• Title/Summary/Keyword: Magnetic Blowout Force

Search Result 5, Processing Time 0.023 seconds

Estimating factor for Improving Arc Extinction Capability of DC Magnetic Switch (직류전자 접촉기의 아크 소호력 향상 요인 추정)

  • Cho, Hyun-Kil;Lee, Eun-Woong;Kim, Kil-Soo;Kim, Gyun-Muk;Lim, Su-Saeng;Kim, Jun-Ho;Ryu, Jong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.18-20
    • /
    • 2001
  • This paper describes are quenching chambers of three type for Magnetic Switch and analyzes electromagnetic blowout force acting on the arc using 3D finite element method we make prototype device of each model and establish characteristics of arc quenching by measuring arcing time. This paper compares electromagnetic blowout to inverse arcing time. As the result this proposes the improving method for arc quen performance in DC magnetic switch.

  • PDF

A Study on Improving Arc Quenching Performance of MCCB by FEM (유한요소법을 이용한 배선용 차단기의 아크소호 성능향상에 관한 연구)

  • Kim, Kil-Sou;Lim, Kee-Joe;Kang, Seong-Hwa;Cho, Hyun-Kil;Lee, Gang-Won;Park, Jung-Nam
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.51-54
    • /
    • 2001
  • This Paper is described basic principles of arc quenching in Molded Case Circuit Breaker. We analyzed magnetic blowout forces acting on the arc in contact system when circuit breakers interrupt fault currents in different three models by 3-D FEM(Finite Element Method). The interrupting time simulated is compared with that of short circuit tests. The results of this study derive valid of the simulation method and present the techniques to improve arc quenching performance.

  • PDF

The Arc Extinction Capability of DC Magnetic Switch (직류 전자접촉기의 아크 소호성능 향상)

  • Cho, Hyun-Kil;Lee, Eun-Woong;Kim, Kil-Su;Lim, Su-Saeng;Kim, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.353-356
    • /
    • 2001
  • This paper describes an analysis of electromagnetic system of Magnetic Switch using 3D and 2D finite element method. The electromagnetic blowout force acting on the arc is obtained by 3D finite element method. So, we are researching the arc chamber for dc current using permanent magnet.

  • PDF

The Influence of Transverse Magnetic Field for Shortening DC Arc Time (직류 아크 소호 시간을 단축시키는 직교자계의 영향)

  • Lee, Eun-Woong;Cho, Hyun-Kil
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.3
    • /
    • pp.146-154
    • /
    • 2006
  • We derived a theory of increasing electromagnetic force which acts on arc column for reducing arcing time between electric contacts. A simulation method of arc velocity is presented by calculating blowout force using 3D FEM and drag force acting on arc column. This paper proposes 3 types arc extinguish chamber of different flux path and presents the specific electromagnetic force and arc velocity of each model by the analysis. The result of analysis and experimental proposes the prediction method of arc time when all conditions are same except external magnetic field.

The study for Improving Arc Extinction Capability of DC Magnetic Switch (직류전자 접촉기의 아크 소호력 향상)

  • Cho, Hyun-Kil;Lee, Eun-Woong;Lim, Su-Saeng;Lee, Hwa-Su;Sea, Jeong-Min;Kim, Gyun-Muk
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.888-890
    • /
    • 2002
  • We derived a theory of increasing electromagnetic force acting on arc column for reducing arcing time between electric contacts. A simulation method of arc velocity is presented by calculating blowout force using 3D FEM and drag acting on arc column. This paper is proposed 3 types arc extinguish chamber of different fulx path and is presented electromagnetic force and arc velocity of each model.

  • PDF