• 제목/요약/키워드: Magnetic Probe

검색결과 262건 처리시간 0.028초

A study on the effect of the condition number in the magnetic field mapping of the Air-Core solenoid

  • Huang, Li;Lee, Sangjin
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권2호
    • /
    • pp.31-35
    • /
    • 2015
  • Mapping is a useful tool in the magnetic field analysis and design. In some specific research area, such as the nuclear magnetic resonance (NMR) or the magnetic resonance imaging (MRI), it is important to map the magnetic field in the interesting space with high accuracy. In this paper, an indirect mapping method in the center volume of an air-core solenoid is presented, based on the solution of the Laplace's equation for the field. Through the mathematical analysis on the mapping calculation, we know that the condition number of the matrix, generated by the measurement points, can greatly affect the error of mapping result. Two different arrangement methods of the measurement points in field mapping are described in this paper: helical cylindrical line (HCL) method and parallel cylindrical line (PCL) method. According to the condition number, the HCL method is recommended to measure the field components using one probe. As a simple example, we mapped the magnetic fields in a MRI main magnet system. Comparing the results in the different methods, it is feasible and convenient to apply the condition number to reduce the error in the field mapping calculation. Finally, some guidelines were presented for the magnetic field mapping in the center volume of the air-core solenoid.

The magnetic properties in Bi$_2$Sr$_2$CaCu$_2$O$_8$ single crystal with columnar defects

  • Lee, C.W.;Shim, S.Y.;Ha, D.H.;Kim, D.H.;Lee, T.W.
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.103-106
    • /
    • 2000
  • We have studied the magnetic properties in Bi$_2$Sr$_2$CaCu$_2$O$_8$ single crystal with columnar defects using micro Hall-probe array. We found that fold profiles inside sample were similar to the Bean's critical state model from the magnetic hysteresis measurement. In the magnetic relaxation measurement, the normalized relaxation rates were maximum near the center and decreased toward the edge of the sample expect zero gauss. The relaxation rates as a function of the temperature were maximum near the 40K and rapidly decreased both sides of the peak.

  • PDF

ECR 플라즈마 장치의 제작 (Construction of an Electron Cyclotron Resonance Plasma Apparatus)

  • 오수기;정근모
    • 한국진공학회지
    • /
    • 제1권1호
    • /
    • pp.32-36
    • /
    • 1992
  • ECR 플라즈마 장치를 설계 제작하였다. ECR 플라즈마의 흐름을 얻기 위해 자기장 의 기울기를 조작할 수 있는 전자석계가 필요하였다. 요크를 사용하면 같은 전류로 자기장 을 1.5배 더 크게 할 수 있었다. 이 장치로 만든 ECR 플라즈마의 특성을 조사하기 위하여, 랑뮈르 탐침을 이용하여 챔버의 축방향을 따라 위치에 따른 전자온도 Te와 전자밀도 Ne의 공간분포를 실험적으로 구하였다.

  • PDF

플라즈마 파라메타와 자계의 상관관계에 관한 연구 (A study on the relationships between plasma parameters and magnetic field)

  • 김두환;장윤석;조정수;박정후
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.426-431
    • /
    • 1996
  • It is well known that the understanding of the complex mechanism of magnetoplasma is closely related with understanding of the collective behavior of discharge plasma parameters such as the cathode-sheath potential, cathode-sheath thickness, electron temperature, electron density, and ambipolar diffusion. In this paper, some of the relationships between these plasma parameters and magnetic field is investigated experimentally with a Langmuir probe in the magnetoplasma generated by D.C diode system. It is found that when magnetic field is increased, cathode-sheath potential, cathode-sheath thickness, and ambipolar diffusion are decreased. In addition, peak ion density obtained as a parameter of ionic signal voltage by Faraday cup method is independent of magnetic field. (author). 9 refs., 11 figs.,1 tab.

  • PDF

HR-MAS NMR Technique for Metabolic Profiling of Powdery Ginseng

  • Yoon, Dahye;Jo, Ick-Hyun;Kim, Suhkmann
    • 한국자기공명학회논문지
    • /
    • 제20권3호
    • /
    • pp.82-86
    • /
    • 2016
  • Ginseng is used as a medicinal ingredient. The quality control of species, age, origin and manufacturing process is important. The metabolome of ginseng about quality was studied in many reports. Almost studies carried out the extract of ginseng, however, the reproducibility cannot be obtained using extracted sample. In this study, powdery ginseng samples were analyzed using high resolution-magic angle spinning nuclear magnetic resonance (HR-MAS NMR)-based metabolomics except extraction step. Sample was measured three times using 600 MHz NMR spectrometer equipped with nano probe. Reproducibility can be enhanced using this method and the metabolic profiles of ginseng were identified and quantified.

대면적 스퍼터링 박막 제작을 위한 캐소드 설계 및 제작 (Design and Preparation of Cathode for Large Sputtering Thin Film)

  • 김유진;김상모;김경환
    • 반도체디스플레이기술학회지
    • /
    • 제18권2호
    • /
    • pp.53-57
    • /
    • 2019
  • In this study, we prepared sputtering cathode for large sputtering thin film in the facing targets sputtering(FTS) system. Before fabrication of cathode equipment, we investigated optimal magnetic flux in the sputtering cathode by using magnetic field stimulation(Comsol). According to the result of magnetic field stimulation, we manufactured the cathode. After we mounted laboratory-designed cathode on FTS system, the discharge properties were observed in vacuum condition. In addition, ITO films were deposited on glass substrate and their electrical and optical properties were investigated by various measurements (four-point probe, UV-VIS spectrometer, field emission scanning electron microscopy(FE-SEM), Hall-effect measurement).

