• Title/Summary/Keyword: Magnetic Resonance Imaging/methods

Search Result 1,454, Processing Time 0.044 seconds

Usefulness of Dual-Echo in Steady State (DESS) Image in Chondromalacia of Knee Joint: Comparison of DESS and Turbo Spin-Echo MR Images (슬관절 연골 연화증의 진단에서의 Dual Echo in Steady State (DESS) 영상의 유용성 : 급속 스핀에코 자기공명 영상과 비교)

  • 윤삼현;하두회
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.66-72
    • /
    • 1999
  • Purpose : To evaluate the usefulness of Dual Echo in Steady State(DESS) image in the diagnosis of chondromalacia of the knee compared with turbo spin-echo MR images Materials and Methods : We included 26 patients with chondromalacia of the knee. MR imaging was obtained with a 1.5T imager. Sagittal and coronal double echo T2 weighted images(TR/TE 3000-4200/16-96msec, FOV $140-160{\times}140-160mm$, matrix size $180{\times}256$, slice thickness 4.0mm, interslice gap 0.5mm), and sagittal DESS image(TR/TE 25.4/9.0msec, flip angle $35-45^{\circ}$, FOV $150-160{\times}150-160mm,{\;}matrix{\;}size{\;}192{\times}256$, effective slice thickness 1.5mm) were obtained. Cartilage lesions were staged according to a modified scheme proposed by Outerbirdge: grade 0, normal; grade 1, softening or/and swelling; grade 2, mild surface fibrillation or/and less than 50% of cartilage thickness; grade 3, severe surface fibrillation or/and loss of more than 50% of cartilage thickness but without exposure of subchondral bone; and grade 4, complete loss of cartilage with subchondral bone exposure. Gradings were determined by two readers with consensus, and patellofemoral, medial and lateral tibiofemoral compartments were evaluated. Results : Arthroscopic findings revealed grade 1 in seven cases, grade 2 in 21 cases, grade 3 in six cases, and grade 4 in 18 cases. Sensitivity of turbo spin-echo MR image was as follows; 0%, 14%, 0%, 61% in each grade, and sensitivity of DESS image was as follows; 0%, 33%, 50%, 67%, in each grade(p=0.001). In the detection of chondromalacic lesions regardless of gradings, sensitivity, specificity and accuracy of conventional MR image were 59.6% 88.6% 78.8%, and of DESS image, 73.1% 88.4%, 82.2%(p=0.007). Conclusion : For chondromalacia of knee joints, DESS images showed higher sensitivity than turbo spin-echo MR images. Therefore, DESS images will be helpful for diagnosis of chondromalacia of knee joints.

  • PDF

The Comparison of Susceptibility Changes in 1.5T and3.0T MRIs due to TE Change in Functional MRI (뇌 기능영상에서의 TE값의 변화에 따른 1.5T와 3.0T MRI의 자화율 변화 비교)

  • Kim, Tae;Choe, Bo-Young;Kim, Euy-Neyng;Suh, Tae-Suk;Lee, Heung-Kyu;Shinn, Kyung-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.154-158
    • /
    • 1999
  • Purpose : The purpose of this study was to find the optimum TE value for enhancing $T_2^{*}$ weighting effect and minimizing the SNR degradation and to compare the BOLD effects according to the changes of TE in 1.5T and 3.0T MRI systems. Materials and Methods : Healthy normal volunteers (eight males and two females with 24-38 years old) participated in this study. Each volunteer was asked to perform a simple finger-tapping task (sequential opposition of thumb to each of the other four fingers) with right hand with a mean frequency of about 2Hz. The stimulus was initially off for 3 images and was then alternatively switched on and off for 2 cycles of 6 images. Images were acquired on the 1.5T and 3.0T MRI with the FLASH (fast low angle shot) pulse sequence (TR : 100ms, FA : $20^{\circ}$, FOV : 230mm) that was used with 26, 36, 46, 56, 66, 76ms of TE times in 1.5T and 16, 26, 36, 46, 56, 66ms of TE in 3.0T MRI system. After the completion of scan, MR images were transferred into a PC and processed with a home-made analysis program based on the correlation coefficient method with the threshold value of 0.45. To search for the optimum TE value in fMRI, the difference between the activation and the rest by the susceptibility change for each TE was used in 1.5T and 3.0T respectively. In addition, the functional $T_2^{*}$ map was calculated to quantify susceptibility change. Results : The calculated optimum TE for fMRI was $61.89{\pm}2.68$ at 1.5T and $47.64{\pm}13.34$ at 3.0T. The maximum percentage of signal intensity change due to the susceptibility effect inactivation region was 3.36% at TE 66ms in 1.5T 10.05% at TE 46ms in 3.0T, respectively. The signal intensity change of 3.0T was about 3 times bigger than of 1.5T. The calculated optimum TE value was consistent with TE values which were obtained from the maximum signal change for each TE. Conclusion : In this study, the 3.0T MRI was clearly more sensitive, about three times bigger than the 1.5T in detecting the susceptibility due to the deoxyhemoglobin level change in the functional MR imaging. So the 3.0T fMRI I ore useful than 1.5T.

