• Title/Summary/Keyword: Magnetic analysis

Search Result 4,752, Processing Time 0.035 seconds

Isolation and Characterization of Microsatellites in the Brown Planthopper, Nilaparvata lugens $St{\aa}l$ (벼멸구(Nilaparvata lugens)에서 마이크로새털라이트 마커의 분리 및 특성검정)

  • Mun Jeomhee;Song Yoo Han;Roderick George K.
    • Korean journal of applied entomology
    • /
    • v.43 no.4 s.137
    • /
    • pp.311-315
    • /
    • 2004
  • The brown planthopper, Nilaparvata lugens, is among the most serious insect pests of rice. It is widely distributed in Asia, Australia and Pacific islands. An earlier mitochondrial DNA study revealed that there exist significant genetic differences between populations north and south of the Red River Delta region in Vietnam. However the mitochondrial DNA was not sufficiently variable to examine the sources of immigration. For a more detailed analysis of geographic population structure of N. lugens, we developed microsatellite markers. Thirty-seven putative microsatellite loci were isolated using a magnetic biotin method, and five primer pairs designed from the flanking regions of sequenced microsatellite clones were labeled with fluorescent. Of these five primer sets, two have proven to be useful across all the samples we used in this study. We used variation at these two microsatellite loci to test the hypothesis that N. lugens biotypes (1, 2, and 3) sampled from laboratory selection constituted distinct genetic units. Allele frequency differences among the three major biotype categories were not significantly different at one locus (27035). However, the other (7314) did show differences among the major three biotypes. The methods we describe here will be useful for studying population structure of crop pest and for tracking the patterns of migratory pest like the rice planthoppers.

Analysis and Application of Compact Planar Multi-Loop Self-Resonant Coil of High Quality Factor with Coaxial Cross Section (고품질 계수를 갖는 소형 평판형 동축 단면 다중 루프 자기 공진 코일 해석 및 응용)

  • Son, Hyeon-Chang;Kim, Jinwook;Kim, Do-Hyeon;Kim, Kwan-Ho;Park, Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.4
    • /
    • pp.466-473
    • /
    • 2013
  • In this paper, a compact planar multi-loop self-resonant coil of high quality factor with a coaxial cross section is proposed for effective wireless charging. The proposed coil has high Q-factor and a resonant frequency of a coil can be easily controlled by adjusting distributed capacitance. For designing the coil, a self-inductance and a distributed capacitance are calculated theoretically. The self-inductance is calculated from the sum of the mutual energies between small circular loops that are made by dividing the cross section of the coil. To verify its properties and calculation results, the self-resonant coils are fabricated by using a coaxial cable with characteristic impedance of $50{\Omega}$. The measured frequencies are very consistent with the calculated ones. In addition, the resonant frequency can be adjusted slightly by the tuning parameter ${\gamma}$. The resonant coils are applied to a tablet PC, the Q-factors of the Tx and Rx resonant coils are 282 and 135, respectively. As a result of measurement when height between the two resonant coils is 4.4 cm, the power transfer efficiency is more than 80 % within a radius of 5 cm.

Changes in the Volume and Cortical Thickness of the Specific Regions of Cerebellum of Patients with Major Depressive Disorder (주요우울장애 환자에서 소뇌 국소 부위의 부피와 피질 두께의 차이)

  • Kang, Ji-Won;Han, Kyu-Man;Won, Eunsoo;Tae, Woo-Suk;Ham, Byung-Joo
    • Korean Journal of Biological Psychiatry
    • /
    • v.25 no.3
    • /
    • pp.60-71
    • /
    • 2018
  • Objectives A growing body of evidence has suggested that morphologic changes in cerebellum may be implicated with pathophysiology of major depressive disorder (MDD). The aim of this study is to investigate a difference in the volume and cortical thickness of the specific region of cerebellum between patients with MDD and healthy controls (HC). Methods A total of 127 patients with MDD and 105 HC participated in this study and underwent T1-weighted structural magnetic resonance imaging. We analyzed volume and cortical thickness of each twelve cerebellum regions divided by left and right and the volume and cortical thickness of the whole cerebellum from T1-weigted image of participants. One-way analysis of covariance was used to investigate the volume and cortical thickness difference of total and specific regions between two groups adjusting for age, gender, medication, and total intracranial cavity volume. Results We found that the patients with MDD had significantly greater volume in the left cerebellum lobule III region [false discovery rate (FDR)-corrected p = 0.034] compared to HC. Also, our findings indicate that cortical thickness of left lobule VIIB (FDR-corrected p = 0.032) and lobule VIIIB (FDR-corrected p = 0.032) are significantly thinner in the patients with MDD compared with the HC. No significant volume and cortical thickness differences were observed in other sub-regions of the cerebellum. The volumes and cortical thickness of whole cerebellum between patients with MDD and HC did not differ significantly. Conclusions We observed the region-specific volume and cortical thickness difference in cerebellum between the patients with MDD and HC. The results of our study implicate that the information about structural alterations in cerebellum with further replicative studies might provide a stepping stone toward a specific marker to diagnose MDD.

