• Title/Summary/Keyword: Magnetic field Strength

검색결과 395건 처리시간 0.257초

Domination of glassy and fluctuation behavior over thermal activation in vortex state in $MgB_2$ thin film ($MgB_2$ 박막에서의 열적 활성화에 비해 두드러진 볼텍스 유리화 및 열적 요동현상의 연구)

  • Kim, Heon-Jung;W. N. Kang;Kim, Hyeong-Jin;Park, Eun-Mi;Kim, Kijoon H. P.
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.23-27
    • /
    • 2001
  • We have investigated the mixed-state magnetoresistance of high quality c-axis-oriented MgB2 thin film for magnetic field from 0.5 T to 5.0 T, applied normal to ab-plane. The temperature dependence of magnetoresistance was well described by vortex glass and fluctuation theories for different temperature regimes. We observed glassy exponent of v(z-1)~3 and upper critical field of $H_{c2}$(0)~35 T, which is consistent with previous data obtained from direct $H_{c2}$(0) measurements. Interestingly, the thermally activated flux flow region was observed to be very narrow, suggesting that the pinning strength of this compound is very strong. This finding is closely related to the recent reports that the bulk pinning is dominant in $MgB_2$and the critical current density of $MgB_2$ thin film is very high, comparable to that of cuprate superconductor. The present results further suggest that $MgB_2$is beneficial to technical applications.ons.

  • PDF

Magnetic Properties of Fe-6.0 wt%Si Alloy Dust Cores Prepared with Phosphate-coated Powders (인산염 피막처리 분말을 사용한 Fe-6.0 wt%Si 합금 압분자심의 자기적 특성)

  • Jang, D.H.;Noh, T.H.;Kim, K.Y.;Choi, G.B.
    • Journal of the Korean Magnetics Society
    • /
    • 제15권5호
    • /
    • pp.270-275
    • /
    • 2005
  • Dust cores (compressed powder cores) of $Fe-6.0wt\%Si$ alloy with a size of $35\~180\;{\mu}m$ in diameter have been prepared by phosphate coatings and annealings at $600\~900^{\circ}C$ for 1 h in nitrogen atmosphere. Further the magnetic and mechanical properties of the powder cores were investigated. As a general trends, the compressive strength and core loss decreased with the increase in annealing temperature. When annealed at $800^{\circ}C$, the compressive strength was 15 kgf, the permeability and quality factor were 74 and 26, respectively. Moreover the core loss at 50 kHz and 0.1 T induction was $750\;mW/cm^3$, and the percent permeability under the static field of 50 Oe was estimated to be about 78. In addition, the cut-off frequency in the cure representing the frequency dependence of effective permeability was measured to be around 200 kHz. These properties of the $Fe-6.0wt\%Si$ alloy dust cores could be considered to be due to the good insulation effect of iron-phosphate coats, the decrease in magnetocrystalline anisotropy and saturation magnetostriction and the increase in electric resistivity.

Palaeomagnetism of the Okchon Belt, Korea : Anisotropy of Magnetic Susceptibility (AMS) and Deformation of the Hwanggangri Formation in Chumgju-Suanbo Area (옥천대에 대한 고자기 연구:충주-수안보 일원 황강리층의 변형과 대자율 비등방성(AMS))

  • Son, Moon;Kim, In-Soo;Kang, Hee-Cheol
    • Economic and Environmental Geology
    • /
    • 제34권1호
    • /
    • pp.133-146
    • /
    • 2001
  • We report the results of structural field observation and measurement of anisotropy of magnetic susceptibility (AMS) of the diamictitic Hwanggangri Formation distributed in Chungju-Suanbo area of the Okchon Belt, Korea. The outcrops of the Hwanggangri Formation show two types of cleavage in general: slaty cleavage (SI) and crenulation cleavage (5z). 5] cleavage is, however, well observable only in the notheastem (NE) part of study area, while overwhelmed by 52 cleavage in the southwestern (5W) part, indicating stronger later deformation in 5W part of the study area. This partitioning of the study area is corroborated by both IRM and AMS parameters: NE part of the study area is characterized by higher IRM intensity, higher bulk magnetic susceptibility, higher AM5 degree, and by oblate shape of magnetic susceptibility ellipsoid. Their values become drastically lowered toward southwest, and reach to a stable minimum in the whole 5W part of the study area. In addition, degree of both metamorphism and deformation tends to increase gradually from northeast toward southwest and also from northwest toward southeast in the study area. Based on the distribution pattern of the principal axes ( $k_1, k_2, k_3$ axes) of magnetic anisotropy ellipsoids revealed in the NE part of the study area, three episodes of deformation ( $D_1, D_2, D_3$ ) are recognized: D_1$ deformation produced $S_2$ cleavage with NE-5W trend, which is caused by a strong NW-SE tlattening of a coaxial pure shear. $D_2$ deformation produced 5z cleavage characterized by a non-coaxial deformation. It was caused by a ductile or semi-ductile thrusting toward NW and concurrent sinistral shearing along $S_2$ cleavage plane. Lastly, $D_3$ deformation produced tlexural folding of all previous structures with a nearly horizontal NE fold axis. Distribution pattern of the principal axes of magnetic anisotropy ellipsoid from the SW part of the study area, on the other hand, does not show any coherency among sites or samples. We interpret that this dispersed pattern of $k_1, k_2, k_3$ axes together with lower anisotropy strength indicates that magnetic fabrics in the SW part have been disturbed either by a superposition of strong deformation/metamorphism or by a kind of reciprocal strain due to an overlapping of $D_1$ and $D_2$ or by both processes.

