• 제목/요약/키워드: Magnetic Field

검색결과 5,586건 처리시간 0.043초

Magnetic Sensor by Using Magnetic Effect in YBaCuO Superconductor

  • 이상헌;김찬중
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.69-71
    • /
    • 2003
  • The magnetic field sensor was fabricated with superconducting ceramics of YBaCuO system. The sensor at liquid nitrogen temperature showed the increase of electrical resistance by applying magnetic field. Actually the voltage drop across the sensor was changed from zero to a value more than 100 $mutextrm{V}$ by the applied magnetic field. The change in electrical resistance depended on magnetic field. The sensitivity of this sensor was 2.9 $\Omega$/T. The sensing limit was about $1.5\times$10$^{-5}$. The increase of electrical resistance by the magnetic field was ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material. Considering the observed properties of the superconductor with trapped magnetic flux, a magnetic sensor was fabricated to detect simultaneously both the intensity and the direction of the magnetic field.

  • PDF

A Study of Magnetic Properties in $Fe_{73.9}Cu_{1.0}Nb_{3.5}Si_{14.0}B_{7.6}$ by Magnetic Annelaing

  • Kim, Eng-Chan;Kim, Jin-Eui;Nam, Hyo-Duk
    • Transactions on Electrical and Electronic Materials
    • /
    • 제1권3호
    • /
    • pp.29-33
    • /
    • 2000
  • The crystallographic and high frequency characteristics of $Fe_{73.9}Cu_{1.0}Nb_{3.5}Si_{14.0}B_{7.6}$ soft magnetic alloys were investigated under magnetic field annealing, The crystallization fraction of annealed samples with longitudinal magnetic fields is higher than that of samples without magnetic field. When the transverse magnetic field is applied, the crystallization fraction does not increases but decreases until $500^{circ}C$. It is found that for samples, the saturation induction are all same with 1.3 T. The coercive field of as-cast samples is 1.03 A/cm, but in annealed samples it decrease from 0.56 to 0.1A/cm with increasing annealing temperature from 400 to $550^{circ}C$. The squareness of annealed samples under transverse magnetic field has a small value than that of both without field and with longitudinal field annealing. It is noted that the magnetic field annealing with transverse direction to amorphous $Fe_{73.9}Cu_{1.0}Nb_{3.5}Si_{14.0}B_{7.6}$ profoundly influenced on the Mossbauer spectra in contrast to that with longitudinal direction and without magnetic field.

  • PDF

자기신호분석을 통한 차량의 감지센서와 자기형상에 관한 연구 (Magnetic Signals Analysis for Vehicle Detection Sensor and Magnetic Field Shape)

  • 최학윤
    • 한국통신학회논문지
    • /
    • 제40권2호
    • /
    • pp.349-354
    • /
    • 2015
  • 본 논문은 차량감지를 위해 자기센서를 이용하여 자기신호를 측정하고 형상을 분석한 결과에 관한 것이다. 자기센서는 하니웰사의 MR센서를 이용하였고, 센서의 성능을 알아보기 위해 3축의 길이가 1.2 m인 자기장 발생장치를 제작하여 자기장 감지능력을 측정하였다. 차량감지는 주행차로와 비 주행차로에 센서를 설치한 후 감지여부와 차체의 크기가 다른 7개 차량에 대해서 자기장을 측정하였다. 또한 SUV와 소형 차량의 주차구역과 비 주차구역에 센서를 설치하고 자기장 형상을 분석하였다. 마지막으로 차량의 각 부분별 자기장 형상을 측정하였다. 측정 결과 주행차로에 자기장 형상은 비 주행차로의 경우보다 자기장 첨두치가 크며 복잡한 형상을 보여 센서의 설치 위치로 주행차로와 주행차의 방향을 구분할 수 있었으며, 차체가 클수록 자기장의 변화가 커서 차량 종류를 식별할 수 있었다. 또한 차량의 각 부분별 자기장의 변화를 측정하여 형상을 분석하였다.

로봇을 이용한 자기장 측정 시스템 개발 (Development of Magnetic Field Mapping System Using Robot)

  • 김만길;안인석;이평기;박상배;이성환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.1018-1021
    • /
    • 2003
  • This dissertation is reference to measure visual information about the configuration of magnetic field automatically and materialize the new magnetic field mapping system for the rapid and clear measure by using of the mediocrity orthogonal robot in the three- dimensional space required the measure of magnetic field concurrently. The measuring sensor is composed to be available for the measure of three-dimensional direction of magnetic field by vertically conjoining each of three hall sensors utilized of the hall effect and installed Gaussmeter, which is devised to receive the sensor result and the robot controller, away from the measuring robot in order to minimize the affection of magnetic field. Also, the controller and Gaussmeter are composed of Use interface, RS-232C and IEEE-488.2 communication. Interface system is written in NI's LabVIEW and composed to be able to set up a measuring area, the measuring number of times, two and three-dimensional graph, the velocity of robot and the magnetic field distribution graph of each element by inputting parameters. The materialized magnetic field mapping system expert the collection of the data easily and the effect of utilizing data.