  • PDF

The Synthesis and MR Properties of New Macromolecular MR Contrast Agent (새로운 거대분자 MR 조영제의 합성 및 MR 특성에 관한 연구)

  • 장용민;장영환;황문정;박현정;전경녀;이종민;배경수;강봉석
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.35-40
    • /
    • 2002
  • Purpose : To evaluate the NMR relaxation properties and imaging characteristics of tissue-specificity for a newly developed macromolecular MR agent. Materials and methods : Phthalocyanine (PC) was chelated with paramagnetic ion, Mn.2.01g (5.2 mmol) of Phthalocyanine was mixed with 0.37g (1.4 mmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography (CHC13/CH3OH 98/2 v/v, Rf, 0.76) to obtain 1.04g (46%) of MnPC (molecular weight= 2000d). The $T1}T2$ relaxivity of MnPC was measured in 1.5T(64 MHz) MR using 0.1 mM MnPC. The MR image characteristics of MnPC was evaluated using spin-echo (TR/TE=500/14 msec) and gradient-echo (FLASH) (TR/TE=80/4 msec, flip angle=60) techniques in 1.57 MR scanner. The images of rabbit liver were obtained every 10 minutes up to 4 hours. To study the effect of concentration on image, 20 mM, 50 mM, 100 mM of MnPC were tested. Results : The relaxivities of MnPC at 1.5T(64MHz) were Rl=7.28 $mM^{-1}S^{-1},{\;}R2=55.56mM^{-1}S^{-1}$. Compared to the values of Gd-DTPA (Rl[=4.8 $mM^{-1}S^{-1})$], R2[=5.2 $mM^{-1}S^{-1}])$]), both T1/T2 relaxivities of MnPC were higher than those of Gd-DTPA. For both of SE and FLASH techniques, the contrast enhancement reached maximum at 10 minutes after bolus injection and the enhancement continued for more than 2 hours. When compared with small molecular weight liver agents such as Gd-EOB-DTPA, Gd-BOPTA and MnDPDP, MnPC was characterized by more prolonged enhancement time. The time course of MR images also revealed biliary excretion of MnPC. Conclusion : We developed a new macromolecular MR agent, MnPC. The relaxivities of MnPC were higher than those of small molecular weight Gd-chelate. Hepatic uptake and biliary excretion of MnPC suggests that this agent is a new liver-specific MR agent.

  • PDF

The Significance and Limitation of MR Volumetry: Comparison between Normal Adults and the Patients with Epilepsy and Hippocampal Sclerosis (MR 부피측정의 의의와 한계: 정상성인과 해마경화증 간질 환자의 비교)

  • 김홍대;장기현;한문희;김현집;이상건;이명철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.47-54
    • /
    • 2002
  • Purpose : Hippocampal atrophy is one of the characteristic pathologic findings of hippocampal sclerosis, for which MR imaging of the hippocampus is essential in the evaluation of hippocampal sclerosis. The purpose of this study is to present the normal MR volumetric data of the hippocampus in normal adult Korean and to compare those with MR volumetric data of hippocampus in patients with hippocampal s-clerosis, providing the diagnostic volume criteria of the hippocampal atrophy. Materials and methods : MR volumetry was performed in 30 normal adults and 28 patients with temporal lobe epilepsy whose final diagnosis was hippocampal sclerosis. The volumetric data were compared between sexes, right and left sides, and normal and abnormal hippocampus, and the volume criteria for the diagnosis of hippocampal atrophy was determined. Results : The mean $volumes({\pm}standard$ deviation) of normal Korean adult were $2.20{\pm}0.73\textrm{cm}^3$ (right) and $2.17{\pm}0.72\textrm{cm}^3$ (left) in male and $2.27{\pm}0.47{\;}\textrm{cm}^3$ (right) and $2.23{\pm}0.48\textrm{cm}^3$ (left) in female. The mean right-left differences were $0.14{\pm}0.11\textrm{cm}^3$ and $0.19{\pm}0.13\textrm{cm}^3$ in male and female, respectively. The MR volumetry showed no significant statistical differences between sexes and between right and left. The mean volume and standard deviation of the hippocampus in hippocampal sclerosis patients was $1.46{\pm}0.60{\;}\textrm{cm}^3$, and the right-left difference was $0.51{\pm}0.41\textrm{cm}^3$, In comparison of two volume distributions between normal adult group and hippocampal sclerosis patients group, the reasonable diagnostic volume criteria was $0.4{\;}\textrm{cm}^3$ as right-left volume difference, in which the sensitivity and specificity are 0.61 and 0.90. In all patients with right-left volume difference more than $0.4{\;}\textrm{cm}^3$, visual determination of unilateral hippocampal atrophy was possible. Conclusion : The MR-based hippocampal volumetry is a useful add-on of visual MR diagnosis, only when visual diagnosis of hippocampal sclerosis is difficult.

