• 제목/요약/키워드: Magnetic Resonance Image

검색결과 938건 처리시간 0.023초

3.0T 자기공명영상을 이용한 해상력 특성에 대한 연구 (Study on the Resolution Characteristics by Using Magnetic Resonance Imaging 3.0T)

  • 민정환;정회원;한지현;이시내;한송이;김기원;김현수;손진현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권4호
    • /
    • pp.251-257
    • /
    • 2020
  • This study was purpose to quantitative evaluation of edge method of modulation transfer function(MTF) and physical image characteristics of by obtain the optimal edge image by using magnetic resonance imaging(MRI). The MRI equipment was used (MAGNETOM Vida 3.0T MRI, Siemense healthcare system, Germany) and the head/neck matrix shim MR coil were 20 channels(elements) receive coil. The MTF results of showed the best value of 0.294 based on the T2 Nyquist frequency of 1.0 mm-1. The MTF results of showed that the T1 image is 0.160, the T1 CE image is 0.250, T1 Conca2 image is 0.043, and the T1 CE (Concatenation) Conca2 image is 0.190. The T2 image highest quantitatively value for MTF. The physical image characteristics of this study were to that can be used efficiently of the MRI and to present the quantitative evaluation method and physical image characteristics of 3.0T MRI.

정위방사선수술시 영상공동등록을 이용한 자기공명영상 유용성 평가 (Evaluation of Magnetic Resonance Imaging using Image Co-registration in Stereotactic Radiosurgery)

  • 진성진;조지환;박철우
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.235-240
    • /
    • 2017
  • 본 연구는 방사선수술 치료계획 시 영상공동등록을 이용한 자기공명영상의 3차원적 위치에 대하여 구조평가 및 뇌 정위 수술의 해부학적 기준점으로 사용되어지는 전교련(anterior commissure: AC)과 후교련(posterior commissure: PC)의 일치성을 평가하여 방사선수술시 영상공동등록의 임상 적용 안전성을 확인하고자한다. 정위 방사선수술 시행 후 2016년 3월~2017년 3월까지 영상공동등록을 이용한 자기공명영상 추적검사를 시행한 32명의 영상을 이용하여 3차원 좌표 측정을 통한 후향적 연구를 시행하였다. 전교련의 3차원 좌표 오차는 $1.0443{\pm}0.5724mm$(0.10 ~ 1.89), 후교련 3차원 좌표 오차는 $1.0348{\pm}0.5473mm$ (0.36 ~ 2.24)로 약 1 mm의 오차를 나타내었다. 자기공명영상 장비별 전교련과 후교련 좌표의 평균오차는 MR1(3.0 T)의 오차 값이 MR2 (1.5 T)에 비하여 낮게 나타났다. 영상공동등록 기법을 이용한 치료계획 시 자기공명영상의 오차를 최소화하여야 하며, 정확도를 확인하는 과정이 필요한 것으로 생각된다.

Magnetic Resonance Imaging (MRI) of a Hypertrophy of Cartilage and Simultaneous Regeneration of a Damaged Meniscus after Autologous Bone Marrow Aspirates Concentrate (BMAC) Transplantation: a Case Report and Literature Review

  • Bae, Sung Hwan;Kim, Hyun-joo;Oh, Eunsun;Hwang, Jiyoung;Hong, Seong Sook;Hwang, Jung Hwa
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권3호
    • /
    • pp.187-191
    • /
    • 2017
  • Bone marrow aspirates concentrate (BMAC) transplantation is a well-known technique for cartilage regeneration with good clinical outcomes for symptoms in patients with osteoarthritis (OA). Magnetic resonance imaging (MRI) has an important role in evaluating the degree of cartilage repair in cartilage regeneration therapy instead of a second assessment via an arthroscopy. We experienced a case of hypertrophic regeneration of the cartilage and a presumed simultaneous regeneration of the posterior horn of the lateral meniscus after BMAC transplantation for a cartilage defect at the lateral tibial and femoral condyle. This report provides the details of a case of an unusual treatment response after a BMAC transplant. This report is the first of its kind to demonstrate a MR image that displays the simultaneous regeneration of the cartilage and meniscus with a differentiation ability of the mesenchymal stem cell to the desired cell lineage.

