• Title/Summary/Keyword: Magnetic device

Search Result 936, Processing Time 0.023 seconds

Review of low-noise radio-frequency amplifiers based on superconducting quantum interference device

  • Lee, Y.H.;Chong, Y.;Semertzidis, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.1-6
    • /
    • 2014
  • Superconducting quantum interference device (SQUID) is a sensitive detector of magnetic flux signals. Up to now, the main application of SQUIDs has been measurements of magnetic flux signals in the frequency range from near DC to several MHz. Recently, cryogenic low-noise radio-frequency (RF) amplifiers based on DC SQUID are under development aiming to detect RF signals with sensitivity approaching quantum limit. In this paper, we review the recent progress of cryogenic low-noise RF amplifiers based on SQUID technology.

Characteristic of a Superconducting Magnet for 3MJ SMES (3MJ SMES용 초전도 마그네트 특성연구)

  • 김해종;성기철;조전욱;배준한;김석환;심기덕;이언용;김해준;권영길
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.11
    • /
    • pp.572-576
    • /
    • 2003
  • For quite a long time various researches and developments of superconducting magnetic energy storage(SMES) device have been done for enhancement of power qualify control of sensitive electric load. This paper describes the design. fabrication and experimental results for the 3MJ SMES magnet made by using the design code of a SMES device that we developed. A computer code was developed to find the parameters of the SMES magnet which has minimum amount of superconductor for the same stored energy, and the 3MJ SMES magnet was designed based upon that. And the 3MJ SMES magnet designed based upon those. In addition, 3MJ SMES magnet was made based on several research results which were ramp up to 1㎄ without quench.

An optical micro-magnetic device: magnetic-spatial light modulator

  • Inoue, Mitsuteru;Cho, J.K.;Park, J.H.;Uchida, H.;Nishimura, K.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.13-13
    • /
    • 2002
  • A Spatial light modulator (SLM) is a real-time programmable device having the modulation function of the amplitude, phase or polarization of an optical wavefront as a function of position via electrical or optical control signals. Various types of reusable SLMs with two-dimensional pixel arrays are centrally important devices in volumetric recording, data processing, pattern recognition, optical computer and other optical system. (omitted)

  • PDF

Position Detection of a Capsule-type Endoscope by Magnetic Field Sensors (자계 센서를 이용한 캡슐형 내시경의 위치 측정)

  • Park, Joon-Byung;Kang, Heon;Hong, Yeh-Sun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.6
    • /
    • pp.66-71
    • /
    • 2007
  • Development of a locomotive mechanism for the capsule type endoscopes will largely enhance their ability to diagnose disease of digestive organs. As a part of it, there should be provided a detection device of their position in human organs for the purpose of observation and motion control. In this paper, a permanent magnet outside human body was employed to project magnetic field on a capsule type endoscope, while its position dependent flux density was measured by three hall-effect sensors which were orthogonally installed inside the capsule. In order to detect the 2-D position data of the capsule with three hall-effect sensors including the roll, pitch and yaw angle, the permanent magnet was extra translated during the measurement. In this way, the 2-D coordinates and three rotation angles of a capsule endoscope on the same motion plane with the permanent magnet could be detected. The working principle and performance test results of the capsule position detection device were introduced in this paper showing that they could be also applied to 6-DOF position detection.

Control and Display Device of Underground Object Detect system (지하매설물 탐지시스템의 제어 및 표시장치)

  • 서정만;정순기
    • Journal of the Korea Society of Computer and Information
    • /
    • v.6 no.3
    • /
    • pp.35-43
    • /
    • 2001
  • Imposing electromagnetic field using transmitter of buried metal object in skill that detect underground object sensing person atonement in being widowed on the land being magnetized upside numerical value of buried metal object searching way used most widely current by skill be. This paper proposed about mode and detection system of underground object that sense the changed magnetic and judge real radish buried metal object sign of the cook because this treatise forms magnetic in land and design and composition of display device. Also, through simulation of detection system of underground object, showed that can measure radish judgment sign of the cock of underground object

  • PDF

Pelvic Actinomycosis Mimicking Malignancy of the Uterus: a Case Report

  • Shin, Dahye;Hwang, Jiyoung;Hong, Seong Sook;Lee, Eun Ji;Kim, Yon Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.136-141
    • /
    • 2019
  • Pelvic actinomycosis is an uncommon infectious disease. It induces a chronic, suppurative illness characterized by an infiltrative and granulomatous response and, thus, the clinical and radiologic findings may mimic other inflammatory and neoplastic conditions. A 56-year-old female with a long-standing intrauterine device was diagnosed with pelvic actinomycosis manifesting as a large uterine mass with locally infiltrative spread into surrounding tissue that mimicked uterine malignancy. Actinomyces israelii infection was confirmed with a surgical specimen, and the patient was treated with antibiotic medication. Pelvic actinomycosis must be included in the differential diagnoses of patients with an infiltrative pelvic mass extending across tissue planes or in patients with findings of multiple microabscesses, particularly in a patient with an intrauterine device, even the lesion primarily involves the uterus.

