accurate terrain corrections for draped and barometric airborne surveys. The surface used in the modelling of the terrain effect for each datum is discretized automatically to the largest cell size that will yield the desired accuracy, resulting in much faster modelling than full-resolution calculations. The largest cell sizes within the model occur in areas of minimal terrain variation and at large distances away from the datum location. We show synthetic and field examples for proof of concept. In the presented field example, the adaptive quadtree method reduces the computational cost by performing 351 times fewer calculations than the full model would require while retaining an accuracy of one E$\"{o}$tv$\"{o}$s for the gradient data. The method is also used for the terrain correction of the gravity field and performed 310 times faster compared with a calculation of the full digital elevation model.

SNU 1.5MV Van de Graaff Accelerator (IV) -Fabrication and Aberration Analysis of Magnetic Quadrupole Lens- (SNU 1.5MV 반데그라프 가속기 (IV) -자기 4극 렌즈의 제작과 수차의 분석-)

  • Bak, H.I.;Choi, B.H.;Choi, H.D.
    • Nuclear Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 1986
  • A magnetic quadrupole doublet was fabricated for use at the pre-target position of SNU 1.5MV Van de Graaff accelerator and then its optical characteristics were measured and analysed. The physical dimensions are: pole length 180mm, aperture radius 25mm, pole tip radius 28.75mm. Material for poles and return yokes is carbon steel KS-SM40C. Coils have 480 turns per one pole and air-cooling is adopted. Applying the d.c. current 2.99$\pm$0.03A to the lens, and using the Hall probe, magnetic field elements $B_{\theta}$ , $B_{\gamma}$, were measured at the selected Points along each coordinate direction r,$\theta$, z. From the area integration and orthogonal polynomial fitting for the measured data, the magnetic Field gradient G=566.3$\pm$2.1 gauss/cm at lens center, the effective length L=208.3$\pm$1.44mm along the lens axis have been obtained. The harmonic contents were determined up to 20-pole from the generalized least squares fitting. The results indicate that sextupole/quadrupole is below 1.4$\pm$0.9% and all the other multipoles are below 0.5% in the region within 18mm radius at the center of lens.

  • PDF

Evaluation of usefulness of multi directional angles oblique scan method in optic nerve MRI (시각신경 MR 검사 시 다중 각도 스캔 기법의 유용성 평가)

  • Cho, Moo-Seong;Cho, Jae-Hwan;Bae, Jae-Yeong;Kim, Jeong-Soo;Kim, Kyeong-Keun
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.161-169
    • /
    • 2011
  • This research experimented on the change of the multiple colleague scan angle facing one scan object facet to many directions of the form of 3D about the visual angle nervous system forming the cubic distribution with the gradient magnetic field of the mri system and considered the existing basic angle oblique direction test coverage and comparison. MR system can freely select various pulse sequence and image slice. To oblique imaging for optic nerve viewing, we have studied the variation of scan angle between typical oblique scan method (sagittal-coronal plane) and multi directional angles oblique scan method (sagittal-coronal-axial plane) using gradient of MR system. In this study, the subjects of the experiment were normal adults in our country. As a result, we confirmed that multi directional angles oblique scan method can display anatomical information of more wider area than typical oblique scan method. In addition, to clearly display optic nerve, we also confirmed that image slice thickness and pulse sequence have effect on it.

Observation of Molecular Relaxation Behavior of Glucose Powders with Different Structures and Particle Sizes Using Low Field Nuclear Magnetic Resonance (NMR) (NMR을 이용한 구조 및 입도 차이에 따른 분말 포도당의 molecular relaxation behavior의 관찰)

  • Chung, Myung-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.1140-1144
    • /
    • 2002
  • Molecular relaxation behaviors of crystalline glucose anhydrous, crystalline glucose monohydrate, and amorphous glucose with different particle sizes were observed by measuring spin-spin relaxation time constant $(T_2)$ at the temperature range of $-20\;to\;110^{\circ}C$ using temperature-controlled low field nuclear magnetic resonance spectroscopy. No change in $T_2$ values of crystalline glucose anhydrous was observed throughout the temperature range, whereas $T_2$ values of crystalline glucose monohydrate and amorphous glucose increased from around $45\;and\;65^{\circ}C$, respectively. These results indicate that molecular mobility of crystalline glucose anhydrous does not change even at temperature higher than $100^{\circ}C$ and that the stability of powdered glucose could be improved by increasing the particle size of materials.

