• Title/Summary/Keyword: Machine-to-machine (M2M)

Search Result 1,081, Processing Time 0.041 seconds

Design of Cloud-Based Data Analysis System for Culture Medium Management in Smart Greenhouses (스마트온실 배양액 관리를 위한 클라우드 기반 데이터 분석시스템 설계)

  • Heo, Jeong-Wook;Park, Kyeong-Hun;Lee, Jae-Su;Hong, Seung-Gil;Lee, Gong-In;Baek, Jeong-Hyun
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.251-259
    • /
    • 2018
  • BACKGROUND: Various culture media have been used for hydroponic cultures of horticultural plants under the smart greenhouses with natural and artificial light types. Management of the culture medium for the control of medium amounts and/or necessary components absorbed by plants during the cultivation period is performed with ICT (Information and Communication Technology) and/or IoT (Internet of Things) in a smart farm system. This study was conducted to develop the cloud-based data analysis system for effective management of culture medium applying to hydroponic culture and plant growth in smart greenhouses. METHODS AND RESULTS: Conventional inorganic Yamazaki and organic media derived from agricultural byproducts such as a immature fruit, leaf, or stem were used for hydroponic culture media. Component changes of the solutions according to the growth stage were monitored and plant growth was observed. Red and green lettuce seedlings (Lactuca sativa L.) which developed 2~3 true leaves were considered as plant materials. The seedlings were hydroponically grown in the smart greenhouse with fluorescent and light-emitting diodes (LEDs) lights of $150{\mu}mol/m^2/s$ light intensity for 35 days. Growth data of the seedlings were classified and stored to develop the relational database in the virtual machine which was generated from an open stack cloud system on the base of growth parameter. Relation of the plant growth and nutrient absorption pattern of 9 inorganic components inside the media during the cultivation period was investigated. The stored data associated with component changes and growth parameters were visualized on the web through the web framework and Node JS. CONCLUSION: Time-series changes of inorganic components in the culture media were observed. The increases of the unfolded leaves or fresh weight of the seedlings were mainly dependent on the macroelements such as a $NO_3-N$, and affected by the different inorganic and organic media. Though the data analysis system was developed, actual measurement data were offered by using the user smart device, and analysis and comparison of the data were visualized graphically in time series based on the cloud database. Agricultural management in data visualization and/or plant growth can be implemented by the data analysis system under whole agricultural sites regardless of various culture environmental changes.

Effect of modeling liquid on the shear-bond strength of zirconia core - porcelain veneer (도재 전용액이 지르코니아 코어-도재 비니어의 전단결합강도에 미치는 영향)

  • Choi, Byung-Hwan;Kim, Im-Sun
    • Journal of Technologic Dentistry
    • /
    • v.36 no.2
    • /
    • pp.83-89
    • /
    • 2014
  • Purpose: This study is to evaluate the effect of modeling liquid on the shear-bond strength between zirconia core and veneering ceramic. Methods: Disk-shaped (diameter: 12.0mm; height: 3.0mm) zirconia were randomly divided into six groups according to the surface conditioning method and whether modeling liquid is used or not to be applied (N=60, n=10 per group): group 1-control group with distilled water(ZD); group 2-control group with modeling liquid(ZM); group 3-airborne particle abrasion with $110-{\mu}m$ $Al_2O_3$(AD) with distilled water; group 4-airborne particle abrasion with $110-{\mu}m$ $Al_2O_3$ with modeling liquid(AM); group 5-liner with distilled water(LD); group $6{\pounds}{\neq}liner$ with modeling liquid(LM). Contact angles were determined by the sessile drop method at room temperature using a contact angle measurement apparatus. The specimens were prepared using dentin veneering ceramics, veneered, 3mm high and 2.8mm in diameter, over the cores. The shear bond strength test was performed in a Shear bond test machine. Load was applied at a cross-head speed of 0.50mm/min until failure. The fractured zirconia surfaces were evaluated by using stereomicroscope (${\times}30$). Collected data were analyzed using SPSS(Statistical Package for Social Sciences) Win 12.0 statistics program. Results: ZD showed the highest contact angle($50.6{\pm}5.4^{\circ}$) and LD showed the lowest value($6.7{\pm}1.3^{\circ}$). Control groups and zirconia liner groups were significantly higher contact angle than liner groups(p<0.05). LD was the highest shear bond strength($43.9{\pm}3.8MPa$) and ZD was the lowest shear bond strength($24.8{\pm}4.9MPa$). Shear bond strengths of control groups and contact angle of liner groups were not significantly different((p>0.05). Liner groups presented adhesive failures. The others groups showed cohesive and adhesive failures. Conclusion: Modeling liquid groups showed lower contact angles and lower shear bond strength compared to those of distilled water groups.

