• Title/Summary/Keyword: Magnetic Modulation

Search Result 150, Processing Time 0.02 seconds

Development of Irreversible Micro-size Ferromagnetic Structures by Hydrogenation and Electron-beam Lithography (수소화 및 전자빔 사진식각 기술에 의한 비가역적 마이크로 크기의 강자성 구조체 개발)

  • Yun Eui-Jung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.1 s.343
    • /
    • pp.7-12
    • /
    • 2006
  • In this study, we developed irreversible and stable micro-size ferromagnetic structures utilizing hydrogenation and electron-beam lithography processes. The compositionally modulated (CM) Fe-Zr thin films that had average compositions $Fe_XZr_{100-x}$ with $x=65-85\%$ modulation periods of similar to 1 nm, and total thicknesses of similar to 100 m were prepared. The magnetic properties of CM Fe-Zr thin films were measured using a SQUID magnetometer, VSM and B-H loop tracer. After hydrogenation, the CM films exhibited larger magnetic moment increases than similar homogeneous alloy films for all compositions and かey showed largest increase in $Fe_{80}Zr_{20}$ composition. After aging in air at $300^{\circ}K$ the hydrogenated $Fe_{80}Zr_{20}$ CM films showed much larger magnetic moment increases, indicating that they relax to a stable, irreversible, soft magnetic state. The selective hydrogenation through electron-beam lithographed windows were performed after the circle shaped windows were prepared on $Fe_{80}Zr_{20}$ CM films by electron beam lithography. The hydrogenation through electron-beam resist and W lithographic techniques give a $49\%$ magnetic moment increase. This method can be applied to nano scale structures.

Pharmacological Functional Magnetic Resonance Imaging of Cloropidol on Motor Task (운동과제에 대한 클로피도그렐의 약리적 뇌자기공명영상)

  • Chang, Yong-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.136-141
    • /
    • 2012
  • Purpose : To investigate the pharmacologic modulation of motor task-dependent physiologic responses by antiplatelet agent, clopidogrel, during hand motor tasks in healthy subjects. Materials and Methods: Ten healthy, right-handed subjects underwent three functional magnetic resonance (fMRI) sessions: one before drug administration, one after high dose drug administration and one after reaching drug steady state. For the motor task fMRI, finger flexion-extension movements were performed. Blood oxygenation level dependent (BOLD) contrast was collected for each subject using a 3.0 T VHi (GE Healthcare, Milwaukee, USA) scanner. $T2^*$-weighted echo planar imaging was used for fMRI acquisition. The fMRI data processing and statistical analyses were carried out using SPM2. Results: Second-level analysis revealed significant increases in the extent of activation in the contralateral motor cortex including primary motor area (M1) after drug administration. The number of activated voxels in motor cortex was 173 without drug administration and the number increased to 1049 for high dose condition and 673 for steady-state condition respectively. However, there was no significant difference in the magnitude of BOLD signal change in terms of peak T value. Conclusion: The current results suggest that cerebral motor activity can be modulated by clopidogrel in healthy subjects and that fMRI is highly senstive to evidence such changes.

Design of a CMOS RFID Transponder IC Using a New Damping Circuit (새로운 감폭회로를 사용한 CMOS RFID 트랜스폰더 IC 설계)

  • O, Won-Seok;Lee, Sang-Hun;Lee, Gang-Myeong;Park, Jong-Tae;Yu, Jong-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.3
    • /
    • pp.211-219
    • /
    • 2001
  • This paper describes a read-only CMOS transponder IC for RFID applications. A full-wave rectifier implemented using NMOS transistors supplies the transponder with a dc supply voltage using the magnetic field generated from a reader. A 64-bit ROM has been designed for a data memory. Front-end impedance modulation and Manchester coding are used for transmitting the data from the transponder memory to the reader. A new damping circuit which has almost constant damping rate under the variations of the distance between the transponder and the reader has been employed for impedance modulation. The designed circuit has been fabricated using a 0.65${\mu}{\textrm}{m}$2-poly, 2-metal CMOS process. Die area is 0.9mm$\times$0.4mm. Measurement results show that it has a constant damping rate of around 20~25% and a data transmission rate of 3.9kbps at a 125KHz RF carrier. The power required for reading operation is about 100㎼. The measured reading distance is around 7cm.