  • PDF

Magnetron Sputter Coating of Inner Surface of 1-inch Diameter Tube

  • Han, Seung-Hee;An, Se-Hoon;Song, In-Seol;Lee, Keun-Hyuk;Jang, Seong-Woo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.135-135
    • /
    • 2015
  • Tubes are of extreme importance in industries as for fluid channels or wave guides. Furthermore, some weapon systems such as cannons use the tubes as gun barrels. To increase the service life of such tubes, a protective coating must be applied to the tubes' inner surface. However, the coating methods applicable to the inner surface of the tubes are very limited due to the geometrical restriction. A small-diameter cylindrical magnetron sputtering gun can be used to deposit coating layers on the inner surface of the large-bore tubes. However, for small-bore tubes with the inner diameter of one inch (~25 mm), the magnetron sputtering method can hardly be accommodated due to the space limitation for permanent magnet assembly. In this study, a new approach to coat the inner surface of small-bore tubes with the inside diameter of one inch was developed. Instead of using permanent magnets for magnetron operation, an external electro-magnet assembly was adopted around the tube to confine the plasma and to sustain the discharge. The electro-magnet was operated in pulse mode to provide the strong axial magnetic field for the magnetron operation, which was synchronized with the negative high-voltage pulse applied to the water-cooled coaxial sputtering target installed inside the tube. By moving the electro-magnet assembly along the tube's axial direction, the inner surface of the tube could be uniformly coated. The inner-surface coating system in this study used the tube itself as the vacuum chamber. The SS-304 tube's inner diameter was 22 mm and the length was ~1 m. A water-cooled Cu tube (sputtering target) of the outer diameter of 12 mm was installed inside of the SS tube (substrate) at the axial position. The 50 mm-long electro-magnet assembly was fed by a current pulse of 250 A at the frequency and pulse width of 100 Hz and 100 usec, respectively. The calculated axial magnetic field strength at the center was ~0.6 Tesla. The central Cu tube was synchronously driven by a HiPIMS power supply at the same frequency of 100 Hz as the electro-magnet and the applied pulse voltage was -1200 V with a pulse width of 500 usec. At 150 mTorr of Ar pressure, the Cu deposition rate of ~10 nm/min could be obtained. In this talk, a new method to sputter coat the inner surface of small-bore tubes would be presented and discussed, which might have broad industrial and military application areas.

  • PDF

The Effect of Residual H2Pressure on Gallium-doped ZnO Films Deposited by Magnetron Sputtering (마그네트론 스퍼터링에 의해 제작한 Gallium-doped ZnO 박막에 있어서 잔류 H2O 분압의 영향)

  • Song, Pung-Keun;Kwon, Young-Jun;Cha, Jae-Min;Lee, Byung-Chul;Ryu, Bong-Ki;Kim, Kwang-Ho
    • Journal of the Korean Ceramic Society
    • /
    • 제39권10호
    • /
    • pp.928-934
    • /
    • 2002
  • Gallium doped Zinc Oxide(GZO) films were deposited by dc magnetron sputtering using a GZO ceramic target at various conditions such as substrate temperature (RT, 400), residual water pressure ($P_{H_2O}$; 1.61${\times}10^{-4}∼2.2{\times}10^{-3}$ Pa), introduction of $H_2$ gas (8.5%) and different magnetic field strengths(250, 1000G). GZO films deposited without substrate heating showed clear degradation in film crystallinity and electrical properties with increasing $P_{H_2O}$. The resistivity increased from 3.0${\times}10^{-3}$ to 3.1${\times}10^{-2}{\Omega}㎝$ and the grain size of the films decreased from 24 to 3 nm when PH2O was increased from 1.61${\times}10^{-4}$ to 2.2${\times}10^{-3}$ Pa. However, degradation in electrical properties with increasing $P_{H_2O}$ was not observed for the films deposited with introduction of 8.5% $H_2$. When magnetic field strength of the cathode increased from 250G to 1000G, crystallinity and electrical properties of GZO films improved remarkably about all the $P_{H_2O}$. This result could be attributed to the decrease in film damage caused by the decrease in plasma impedance.