  • PDF

진공인터럽터용 다극 종자계전극의 자계분포 특성 (The Magnetic Field Characteristics of Multipolar Axial Magnetic Field type Electrodes for Vacuum Interrupter)

  • 김성일;박홍태;안희일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.92-94
    • /
    • 1999
  • This paper describes axial magnetic field characteristics of multipolar axial magnetic field type electrodes for vacuum interrupter used in vacuum circuit breaker. It was distinguished that axial magnetic field distribution in consideration of eddy current effect between electrodes by finite element method. Throughout experiment of magnetic field measurement, confirmed validity of numericla analysis.

  • PDF

전기철도 차량에 대한 극저주파 자계영역의 시간영역 측정 및 스펙트럼 분석 (Time-domain measurement and spectral analysis of low frequency magnetic field on board of rolling stock)

  • 장동욱;정상기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.263-268
    • /
    • 2008
  • The measurement of magnetic field is performed AC magnetic field emission density in driver cab and saloon's compartment of rolling stock. In order to measure magnetic-field emission, a three-axial magnetic-field sensor is used and connected to data process system. The AC magnetic field is checked and analysis through BNC output, DAQ cad and notebook PC. The spectral analysis is performed by short time Fourier transform(STFT) for time-domain emission signal.

  • PDF

황축교류자계에 의한 대기중에서의 교류 아아크의 이동에 관한 연구 (A study on the A.C. arc movement in a transverse A.C. magnetic field at atmospheric pressure)

  • 전춘생;엄기환
    • 전기의세계
    • /
    • 제24권6호
    • /
    • pp.77-84
    • /
    • 1975
  • This paper treats A.C. arc movement in a transverse A.C. magnetic field at atmospheric pressure with the purpose of selecting electrode materials and obtaining detailed data for design of A.C. air circuit breaker, plasma accelerator and plasma jet. Arc velocities in transverse magnetic field are measured by varying arc current, arc voltage, gap length, magnetic flux density and the erosion of electrode surface, which influence arc velocities. The main results are; 1)Arc velocities in transverse magnetic field have different values according to electrodes of various materials and decrease in a descending order of cold cathode, medium cathode and hot cathode. 2)Arc velocities in transverse magnetic field increases with arc current, arc voltage, gap length and magnetic flux densith and on the other hand decrease with the increase of electrode surface erosion. 3)D.C.arc velocity in D.C. magnetic field is higher than A.C. arc velocity in A.C. magnetic field of the same value.

  • PDF

BPSCCO 자기 효과 (Magnetic Characteristics of BiPbSrCaCuO Oxide Superconductor)

  • 이상헌;이성갑;이영희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.252-254
    • /
    • 2003
  • A magnetic field sensor is fabricated with superconducting ceramics system. The sensor at liquid nitrogen temperature shows the increase in electrical resistance by applying magnetic field. Actually, the voltage drop across the sensor is changed from zero to a value more than $100{\mu}V$ by the applied magnetic field. The change in electrical resistance depends on magnetic field. The sensitivity of this sensor is 2.9 ohm/T. The increase in electrical resistance by the magnetic field is ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material.

  • PDF

수직자장하에서 원관내 자성유체의 거동에 관한 연구 (A Study on the Flow Behavior of Magnetic Fluids in a Circular Pipe with a Vertical Magnetic Field)

  • 박정우;유신오;서이수
    • 대한기계학회논문집B
    • /
    • 제23권1호
    • /
    • pp.25-32
    • /
    • 1999
  • In the present paper, we theoretically analyze the flow of magnetic fluids in a circular pipe with a vertical magnetic field and investigate the magnetic response by the external magnetic field. Theoretical study through the governing equation derived by Siliomis is carried out with numerical analysis by the Gauss Elimination Method. Using polar and magnetic effect parameters, theoretical equations and distributions for the velocity, vorticity, internal angular momentum and induced magnetization as the magnetic response are shown. Especially, in the region of strong magnetic field the specific property is appeared by finding a critical magnetic effect parameter for a polar effect parameter.

VDT 작업시 자기장이 인체에 미치는 영향에 관한 연구 (An Effect of Magnetic Field on VDT Work)

  • 박재희;김철중;이남식;김진호
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1992년도 추계학술대회논문집
    • /
    • pp.77-83
    • /
    • 1992
  • The effect of magnetic field on VDT work has not been clarified yet, but many studies repoerted that magnetic field could cause of the cancers. Many developed countries have set the criteria of magnetic field and produce the VDT which has lower magnetic value. The purpose of this study was to measure the intensity of magnectic field from VDT. For this purpose three experiments were performed. The first was designed to measure the intensity of magnetic field by distances(30,60,90 cm) and directions. The second was to compare the intensities between VDT and Color TV. The last was to evaluate the eye protec- tion glasses. The reults showed that the intensity of magnetic field was lowered in proportion to the distance $r^{3}$and both lateral sides of the VDT marked high values compared to the frontal and back sides. On the same distance (30 cm) color TV marked high value to the VDT. But on the normal work distance (TV: 100 cm, VDT: 30 cm) there was little difference, Eye protection glasses could not protect the magnetic field physically.

  • PDF