• 제목/요약/키워드: Magnetic Field Reduction

검색결과 189건 처리시간 0.021초

Power Frequency Magnetic Field Reduction Method for Residents in the Vicinity of Overhead Transmission Lines Using Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Lee, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.829-835
    • /
    • 2011
  • A power frequency magnetic field reduction method using passive loop is presented. This method can be used to reduce magnetic fields generated within the restricted area near transmission lines by alternating current overhead transmission lines. A reduction algorithm is described and related equations for magnetic field reduction are explained. The proposed power frequency magnetic field reduction method is applied to a scaled-down transmission line model. The lateral distribution of reduction ratio between magnetic fields before and after passive loop installation is calculated to evaluate magnetic field reduction effects. Calculated results show that the passive loop can be used to cost-effectively reduce power frequency magnetic fields in the vicinity of transmission lines generated by overhead transmission lines, compared with other reduction methods, such as active loop, increase in transmission line height, and power transmission using underground cables.

송전 선로 극저주파 자기장 저감지수(FRF) 특성 해석 (Analysis of ELF Magnetic Field Reduction Factor of Electric Power Transmission Line)

  • 명성호;조연규;이동일;임윤석
    • 한국전자파학회논문지
    • /
    • 제17권11호
    • /
    • pp.1132-1142
    • /
    • 2006
  • 본 연구는 송전 선로 여러 가지 유형의 극저주파 자기장 저감 적용 모델을 조사하고 그 효과를 분석하였다. 본 연구에서는 154 kV 수평 배열 송전 선로를 기본으로 하여 적용 가능한 다양한 자기장 저감 모델에 대하여 적용시 얻게 되는 자기장 저감지수(Field Reduction Factor)를 검토하였다. 그 결과 compact 모델 채용시에는 상간거리 compact화 비율과 자기장 저감지수가 거의 비례하였으며, diamond 모델 및 transposed 선로 배치의 경우는 50 %에 근접한 자기장 저감이 가능하였다. 배전 선로에 적용이 가능한 삼각형 배열은 33 % 정도, 2회선 split는 50 % 정도 저감 효과가 나타나는 것으로 분석되었으며 수평 multi split 모델의 경우는 80 %까지 자기장 저감을 얻을 수 있었다.

축소 모델을 이용한 수동 루프 송전선 자기장 저감율 분석 (Analysis of ELF Magnetic Field Reduction Ratio on Passive Loop Using Scale Down Model of Transmission Line)

  • 조연규;명성호;이재복;장석훈
    • 한국전자파학회논문지
    • /
    • 제17권12호
    • /
    • pp.1231-1239
    • /
    • 2006
  • 본 연구는 수동 루프 축소 시험 장치를 이용하여 수동 루프 유형별 자기장 저감 효과를 분석하였다. 본 연구에서는 수직 2회선 선로 및 수평 선로를 대상으로 실험을 통하여 향후 실증 시험 선로에 적용할 수동 루프의 자기장 저감 효과를 검토하였다. 그 결과 수동 루프 채용으로 선로 리액턴스 보상이 없어도 50 % 이상의 송전 선로의 자기장 저감 효과를 얻을 수 있음을 확인함으로써 실증 선로 수동 루프 적용 방안을 확보하였다. 대부분 우리나라 송전 선로에 채용되는 수직 2회선 선로에서는 수평 루프보다는 수직 루프가 자기장 저감율에 보다 효과적이었으며 차폐 영역에서도 근거리뿐만 아니라 원거리까지도 효과가 좋음을 알 수 있었다. 또한, 수동 루프를 3 턴으로 설치하는 경우가 1 턴에 비해 2배정도 자기장 저감 효과가 있음을 확인하였다.