  • PDF

Usefulness of DTI-based three dimensional corticospinal tractography in children with hemiplegic cerebral palsy (편마비를 가진 뇌성마비 환아에서 확산 텐서강조영상을 이용한 3차원 피질척수로 영상의 유용성)

  • Yeo, Ji Hyun;Son, Su Min;Lee, Eun Sil;Moon, Han Ku
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.1
    • /
    • pp.99-104
    • /
    • 2009
  • Purpose : Magnetic resonance diffusion tensor imaging-based three-dimensional fiber tractography (DTI-FT) is a new method which demonstrates the orientation and integrity of white matter fibers in vivo. However, clinical application on children with cerebral palsy is still under investigation. We present various abnormal patterns of DTI-FT findings and accordance rate with clinical findings in children with hemiplegic cerebral palsy, to recognize the use fulness of DTI-FT. Methods : The thirteen children with hemiplegic cerebral palsy evaluated at Yeungnam University hospital from March, 2003 to August, 2007 were enrolled in this study and underwent magnetic resonance DTI-FT of the corticospinal tracts. Two regions of interest (ROI) were applied and the termination criteria were fractional anisotropy ${\geq}0.3$, angle ${\leq}70^{\circ}$. Results : The patterns and distribution of abnormal DTI-based corticospinal tractographic findings were interruption(10 cases, 76.9%), reduction of fiber volume (8 cases, 61.5%), agenesis of corticospinal tract (3 cases, 23.1%), transcallosal fiber (2 cases, 15.4%) and, aberrant corticospinal tracts (4 cases, 30.8%). Abnormal DTI-based corticospinal tractographic findings were in accordance with the clinical findings of cerebral palsy in 84.6% of the enrolled patients. Conclusion : Our results suggest that DTI-FT would be a use ful modality in the assessment of the corticospinal tract abnormalities in children with hemiplegic cerebral palsy.

Evaluation of Fibrosis in Liver Cirrhosis by Superparamagnetic Iron Oxide (SPIO)-Enhanced MR Imaging: Does the Radiological Non-Invasive Fibrosis Index Correlate with the Laboratory Non-Invasive Fibrosis Index? (Superparamagnetic Iron Oxide-Enhanced MRI를 이용한 간섬유화의 평가: 영상의학적 비침습적 간섬유화 지표가 AST/혈소판 비와 상관 관계가 있는가?)

  • Kim, Shin-Kee;Lee, Chang-Hee;Kim, Kyeong-Ah;Choi, Jae-Woong;Lee, Jong-Mee;Park, Cheol-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.115-122
    • /
    • 2008
  • Purpose : To evaluate the correlation between the radiological non-invasive hepatic fibrosis index (RNHFI), as determined by SPIO-enhanced MRI, and the laboratory non-invasive hepatic fibrosis index. Materials and Methods : Patients (99 total: 61 men and 38 women; mean age: 58 years) who underwent SPIO-enhanced MRI (1.5T) during 5 years included. These patients were subdivided into a liver cirrhosis group (LCG) and a non-liver cirrhosis group (non-LCG). Using PACS view, we measured the RNHFI (mean standard deviation of hepatic signal intensity (SD), noise-corrected coefficient of variation (CV)) of three ROIs in the liver parenchyma by SPIO-enhanced MRI. The laboratory non-invasive hepatic fibrosis index (AST-platelet ratio index (APRI)) of all patients was calculated from the laboratory data. We compared the RNHFI and APRI of LCG with those of non-LC group using Student's t-test. A bivariate correlation was performed to investigate the relationship between the RNHFI and APRI in the LCG. Results : For the LCG, mean values of SD and CV by SPIO-enhanced MRI were $10.3{\pm}3.7$ and $0.19{\pm}0.08$, respectively. For the non-LCG, mean values of SD and CV were $6.5{\pm}1.6$ and $0.08{\pm}0.05$, respectively. The mean APRI of the LCG and the non- LCG were $2.04{\pm}1.7$ and $0.32{\pm}0.32$, respectively. The RNHFI and APRI were significantly different between both groups (p<0.05). For the LCG, the bivariate correlation between SD and APRI revealed a statistically significant positive correlation (r=0.5, p<0.001). In both groups, there was no statistically significant correlation between CV and APRI. Conclusion: A measurement of SD can be a simple and useful method for the evaluation of hepatic fibrosis.