Magnetic Resonance Imaging Diagnosis of Epidural Idiopathic Sterile Pyogranulomatous Inflammation in a Dog

  • Hwang, Taesung;Shin, Changho;Kim, Youngki;Yeon, Seongchan;Lee, Hee-chun
    • 한국임상수의학회지
    • /
    • 제34권5호
    • /
    • pp.377-380
    • /
    • 2017
  • An 8-year-old, shih-tzu female dog was referred due to neurological signs including paraparesis and back pain. On the complete blood count, hematologic analysis showed elevated leukocytosis. Serum biochemical analysis revealed elevated serum alkaline phosphatase concentration and C-reactive protein concentration. On the neurologic exam, the dog was suspected to have thoracolumbar myelopathy. On magnetic resonance imaging, there were masses within the spinal canal at L1-3 intervertebral disc space that were located dorsal to spinal cord. It was hyperintense on T1-, T2-weighted magnetic resonance images, Fluid-attenuated inversion recovery, and fat suppression images. The contrast-enhanced T1-weighted images showed no enhancement. The lesions were well circumscribed. The spinal cord was compressed and displaced ventrally by the mass. After removal of the masses via L1-L3 dorsal laminectomy, pyogranulomatous inflammation was confirmed by histopathological examination. Six months after surgery, the dog recovered uneventfully and remained fully ambulatory with no neurological deficits. This case demonstrates the utility of magnetic resonance imaging for the diagnosis of spinal canal pyogranulomatous inflammation.

Guidelines for Cardiovascular Magnetic Resonance Imaging from the Korean Society of Cardiovascular Imaging (KOSCI) - Part 3: Perfusion, Delayed Enhancement, and T1- and T2 Mapping

  • Im, Dong Jin;Hong, Su Jin;Park, Eun-Ah;Kim, Eun Young;Jo, Yeseul;Kim, Jeong Jae;Park, Chul Hwan;Yong, Hwan Seok;Lee, Jae Wook;Hur, Jee Hye;Yang, Dong Hyun;Lee, Bae-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권1호
    • /
    • pp.1-20
    • /
    • 2020
  • This document is the third part of the guidelines for the interpretation and post-processing of cardiac magnetic resonance (CMR) studies. These consensus recommendations have been developed by a Consensus Committee of the Korean Society of Cardiovascular Imaging (KOSCI) to standardize the requirements for image interpretation and post-processing of CMR. This third part of the recommendations describes tissue characterization modules, including perfusion, late gadolinium enhancement, and T1- and T2 mapping. Additionally, this document provides guidance for visual and quantitative assessment, consisting of "What-to-See," "How-To," and common pitfalls for the analysis of each module. The Consensus Committee hopes that this document will contribute to the standardization of image interpretation and post-processing of CMR studies.

Effect of Number of Measurement Points on Accuracy of Muscle T2 Calculations

  • Tawara, Noriyuki;Nishiyama, Atsushi
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.207-214
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the effect of the number of measurement points on the calculation of transverse relaxation time (T2) with a focus on muscle T2. Materials and Methods: This study assumed that muscle T2 was comprised of a single component. Two phantom types were measured, 1 each for long ("phantom") and short T2 ("polyvinyl alcohol gel"). Right calf muscle T2 measurements were conducted in 9 healthy male volunteers using multiple-spin-echo magnetic resonance imaging. For phantoms and muscle (medial gastrocnemius), 5 regions of interests were selected. All region of interest values were expressed as the mean ${\pm}$ standard deviation. The T2 effective signal-ratio characteristics were used as an index to evaluate the magnetic resonance image quality for the calculation of T2 from T2-weighted images. The T2 accuracy was evaluated to determine the T2 reproducibility and the goodness-of-fit from the probability Q. Results: For the phantom and polyvinyl alcohol gel, the standard deviation of the magnetic resonance image signal at each echo time was narrow and mono-exponential, which caused large variations in the muscle T2 decay curves. The T2 effective signal-ratio change varied with T2, with the greatest decreases apparent for a short T2. There were no significant differences in T2 reproducibility when > 3 measurement points were used. There were no significant differences in goodness-of-fit when > 6 measurement points were used. Although the measurement point evaluations were stable when > 3 measurement points were used, calculation of T2 using 4 measurement points had the highest accuracy according to the goodness-of-fit. Even if the number of measurement points was increased, there was little improvement in the probability Q. Conclusion: Four measurement points gave excellent reproducibility and goodness-of-fit when muscle T2 was considered mono-exponential.

