• 제목/요약/키워드: Magnetic Probe

검색결과 262건 처리시간 0.027초

Solid-state NMR Studies of Membrane Proteins Using Phospholipid Bicelles

  • Kim, Yong-Ae
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권3호
    • /
    • pp.386-388
    • /
    • 2006
  • Membrane proteins in highly oriented lipid bilayer samples are useful for membrane protein structure determination. We used in the past planar lipid bilayers which were aligned and supported on the glass slide. These samples were mechanically aligned in a magnetic field. However, these stacks of glass slides with planar lipid bilayers are not well suited for use with a commercial solid-state NMR probe with a round coil. Therefore, a homebuilt solid-state NMR probe was built and used with a stack of thin glass plates wherein the RF coil was wrapped directly around the flat square sample. Recently, we began to use magnetically aligned bicelles that are suitable for the structure determination of membrane proteins by solid-state NMR spectroscopy without any effort to build a flat square coil probe. These bicelle samples are well suited for use with a commercial solidstate NMR probe with a round coil, are very easy to prepare and are very stable, so that they can be kept for more than a year. In this paper, we present the solid-state NMR spectra of optimized and magnetically oriented bicelle samples of membrane proteins.

Backbone assignment of HMGB1 A-box and molecular interaction with Hoxc9DBD studied by paramagnetic probe

  • Choi, Ji Woong;Park, Sung Jean
    • 한국자기공명학회논문지
    • /
    • 제25권2호
    • /
    • pp.17-23
    • /
    • 2021
  • High mobility group protein B1 (HMGB1) is a highly conserved, non-histone, chromatin associated nuclear protein encoded by HMGB1 gene. HMGB1 proteins may be general co-factors in Hox-mediated transcriptional activation that facilitate the access of Hox proteins to specific DNA targets. It is unclear that the exact binding interface of Hoxc9DBD and HMGB1. To identify the interface and binding affinity of Hoxc9DBD and HMGB1 A-box, the paramagnetic probe, MTSL was used in NMR titration experiment. It is attached to the N-terminal end of HMGB1 A-box by reaction with thiol groups. The backbone assignment of HMGB1 A-box was achieved with 3D NMR techinques. The 15N-labeled HMGB1 A-box was titrated with MTSL-labeled Hoxc9DBD respectively. Based on the chemical shift changes we can identify the interacting residues and further map out the binding sites on the protein structure. The NMR titration result showed that the binding interface of HMGB1 A-box is around loop-1 between helix-1 and helix-2. In addition, the additional contacts were found in N- and C-terminus. The N-terminal arm region of Hoxc9DBD is the major binding region and the loop between helix1 and helix2 is the minor binding region.

스캐닝 홀 프로브 측정 시스템의 데이터 측정 위치 표시 기술 (position marking technique for data measured in a scanning hall probe system)

  • 유재은;이재영;정예현;이상무;염도준
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.13-15
    • /
    • 2007
  • We employed home-made position marking module in the scanning Hall probe system. The module is composed of two coils of which gap, a, between wires in a coil is $500{\mu}m$. We appiled 10-35mA of current with 15Hz in the coils and recorded ac corresponding magnetic field signal with respect to measuring time while we measured DC field profiles produced due to superconducting film in a perpendicular magnetic field. We calibrate the position, x, of coils using the measuring time and location of the coils in the holder. The error range was about ${\pm}0.1mm$. We test the module as we applied current of 100A and filed of 1kG in the superconducting tape. It was confirmed that there was no interference between superconducting tape and marking coils.

Enhanced Inductively Coupled Plasma의 자화 주파수 의존 특성 (Magnetized Frequency characteristics of Enhanced Inductively Coupled Plasma)

  • 라상호;박세근;오범환
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(2)
    • /
    • pp.302-305
    • /
    • 2000
  • It is important to control the electron energy distribution to have high quality plasma process. A conventional inductively coupled plasma(ICP) source with 13.56MHz power is not adequate for low damage sub-half micron patterning process due to higher electron temperature. Only the pulsed plasma technique seems to provide low electron temperature, and thus low process damage. Recently, a novel method proposed by us, named as ‘Enhanced-ICP’, which uses periodic weak axial magnetic field added to a normal ICP source, has shown great improvement in etch characteristics. changes of plasma characteristics according to the frequency of time-varying axial magnetic field have been observed by probe-time-averaged Langmuir probe.

