• Title/Summary/Keyword: Magnetic Saturation

Search Result 772, Processing Time 0.022 seconds

Characteristics and design parameter deduction of hybrid thrust magnetic bearing (하이브리드 스러스트 마그네틱 베어링의 설계 파라미터 도출 및 특성해석)

  • Jang, Seok-Myeong;Lee, Un-Ho;Ko, Kyoung-Jin;Choi, Ji-Hwan;Sung, So-Young;Lee, Yong-Bok
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.52-54
    • /
    • 2009
  • This paper deals with design parameters deduction and analysis of hybrid magnetic bearing. Using the solutions obtained from equivalent magnetic circuit, we predict the electromagnetic characteristics from permanent magnet and electromagnet and obtain the initial parameters. And then, using non-linear finite element analysis, a detailed design is performed considering saturation and asymmetry of flux density at the surface in order to meet requirements.

  • PDF

Effects of Flux Treatment on the Glass Forming Ability and Magnetic Properties of Fe-based Ternary Amorphous Alloys

  • Zuo, Mingqing;Yi, Seonghoon
    • Journal of Korea Foundry Society
    • /
    • v.40 no.4
    • /
    • pp.113-117
    • /
    • 2020
  • A series of Fe-P-B and Fe-Si-B amorphous alloys with high Fe contents exceeding 90 wt.% was successfully prepared by combining flux treatment and melt-spinning technique. The effects of Fe content and the flux treatment on the thermal and magnetic properties of amorphous alloys were studied. The glass-forming ability and the thermal stability of amorphous ribbons can be improved by a flux treatment, revealing the effective removal of heterogeneous nucleation sites in the ribbons through the flux treatment. It was found that Fe-Si-B ribbons exhibit higher saturation magnetization levels than Fe-P-B ribbons.

Strategic Utilization of Soft Magnetic Composite in a High-Speed Switched Reluctance Machine Depending on a Loss Pattern (손실 패턴에 따른 고속 스위치드 릴럭턴스 전동기의 SMC 분말을 이용한 효율 개선)

  • Lee, Cheewoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.323-327
    • /
    • 2017
  • Soft magnetic composite (SMC) material has recently received a significant attention in the area of high-speed machines because of its unique properties such as good design flexibility and low eddy current loss. However, SMC's electromagnetic property is poor compared to silicon steel in terms of saturation, relative permeability, and hysteresis loss. This paper presents a technique for utilization of SMC in two strategic designs of a switched reluctance machine (SRM) depending on a loss pattern. To investigate the effect of SMC's merits and demerits, the stator material is changed from laminated steel to SMC.

Nonlinear Analysis of Hybrid Stepping Motor using 3D Equivalent Magnetic Circuit Network Method (3차원 등가자기회로방법을 이용한 하이브리드 스태핑 모터의 비선형 해석)

  • Jin, C.S.;Kim, S.;Lee, J.;Kim, Y.T.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.131-133
    • /
    • 2001
  • 2D analysis is impossible for Hybrid stepping motor(HSM) and 3D analysis is necessary because the permanent magnet is magnetized to the axial direction. In this paper, the characteristics of HSM are analyzed by using 3D equivalent magnetic circuit network method(3D EMCNM). In addition, the trapezoidal element is introduced for the exact permeance calculation in the complex shape machinery such as HSM. The magnetic saturation of core is considered.

  • PDF

The Analysis of Transient currents in a Magnetic coupling High-Tc superconducting Fault Current Limiter (자기결합형 고온초전도한류기의 과도전류 해석)

  • Joo, Min-Seok;Chu, Yong;Yim, Do-Hyun;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.24-26
    • /
    • 1995
  • In this paper, we investigated transient fault currents in a magnetic coupling High-Tc superconducting current limiter(HCL). It has an important effect on the reliability and stability of the power system. In order to analyze transient fault characteristics of HCL, we fabricated a magnetic coupling HCL and tested it in different fault conditions. An important parameter of design and manufacture which makes HCL inherently reliable is reduction of inrush fault currents. Without inrush fault currents, the currents flowing under such conditions can be limited to a desired-value within one cycle. Inrush fault current depends on saturation, normal spot propagation velocity, turns ratio and the fault angle.

  • PDF

Minireview on Recent Antibody-Related NMR Studies

  • Jang, Jinhwa;Kim, Ji-Hun
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.24 no.4
    • /
    • pp.129-135
    • /
    • 2020
  • In a relatively short period, monoclonal antibodies have made dramatic success as therapeutics for various diseases such as cancers and autoimmune diseases and become an important development items for many pharmaceutical companies. In order to develop antibody drug, it is important to investigate the structural characteristics of both antibody and antigen. NMR studies on antibody are extremely challenging due to big huddles such as a big size of protein and isotope labeling, nevertheless, several studies have been reported in 10 years. Here, we analyzed 95 papers dealing with antibody-related NMR studies reported in recent 10 years. We categorized papers into 3 types: 1) structural characterization of antibody, 2) structural characterization of antigen using antibody, 3) amyloidosis caused by fragment of antibody. This work would shed new light on antibody-related NMR studies.