Finite Element Analysis and Dynamics Simulation of Mechanical Flux-Varying PM Machines with Auto-Rotary PMs

  • Huang, Chaozhi;Zhang, Zhixuan;Liu, Xiping;Xiao, Juanjuan;Xu, Hui
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.744-750
    • /
    • 2019
  • A new type of auto-rotary PM mechanical flux-varying PM machine (ARPMMFVPMM) is proposed in this paper, which can overcome the problem where the air-gap magnetic field of a PM machine is difficult to freely adjust. The topology structures of the machine and the mechanical flux-adjusting device are given. In addition, the operation principle of flux-adjusting is analyzed in detail. Furthermore, the deformation of a spring with the speed variation is obtained by virtual prototype technology. Electromagnetic characteristics including the flux distribution, air gap flux density, flux linkage, electromagnetic-magnetic-force (EMF), and flux weakening ability are computed by 2D finite element method (FEM). Results show that the machine has some advantages such as the good field control ability.

Magnetic Sensitivity Depending on Width of IrMn Spin Valve Film Device (IrMn 스핀밸브 박막소자의 폭 크기에 의존하는 자장감응도)

  • Choi, Jong-Gu;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.2
    • /
    • pp.41-44
    • /
    • 2010
  • The Cu thickness dependence of magnetic sensitivity for the NiFe/Cu/NiFe/IrMn spin valve multilayer was investigated. The magnetic properties measured by minor MR curves for the Ta(5 nm)/NiFe(8 nm)/Cu(3.5 nm)/NiFe(4 nm)/IrMn(8 nm)/Ta(2.5 nm) multilayer is MR = 1.46 %, MS = 2.0 %/Oe, $H_c\;=\;2.6\;Oe$, and $H_{int}\;=\;0.1\;Oe$. The magnetic sensitivities of GMR-SV devices with ten different widths and a same length of $4.45\;{\mu}m$ by fabricated by photo lithography decreased from 0.3 %/Oe to 0.06%/Oe as from a width of $10\;{\mu}m$ to $1\;{\mu}m$.

Arm Cortex S3C2440 Microcontroller Application for Transcranial Magnetic Stimulation's Pulse Forming on Bax Reactive Cells and Cell Death in Ischemia Induced Rats

  • Tac, Han-Ho;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.266-272
    • /
    • 2016
  • Transcranial magnetic stimulation devices has been used mainly for diagnostic purposes by measuring the functions of the nervous system rather than for treatment purposes, and has a problem of considerable energy fluctuations per repeated pulse. The majority of strokes are caused by ischemia and result in brain tissue damage, leading to problems of the central nervous system including hemiparesis, dysfunction of language and consciousness, and dysfunction of perception. Control is difficult and the size is large due to the difficulty of digitalizing the energy stored in a capacitor, and there are many heavy devices. In addition, there are many constraints when it is used for a range of purposes such as head and neck diagnosis, treatment and rehabilitation of nerve palsy, muscle strengthening, treatment of urinary incontinence etc. Output stabilization and minimization of the energy variation rate are required as the level of the transcranial magnetic stimulation device is dramatically improved and the demand for therapeutic purposes increases. This study developed a compact, low cost transcranial magnetic stimulation device with minimal energy variation of a high repeated pulse and output stabilization using a real time capacitor charge discharge voltage. Ischemia was induced in male SD rats by closing off the common carotid artery for 5 minutes, after which the blood was re-perfused. In the cerebrum, the number of PARP reactive cells after 24 hours significantly decreased (p < 0.05) in the TMS group compared to the GI group. As a result, TMS showed the greatest effect on necrosis-related PARP immuno-reactive cells 24 hours after ischemia, indicating necrosis inhibition, blocking of neural cell death, and protection of neural cells.

Review of progress in electromechanical properties of REBCO coated conductors for electric device applications

  • Shin, Hyung-Seop;Dedicatoria, Marlon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.7-16
    • /
    • 2014
  • Rare-earth barium copper oxide (REBCO) coated conductor (CC) tapes have already been commercialized but still possess some issues in terms of manufacturing cost, anisotropic in-field performance, $I_c$ response to mechanical loads such as delamination, homogeneity of current transport property, and production length. Development on improving its performance properties to meet the needs in practical device applications is underway and simplification of the tape's architecture and manufacturing process are also being considered to enhance the performance-cost ratio. As compared to low temperature superconductors (LTS), high temperature superconductor (HTS) REBCO CC tapes provide a much wider range of operating temperature and a higher critical current density at 4.2 K making it more attractive in magnet and coil applications. The superior properties of the REBCO CC tapes under magnetic field have led to the development of superconducting magnets capable of producing field way above 23.5 T. In order to achieve its optimum performance, the electromechanical properties under different deformation modes and magnetic field should be evaluated for practical device design. This paper gives an overview of the effects of mechanical stress/strain on $I_c$ in HTS CC tapes due to uniaxial tension, bending deformation, transverse load, and including the electrical performance of a CC tape joint which were performed by our group at ANU in the last decade.