• Title/Summary/Keyword: Machine-to-machine (M2M)

Search Result 1,081, Processing Time 0.042 seconds

역극성시 금속수지복합체와 세라믹수지복합체의 형상방전가공 특성

  • 우정윤
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.52-57
    • /
    • 1996
  • Conductive Ceramic Matrix Composite(CMC) of TIC/Al2O3 and Metal Matrix Composite (MMC) of SiC/Al were experienced by the die sinking Electrical Discharge Machining(EDM) for different current and duty factor according to negative polarity. Inthis experimental study Material Removal Rate(MRR) maximum surface roughness four point bending stress distribution and Scanning Electron Microscopy(SEM) Photographs were analysed. the higher MRR was obtained for CMC than MMC but slowly decreased around duty factor of 0.67 for MMC and better surface morphology was found CMC than MMC. The SEM photographs of discharge traces for CMC showe uniform shape about 100 to 200${\mu}{\textrm}{m}$ in diameter but MMC showed irregular shape.

  • PDF

Calculation of Inviscid Flows and Performance Prediction of Radial Turbomachine (반경류 터보기계 회전차 내의 비점성 유동해석 및 성능예측)

  • Kang, S.H.;Kim, Y.H.;Choi, M.R.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.199-207
    • /
    • 1990
  • Inviscid flows in a radial turbomachine and its performance are predicted by using a pannel method. Possibility of the method to be used for design purpose is investigated. The flows in a radial turbomachine are reasonably simulated with several off-design flow rates. The diameter ratio of the rotor and inlet and outlet vane angles are systematically changed so that performance of the machine in various designs are predicted. All the predictions are shown to be in the range of Cordier curve. On the other hand, calculated slip factors are also in good agreement with values given by an empirical formula.

  • PDF

Development of a High Brightness Ion Beam Extraction System using Micro-size Aperture (마이크로 사이즈 인출구경을 이용한 고휘도 이온빔 인출 시스템 개발)

  • Kim Yoon-Jae;Park Dong-Hee;Jeong Hyeong-Seol;Hwang Yong-Seok
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.19-23
    • /
    • 2005
  • In order to develop a high brightness ion source using plasma, the ion beam extraction system with an aperture of $100{\mu}m$ in diameter has been designed and constructed. It is observed that over 500nA of He ion beam current can be extracted. With such an optimized condition, $\~10^3\;A/cm^2sr$ beam brightness can be measured by emittance scanner, which is believed to be a promising result for developing next generation FIB.

  • PDF

Dynamic Material Property of the Sinter-Forged Cu-Cr Alloys with the Variation of Chrome Content (구리-크롬 소결단조 합금의 크롬 함유량 변화에 따른 동적 물성특성)

  • Song Jung-Han;Huh Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.6 s.249
    • /
    • pp.670-677
    • /
    • 2006
  • Vacuum interrupters are used in various switch-gear components such as circuit breakers, distribution switches, contactors. The electrodes of a vacuum interrupter are manufactured of sinter-forged Cu-Cr material for good electrical and mechanical characteristics. Since the closing velocity is 1-2m/s and impact deformation of the electrode depends on the strain-rate at the given velocity, the dynamic material property of the sinter-forged Cu-Cr alloy is important to design the vacuum interrupter reliably and to identify the impact characteristics of a vacuum interrupter accurately. This paper is concerned with the dynamic material properties of sinter-forged Cu-Cr alloy for various strain rates. The amount of chrome is varied from 10 wt% to 30 wt% in order to investigate the influence of the chrome content on the dynamic material property. The high speed tensile test machine is utilized in order to identify the dynamic property of the Cu-Cr alloy at the intermediate strain-rate and the split Hopkinson pressure bar is used at the high strain-rate. Experimental results from both the quasi-static and the high strain-rate up to the 5000/sec are interpolated with respect to the amount of chrome in order to construct the Johnson-Cook and the modified Johnson-Cook model as the constitutive relation that should be applied to numerical simulation of the impact behavior of electrodes.