  • PDF

병렬 안테나에 따른 플라즈마원의 균일도 연구 (Study on the Uniformity of Plasma Density at TCP Using Parallel Antennas)

  • 배근희;서상훈;장홍영
    • 한국진공학회지
    • /
    • 제7권3호
    • /
    • pp.273-276
    • /
    • 1998
  • 안테나에 따른 플라즈마 밀도의 균일도 연구를 위해 병렬 안테나를 설계하고 이중 랑뮤어 탐침과 자기장 측정 탐침을 이용하여 각각의 플라즈마 밀도와 자기장의 세기를 측정 하였다. 나비형 안테나를 사용했을 때 플라즈마 밀도가 ~$2\times10^{11}(\textrmcm^{-3})$로 다른 두 안테나를 사용했을 때보다 높았으며, 전자의 온도는 2eV 이하로 동일한 조건에서의 나선형 안테나보 다 낮게 나왔다. 또 전류의 방향이 서로 다른 두 개의 안테나선이 가까이 있거나 안테나 성 분끼리 양성 결합(positive coupling)을 하는 경우에는 동력 효율(power efficiency)이 매우 낮아졌다.

  • PDF

Heliospheric Current Sheet Probe

  • Yu, Yi
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제23권1호
    • /
    • pp.12-17
    • /
    • 1995
  • Space explorations by spacecraft have detected the solar wind and the interplanetary magnetic field (IMF), whose existences had been suggested to explain the narrow comet plasma tail formation before the space age. Thereafter, a global magnetic structure seperating the opposite polarity regions of IMF in the heliosphere was discovered (Wilcox and Ness, 1965). It is called helispheric current sheet (HCS). Comets have been proved as the useful heliospheric probes. Recently, another capability of comet as a probe of HCS was suggested by Yi (1994). In the process of comet plasma tail disconnection events (EDs) showing the ray folding and main tail severance between the folding rays (Brandt, 1982), the folding rays preceding DE might be the visualization of HCS draped around comet, In order to test this new idea, the association of comet Halley 16 DEs with comet crossings of HCS confirmed by spacecraft observations at the time of comet Halley apparition 1985~1986 was investigated.

  • PDF

$^2D$ NMR Probe Development for Investigation of Biosupramolecular Systems

  • Kim, Andre;Kang, Shin-Won;Park, Jang-Su
    • 한국자기공명학회논문지
    • /
    • 제8권1호
    • /
    • pp.55-61
    • /
    • 2004
  • Biosupramolecular systems such as biological membranes usually fluid under physiological conditions$^1$. Therefore, solid-state NMR has been used to investigate biosupramolecular systems. But solid-state NMR spectra contain a large number of overlapping resonances and are rather difficult to analyze. These problem has to be overcome by selective isotope labeling. We constructed a deuterium NMR probe for AM400 NMR spectrometer, which is mainly used for liquid samples. To overcome the fluidity problem, a saddle type coil was designed. The efficiency was systematically investigated for two kinds of coil geometry, solenoid and saddle types. Our results suggest that solenoids are superior to saddle type coils in the sensitivity. However, the letter fits better to fluid samples such as biosupramolecular systems.

  • PDF

직류철도차량에 대한 자계측정 및 분석 (Measurement and Analysis of Electromagnetic field for DC electric railway train)

  • 장동욱;김민철;이장무;한문섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1637-1639
    • /
    • 2005
  • The measurement of magnetic field is performed about DC and AC magnetic field in test track of depot. The test point is cap, on the converter/inverter box, on the traction motor, on the APSE and on the line filter, the height of measurement is bottom and 50 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through RS-232C and notebook PC. The DC magnetic field is measured by using the Hall Probe, test result is saved and analysis by PXI system. On the line filter, the maximum value is 1.4 mT in case of DC magnetic field and 0.044 mT in case of AC magnetic field at 50 Hz.

  • PDF