• 제목/요약/키워드: Machining elasticity

검색결과 23건 처리시간 0.016초

PDP 격벽 성형용 몰드 제작과 성형에 대한 연구 (A Study on Mold Fabrication and Forming for PDP Barrier Ribs)

  • 조인호;정상철;정해도;손재혁
    • 한국정밀공학회지
    • /
    • 제18권5호
    • /
    • pp.171-176
    • /
    • 2001
  • Plasma Display Panel(PDP) is a type of flat panel display utilizing the light emission produced by gas discharge. Barrier Ribs of PDP separating each sub-pixel prevents optical and electrical crosstalks from adjacent sub-pixels. Mold for forming barrier ribs has been newly researched to overcome the disadvantages of conventional manufacturing process such as screen printing, sand-blasting and photosensitive glass methods. Mold for PDP barrier ribs have stripes of micro grooves transferring glass-material wall. In this paper, Stripes of grooves of which width 48${\mu}{\textrm}{m}$ and 270${\mu}{\textrm}{m}$, depth 124${\mu}{\textrm}{m}$, pitch 274${\mu}{\textrm}{m}$ was acquired by machining hard and brittle materials of WC, Silicon, Alumina with dicing saw blade. Maximum roughness of the bottom and sidewall of the grooves was respectively 120nm, 287nm in grooving WC. Maximum tilt angle caused by difference between upper-most width and lower-most width was 2$^{\circ}$. Maximum Radius of bottom curvatures was 7.75${\mu}{\textrm}{m}$. This results satisfies the specification for barrier ribs of 50 inch XGA PDP if the groove form of mold was fully transferred to the barrier ribs. Barrier ribs were formed with Silicone rubber mold, which is transferred from grooved hard materials. Silicone rubber mold has elasticity accommodating the waveness of lower glass plate of PDP.

  • PDF

사파이어 의료용 나이프의 연삭가공에서 지그의 탄성계수가 날 부 형상에 미치는 영향 : 제2보 탄성계수와 치핑 현상의 검증 (Effect of the Elasticity Modulus of the Jig Material on the Blade Edge Shape in the Grinding Process of Sapphire Medical Knife - Part 2 Verification of the Chipping Phenomenon and Elastic Modulus of the Jig Material)

  • 신건휘;강병욱;곽태수
    • 한국기계가공학회지
    • /
    • 제16권5호
    • /
    • pp.63-68
    • /
    • 2017
  • This study determines the selection of an appropriate jig material for the blade edge of the medical sapphire knife. The physical properties of the jig material affects the edge shape and chipping phenomenon in machining of the medical sapphire knife. If a grinding wheel is used, brittle workpieces such as sapphire are easily damaged by the propagation of cracks because the grinding force significantly increases. It is important to constantly maintain the grinding force in the grinding process of the brittle materials. The grinding force can be kept constantly by inducing the elastic deformation of the Jig material because the elastic deformation of brittle work-piece is negligibly low. The chipping phenomenon may be reduced by selecting the proper Jig material. Aluminum, copper, stainless steels and carbon steel were used as Jig materials. The experiment was conducted using a cast iron grinding wheel, which was installed on a conventional grinding machine with the ELID grinding system. The thickness and width of the chipping area were measured using an optical microscope and FE-SEM to analyze the shape of the blade edge. According to the experiment result, the chipping phenomenon decreased, and the sharp edge was formed when the jig materials with low elastic modulus were used.

Characteristics of Rhenium-Iridium coating thin film on tungsten carbide by multi-target sputter

  • Cheon, Min-Woo;Kim, Tae-Gon;Park, Yong-Pil
    • Journal of Ceramic Processing Research
    • /
    • 제13권spc2호
    • /
    • pp.328-331
    • /
    • 2012
  • With the recent development of super-precision optical instruments, camera modules for devices, such as portable terminals and digital camera lenses, are increasingly being used. Since an optical lens is usually produced by high-temperature compression molding methods using tungsten carbide (WC) alloy molding cores, it is necessary to develop and study technology for super-precision processing of molding cores and coatings for the core surface. In this study, Rhenium-Iridium (Re-Ir) thin films were deposited onto a WC molding core using a sputtering system. The Re-Ir thin films were prepared by a multi-target sputtering technique, using iridium, rhenium, and chromium as the sources. Argon and nitrogen were introduced through an inlet into the chamber to be the plasma and reactive gases. The Re-Ir thin films were prepared with targets having a composition ratio of 30 : 70, and the Re-Ir thin films were formed with a 240 nm thickness. Re-Ir thin films on WC molding core were analyzed by scanning electron microscope (SEM), atomic force microscope (AFM), and Ra (the arithmetical average surface roughness). Also, adhesion strength and coefficient friction of Re-Ir thin films were examined. The Re-Ir coating technique has received intensive attention in the coating processes field because of promising features, such as hardness, high elasticity, abrasion resistance and mechanical stability that result from the process. Re-Ir coating technique has also been applied widely in industrial and biomedical applications. In this study, WC molding core was manufactured, using high-performance precision machining and the effects of the Re-Ir coating on the surface roughness.