• 제목/요약/키워드: Magnetic Probe

검색결과 262건 처리시간 0.023초

가스터빈 로터 재질에 따른 표면결함 와전류 특성연구 (The Study on Eddy Current Characteristic for Surface Defect of Gas Turbine Rotor Material)

  • 안연식;길두송;박상기
    • 동력기계공학회지
    • /
    • 제14권4호
    • /
    • pp.63-67
    • /
    • 2010
  • This paper introduces the eddy current signal characteristic of magnetic and non-magnetic gas turbine rotor. In the past, Magnetic particle inspection method was used in magnetic material for qualitative defect evaluation and the ultrasonic test method was used for quantitative evaluation. Nowadays, eddy current method is used in magnetic gas turbine rotor inspection due to advanced sensor design technology. We are studying on the magnetic gas turbine rotor by using eddy current method. We prepared diverse depth specimens made by magnetic and non-magnetic materials. We select optimum frequency according to material standard penetration data and experiment results. We got the signal on magnetic and non-magnetic material about 0.2 mm, 05 mm, 1.0 mm, 1.5 mm 2.0 mm and 2.5 mm depth defects and compare the signal amplitude and signal trend according to defect depth and frequency. The results show that signal amplitudes of magnetic are bigger than non-magnetic material and the trends are similar on every defect depth and frequency. The detection and resolution capabilities of eddy current are more effective in magnetic material than in non-magnetic materials. So, the eddy current method is effective inspection method on magnetic gas turbine rotor. And it has the merits of time saving and simple procedure by elimination of the ultrasonic inspection in traditional inspection method.

핵자기공명 영상법을 위한 내부 영상용 뒤집음-탐침의 제작 (Construction of Magnetic Resonance Imaging Inside-out probes for Internal Imaging)

  • 고락길;이동훈;정은기
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.78-81
    • /
    • 1995
  • In imaging the samples or human internal organs in a tube shape, general RF-probe types (that encircles a sample or places on top of the sample) are usually unsuitable for the internal imaging due to the degradation of signal-to-noise ratios(SNR's). In the present study the inside-out probes for Magnetic Resonance Imaging (MRI) have been constructed in the three different shapes such as an anti-solenoidal, a saddle and a dual surface types which are positioned as close to the area as possible by putting the probe inside the tubelike sample to improve filling factor. RF-field distributions have also been calculated depending upon the geometrical changes of anti-solenoid probes. Moreover, the performance of the inside-out probes has been checked by measuring SNR's of the images acquired. The inside-out probes constructed in this study produced better SNR's and rf-field uniformity in the area close to the probes in comparing with any other commercial probes. There is a high possibility that the constructed probes in the present study are applicable to the diagnosis of human bodies.

  • PDF

방사광 가속기용 2극 전자석 특성측정 및 보정 (Magnetic Measurement of PLS Storage Ring Prototype Dipole Magnet)

  • 강봉구;박기현;윤종렬;구양모
    • 한국자기학회지
    • /
    • 제2권2호
    • /
    • pp.163-168
    • /
    • 1992
  • 포항 방사광 가속기 저장링용 시제품 2극전자석의 특성측정 및 보정결과에 대하여 기술 하였다. 전자석의 저장특성 측정을 위해 Hall probe mapping 기법과 rotating coil 기법과 rotating coil 기법을 동시에 사용하였다. 자장측정 결과로부터 2극전자석의 요구조건을 만족하도록 자극의 양 쪽 끝 부분을 수정하였다. 보정이 끝난 전자석은 2.0 GeV의 beam energy로 동작시킬 경우(1.058 Tesla) 약 99.7%의 효율을 얻었으며, 4극 이상의 다극 오차성분도 허용오차 범위 미만으로 포항 방사광 가속 기 저장링용 2극 전자석으로 적합함이 판명 되었다.

  • PDF

아몰퍼스 와이어의 ECT probe 적용에 대한 검토 (Application of Amorphous wire to ECT(Eddy Current Testing) Probe)

  • 김영학;신광호;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.47-51
    • /
    • 2002
  • ECT(eddy currentign testing) is very effective technique to detect a flaw within a conductor. Co-based amorphous wire was used as a sensor head. The wire has almost 0 magneto-striction and high permeability. An uniform magnetic field was applied to 1mm thick copper plate and $25{\mu}m$ thick aluminum sheet conductor using spiral typed coil The size of the coil has $40mm{\times}40mm$ outer width and $8mm{\times}8mm$ inner width. The copper plate and aluminum sheet has 0.5mm and 0.1mm wide gap, respectively. The frequency range of applied field was 100kHz-600kHz. The induced voltage difference of 2.5mV was obtained in the maximum voltage and minimum one measured across the gap of the 1mm thick conductor. In the case of aluminum sheet, 0.4mV was obtained. From this results, the effectiveness of Co-based amorphous wire was confirmed in the ECT technique.