A STUDY ON THE SHAR BOND STRENGTH OF LIGHT-CURED GLASS IONOMER CEMENTS TO DENTIN ACCORDING TO CURING TIME INDUCED BY ARGON LASER (아르곤 레이저의 조사시간에 따른 광중합형 글래스 아이오노머 시멘트의 상아질에 대한 전단결합강도에 관한 연구)

  • Cho, Young-Lin;Hwang, Ho-Keel;Cho, Young-Gon;Oh, Haeng-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.267-277
    • /
    • 1997
  • The purpose of this study was to evaluate the shear bond strength of light-cured glass ionomer cements to dentin surface according to curing time induced by argon laser. In this study, 160 extracted human molars with sound crown were used. The dentin surface of these teeth were exposed with high speed diamond bur under water spray and polished with 120, 320, 400, 800, 1200 grits sand paper. 160 extracted human molars were randomly assigned into four groups (control, experimental 1, 2 & 3) with 40 teeth each. Control group used a visible light curing unit, XL 1000(3M Co., U.S.A) and experimental groups used argon laser($SPECTRUM^{TM}$). And then each group subdivided into two groups (A, B) according to filling materials. Subdivided A group used Fuji II LC(GC Co., Japan), B group used Vitremer(3M Co., U.S.A). The curing units and curing time of each group were as follows : Control group : visible light, 40 seconds Experimental group 1 Experimental group 2 Experimental group 3 : argon laser, 10 seconds : argon laser, 20 seconds : argon laser, 30 seconds The glass ionomer cements were bonded to dentin surface of each specimen. The specimens were stored in 100% relative humidity at 37"c for 7days. And then, the shear bond strength were measured by universal testing machine(Shimatzu Co. Japan) at crosshead speed of 5mm/min and 100kg in full scale and analyzed statistically. The following results were obtained : 1. Experimental group 2-A showed the highest shear bond strength with $9.87{\pm}1.24$ kgf and control group B showed the lowest shear bond strength with $4.08{\pm}0.78$ kgf(P<0.01). 2. The Fuji II LC showed higher shear bond strength with $9.49{\pm}1.24$ kgf than that of the Vitremer with $4.23{\pm}1.24$ kgf. There was significant difference between Fuji II LC and Vitremer(p<0.01). 3. There was no significant differences among experimental groups according to curing time induced by argon laser. 4. There was no significant differences between control group and experimental groups according to curing units.

  • PDF

INFLUENCE OF LIGHT IRRADIATION OVER SELF-PRIMING ADHESIVE ON DENTIN BONDING (상아질접착제에 대한 광조사가 접착에 미치는 영향)

  • 류현욱;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.409-417
    • /
    • 2001
  • The purpose of this study was to investigate the influence of light irradiation over self-priming adhesive on dentin bonding. After acid etching the exposed dentin, a self-priming adhesive (Prime&Bond$^{\circledR}$NT dental adhesive system Dentsply DeTrey, GmbH, Konstanz, Germany) was applied and light irradiation was done for 20 sec with regular intensity (600 mW/$\textrm{cm}^2$) in group I and for 3 sec with ultra-high intensity (1930 mW/$\textrm{cm}^2$) in group III. No light irradiation was done over self-priming adhesive in groups II and IV. Composite resin was added on the self-priming adhesive and irradiated for 40 sec with regular intensity (600 mW/$\textrm{cm}^2$) in groups I and II and for 3 sec with ultra-high intensity (1930 mW/$\textrm{cm}^2$) in groups III and IV. To see the effect of light curing time on dentin bonding, another 3 group specimens were prepared. Without light-irradiation over self-priming adhesive, added composite resin was irradiated for 3, 6, or 12 sec with ultra-high intensity light. After bonded specimens were stored in 37$^{\circ}C$ distilled water for 24 hours, shear bond strength were measured using a universal testing machine (4202, Instron, Instron Co., U.S.A.) and fractured surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan). Statistical analysis were done with one-way, two-way ANOVA and chi-square test. The results were as follows : 1. The shear bond strengths from the groups irradiated over self-priming adhesive were significantly higher than those from the groups without irradiation (p<0.05). 2. There was no significant shear bond strength difference between regular intensity light irradiation groups and ultra-high intensity ones (p>0.05). 3. There was no significant shear bond strength difference among various irradiation time groups with ultra-high intensity ones (p>0.05). 4. In stereomicroscopic examination of fractured surfaces, adhesive-cohesive mixed failure mode was mostly seen in all groups, and there was no significant difference in failure mode among groups (p>0.05).