릴레이 접점의 자기적 아크 저감 분석 (Analysis of Magnetic Arc Reduction of Relay Contacts)

  • 최순호;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제32권3호
    • /
    • pp.234-240
    • /
    • 2019
  • In this work, the magnetic arc reduction phenomena encountered in AC relay contacts were analyzed. To this end, arc duration, instantaneous voltage, and current changes due to changes in the magnetic field were observed. The arc generated at the contact point was affected by the magnitude of the applied magnetic field; the voltage and current waveforms rapidly intersected, resulting in a decrease in arc duration and arc energy. Furthermore, the orientation of the N pole of the magnetic field was found to play a role in the effectiveness of potential arc prevention.

Feasibility of normal tissue dose reduction in radiotherapy using low strength magnetic field

  • Jung, Nuri Hyun;Shin, Youngseob;Jung, In-Hye;Kwak, Jungwon
    • Radiation Oncology Journal
    • /
    • 제33권3호
    • /
    • pp.226-232
    • /
    • 2015
  • Purpose: Toxicity of mucosa is one of the major concerns of radiotherapy (RT), when a target tumor is located near a mucosal lined organ. Energy of photon RT is transferred primarily by secondary electrons. If these secondary electrons could be removed in an internal cavity of mucosal lined organ, the mucosa will be spared without compromising the target tumor dose. The purpose of this study was to present a RT dose reduction in near target inner-surface (NTIS) of internal cavity, using Lorentz force of magnetic field. Materials and Methods: Tissue equivalent phantoms, composed with a cylinder shaped internal cavity, and adjacent a target tumor part, were developed. The phantoms were irradiated using 6 MV photon beam, with or without 0.3 T of perpendicular magnetic field. Two experimental models were developed: single beam model (SBM) to analyze central axis dose distributions and multiple beam model (MBM) to simulate a clinical case of prostate cancer with rectum. RT dose of NTIS of internal cavity and target tumor area (TTA) were measured. Results: With magnetic field applied, bending effect of dose distribution was visualized. The depth dose distribution of SBM showed 28.1% dose reduction of NTIS and little difference in dose of TTA with magnetic field. In MBM, cross-sectional dose of NTIS was reduced by 33.1% with magnetic field, while TTA dose were the same, irrespective of magnetic field. Conclusion: RT dose of mucosal lined organ, located near treatment target, could be modulated by perpendicular magnetic field.

자기장을 사용한 원형주상체 주위의 유동 제어 및 저항감소 (Flow Control and Drag Reduction of a Circular Cylinder by an External Magnetic Field)

  • 윤현식;전호환
    • 대한조선학회논문집
    • /
    • 제41권2호
    • /
    • pp.70-78
    • /
    • 2004
  • The present study numerically investigates two-dimensional laminar flow past a circular cylinder in an aligned magnetic field using the spectral method. Numerical simulations are performed for flow fields with Re=100 and 200 in the range of 0$\leq$N$\leq$10, where Ν is the Stuart number that is the ratio of electromagnetic force to inertial force. The present study reports the detailed information of flow quantities on the cylinder surface at different Stuart numbers. It is shown that the vortex shedding can be controlled by the magnetic force representing the Stuart number. As Ν increases, the vortex shedding becomes weaker, resulting in drag reduction whose magnitude is the largest at a critical value. In addition, as the magnetic force increases, the lift amplitude decreases, reaching zero at the critical number.

60Hz ELF 자계에 대한 고 도전율 및 고 투자율 재료의 차폐효과 분석 (Investigation of Shielding Effects of High Conductivity of High Permeability Materials on 60Hz ELF Magnetic Fields)

  • 송기현;명성호;민석원
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권4호
    • /
    • pp.166-171
    • /
    • 2005
  • Shielding methods on ELF(Extremely Low Frequency) magnetic fields may include the use of induced currents, modification of magnetic field flux patterns using high permeability and/or high conductivity materials, and others. The magnetic shielding properties of enclosures can be utilized to reduce the magnetic field of current carrying conductors. In this paper, to get a more practical understanding of shielding phenomena, we have investigated the magnetic field reduction by means of 3 dimensional numerical analysis and experiments. We found copper could reduce flux density more then permalloy in both cases of box shield and cylindrical shield. Iron under l0$\mu$T of 1 phase could reduce flux density about $20\%$ more than silicon steel, but both of them under 50$\mu$T has a similar reduction rate of $10\%$. The 3 phase horizontal model gave the highest reduction rate and the 1mm thickness iron under 10$\mu$T of 3 phase lines did lowest.