  • PDF

Spin Wave Interference in Magnetic Nanostructures

  • Yang, Hyun-Soo;Kwon, Jae-Hyun;Mukherjee, Sankha Subhra;Jamali, Mahdi;Hayashi, Masamitsu
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2011.12a
    • /
    • pp.7-8
    • /
    • 2011
  • Although yttrium iron garnet (YIG) has provided a great vehicle for the study of spin waves in the past, associated difficulties in film deposition and device fabrication using YIG had limited the applicability of spin waves to practical devices. However, microfabrication techniques have made it possible to characterize both the resonant as well as the travelling characteristics of spin waves in permalloy (Py). A variety of methods have been used for measuring spin waves, including Brillouin light scattering (BLS), magneto-optic Kerr effect (MOKE), vector network analyzer ferromagnetic resonance (VNA-FMR), and pulse inductive microwave magnetometry (PIMM). PIMM is one of the most preferred methodologies of measuring travelling spin waves. In this method, an electrical impulse is applied at one of two coplanar waveguides patterned on top of oxide-insulated Py, producing a local disturbance in the magnetization of the Py. The resulting disturbance travels down the Py in the form of waves, and is inductively picked up by the other coplanar waveguide. We investigate the effect of the pulse width of excitation pulses on the generated spin wave packets using both experimental results and micromagnetic simulations. We show that spin wave packets generated from electrical pulses are a superposition of two separate spin wave packets, one generated from the rising edge and the other from the falling edge, which interfere either constructively or destructively with one another, depending upon the magnitude and direction of the field bias conditions. A method of spin wave amplitude modulation is also presented by the linear superposition of spin waves. We use interfering spin waves resulting from two closely spaced voltage impulses for the modulation of the magnitude of the resultant spin wave packets.

  • PDF

Application of Spatial Modulation of Magnetization to Cervical Spinal Stenosis for Evaluation of the Hydrodynamic Changes Occurring in Cerebrospinal Fluid

  • Kwang-Hun Lee;Tae-Sub Chung;Tae Joo Jeon;Young Hwan Kim;Daisy Chien;Gerhard Laub
    • Korean Journal of Radiology
    • /
    • v.1 no.1
    • /
    • pp.11-18
    • /
    • 2000
  • Objective: To evaluate the hydrodynamic changes occurring in cerebrospinal fluid (CSF) flow in cervical spinal stenosis using the spatial modulation of magnetization (SPAMM) technique. Materials and Methods: Using the SPAMM technique, 44 patients with cervical spinal stenosis and ten healthy volunteers were investigated. The degree of cervical spinal stenosis was rated as low-, intermediate-, or high-grade. Low-grade stenosis was defined as involving no effacement of the subarachnoid space, intermediate-grade as involving effacement of this space, and high-grade as involving effacement of this space, together with compressive myelopathy. The patterns of SPAMM stripes and CSF velocity were evaluated and compared between each type of spinal stenosis and normal spine. Results: Low-grade stenosis (n = 23) revealed displacement or discontinuity of stripes, while intermediate- (n = 10) and high-grade (n = 11) showed a continuous straight band at the stenotic segment. Among low-grade cases, 12 showed wave separation during the systolic phase. Peak systolic CSF velocity at C4-5 level in these cases was lower than in volunteers (p < .05), but jet-like CSF propulsion was maintained. Among intermediate-grade cases, peak systolic velocity at C1-2 level was lower than in the volunteer group, but the difference was not significant (p > .05). In high-grade stenosis, both diastolic and systolic velocities were significantly lower (p < .05). Conclusion: Various hydrodynamic changes occurring in CSF flow in cervical spinal stenosis were demonstrated by the SPAMM technique, and this may be a useful method for evaluating CSF hydrodynamic change in cervical spinal stenosis.

  • PDF

A Study on the Mobile Communication System for the Ultra High Speed Communication Network (초고속 정보통신망을 위한 이동수신 시스템에 관한 연구)

  • Kim, Kab-Ki;Moon, Myung-Ho;Shin, Dong-Hun;Lee, Jong-Arc
    • Journal of IKEEE
    • /
    • v.2 no.1 s.2
    • /
    • pp.1-14
    • /
    • 1998
  • In this paper, Antenna, LNA, Mixer, VCO, and Modulation/Demodulation in Baseband processor which are the RF main components in Wireless LAN system for ultra high-speed communications network are studied. Antenna bandwidth and selective fading due to multipath can be major obstacles in high speed digital communications. To solve this problem, wide band MSA which has loop-structure magnetic antenna characteristics is designed. Distributed mixer using dual-gate GaAs MESFET can achieve over 10dB LO/RF isolation without hybrid, and minimize circuit size. As linear mixing signal is produced, distortions can be decreased at baseband signals. Conversion gain is achieved by mixing and amplification simultaneously. Mixer is designed to have wide band characteristics using distributed amplifier. In VCO design, Oscillator design method by large signal analysis is used to produce stable signal. Modulation/Demodulation system in baseband processor, DS/SS technique which is robust against noise and interference is used to eliminate the effect of multipath propagation. DQPSK modulation technique with M-sequences for wideband PN spreading signals is adopted because of BER characteristic and high speed digital signal transmission.

