• 제목/요약/키워드: Magnetic Alignment Torque

검색결과 5건 처리시간 0.021초

매입형 영구자석 동기전동기의 일정 토크 영역에서 최대 토오크 운전에 관한 연구 (Study of Maximum Torque Operation of Interior Permanent Magnet Synchronous Motor in Constant Torque Region)

  • 김장목;김수열;류호선;임익훈
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.195-203
    • /
    • 2000
  • In this paper a new controller is proposed to operate the interior permanent magnet synchronous motor(IPMSM) by the control method of the maximum torque per ampere in constant torque region. The implementation method of the conventional torque controller is explained and analyzed exactly. The proposed controller does not use the torque and q-axis current of the speed controller but the amplitude of the stator current in order to utilize not only the magnetic alignment torque but also the reluctance in the constant region, gurantees the linearity of the torque, and is easily implemented. These attractive are verified through the experiment.

  • PDF

FEM을 이용한 영구자석형 릴럭턴스 동기전동기의 자속 장벽 설계에 대한 연구 (A Study on Flux Barrier of Permanent Magnet Assisted Reluctance Synchronous Motor Design using FEM)

  • 김남훈;남상현;최경호
    • 전력전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.295-302
    • /
    • 2008
  • 본 논문에서는 세탁기용으로 사용될 영구자석형 릴럭턴스 동기전동기(permanent-magnet assisted reluctance synchronous motor : PMA-RSM)의 설계와 특성에 대해서 살펴본다. 제안된 PMA-RSM의 특성과 최대 토크 특성을 알아보기 위해서 유한 요소법(finite element method)을 이용 하였다. 저속 구간에서의 충분한 토크를 발생시키기 위해서 회전자의 구조는 릴럭턴스 토크를 만들어내는 돌극 구조와 회전자 내부의 공극에 영구자석을 삽입하는 구조로 구성되어 있다. 전형적인 자속 장벽형(Flux barrier type) 릴럭턴스 동기전동기(RSM : Reluctance Synchronous Motor)와 자속 장벽(Flux barrier)에 자석을 삽입한 경우에 발생되는 현상들에 대해서 비교 분석하고, 또한 제안된 PMA-RSM의 릴럭턴스 토크(reluctance torque)와 자석에 의한 자석 토크(magnetic alignment torque)가 서로 최대가 되는 시점을 시뮬레이션을 통하여 구하며, 그 결과를 이용하여 전동기의 특성, 평균토크 그리고 토크 리플에 대해서 유한 요소법을 통하여 살펴보았다.

플라스틱 자석 혼합물의 균질도 평가방법과 균질도가 자기특성에 미치는 영향 (Evaluation Methods of Homogeneity for Feedstocks and Effect of Homogeneity on the Magnetic Properties of Plastic Magnets)

  • 이석희;최준환;문탁진;정원용
    • 한국자기학회지
    • /
    • 제8권2호
    • /
    • pp.86-92
    • /
    • 1998
  • 플라스틱 자석에는 균일한 자장분포와 높은 자기특성을 얻기 위해서는 균질화된 혼합물이 요구되며, 이를 위해서는 적절한 혼합경로와 혼합물의 균질도 평가방법이 필수적이다. 본 연구에서는 Sr-ferrite/EVA 플라스틱 자석에서 혼합균질도의 평가방법과 혼합균질도가 자기특성에 미치는 영향을 조사하였다. 회분식 혼합기와 단축압출기를 이용하여 균질도가 서로 다른 혼합균질도를 조사하였다. 토크센서를 이요한 혼합시 토크변화 측정방법은 임계분말충전율 결정에는 효과적인데 반해 혼합균질도 평가에는 적합하지 않았다. 이그이방성 플라스틱 자석의 분말이방화율을 이용한 균질도 평가방법은 정밀도는 높으나, 시편제조와 측정에 고가의 장비와 필요하고 자성분말 혼합물 이외에는 이용될수 없다. 모세관 레오미터를 이용한 압출압력변화 측정방법은 정밀도가 높고 측정이 간편하여 효과적이었다. 혼합물의 균질도가 증가함에 따라 분말이방화율이 증가하였으며, 분말이방화율의 증가에 따라 잔류자속밀도는 직선적으로 증가하였다.

  • PDF

POLARIZATION OF FIR EMISSION FROM T TAURI DISKS

  • Cho, Jung-Yeon;Lazarian, A.
    • 천문학회지
    • /
    • 제40권4호
    • /
    • pp.113-118
    • /
    • 2007
  • Recently far infra-red (FIR) polarization of the $850{\mu}m$ continuum emission from T Tauri disks has been detected. The observed degree of polarization is around 3 %. Since thermal emission from dust grains dominates the spectral energy distribution at the FIR regime, dust grains might be the cause of the polarization. We explore alignment of dust grains by radiative torque in T Tauri disks and provide predictions for polarized emission for disks viewed at different wavelengths and viewing angles. In the presence of magnetic field, these aligned grains produce polarized emission in infrared wavelengths. When we take a Mathis-Rumpl-Nordsieck-type distribution with maximum grain size of $500-1000{\mu}m$, the degree of polarization is around 2-3 % level at wavelengths larger than ${\sim}100{\mu}m$. Our study indicates that multifrequency infrared polarimetric studies of protostellar disks can provide good insights into the details of their magnetic structure.

Bone-Anchored Hearing Aid Implant에 대한 1.5 T와 3.0 T에서 MRI 안전성의 생체외 평가 (In Vitro Assessment of MRI Safety at 1.5 T and 3.0 T for Bone-Anchored Hearing Aid Implant)

  • 연규진;김현수;이승근;이태수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.19-25
    • /
    • 2017
  • 본 연구는 1.5 T와 3.0 T Magnetic Resonance Imaging에서 Bone-Anchored Hearing Aid (BAHA) implant의 수평인력, 회전력, 그리고 자화감수성 인공물의 크기를 표준측정 방법에 의해 측정하여 MR 안전성을 평가하였다. BAHA implant의 고정장치와 지지대는 0.5%의 철(iron)이 포함 된 티타늄으로 만들어졌으며, 길이는 10 mm (고정장치 4 mm, 지지대 6 mm), 최대 직경은 7.0 mm이다. 수평인력 측정장치와 자화감수성 인공물 측정장치는 각각 American Society for Testing and Materials (ASTM) F2052-06, F2119-07을 참조하여 아크릴을 이용해 제작했으며, 회전력 측정은 원형 플라스틱 용기를 이용한 측정장치를 사용하였다. 자기유도에 의한 BAHA implnat의 수평인력은 주자장이 가장 큰 지점인 96 cm지점에서 최대 변위각을 측정하였고, 회전력은 원형용기 내부의 $45^{\circ}$간격의 실선 위에 놓았을 때 나타난 회전형태를 정성적 평가기준으로 측정하였다. 자화감수성 인공물은 황산구리($CuS0_4$) 용액이 채워진 용기의 중앙에 BAHA implant를 매달아 영상을 획득한 후 Susceptibility Artifact Measurement (SAM) software를 이용해 크기를 측정하였다. 측정결과 수평인력은 1.5 T와 3.0 T에서 변위각과 변위력은 모두 0으로 나타났다. 회전력은 1.5 T에서는 0(no torque), 3.0 T에서는 +1(mild torque)로 나타났다. 자화감수성 인공물은 최소 13.20 mm, 최대 38.91 mm의 크기로 나타났다. 따라서 1.5 T, 3.0 T의 MR 환경에서 BAHA implant는 환자에게 안전하다.