WPT 시스템의 누설자계 감소를 위한 전자파 차폐구조 개선 (Improvement of Electromagnetic Shielding Structure for Reduction of the Leakage Magnetic Field in WPT System)

  • 김종찬;이승우;강병남;홍익표;조인귀;김남
    • 한국전자파학회논문지
    • /
    • 제28권1호
    • /
    • pp.61-68
    • /
    • 2017
  • 본 논문에서는 저주파 대역에서 동작하는 무선전력전송 시스템에서 발생하는 자기장을 저감하기 위한 개선된 자기장 저감 구조를 제안하였다. 제안된 구조는 자성체와 도체로 구성되었으며, 적용된 다양한 설계 파라미터를 최적화하여 전력전송을 위한 자기장의 상쇄효과는 최소화 하면서 시스템 주변으로 누설되는 자기장 상쇄효과는 개선되도록 하였다. 무선전력전송 시스템의 효율과 주변으로 누설되는 자기장 저감 효과를 컴퓨터 시뮬레이션과 측정을 통하여 분석 및 검증을 하였다. 시뮬레이션 분석 결과, 제안된 구조가 적용된 무선전력전송 시스템의 전력전송효율은 약 77 % 수준으로 기존의 전력전송효율과 동등한 수준을 유지하였다. 또한, 고효율을 유지하는 구조들과 비교하여 최대 근접지점에서 누설되는 자기장의 세기를 약 29~37 % 저감할 수 있었다.

2선식 수동루프를 이용한 345[kV] 송전선 주변의 자계저감 설계기법 연구 (A Study on Magnetic Field Reduction Design Technique around 345 kV Transmission Line with 2-wire Set Passive Loop)

  • 김응식
    • 한국안전학회지
    • /
    • 제36권5호
    • /
    • pp.10-17
    • /
    • 2021
  • The controversy over the risk of the human body being affected by electromagnetic fields emitted from 60 Hz power lines continues without end. There are currently no new studies or research progress being made in this direction that is notable, and the number of civil complaints is gradually increasing. The problem is that each study produces different results, among which the effect of exposure to magnetic fields on childhood leukemia is a major one. In Korea, an electrician who was maintaining a 22.9 kV power line died of leukemia, which has recently been recognized as an occupational disease. Methods to reduce magnetic fields from power lines include shielding with wire loops, incorporating split phases and compaction techniques, installing underground power lines, converting to high-voltage direct current (HVDC), and increasing the ground clearance of transmission towers. Depending on whether a separate power supply is needed or not, there are two types of wire loops: passive loop and active loop. Magnetic field reduction is currently done through underground power lines; however, the disadvantage of this process is high construction costs. Installing passive loops, with relatively low construction costs, leads to lower magnetic field reduction rates than installing underground cables and a weakness to not solving the landscape problem. This methodological study aims at designing methods and reducing the effects of 2-wire set loops-the simplest and most practical. Since the method proposed in this study has been designed after analyzing the distribution of complex electromagnetic fields near the expected loop installation location, a practical design can be implemented without the need for any difficult optimization programming.

자계하의 DC 코로나 방전에 의한 NOx 제거 (NOx Removal Using DC Corona Discharge Under Magetic Field)

  • 김건호;김종달;이덕출;고희석;박재윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.462-464
    • /
    • 1995
  • In this paper, experiments were carried out to study the decrease of NOx in simulated flue gases (initial concentration of NO 1000, 750, 400 ppm, : $N_2$ balance gas). Characteristics of NOx reduction are measured and analysed in corona discharge of multi needles to plane electrode structure and magnetic field. The best characteristics of NO reduction is measured when electric and magnetic field were supplied to reactor, at same time. Consumption power applied electric and magnetic field were higher than that of discharge applied only electric field.

  • PDF