THE STUDY OF PATIENT EXPOSURE AND PROTECTION FROM DENTAL RADIOGRAPHY (치과 X선 촬영에 있어서 환자에 대한 피폭과 방어에 관한 연구)

  • Park T. W.
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.9 no.1
    • /
    • pp.25-31
    • /
    • 1979
  • The utilization of x-ray for diagnosis and examination is increasing by about 5-15% every year, therefore, it would be mandatory to protect the patients from exposures and so, studies in this field are performed even now. In dental field, the area of irradiation is limited any to the head and neck area, but the irradiated angle is varied following the objected tooth, so the adjacent structures lens and thyroid gland would be fragile to radiation. And the scattered radiation is one of the complicated problems in the protection because of specificity of dental x-ray and its object structures. The author, by using TLD (Thermo luminescent Dosimeter; Teledyne Isotopes-Model 7300, Element; TLD 200(CaF₂:Dy) and Capintec(Capintec Model 192, PM-30 Diagnostic chamber 28㎖ active volume), tried a measurement of air dose distribution of the scattered radiation and the irradiated dose of lens and thyroid gland under the condition of taking the film on the left maxillary molar. The results were as follows: 1. The half value layer of adapted dental x-ray machine was measured, and is 1.44㎜ Al. 2. The time of irradiation on the left maxillary molar in the Alderson Rando Phantom, the measured doses of left and right lens, and thyroid gland were 8,9mR, 1,2mR and 2,8mR. Under the same conditions, the scattered radiation at the distance of 1 meter from the phantom were 84 μR at the front side, 11μR at the back side, 18μR at the right side and 72μR at the left side. 3. Under the same conditions, the dose showed higher value by about 5% in the presence of object(phantom) than in the case of absence.

  • PDF

Improvement of Motion Accuracy Using Active Controlled Capillary in Hydrostatic Table (능동제어모세관을 이용한 유정압테이블의 운동정도 향상)

  • Park, C.H.;Song, Y.C.;Lee, H.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.12
    • /
    • pp.114-120
    • /
    • 1997
  • For compensating the error motion of hydrostatic tables, we have introduced a way that the clearance of table is controlled corresponding to the amount of eror with the actively controlled variable capillary, named as ACC. In previous paper, through the basic test, it was confirmed that by the use of ACC, the error motion within 2.7$\mu$ m of a hydrostatic table could be compensated with the resolution of 27nm, 1/100 contollable range, and with the frequency bandwidth of 5.5Hz, structurally. In this paper, we performed practical compensation of the linear and angular motion error of hydrostatic table using ACC. For improving the compensated motion accuracy, iterative control method is put into the control system. The experimental results show that by the simultaneous compensation of error, the linear and angular motion error are improved upto 0.25$\mu$ m and 0.4arcsec, which are about 1/10 and 1/3 of the non-compensated motion errors respectively.

  • PDF

The Effect of Molecular Weight and the Linear Velocity of Drum Surface on the Properties of Electrospun Poly(ethylene terephthalate) Nonwovens

  • Kim, Kwan-Woo;Lee, Keun-Hyung;Khil, Myung-Seob;Ho, Yo-Seung;Kim, Hak-Yong
    • Fibers and Polymers
    • /
    • v.5 no.2
    • /
    • pp.122-127
    • /
    • 2004
  • In this study, we evaluated the effect of the molecular weight of the polymer on electrospun poly(ethylene terephthalate) (PET) nonwovens, and their mechanical properties as a function of the linear velocity of drum surface. Polymer solutions and electrospun PET nonwovens were characterized by means of viscometer, tensiometer, scanning electron microscope(SEM), wide angle X-ray diffraction measurement (WAXD) and universal testing machine (UTM). By keeping the uniform solution viscosity, regardless of molecular weight differences, electrospun PET nonwovens with similar average diameter could be obtained. In addition, the mechanical properties of the electrospun PET nonwovens were strongly dependent on the linear velocity of drum surface. From the results of the WAXD scan, it was found that the polymer took on a particular molecular orientation when the linear velocity of drum surface was increased. The peaks became more definite and apparent, evolving from an amorphous pattern at 0 m/min to peaks and signifying the presence of crystallinity at 45 m/min.

A Study on a Ultrasonic Vibration Assisted Grinding of Alumina Ceramic with Diamond Grinding Tool (초음파 진동을 하는 다이아몬드 연삭공구의 알루미나 세라믹 연삭 가공에 관한 연구)

  • Choi, Young-Jae;Song, Ki-Hyeong;Park, Kyung-Hee;Hong, Yun-Hyuck;Kim, Kyeong-Tae;Lee, Seok-Woo;Choi, Hon-Zong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.1
    • /
    • pp.13-19
    • /
    • 2012
  • In this study, ultrasonic vibration tool designed and made by using FEM analysis. And machining test was carried out in various machining conditions using ultrasonic vibration capable CNC machine. For work material, alumina ceramic ($Al_2O_3$) was used while for tool material diamond electroplated grinding wheel was used. To evaluate ultrasonic vibration effect, grinding test was performed with and without ultrasonic vibration in same machining condition. In ultrasonic mode, ultrasonic vibration of 20kHz was generated by HSK 63 ultrasonic actuator. The two grinding speeds, 1.67m/s and 3.35m/s, were applied. On the other hand, grinding forces were measured by KISTLER dynamometer.