Metal Artifact Caused by Magnetic Field Strength and Sequence on T1WI-MRI (자기공명영상에서 자장세기와 시퀀스에 따른 아티팩트 변화)

  • Ko, Seong-Jin
    • The Journal of the Korea Contents Association
    • /
    • 제10권9호
    • /
    • pp.302-308
    • /
    • 2010
  • In MRI, the Ferromagnetic artifact is generated by the metalization within in which the before inspection removal is impossible and the distortion of an image is brought. The distortion measure according to the steel for each sequence of T1 image and magnetic field intensity are analyzed and minimized method is looked into. We used SIEMENS 1.5T and 3.0T MRI for experiment equipment. First, it places within the Phantom making a metalization(Ti+Al, Stainless, Nitinol) on 1.5T, 3.0T MRI and the T1 weighted image for each Sequence is acquired. The distortion of an image and about adjacent portion change of the metal material were compared through the obtained image, we analyzed. In all metalizations, a distortion was generated and a distortion was few in particularly, and Titanium-Aluminium alloy. And the extent of a distortion was worse image in the Turbo spin Echo. The use of the Titanium-Aluminium alloy the inserted in an internal material of the metalization is recommend. and, equipment of 1.5T the patient inserting a metal in an internal is used in an inspection than equipment of 3.0T. Also, the sequence is suitable when it obtains the optimum T1 weighted image of an impersonate to use the Turbo spin Echo.

Digital Processing and Acoustic Backscattering Characteristics on the Seafloor Image by Side Scan Sonar (Side Scan Sonar 탐사자료의 영상처리와 해저면 Backscattering 음향특성)

  • 김성렬;유홍룡
    • 한국해양학회지
    • /
    • 제22권3호
    • /
    • pp.143-152
    • /
    • 1987
  • The digital data were obtained using Kennedy 9000 magnetic tape deck which was connected to the SMS960 side scan sonar during the field operations. The data of three consecutive survey tracks near Seongsan-po, Cheju were used for the development of this study. The softwares were mainly written in Fortran-77 using VAX 11/780 MINI-COMPUTER (CPU Memory; 4MB). The established mapping system consists of the pretreatment and the digital processing of seafloor image data. The pretreatment was necessary because the raw digital data format of the field magnetic tapes was not compatible to the VAX system. Therefore the raw data were read by the personal computer using the Assembler language and the data format was converted to IBM compatible, and next data were communicated to the VAX system. The digital processing includes geometrical correction for slant range, statistical analysis and cartography of the seafloor image. The sound speed in the water column was assumed 1,500 m/sec for the slant range correction and the moving average method was used for the signal trace smoothing. Histograms and cumulative curves were established for the statistical analysis, that was purposed to classify the backscattering strength from the sea-bottom. The seafloor image was displayed on the color screen of the TEKTRONIX 4113B terminal. According to the brief interpretation of the result image map, rocky and sedimentary bottoms were very well discriminated. Also it was shown that the backscattered acoustic pressurecorrelateswith the grain size and sorting of surface sediments.

  • PDF

Synthesis of Pressure-sensitive Acrylic Adhesives with Photoreactive Groups and Their Application to Semiconductor Dicing Tapes (광 반응성기를 갖는 아크릴 점착제의 합성과 반도체 다이싱 테이프로의 적용 연구)