  • PDF

Hyperpolarized Carbon-13 Magnetic Resonance Imaging: Technical Considerations and Clinical Applications

  • Ying-Chieh Lai;Ching-Yi Hsieh;Yu-Hsiang Juan;Kuan-Ying Lu;Hsien-Ju Lee;Shu-Hang Ng;Yung-Liang Wan;Gigin Lin
    • Korean Journal of Radiology
    • /
    • 제25권5호
    • /
    • pp.459-472
    • /
    • 2024
  • Hyperpolarized (HP) carbon-13 (13C) MRI represents an innovative approach for noninvasive, real-time assessment of dynamic metabolic flux, with potential integration into routine clinical MRI. The use of [1-13C]pyruvate as a probe and its conversion to [1-13C]lactate constitute an extensively explored metabolic pathway. This review comprehensively outlines the establishment of HP 13C-MRI, covering multidisciplinary team collaboration, hardware prerequisites, probe preparation, hyperpolarization techniques, imaging acquisition, and data analysis. This article discusses the clinical applications of HP 13C-MRI across various anatomical domains, including the brain, heart, skeletal muscle, breast, liver, kidney, pancreas, and prostate. Each section highlights the specific applications and findings pertinent to these regions, emphasizing the potential versatility of HP 13C-MRI in diverse clinical contexts. This review serves as a comprehensive update, bridging technical aspects with clinical applications and offering insights into the ongoing advancements in HP 13C-MRI.

어레이 IrMn 스핀밸브 소자의 자기저항특성 연구 (Magnetoresistive Properties of Array IrMn Spin Valves Devices)

  • 안명천;최상대;주호완;김기왕;황도근;이장로;이상석
    • 한국자기학회지
    • /
    • 제17권4호
    • /
    • pp.156-161
    • /
    • 2007
  • 어레이(away) 자성센서 개발을 위해 고진공 스퍼터링 증착장비를 이용하여 스펙큘러형(specular type) Glass/Ta(5)/NiFe(7)/IrMn(10)/NiFe(5)/$O_2$/CoFe(5)/Cu(2.6)/CoFe(5)/$O_2$/NiFe(7)/Ta(5)(nm) 거대자기저항-스핀밸브(giant magnetoresistive-spin valves; CMR-SV)박막을 제작하였다. 다층박막 시료를 $20{\times}80{\mu}m^2$의 미세 활성영역을 가진 15개 어레이를 $8{\times}8mm^2$ 영역 내에 최적화한 제작 조건으로 광 리소그래피 패터닝 하였다. Cu를 증착하여 만든 2단자 전극법으로 측정한 자성특성은 15개 모든 소자들이 균일한 자기저항특성을 나타내었고, 5 Oe 근방에서 가장 민감한 자기저항비 자장민감도와 출력전압들은 각각 0.5%/Oe, ${\triangle}$V: 3.9 mV이었다. 형상자기이방성이 적용된 상부 자유층 $CoFe/O_2/NiFe$층은 하부 고정 자성층 $IrMn/NiFe/O_2/CoFe$층 자화 용이축과 직교하였다. 측정시 인가전류 값을 각각 1 mA에서 10 mA까지 인가하였을 때 출력 작동 전압 값은 균일하게 증가하였으며, 자장감응도도 거의 일정하여 미세 외부자장에 민감한 나노자성소자로서 좋은 특성을 띠었다.

Helicon Discharge Plasma Source and Laser Thomson Scattering System in KRISS

  • 서병훈;유신재;김정형;성대진;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.149-149
    • /
    • 2012
  • We introduce Helicon discharge plasma source and Laser Thomson scattering system recently finished an installation in KRISS. Laser Thomson scattering method is promising for diagnostics in Helicon plasma because a measurement by electrical probe typically used has significant errors due to the gyromotion of electrons induced by high magnetic field. However, we found that LTS is affected by magnetic field so that we applied the normalization method for processing data and the results show a clear Maxwellian distribution at various conditions of magnetic field and RF power at low energy part without distortion.

  • PDF