Magnetic Interaction and Magnetic Properties of Electrodeposited CoPt Magnetic Films with Different Thickness (전기도금법으로 제작한 CoPt 자성막의 자기상호작용과 자기적 성질)

  • Kim, Hyeon-Soo;Lee, Jong-Duck;Jeong, Soon-Young;Lee, Chang-Hyeong;Suh, Su-Jeong
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.5
    • /
    • pp.151-156
    • /
    • 2011
  • The influence of thickness on magnetic interaction and magnetic properties in electrodeposited CoPt magnetic films was investigated from the analysis of the magnetic remanence curves and the magnetic hysteresis loops. As the thickness of the CoPt film is increased, the perpendicular coercivity and the saturation magnetization are increased but the squareness is considerably decreased. The analysis results of the magnetic remanence curves and the magnetic hysteresis loops exhibited that the dipolar interaction is the main interaction mechanism for all samples, but the strength of the dipolar interaction gradually increased with increasing sample thickness.

Soft Magnetic Properties of CoFeAlO Thin Films for Ultrahigh Frequency Applications (고주파용 CoFeAlO계 박막의 자기적 특성)

  • Kim, Hyeon-Bin;Yun, Dae-Sik;Ha, N.-D.;Kim, Jong-O
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.1
    • /
    • pp.17-20
    • /
    • 2005
  • The influence of $O_2$ partial pressure on saturation mgnetization, coercivity, anisotropy field and effective permeability (over 1GHz) of as-deposited Co-Fe-Al-O thin films, which were fabricated by RF magnetron reactive sputtering method, were investigated. The $Co_{69.9}Fe_{20.5}A_{14.4O_{5.2}$ thin film fabricated at $O_2$ partial pressure of 4% exhibits the best magnetic softness with saturation magnetization 4${$pi}$Ms of 18.1 kG, coercivity of 0.82 Oe, anisotropy field ($H_k$) of Oe, and effective permeability (${\mu}_{eff}$) about 1,024 above 1 GHz. the electrical resistivity of Co-Fe-Al-O thin films were increased with increasing $O_2$ partial pressure, the electrical resistivity of $Co_{69.9}Fe_{20.5}A_{14.4O_{5.2}$ thin film with the best soft magnetic properties was 560.7 ${\mu}{\Omega}$am. Therefore, It is assumed that the good soft magnetic properties of $Co_{69.9}Fe_{20.5}A_{14.4O_{5.2}$ thin film results from high electrical resistivity and large anisotropy field.

The Influence of $O_2$ Partial Pressure on Soft Magnetic Properties of As-deposited Fe-Sm-O Thin Films (산소분압에 따른 Fe-Sm-O계 박막의 연자기적 성질)

  • Yoon, T.S.;Cho, W.S.;Koo, E.S.;Li, Ying;Park, J.B.;Kim, C.O.
    • Korean Journal of Materials Research
    • /
    • v.10 no.11
    • /
    • pp.755-759
    • /
    • 2000
  • The influence of $O_2$partial presure on saturation magnetization, coercivity and effective permeability(0.5~100MHz) of as-deposited Fe-Sm-O thin films, which were fabricated by RF magnetron reactive sputtering method, were investigated. The nanocrystalline Fe(sub)83.4Sm(sub)3.4O(sub)13.2 thin film fabricated at $O_2$partial pressure of 5% exhibits the best magnetic softness with saturation magnetization of 18kG, coercivity of 0.82 Oe and effective permeability about 2,600 at 0.5~100MHz. $\alpha$-Fe grain size is decreased with increasing $O_2$partial pressure. In case of $O_2$partial pressure of 10%, it is observed that FeO compound is formed and soft magnetic properties are decreased. The electrical resistivity of Fe-Sm-O thin films were increased with increasing $O_2$partial pressure, the electrical resistivity of Fe(sub)83.4Sm(sub)3.4O(sub)13.2 thin film with the best soft magnetic properties was 130 $\mu$$\Omega$cm. Therefore, It is assumed that the good soft magnetic properties of Fe(sub)83.4Sm(sub)3.4O(sub)13.2 thin film results from high electrical resistivity and decreasing $\alpha$-Fe grain size due to precipitation of Sm-Oxide phase.

  • PDF

Design of an Inductive Coupler for Power Transmission line (송전선용 대용량 신호결합장치의 설계)

  • Kim, H.S.;Byun, W.B.;Kim, J.R.;Bae, E.R.;Lee, D.C.;Lee, H.Y.;Lee, J.H.;Ji, M.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.439-440
    • /
    • 2008
  • An inductive coupler, which feeds communication to the electric power transmission line, is required to establish Power Line Communication(PLC). The electro-magnetic property of magnetic core and design technology for coupler are very important to manufacture an inductive coupler for power transmission line. The magnetic core with superior electro-magnetic property was manufactured by using nano-crystalline alloy and an inductive coupler, which can operate at the maximum 2,000 A current, was designed and manufactured by establishment of current saturation, signal out winding, and electro-magnetic simulation in this study. Communication speed of 14 Mbps in 600 m communication distance of the real electric power transmission line was obtained by using the inductive coupler and application possibility of the inductive coupler for the electric power transmission line was certified.

  • PDF