  • Hee-Woong Park;Nam-Gyu Jang;Kiok Kwon;Seunghan Shin
    • Applied Chemistry for Engineering
    • /
    • 제34권5호
    • /
    • pp.522-528
    • /
    • 2023
  • In this work, adhesive tapes were prepared for the dicing process in semiconductor manufacturing. Compounds with different numbers of photoreactive groups (f = 1 to 3) were synthesized and incorporated into acrylic copolymers to formulate UV-curable acrylic adhesives. Structural confirmation of the synthesized photoreactive compounds (f = 2 or 3) was performed using nuclear magnetic resonance (NMR) spectroscopy. The introduction of the photoreactive compounds into the acrylic adhesive was accomplished by urethane reactions, and the successful synthesis of the UV-curable acrylic adhesive was verified by Fourier transform infrared (FT-IR) measurements. To evaluate the performance of the adhesive, the peel strength was evaluated before and after UV irradiation using a silicon wafer as a substrate. The adhesive exhibited high peel strength (~2000 gf/25 mm) before UV exposure, which was significantly reduced (~5 gf/25 mm) after UV exposure. Interestingly, the adhesive containing multifunctional photoreactive compounds showed the most significant reduction in peel strength. In addition, surface residue measurements by field emission scanning electron microscopy (FE-SEM) showed minimal surface residue (~0.2%) after UV exposure. Overall, these results contribute to the understanding of the behavior of UV-curable acrylic adhesives and pave the way for potential applications in semiconductor manufacturing processes.

Diagnostic Yield of Diffusion-Weighted Brain Magnetic Resonance Imaging in Patients with Transient Global Amnesia: A Systematic Review and Meta-Analysis

  • Su Jin Lim;Minjae Kim;Chong Hyun Suh;Sang Yeong Kim;Woo Hyun Shim;Sang Joon Kim
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1680-1689
    • /
    • 2021
  • Objective: To investigate the diagnostic yield of diffusion-weighted imaging (DWI) in patients with transient global amnesia (TGA) and identify significant parameters affecting diagnostic yield. Materials and Methods: A systematic literature search of the MEDLINE and EMBASE databases was conducted to identify studies that assessed the diagnostic yield of DWI in patients with TGA. The pooled diagnostic yield of DWI in patients with TGA was calculated using the DerSimonian-Laird random-effects model. Subgroup analyses were also performed of slice thickness, magnetic field strength, and interval between symptom onset and DWI. Results: Twenty-two original articles (1732 patients) were included. The pooled incidence of right, left, and bilateral hippocampal lesions was 37% (95% confidence interval [CI], 30-44%), 42% (95% CI, 39-46%), and 25% (95% CI, 20-30%) of all lesions, respectively. The pooled diagnostic yield of DWI in patients with TGA was 39% (95% CI, 27-52%). The Higgins I2 statistic showed significant heterogeneity (I2 = 95%). DWI with a slice thickness ≤ 3 mm showed a higher diagnostic yield than DWI with a slice thickness > 3 mm (pooled diagnostic yield: 63% [95% CI, 53-72%] vs. 26% [95% CI, 16-40%], p < 0.01). DWI performed at an interval between 24 and 96 hours after symptom onset showed a higher diagnostic yield (68% [95% CI, 57-78%], p < 0.01) than DWI performed within 24 hours (16% [95% CI, 7-34%]) or later than 96 hours (15% [95% CI, 8-26%]). There was no difference in the diagnostic yield between DWI performed using 3T vs. 1.5T (pooled diagnostic yield, 31% [95% CI, 25-38%] vs. 24% [95% CI, 14-37%], p = 0.31). Conclusion: The pooled diagnostic yield of DWI in TGA patients was 39%. DWI obtained with a slice thickness ≤ 3 mm or an interval between symptom onset and DWI of > 24 to 96 hours could increase the diagnostic yield.

Treatment Methods for Functional Recovery after Total Knee Arthroplasty (슬관절 전치환술 후 기능 회복을 위한 치료법)

  • Kim, Young-mo;Joo, Yong-bum;Park, Il-young
    • Journal of the Korean Orthopaedic Association
    • /
    • 제55권2호
    • /
    • pp.117-126
    • /
    • 2020
  • Total knee arthroplasty is performed widely in degenerative arthritis of the knee joint, and the frequency of use is increasing. Efforts should be made to achieve functional recovery, such as returning to daily life, and the recovery of strength and range of motion after surgery. The procedure should be approached from a range of perspectives, such as patient factors, surgical technique and rehabilitation. The patient's age, degree of obesity, sex, and strength of the quadriceps muscle can affect the functional recovery after surgery. In addition, the patient's mental state, such as expectation value and satisfaction, can also have an effect. For functional recovery, patient education, pain control, and strengthening of the quadriceps muscle can be performed prior to surgery. Postoperative physiotherapy, such as icing and compression, transcutaneous electrical nerve stimulation therapy, neuromuscular electrical stimulation therapy, low frequency low intensity magnetic field therapy, strengthening of quadriceps muscle, and range of motion exercise can also be applied. In recent years, hydrotherapy, which restores the strength and balance of the leg, is being performed increasingly. These treatments are not only performed shortly after surgery, but are also performed continuously. In addition, the surgeon should apply it appropriately considering the patient's condition, compliance, and social and psychological conditions.