  • PDF

A Fibrin Matrix Promotes the Differentiation of EMSCs Isolated from Nasal Respiratory Mucosa to Myelinating Phenotypical Schwann-Like Cells

  • Chen, Qian;Zhang, Zhijian;Liu, Jinbo;He, Qinghua;Zhou, Yuepeng;Shao, Genbao;Sun, Xianglan;Cao, Xudong;Gong, Aihua;Jiang, Ping
    • Molecules and Cells
    • /
    • v.38 no.3
    • /
    • pp.221-228
    • /
    • 2015
  • Because Schwann cells perform the triple tasks of myelination, axon guidance and neurotrophin synthesis, they are candidates for cell transplantation that might cure some types of nervous-system degenerative diseases or injuries. However, Schwann cells are difficult to obtain. As another option, ectomesenchymal stem cells (EMSCs) can be easily harvested from the nasal respiratory mucosa. Whether fibrin, an important transplantation vehicle, can improve the differentiation of EMSCs into Schwann-like cells (SLCs) deserves further research. EMSCs were isolated from rat nasal respiratory mucosa and were purified using anti-CD133 magnetic cell sorting. The purified cells strongly expressed HNK-1, nestin, $p75^{NTR}$, S-100, and vimentin. Using nuclear staining, the MTT assay and Western blotting analysis of the expression of cell-cycle markers, the proliferation rate of EMSCs on a fibrin matrix was found to be significantly higher than that of cells grown on a plastic surface but insignificantly lower than that of cells grown on fibronectin. Additionally, the EMSCs grown on the fibrin matrix expressed myelination-related molecules, including myelin basic protein (MBP), 2',3'-cyclic nucleotide 3'-phosphodiesterase (CNPase) and galactocerebrosides (GalCer), more strongly than did those grown on fibronectin or a plastic surface. Furthermore, the EMSCs grown on the fibrin matrix synthesized more neurotrophins compared with those grown on fibronectin or a plastic surface. The expression level of integrin in EMSCs grown on fibrin was similar to that of cells grown on fibronectin but was higher than that of cells grown on a plastic surface. These results demonstrated that fibrin not only promoted EMSC proliferation but also the differentiation of EMSCs into the SLCs. Our findings suggested that fibrin has great promise as a cell transplantation vehicle for the treatment of some types of nervous system diseases or injuries.

Three Cases of Mitochondrial Disorders in the Neonatal Period (신생아기에 진단된 미토콘드리아 질환 3례)

  • Kim, Yoon-Hee;Lee, Young-Mock;Namgung, Ran;Kim, Jeong-Eun;Lee, Soon-Min;Park, Kook-In;Kim, Se-Hoon;Lee, Jin-Sung
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.254-261
    • /
    • 2010
  • Little is known about neonatal mitochondrial disease, though mitochondrial metabolic disorders may often present in the neonatal period because of the high energy requirement of neonate. In newborn period, common presentations are not specific and the disease course may be rapid and fatal. In this study, we report three cases of neonatal mitochondrial disease. The first case was strongly suspected because of sudden seizure and mental change with severe lactic acidosis, and multiorgan failure. Plasma lactate/pyruvate (L/P) ratio was increased to 55.6 with marked lactic aciduria and increased plasma alanin up to 2,237 nmol/mL. In the second patient, a peritoneal dialysis was performed for acute adrenal and renal failure, but metabolic acidosis persisted. Plasma L/P ratio was increased to 23.9, and MRC I (mitochondrial respiratory chain defect) was diagnosed through the enzymatic analysis of the muscles. The third case showed repetitive episode of lactic acidosis during the first two months of life, hypotonia, failure to thrive and feeding difficulties. We found markedly increased cerebrospinal fluid L/P ratio up to 57 though plasma L/P ratio(19.4) was borderline with increased plasma lactate. The lactate peak was prominent in brain magnetic resonance spectroscopy (MRS). MRC II was confirmed through muscle biopsy. Plasma lactate level and lactate peak of brain MRS were normalized after conservative treatment.