Design of Shielded Encircling Send-Receive Type Pulsed Eddy Current Probe Using Numerical Analysis Method

  • Shin, Young-Kil
    • 비파괴검사학회지
    • /
    • 제33권6호
    • /
    • pp.505-510
    • /
    • 2013
  • An encircling send-receive type pulsed eddy current (PEC) probe is designed for use in aluminum tube inspection. When bare receive coils located away from the exciter were used, the peak time of the signal did not change although the distance from the exciter increased. This is because the magnetic flux from the exciter coil directly affects the receive coil signal. Therefore, in this work, both the exciter and the sensor coils were shielded in order to reduce the influence of direct flux from the exciter coil. Numerical simulation with the designed shielded encircling PEC probe showed the corresponding increase of the peak time as the sensor distance increased. Ferrite and carbon steel shields were compared and results of the ferrite shielding showed a slightly stronger peak value and a quicker peak time than those of the carbon steel shielding. Simulation results showed that the peak value increased as the defect size (such as depth and length) increased regardless of the sensor location. To decide a proper sensor location, the sensitivity of the peak value to defect size variation was investigated and found that the normalized peak value was more sensitive to defect size variation when the sensor was located closer to the exciter.

강자성 박판소재의 잔류응력 측정 시스템의 설계 및 제작 (System Design and H/W Development of the Residual Stress Measurement for Ferromagnetic thin Sheet)

  • 김상원;양충진
    • 한국자기학회지
    • /
    • 제11권2호
    • /
    • pp.50-57
    • /
    • 2001
  • 강자성 극박소재에 유기된 잔류응력을 검출하기 위하여 자기유도형 탐촉자(probe)를 설계·제작하였으며, 이를 장착한 잔류음력 평가시스템은 박판내에 유기된 잔류응력의 주응력 방향과 크기를 효과적으로 결정하여 준다. 이 시스템을 반도체 칩 팩키지(package)용으로 사용하는 Fe-42Ni계 lead frame 판재의 잔류응력 검출에 적용한 결과, 양호재 및 잔류응력과다 불량재에 대한 출력전압은 명확히 구별되었고, 잔류응력이 축적된 판재는 양호재와 비교하여 응력의 분포 및 크기에 있어 항상 차이를 나타내었다. 이러한 차이는 탐촉자에 투입하는 전류와 주파수의 함수로 잘 분해되어질 수 있음을 확인하였다.

  • PDF

위상차를 갖고 변화하는 자기장과 전류가 동시에 가해진 $Sm_1Ba_2Cu_3O_{7-\delta}$ Coated Conductor의 자기이력 손실 (Hysteresis Loss in a $Sm_1Ba_2Cu_3O_{7-\delta}$ Coated Conductor under Simultaneously Applied Field and Current with Phase Differences)

  • 이상무;정예현;곽기성;이준규;유재은;염도준;김호섭;하홍수;오상수
    • Progress in Superconductivity
    • /
    • 제10권2호
    • /
    • pp.92-98
    • /
    • 2009
  • The magnetic field profiles near the surface of a $Sm_1Ba_2Cu_3O_{7-\delta}$ coated conductor(CC-tape) under magnetic field and current that were applied simultaneously with phase differences ${\phi}s$ were measured using scanning Hall probe method. Measurements were carried out along the elliptic load lines with $\phi=90^{\circ}\;and\;45^{\circ}$ for some $B_{peak},\;I_{peak}$ values. From the measured field profiles, sheet current density J(x, $B_a,\;I_a$) and magnetic flux density $B_0(x,\;B_a,\;I_a)$ profiles in the CC-tape were calculated. Using these J(x, $B_a,\;I_a$) and $B_0(x,\;B_a,\;I_a)$ profiles, we estimated the hysteresis energy loss Q in the CC-tape. The estimated Qs, together with our previous results for $\phi=0^{\circ}$ from [9], were compared with theoretical values based on Brandt's calculation.

  • PDF

Probing galactic and intergalactic magnetic fields using Faraday tomography (optionally title in Korean in parentheses)

  • Ideguchi, Shinsuke;Takahashi, Keitaro;Akahori, Takuya;Ryu, Dongsu
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.31.1-31.1
    • /
    • 2015
  • For probing magnetic fields in the universe, rotation measure (RM) have been often used. RM allows us to obtain the information of integrated (or averaged) magnetic fields along a line of sight (LOS). On the other hand, the new technique so-called Faraday tomography will be used in practical in the near future thanks to the wide-band polarimetry by Square kilometre Array and/or its precursors. The technique allows us to obtain so-called Faraday dispersion function (FDF). FDF is the distribution function of magnetic fields and polarized sources along a LOS. Because of this fact, it is expected that the studies of magnetic fields associated with various astronomical objects will progress dramatically. Since FDF also includes information of cosmic-rays and thermal electrons, the investigation of FDF may advance the studies of dynamics of external galaxies and/or the star formation activities. We have studied the potentials of Faraday tomography such as a tool to probe the intergalactic magnetic field associated with filaments of galaxies in the large scale structure. We have also studied the realistic FDFs of galaxies for understanding global magnetic field, cosmic-ray and thermal electrons of external galaxies. In the talk, we briefly introduce the Faraday tomography technique and report the results related to the Faraday tomography.

  • PDF