  • PDF

The V(IV) Species, Locaton and Adsorbate Interaction in VH-SAPO-11 studied by ESR and ESEM

  • Back, Gernh-ho;Back, Seung-Chan;Park, Sung-Gun;Lee, Chul-wee
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.9 no.1
    • /
    • pp.1-20
    • /
    • 2005
  • Vanadium-incorporated aluminophophate molecular sieve VH-SAPO-11 has been studied by electron spin resonanace (ESR) and electron spin echo modulation (ESEM) spectroscopies to determine the vanadium locatin and interaction with various adsorbate molecules. As-synthsized VH-SAPO-11 contains only vanady1 species with distored octahral coordination. After calcinations in $O_2$ and exposure to moisture, only species A is observed with reduced intensities. Species A is suggested as a VO$(H_2O)_2^{2+$} complex coordinate to three framwork oxygen bonded to aluminum. When calcined, hydrate VH-SAPO-11 is dehydrated at elevated temperature, species A loses it water ligands and transforms to $VO^{2+}$ ions coordinated to three framework oxygens (species B). Species B reduces its intensities significantly after treatment with $O_2$at high temperature, thus suggesting oxidation of $v^{4+}$to $v^{5+}$. When dehydrated VH-SAPO-11 contacts with $D_2O$ at room temperature, the ESR signal of species A is observed. This species assumed as a $VO(O_f)_3(D_2O)_2$, by considering 3 framework oxygens. Adsorption of deuterated methanol on dehydrated VH-SAPO-11 results in another new vanadium species D, which is identified as a $VO(CD_{3}OH)$ complex. When deuterated ethanol is adsorbed on dehydrated VH-SAPO-11, another new vanadium species E identified as a $VO(C_{2}H_{5}OD)^{2+}$, is observed. When deuterated propanol is adsorbed on dehydrated VH-SAPO-11, a new vanadium species F identified as a $VO(C_{3}H_{7}OD)$, is observed. Possible coordination geometries of these various complexes are discussed.

  • PDF

A Neuromuscular Biomechanic Study of the Modulation of Corticospinal Excitability by Observation and/or Imagery of Action in Older Adults (장 노년층에서의 운동 연상 및 관찰에 따른 피질척수로 변화에 대한 근신경 역학적 연구)

  • Choi, Eun-Hi
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.681-688
    • /
    • 2009
  • To better delineate the changes in corticospinal excitability when older adults are asked to observe and/or imagine actions, 22 right-handed older adults without neurological abnormalities were included in this study. The amplitude and latency of motor evoked potentials (MEPs) by transcranial magnetic stimulation were recorded in the abductor pollicis brevis of the dominant hand during passive observation/imagery/active observation of slow/fast action of abduction of right thumb and also at resting state. Thus, active observation showed better changes than passive, but slow and fast action revealed no difference at all.

Multi-Secondary Transformer: A Modeling Technique for Simulation - II

  • Patel, A.;Singh, N.P.;Gupta, L.N.;Raval, B.;Oza, K.;Thakar, A.;Parmar, D.;Dhola, H.;Dave, R.;Gupta, V.;Gajjar, S.;Patel, P.J.;Baruah, U.K.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.78-82
    • /
    • 2014
  • Power Transformers with more than one secondary winding are not uncommon in industrial applications. But new classes of applications where very large number of independent secondaries are used are becoming popular in controlled converters for medium and high voltage applications. Cascade H-bridge medium voltage drives and Pulse Step Modulation (PSM) based high voltage power supplies are such applications. Regulated high voltage power supplies (Fig. 1) with 35-100 kV, 5-10 MW output range with very fast dynamics (${\mu}S$ order) uses such transformers. Such power supplies are widely used in fusion research. Here series connection of isolated voltage sources with conventional switching semiconductor devices is achieved by large number of separate transformers or by single unit of multi-secondary transformer. Naturally, a transformer having numbers of secondary windings (~40) on single core is the preferred solution due to space and cost considerations. For design and simulation analysis of such a power supply, the model of a multi-secondary transformer poses special problem to any circuit analysis software as many simulation softwares provide transformer models with limited number (3-6) of secondary windings. Multi-Secondary transformer models with 3 different schemes are available. A comparison of test results from a practical Multi-secondary transformer with a simulation model using magnetic component is found to describe the behavior closer to observed test results. Earlier models assumed magnetising inductance in a linear loss less core model although in actual it is saturable core made-up of CRGO steel laminations. This article discusses a more detailed representation of flux coupled magnetic model with saturable core properties to simulate actual transformers very close to its observed parameters in test and actual usage.

A PRML System for Perpendicular Magnetic Recording Channel in Wireless Multimedia Networks (무선 멀티미디어 네트워크에서 수직 자기기록장치를 위한 PRML 시스템)

  • Kim Jeong-so;Hwang Gi-yean
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.5
    • /
    • pp.454-457
    • /
    • 2004
  • Partial response maximum likelihood (PRML) is a powerful and indispensable detection scheme for perpendicular magnetic recording channels. The proposed method is a low complexity detection scheme which is related to the PRML system. The simulation results show that PR(1,2,3,4,3,2,1)ML and PR(l,2,3,3,2,1)ML using modulation encoding with R=2/3 have the most improved performance at K=3,4. However, in the case of K=3, R=2/3 PR(1,1,1,1)ML effectively reduces the complexity compared to PR(1,2,3,3,2,1), but it has L5dB performance degradation at most. In the case of K=4, R=l PR(1,2,2,1)ML has very low complexity compared to R=2/3 PR(l,2,3,4,3,2,1)ML. but it has about 2dB performance degradation at most.

  • PDF