Effect of crystal and crucible rotations on the mass transfer in magnetohydrodynamic Czochralski crystal growth of silicon (자기장이 가하여진 초크랄스키 실리콘 단결정 성장에서 질량전달에 미치는 성장결정과 도가니의 회전효과)

  • 김창녕
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.4
    • /
    • pp.536-547
    • /
    • 1997
  • For various angular velocities of crucible and crystal, the characteristics of melt flows, temperatures and concentrations of oxygen are numerically studied in the Czochralski furnace with a uniform axial magnetic field. Buoyancy effect due to the heating of crucible wall and thermocapillary effect due to the temperature gradient at the free surface, can be differentiably suppressed by the centrifugal forces due to the rotations of the crucible and crystal. The most important factor which yields the centrifugal forces is the rotation velocity of the crucible, that influences the fields of velocities, temperatures and concentrations. In the case that the crucible rotation velocity is not high, the rotations of the crystal gives rise to the centrifugal forces effectively.

  • PDF

Development of the Measuring Device of Muzzle Velocity using Magnetic Field Gradient Sensor (자계 차분형 센서를 이용한 초소형/고정밀 탄속 측정장치 개발)

  • 채제욱;김종천;최의중;이영신
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.22-28
    • /
    • 2003
  • In the conventional weapon system, such as gun and small arms, it Is a general trend that for maximization of its performance and enhancement of its effectiveness, the firing control system(FCS) is developed and applied with the guns and small arms in the world. The FCS of the small arms for infantry man is composed of a few of sensors for acquisition of input data of FCS, such as range measurement, position sensing of weapon, temperature, etc., computer, displayer and power pack, and also the air burst munition is developed in parallel for the maximization of FCS's effectiveness. Since the flight time setting fuze for the air burst munition is adapted for next me, the measuring device of the muzzle velocity is needed to overcome the variation of muzzle velocity due to producing procedures and the differences of the using temperatures and so maintain the burst position accuracy This paper contained the technical information on the development of the measuring device of muzzle velocity, which designed in compact & light weight configuration with reliability and accuracy.

Dynamics of a Bose-Einstein Condensate on Changing Speeds of an Atomchip Trap Potential

  • Kim, Seung Jin;Noh, Jae June;Kim, Min Seok;Lee, Jin Seung;Yu, Hoon;Kim, Jung Bog
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.633-638
    • /
    • 2014
  • We report experimental behaviors of condensed $^{87}Rb$ atoms responding to changes in the trap potential of the atomchip. The two-types of adiabatic and non-adiabatic overall changes were implemented by changing the ramp-down speed of the chip-wire current, which can dominantly modify the one-axis magnetic field gradient. Under the adiabatic process, a pure condensate stayed in the initial spin state and collectively oscillated with both monopole and dipole modes, while an atomic cloud above the critical temperature exhibited sound waves in a dense ultracold gas. On the other hand, Bose-Einstein condensate atoms with non-adiabatic perturbation were split into spatially different positions by spin states through spin-flip. We investigated the split ratio among spin states depending on final evaporation frequency. Potential changes, of course, cause collective oscillations regardless of the changing process.

Design of External Coil System for Reducing Artifact of MR Image due to Implantable Hearing Aid (이식형 보청기에 의한 자기공명 영상의 인공음영 축소를 위한 외부 코일 시스템 설계)

  • Ahn, Hyoung Jun;Lim, Hyung-Gyu;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.375-385
    • /
    • 2016
  • Recently, several implantable hearing aids such as cochlear implant, middle ear implant, etc., which have a module receiving power and signal from outside the body, are frequently used to treat the hearing impaired patients. Most of implantable hearing aids are adopted permanent magnet pairs to couple between internal and external devices for the enhancement of power transmission. Generally, the internal device which containing the magnet in the center of receiving coil is implanted under the skin of human temporal bone. In case of MRI scanning of a patient with the implantable hearing aid, however, homogeneous magnetic fields of the MRI might be interfered by the implanted magnet. For the above reasons, the MR image is degraded by large area of artifact, so that diagnostics are almost impossible in deteriorated region. In this paper, we proposed an external coil system that can reduce the artifact of MR image due to the internal coupling magnet. By finite element analysis estimating area of MR artifact according to varying current and shape of the external coil, optimal coil parameters were extracted. Finally, the effectiveness of the proposed external coil system was verified by confirming the artifact at real MRI scan.