The Change of Serum Calcium Level during Last Decade in Kangwondo, Korea (최근 10년간 강원도내 소아의 혈중 칼슘농도의 변화)

  • Chun Ko-Un;Shim Jun-Yong;Lee Jae-Seung;Kim Pyung-Kil;NamGoong Mee-Kyung
    • Childhood Kidney Diseases
    • /
    • v.6 no.2
    • /
    • pp.188-197
    • /
    • 2002
  • Purpose : Nowadays, drinks, foods and snacks have frequently been intensified with calcium and the insights into the importance of calcium-intake in general has developed in Korea. In this decade, we found the numbers of children who was visited to our hospital for evaluation of hematuria defined with hypercalciuria were increased. So we tried to compare the mean levels of serum calcium, alkaline phosphate, sodium, potassium, chloride, BUN, creatinine, bicarbonate and urinary pH who visited our hospital in 1991, 1992 with in 2000, 2001. Materials and methods : Between January 1991 to December 1992, and between January 2000 to December 2001, each 366 children and 488 children, aged 1 month to 15 years, who presented in our hospital for tonsilectomy and adenoidectomy or for inguinal herniorrhaphy were enrolled in the study, The children in the study were checked the level of serum calcium, alkaline phosphate, sodium, potassium, chloride, BUN, creatinine, bicarbonate and urinary pH with the machine which was corrected the similar levels of practical chemical levels in serum. We compared each mean levels in 1991s' group with in 2001s' group totally and separately through the age and sex. We used t-test to analysis data. Results : The levels of serum calcium, alkaline phosphate, creatinine, sodium, potassium, and urinary pH of 2001s' group were significantly higher than the levels of 1991s' group(P<0.05). The each level was $9.91{\pm}0.50\;mg/dL,\;248.58{\pm}94.98\;U/L,\;0.61{\pm}0.14\;mg/dL,\;138.64{\pm}2.22\;mM/L,\;4.35{\pm}0.40\;mM/L,\;6.18{\pm}0.86$ in 2001s' and $9.13{\pm}0.68;mg/dL,\;198.26{\pm}79.34\;U/L,\;0.433{\pm}0.18\;mg/dL,\;137.86{\pm}2.67\;mM/L,\;4.22{\pm}0.36\;mM/L,\;5.83{\pm}0.95$ in 1991s'. And the levels of serum bicarbonate, $23.64{\pm}2.57\;mM/L$ in 2001s' was significantly lower than the 1991s', $24.60{\pm}2.23\;mM/L$(P<0.05). The similar results were detected each age and sex group. Conclusion : The levels of serum calcium increase in this decade. The results will be used as a basic data for the national health plan in the years to come.

  • PDF

Effect of Continuous Cultivation Years on Soil Properties, Weed Occurrence, and Rice Yield in No-tillage Machine Transplanting and Direct Dry-seeding Culture of Rice (벼 무경운 기계이앙 및 건답직파 연속재배년수가 토양특성, 잡초발생 및 벼 생육에 미치는 영향)

  • Park, Hong-Kyu;Kim, Sang-Su;Choi, Won-Yong;Lee, Ki-Sang;Lee, Jae-Kil
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47 no.3
    • /
    • pp.167-173
    • /
    • 2002
  • This experiment was conducted to figure out the change of soil physical properties, rice growth and yield with the years of continuous cultivation in direct dry-seeding and no-tillage machine transplanting. Experiments were conducted at NHAES(National Honam Agricultural Experiment Station, RDA, Iksan, Cheon Buk Province, South Korea) with a rice variety "Dongjinbyeo" from 1995 to 2000. In no-tillage machine transplanting cultivation, organic matter in soil was higher than that on direct dry-seeding and was significantly high in topsoil. Problematic weed species were E. crus-galli B., A. keisak H., and L. japonica M. Plant height and tiller number m-2 were higher in common-tillage during the total growth duration. The highest weedy rice occurrence of 27.5% was observed in live years' continuous direct dry-seeding and followed by 6.2%, in four years', and 3.7%, in three years'. The highest yield reduction of 38% was observed in five years' continuous direct dry-seeding. The reduction may resulted from the competition between weedy rice and cultivated rice.