Precise Detection of Buried Underground Utilities by Non-destructive Electromagnetic Survey (비파괴 전자탐사에 의한 지하 매설물의 정밀탐지)

  • Shon, Ho-Woong;Lee, Seung-Hee;Lee, Kang-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.3
    • /
    • pp.275-283
    • /
    • 2002
  • To detect the position and depth of buried underground utilities, method of Ground Penetrating Radar(GPR) survey is the most commonly used. However, the skin-depth of GPR is very shallow, and in the places where subsurface materials are not homogeneous and are compose of clays and/or salts and gravels, GPR method has limitations in application and interpretation. The aim of this study is to overcome these limitations of GPR survey. For this purpose the site where the GPR survey is unsuccessful to detect the underground big pipes is selected, and soil tests were conducted to confirm the reason why GPR method was not applicable. Non-destructive high-frequency electromagnetic (HFEM) survey was newly developed and was applied in the study area to prove the effectiveness of this new technique. The frequency ranges $2kHz{\sim}4MHz$ and the skin depth is about 30m. The HFEM measures the electric field and magnetic field perpendicular to each other to get the impedance from which vertical electric resistivity distribution at the measured point can be deduced. By adopting the capacitive coupled electrodes, it can make the measuring time shorter, and can be applied to the places covered by asphalt an and/or concrete. In addition to the above mentioned advantages, noise due to high-voltage power line is much reduced by stacking the signals. As a result, the HFEM was successful in detecting the buried underground objects. Therefore this method is a promising new technique that can be applied in the lots of fields, such as geotechnical and archaeological surveys.

Identification of NMR Data for ginsenoside Rg1 (Ginsenoside Rg1의 NMR 데이터 동정)

  • Lee, Dae-Young;Cho, Jin-Gyeong;Lee, Min-Kyung;Lee, Jae-Woong;Park, Hee-Jeong;Lee, Youn-Hyung;Yang, Deok-Chun;Baek, Nam-In
    • Journal of Ginseng Research
    • /
    • v.32 no.4
    • /
    • pp.291-299
    • /
    • 2008
  • The fresh ginseng roots were extracted in aqueous methanol (MeOH), and the obtained extracts were partitioned using ethyl acetate (EtOA), n-butanol (n-BuOH), and water, successively. The repeated silica gel column chromatography for n-BuOH fraction afforded a purified ginsenoside $Rg_1$. The physico-chemical, spectroscopic and chromatographic data of ginsenoside $Rg_1$, such as crystallization characteristics, melting point, specific rotation, infrared spectrometry (IR) data, fast atom bombardment/mass spectrometry (FAB/MS) data, nuclear magnetic resonance (NMR) data, retention factor (Rf) in thin layer chromatography (TLC) experiment, and retention time (r.t.) in HPLC analysis, were measured and compared with those reported in literatures. Especially, the previous literatures reported different data for ginsenoside $Rg_1$ in the $^{1}H-$ and $^{13}C$-NMR experiments. This paper gives the exactly assigned NMR data through 2D-NMR experiments, such as $^{1}H-^{1}H$ correlation spectroscopy (COSY), hetero nuclear single quantum correlation (HSQC), and hetero nuclear multiple bond connectivity (HMBC).

Comparative Studies of Methods for Continuation and Derivatives of Potential Fields (포텐셜장(場)의 상하향연속(上下向連續) 및 미분법(微分法)에 대(對)한 비교연구(比較硏究))

  • Kwon, Byung Doo
    • Economic and Environmental Geology
    • /
    • v.14 no.2
    • /
    • pp.93-102
    • /
    • 1981
  • Studies of model potential fields continued upward and downward show differences depending on the method of continuation. Beginning with a magnetic field computed over a buried vertical cylinder, the field was continued to various levels by a method introduced by Henderson (Lagrangian interpolation) and by a spectral method (frequency domain analysis). Resultant fields show (1) no significant differences in upward continued values, (2) in downward continuation, accurate values are obtained with the spectral method over the central part of the anomaly, and (3) accurate values are obtained with Henderson's method on the flanks of the anomaly, while oscillations usually characterize the spectral method in this region. Essentially the same observations are made for derivative calculations. Field oscillations are empirically predicted at levels continued to approximately two-thirds of the depth of the source. Our spectral computer program output yields marked oscillations at one-half of the depth of the source. Henderson's method shows no oscillations at this depth and only minor oscillations at the top of the body (some negative values appear on the flanks of the anomaly). The Henderson output is a smooth field even if continued below the top of the body. These results suggest that the presence of oscillations cannot be used to identify the top of a buried source without careful consideration of the method used to continue the field. Use of the derivative to outline and isolate anomalies must similarly include consideration of the method of calculation.