  • PDF

THE VIDEODENSITOMETRIC ANALYSIS OF THE RADIOGRAPHIC DENSITY AND CONTRAST (Videodensitometry법을 이용한 X선사진의 흑화도와 대조도에 관한 연구)

  • Yoo Young Sun;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.293-303
    • /
    • 1992
  • Generally the patient's absorb dose and readability of radiograms are affected by the exposure time and kVp of which are related with the radiographic density and contrast The investigator carried studies to know the adequate level of exposure time and kVp to obtain the better readability of radiograms. In these studies dried human mandible with selfcuring acrylic resins attached with aluminum step wedge was used and readability of radiograms were compared with each other by videodensitometry among various combination sets of the exposure time, such as 5, 6, 8, 12, 15, 19, 24, 30, 38, 48 and 60, and varing level of kVp, such as 60, 65, 70, 80 and 90 respectively. The obtained results were as follows: 1. As exposure time and kVp were increased, radiographic density of radiograms was increased. 2. The subject contrast was increased where aluminum step wedge was thin and reduced in the reversed condition. At the thin aluminum step wedge, subject contrast was increased at the condition of lower kilovoltage than that of higher kilovoltage. 3. In the case of non-constant radiographic density, the radiographic contrast was reduced with the increment kilovoltage. The radiographic contrast was increased in the lower kilovoltage with the longer exposure time and the higher kilovoltage with the shorter exposure time. 4. At the condition of short exposure time, better readability of each reading item was obtained with the increment of the kilovoltage but at the opposite condition increasing exposure time worsened readability of radiograms. Since X-ray machine in the current dental clinics is fixed between the range of 60-70kVp and 10mA, good radiograms can be obtained by varied exposure time. But according to the conclusion of these studies, better radiograms can be obtained by using filtered high kVp and then the absorb dose to patient and exposure time can be reduced.

  • PDF

THE EFFECT OF THERMOCYCLING ON BOND STRENGTH BETWEEN METAL AND RESIN CEMENT (Thermocycling이 금속과 레진시멘트간의 결합강도에 미치는 영향)

  • Kang, Geon-Gu;Chung, Kwan-Ho;Choi, Jeong-Ho;Ahn, Seung-Geun;Song, Kwang-Yeob;Park, Chan-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.233-245
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of thermocycling on bond strength between metal and resin cement according to thermocycling, and to observe the bond failure modes with optical microscope(X30). For this purpose, Super-Bond C & B and Panavia 21 resin cement were used. Metal specimens were made of Vera-Bond and the surface of specimens were sandblasted with $50{\mu}m$ aluminum oxide. All experimental groups were stored in $37^{\circ}C$ distilled water for 72 hours, followed by thermocycling between $5^{\circ}C$ and $55^{\circ}C$ with 15 second dwell time. 500, 1000, 2000 cycles of thermocycling were executed and the tensile bond strength was measured by Instron Universal Testing Machine(Model 4201) The obtained results were as follows : 1. Super-Bond C & B and Panavia 21 did not show statistically significant difference accor-ding to thermocycling test(P>0.05). 2. Super-Bond C & B specimens exhibited statistically significant higher tensile bond stre-ngth than Panavia 21 for all experimental groups(P<0.05). 3. Super-Bond C & B exhibited mixed mode failure with partial adhesive and partial cohe-sive failure, and most of Panavia 21 exhibited cohesive failure and some mixed mode failure.

  • PDF

Fast Neutron Beam Dosimetry (속중성자선의 선량분포에 관한 연구)

  • 지영훈;이동한;류성렬;권수일;신동오;박성용
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.45-57
    • /
    • 1997
  • It is mandatory to measure accurately the dose distribution and the total absorbed dose of fast neutron for putting it to the clinical use. At present the methods of measurement of fast neutron are proposed largely by American Associations of Physicists in Medicine, European Clinical Neutron Dosimetry Group, and International Commission on Radiation Units and Measurements. The complexity of measurement, however, induces the methodological differences between them. In our study, therefore, we tried to establish a unique technique of measurement by means of measuring the emitted doses and the dose distribution of fast neutron beam from neutron therapy machine, and to invent a standard method of measurement adequate to our situation. For measuring the absorbed doses and the dose distribution of fast neutron beam, we used IC-17 and IC-18 ion chambers manufactured by A-150 plastic(tissue-equivalent material), IC-17M ion chamber manufactured by magnesium, TE gas and Ar gas, and RDM 2A electrometer. The magnitude of gamma-contamination intermingled with fast neutron beam was about 13% at 5cm depth of standard irradiated field, and increased as the depth was increased. At the central axis the maximum dose depth and 50% dose depth were 1.32cm and 14.8cm, respectively. The surface dose rate was 41.6-54.1% throughout the entire irradiated fields and increased as the irradiated fields were increased. Beam profile was that the horn effect of about 7.5% appeared at 2.5cm depth and the flattest at 10cm depth.