  • PDF

Diagnostic Accuracy of PET and MR for Detecting Liver Metastasis from Colorectal Cancer (대장-직장암의 간전이에서 FDG PET과 MR의 진단 성능)

  • Park, Eun-Kyung;Kang, Won-Jun;Eo, Jae-Seon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.249-256
    • /
    • 2006
  • Purpose: Although computed tomography (CT) is widely used for diagnosing liver metastasis from colorectal cancer, diagnostic accuracy of CT is not satisfactory. Magnetic resonance (MR) imaging and F-18 FDG PET has been reported to be superior to CT. However, studies on direct comparison of PET and MR are scarce. We compared the diagnostic accuracy of FDG PET and MR in detecting liver metastasis from colorectal cancer. Materials and Methods: Among 363 colorectal cancer patients who underwent F-18 FDG PET (ECAT, Siemens-CTI, Knoxville; Gemini, Philips, Milpitas, U.S.), 26 patients (M:F=17:9, age=$62{\pm}11$) underwent MR to evaluate suspicious metastatic liver lesions. Finally, 35 liver lesions detected by CT from 26 patients were enrolled for analysis. PET and MR results were compared with pathologic reports, clinical findings or follow-up results. Results: Of the 35 lesions, 18 lesions (51.4%) were diagnosed as liver metastases, while remaining 17 (48.6%) as benign. The sensitivity and the specificity of PET were 94.4% and 94.1%, respectively, compared to 100% and 82.4% for MR. MR and PET was concordant in 30 lesions (85.7%: 17 metastatic (94.4%) and 13 benign (76.5%) lesions. ROC curve analysis revealed maximal SUV of 3.1 as the optimum standard in differentiating metastatic from benign liver lesions (AUC=0.897, p<0.001, sensitivity 83.3%, specificity 94.1%). For small lesions less than 1 cm ln diameter (n=20), diagnostic accuracy of PET was comparable to that of MR. Conclusion: F-18 FDG PET showed good diagnostic performance in detecting liver metastasis from colorectal cancer, which was comparable to MR.

The Results of Arthroscopic Double-Row Rotator Cuff Repairs with Combined Knot-tying and Knotless Suture Anchors (매듭 결속과 비매듭 봉합나사를 이용한 관절경적 이열 회전근개 봉합술의 결과)

  • Ku, Jung-Hoei;Lee, Choon-Key;Cho, Hyung-Lae;Choi, Seung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.172-179
    • /
    • 2008
  • Purpose: To evaluate the functional and structural results of arthroscopic double-row repair using combined knot-tying and knotless suture anchors in rotator cuff tears. Materials and Methods: From March 2006 to June 2007, twenty-one patients (15 males, 6 females; mean age 55.6 years; range 48 to 67) were included who underwent arthroscopic double-row repair for full-thickness tears of the rotator cuff following conservative treatment for a mean of 6.5 months (range 3 to 11). The tear size was carefully inspected arthroscopically and we found 2 small, 13 medium and 6 large-sized rotator cuff tears, with a mean tear size of 2.5cm(range 1.8 to 3.2). The repair constructs were consisted of horizontal mattress sutures using conventional knot-tying suture anchors medially and simple suture at the same level of medial row stitch with Bioknotless RC anchors (DePuy Mitek, Norwood, MA) as lateral row. Clinical and functional evaluations were made according to the range of motion, the ASES, UCLA scale and the isokinetic strength testing. Postoperative cuff integrity was determined through magnetic resonance imaging. The mean follow-up was 15 months (range 13 to 24). Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up (p < 0.01). Nineteen patients (90%) were satisfied with the result of the treatment. In 17 of 21 patients (81%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 7 months postoperatively. There were no significant functional differences according to the preoperative tear size (p<0.01), but large-sized tear shows less favorable structural results in 3 out of 6 cases(50%). Conclusion: Our results document the usefulness and variability of arthroscopic double-row rotator cuff repairs comparable to the results of the other types of double-row repairs.