  • PDF

A Case of Mucopolysaccharidosis Type 2 Diagnosed Early through Brain MRI (뇌자기공명영상 검사를 통해 조기 발견된 제2형 뮤코다당증 1례)

  • Lee, Yoon kyoung;Cho, Sung Yoon;Kim, Jinsup;Huh, Rimm;Jin, Dong-Kyu
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • Mucopolysaccharidosis (MPS) is an inherited disease entity associated with lysosomal enzyme deficiencies. MPS type 2, also known as Hunter syndrome, has a characteristic morphology primarily involving x-l inked recessive defects and iduronate-2-sulfatase gene mutation. The purpose of this case report is to provide important clues to help pediatricians identify Hunter syndrome patients earlier (i.e., before the disease progresses). A 30-month-old boy showed developmental delay and decreased speech ability. Physical examinations revealed a flat nose and extensive Mongolian spots. Brain magnetic resonance images (MRIs) showed bilateral multiple patchy T2 hyperintense lesions in the periventricular and deep white matter, several cyst-like lesions in the body of the corpus callosum, and diffuse brain atrophy, which were in keeping with the diagnosis. Based on these findings, the patient was suspected of having MPS. In the laboratory findings, although the genetic analysis of IDS (Iduronate-2-sulfatase) did not show any pathogenic variant, the enzymatic activity of IDS was not detected. We could confirm the diagnosis of MPS, because other sulfatases, such as ${\alpha}$-L-iduronidase, were detected in the normal range. Early enzymatic replacement therapy is essential and has a relatively good prognosis. Therefore, early diagnosis should be made before organ damage becomes irreversible, and brain MRIs can provide additional diagnostic clues to help distinguish the disorder.

Detection of Rapid Atrial Arrhythmias in SQUID Magnetocardiography (스퀴드 심자도 장치를 이용한 심방성 부정맥의 측정)

  • Kim Kiwoong;Kwon Hyukchan;Kim Ki-Dam;Lee Yong-Ho;Kim Jin-Mok;Kim In-Seon;Lim Hyun-Kyoon;Park Yong-Ki;Kim Doo-Sang;Lim Seung-Pyung
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.28-35
    • /
    • 2005
  • We propose a method to measure atrial arrhythmias (AA) such as atrial fibrillation (Afb) and atrial flutter (Afl) with a SQUID magnetocardiograph (MCG) system. To detect AA is one of challenging topics in MCG. As the AA generally have irregular rhythm and atrio-ventricular conduction, the MCG signal cannot be improved by QRS averaging; therefore a SQUID MCG system having a high SNR is required to measure informative atrial excitation with a single scan. In the case of Afb, diminished f waves are much smaller than normal P waves because the sources are usually located on the posterior wall of the heart. In this study, we utilize an MCG system measuring tangential field components, which is known to be more sensitive to a deeper current source. The average noise spectral density of the whole system in a magnetic shielded room was $10\;fT/{\surd}Hz(a)\;1\;Hz\;and\;5\;fT/{\surd}Hz\;(a)\;100\;Hz$. We measured the MCG signals of patients with chronic Afb and Afl. Before the AA measurement, the comparison between the measurements in supine and prone positions for P waves has been conducted and the experiment gave a result that the supine position is more suitable to measure the atrial excitation. Therefore, the AA was measured in subject's supine position. Clinical potential of AA measurement in MCG is to find an aspect of a reentry circuit and to localize the abnormal stimulation noninvasively. To give useful information about the abnormal excitation, we have developed a method, separative synthetic aperture magnetometry (sSAM). The basic idea of sSAM is to visualize current source distribution corresponding to the atrial excitation, which are separated from the ventricular excitation and the Gaussian sensor noises. By using sSAM, we localized the source of an Afl successfully.

  • PDF