  • PDF

EFFECT OF DENTIN SURFACE WETNESS ON TENSILE BOND STRENGTH OF SELF ADHESIVE RESIN CEMENTS (상아질 표면 젖음성이 수종 자가접착레진시멘트의 인장접착강도에 미치는 영향)

  • Yoon, Sung-Young;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.113-119
    • /
    • 2009
  • The purpose of this study was to compare the tensile bond strength of several self-adhesive resin cements bonded to dentin surfaces with different wet conditions. Three self-adhesive resin cements: Rely-X Unicem (3M ESPE, St. Paul, MN. USA). Embrace Wetbond (Pulpdent. Oakland. MA. USA). Maxcem (Kerr. Orange. CA. USA) were used. Extracted sixty human molars were used. Each self-adhesive resin cement was adhered to the dentin specimens (two rectangular sticks from each molar) in different wet conditions. Tensile bond strength were measured using universal testing machine (EZ Test. Shimadzu corporation. Kyoto. Japan) at a crosshead speed of 1.0mm/min. After the testing. bonding failures of specimens were observed by Operative microscope (OPMI pro, Carl Zeiss. Oberkochen, Germany). T-test was used to evaluate the effect of dentin surface wetness. One-way ANOVA test was used to evaluate the tensile bond strength of self-adhesive resin cements in the same condition. Scheffe's test was used for statistical analyzing at the 95% level of confidence. The result showed that wetness of dentin surface didn't affect tensile bond strength of self-adhesive resin cements and Maxcem showed the lowest tensile bond strength.

A Study on the Thermal Conductivity of Inorganic Insulation Properties According to the Binder Types (바인더 종류에 따른 무기단열재의 열전도 특성에 관한 연구)

  • Jeon, Chanki;Lee, Jaeseong;Chung, Hoon;Park, Jongpil;Shim, Jaeyeong
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.3
    • /
    • pp.286-291
    • /
    • 2016
  • In this study, we conducted about the manufacture of a non-combustible inorganic insulation by replacing the binder type for satisfaction of thermal conductivity for developing a lightweight inorganic insulation. Thermal conductivity was measured using a machine of HFM-436. We made samples are inorganic insulation by using SH-1(liquid) of S company and SH-2(solids). By Mixing Pearlite and SH-4(Liquid) was produced as insulation sample 2. Each was shaped into a binder and pearlite in the frame. After complete drying, thermal conductivity was measured by using HFM-435. The thermal conductivity was determined using two different binder. We analyzed the effect on thermal conductivity in binder.

Studies on the Development of Compound Fertilizer for Raising Rice Seedling in Trays for Machine Transplanting -I. Manufacture of Compound Fertilizer (수도상자육묘용(水稻箱子育苗用) 전용복합비료(專用複合肥料) 개발연구(開發硏究) -I. 비료(肥料) 제조시험(製造詩驗))

  • Choi, Du-Hoi;Yuk, Chang-Soo;Shin, Jae-Sung;Han, Ki-Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.22 no.2
    • /
    • pp.100-104
    • /
    • 1989
  • This study was carried out in order to develop a compound fertilizer for raising rice seedling in trays. A compound fertilizer, a trail product, was manufactured using the major fertilizer sources of ammonium sulfate, diammonium phosphate and potassium chloride in combination with zeolite and glutamic acid fermentation waste. Besides, polyacrylamide for slow release control of the fertilzer and Tachigaren and sulfuric acid for reducing the occurrence of seedling rot were used. The component ratios of N, $P_2O_5$ and $K_2O$ of trial product were 4.19, 5.41 and 4.05 percent respectively. The dissolution rate of nitrogen component in water for the trial product with polyacrylamide was lower about fifteen percents than the product without polyacylamide in six hours. Hymexazole, main component of Thachigaren, from the product was released about 86.2 percents in forty eight hours. When the product with polyacylamide applied on red earth soil and paddy soil, the pH of soil ranged from 4.6 to 5.4 for 25 days experiment.

  • PDF