Guidelines for Cardiovascular Magnetic Resonance Imaging from the Korean Society of Cardiovascular Imaging (KOSCI) - Part 2: Interpretation of Cine, Flow, and Angiography Data

  • Lee, Jae Wook;Hur, Jee Hye;Yang, Dong Hyun;Lee, Bae Young;Im, Dong Jin;Hong, Su Jin;Kim, Eun Young;Park, Eun-Ah;Jo, Yeseul;Kim, Jeong Jae;Park, Chul Hwan;Yong, Hwan Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권4호
    • /
    • pp.316-327
    • /
    • 2019
  • Cardiovascular magnetic resonance imaging (CMR) is expected to be increasingly used in Korea due to technology advances and the expanded national insurance coverage of these tests. For improved patient care, it is crucial not only that CMR images are properly acquired but that they are accurately interpreted by well-trained personnel. In response to the increased demand for CMR, the Korean Society of Cardiovascular Imaging (KOSCI) has issued interpretation guidelines in conjunction with the Korean Society of Radiology (KSR). KOSCI has also created a formal Committee on CMR Guidelines to write updated practices. The members of this Committee review previously published interpretation guidelines and discuss the patterns of CMR use in Korea.

MR 영상에서 확산현상에 의한 경계강조 (Edge Enhancement due to Diffusion Effect in Magnetic Resonance Imaging)

  • 홍인기;노용만;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.124-127
    • /
    • 1995
  • Due to the self-diffusion of nuclear spins, the edge of phantoms is enhanced in the magnetic resonance imaging (MRI), especially in the case of microscopy [1]. According to several published works, theory has been established that the edge enhancement is caused by the motion narrowing around bounded regions due to diffusions of nuclear spins during data acquisition. It is found, however, that the signal decreases due to the diffusion attenuation and image is distorted as edge of the image is sharpened. In this paper, we wilt investigate this signal loss during data acquisition and its effects on image, i.e., image edge enhancement due to the diffusion phenomenon. This result is new and different from the previously discussed edge enhancement due to the diffusion, namely, by motion narrowing effect or spin bouncing effect at the boundary.

  • PDF

자기공명영상장치(磁氣共鳴映像裝置)에서 움직임허상(虛像)의 위치제어(位置制御)에 관(關)한 연구(硏究) (A Study on Locational Control of Motion Ghost in Magnetic Imaging System)

  • 이후민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권2호
    • /
    • pp.19-26
    • /
    • 1993
  • Magnetic Resonance Image represents three-dimensional diagnostic imaging technique using both nuclear magnetic resonance phenomenon and computer. Compared with computed tomography (CT), MRI have advantages harmless to patient's body, three-dimensional image with high resolution and disadvantages long data acquisition time because of long T1 relaxation time, relatively low signal to noise ratio, high cost of setting, also. As physiologic motion of tissue results in motion ghost in MRI, high 2.0Tesla make improve low signal to noise ratio. This study have aim to improve image quality with controling motion ghost of tissue. Supposing a moving pixel in constant frequency, one pixel make two ghosts which are same size and different anti-phase. So, this study will show adjust parameter on locational control of motion ghost. Author made moving phantom replaced by respiratory movement of human, researched change of motion frequency, FOV by location shift, and them decided optimal FOV (field of view). The results are as follows: 1. The frequency content of the motion determines how far the image always appear in phase-encoding direction, the morphology of the ghost image is characteristic of the direction of the motion and its amplitude. 2. Double FOV of fixed signal object for locational control of motion ghost is recommended. Decreasement of spatial resolution by increasing FOV can compensate on increasing of matrix in spite of scan time increasement.

  • PDF

치과 교정 물질에 따른 자기공명영상의 왜곡 (Distortion of Magnetic Resonance Imaging for Different Types of Orthodontic Material)

  • 송현옥;임청환;이상호;양오남;백창무;정홍량
    • 디지털융복합연구
    • /
    • 제12권2호
    • /
    • pp.439-446
    • /
    • 2014
  • 자기공명영상검사에서 치과 교정용 금속 물질에 의한 인공물(Artifact)의 영향을 평가하기 위해 치과 교정에 사용되는 와이어(Wire)와 브라켓(Bracket)을 재질별로 선택하여 비교 연구하였다. 치과 금속을 넣은 사각 아크릴 용기는 $200{\times}135{\times}120mm$ 크기이며, 영상을 얻기 위하여 두부 코일을 사용하여 $T_2$강조영상, $T_1$강조영상, FLAIR영상을 획득하였다. 획득된 시퀀스별 자기공명영상의 인공물을 평가하기 위하여 Image J 프로그램을 사용하여 인공물의 면적을 측정 비교하였다. 연구에서 치과 교정용 와이어와 브라켓의 인공물이 가장 큰 물질은 Stainless steel로 나타났다. 현재까지는 치과 교정에서 교정을 목적에 두고 금속 물질을 선택하였으나 치과 교정용 금속은 환자의 기능과 미의 특성뿐 아니라 자기공명영상 인공물 생성 여부도 함께 고려해야 한다. 추후 교정용 금속의 선택 및 개발 발전은 치아교정의 목적과 더불어 다른 분야도 고려해야 할 것으로 사료된다.