  • PDF

Comparison of the Medication Effects between Milnacipran and Pregabalin in Fibromyalgia Syndrome Using a Functional MRI: a Follow-up Study (섬유근통 환자에 대한 Milnacipran과 Pregabalin 약물치료에 대한 기능적 자기공명영상에서의 후속 영향 비교)

  • Kang, Min Jae;Mun, Chi-Woong;Lee, Young Ho;Kim, Seong-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.341-351
    • /
    • 2014
  • Purpose : In this study, the medication effects of Milnacipran and Pregabalin, as well known as fibromyalgia treatment medicine, in fibromyalgia syndrome patients were compared through the change of BOLD signal in pain related functional MRI. Materials and Methods: Twenty fibromyalgia syndrome patients were enrolled in this study and they were separated into two groups according to the treatment medicine: 10 Milnacipran (MLN) treatment group and 7 Pregabalin (PGB) treatment group. For accurate diagnosis, all patients underwent several clinical tests. Pre-treated and post-treated fMRI image with block-designed pressure-pain stimulation for each group were obtained to conduct the statistical analysis of paired t-test and two sample t-test. All statistical significant level was less than 0.05. Results: In clinical tests, the clinical scores of the two groups were not significantly different at pre-treatment stage. But, PGB treatment group had lower Widespread Pain Index (WPI) and Brief Fatigue Inventory (BFI) score than those of MLN treatment group at post-treatment stage. In functional image analysis, BOLD signal of PGB treatment group was higher BOLD signal at several regions including anterior cingulate and insula than MLN treatment group at post-treatment stage. Also, paired t-test values of the BOLD signal in MLN group decreased in several regions including insula and thalamus as known as 'pain network'. In contrast, size and number of regions in which the BOLD signal decreased in PGB treatment group were smaller than those of MLN treatment group. Conclusion: This study showed that MLN group and PGB group have different medication effects. It is not surprising that MLN and PGB have not the same therapeutic effects since these two drugs have different medicinal mechanisms such as antidepressants and anti-seizure medication, respectively, and different detailed target of fibromyalgia syndrome treatment. Therefore, it is difficult to say which medicine will work better in this study.

Evaluation of Renal Oxygenation in Normal Korean Volunteers Using 3.0 T Blood Oxygen Level-Dependent MRI (3.0 T 혈중산소치의존 자기공명영상을 이용한 정상한국인에서의 신장 산소공급의 평가)

  • Hwang, Sung Il;Lee, Hak Jong;Chin, Ho Jun;Chae, Dong-Wan;Na, Ki Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.1
    • /
    • pp.19-25
    • /
    • 2013
  • Purpose : Renal blood oxygen level-dependent (BOLD) MRI has been used in the evaluation of renal oxygenation. We tried to provide the normal $R2^*$ value of the human kidney with 3.0 T, and evaluated the differences in $R2^*$ values according to gender and location. Materials and Methods: Twenty-four healthy volunteers underwent BOLD MRI at 3.0 T. Multi gradient echo-echo planar imaging sequence with seventeen echoes was used. After generation of the $T2^*$ map, the $R2^*$ was calculated. The statistical differences in $R2^*$ values between the cortex and medulla, males and females, and the right and left kidney were analyzed. The regional differences of $R2^*$ within the both kidneys were evaluated respectively. Results: BOLD MRI was successful in all participants. No gross artifact interfered with $R2^*$ measurement. The mean $R2^*$ at 3.0 T was $17.1{\pm}2.60s^{-1}$ in the cortex and $27.7{\pm}4.83s^{-1}$ in the medulla (p < 0.001). The $R2^*$ value in the medulla was significantly higher in the male than female volunteers (p = 0.025). There were no statistical differences of $R2^*$ according to the side and location in the kidney (p = 0.197). Conclusion: Renal BOLD MRI can be efficiently performed with 3.0 T MRI. Renal medullary hypoxia is present in normal volunteers. Our results may be used as reference values in the evaluation of pathologic conditions using BOLD MRI.