• Title/Summary/Keyword: Machine-to-machine (M2M)

Search Result 1,081, Processing Time 0.038 seconds

Isokinetic Test of the Extensors and Flexors in Total Knee Replacement Patients (슬관절 전치환술 환자의 슬관절 신전근 및 굴곡근에 대한 등속성운동검사)

  • Lee, Keun-Heui;Lee, Hyun-Ok;Lee, In-Sil;Seo, Hyun-Kyu;Kim, Seung-Joon;Bae, Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.3
    • /
    • pp.585-596
    • /
    • 2001
  • The twenty one individuals with total knee replacement who were admitted to Kang-Dong Hospital for comprehensive physical therapy were studied in order to demonstrate the effectiveness of an isokinetic test program using the Cybex 6000 machine. The subjects were divided into three groups with the isometric exercise group receiving isometric exercise, the isokinetic eccentric exercise group, and isokinetic concentric exercise group receivind isokinetic exercise(eccentric, concentric) to knee flexors and extensors muscles for a six weeks' period using the Cybex 6000. The results are follow: 1. The extensors were increased significantly at all groups after 6 weeks training(p<.05). The flexors were increased significantly at isokinetic eccentric and isokinetic concentric group but no significantly differences at isometric group(p>.05) 2. At the effect of extensors and flexors after 6 weeks training. higher to 30$^{\circ}$ /sec of isokinetic concentric exercise, lower to 120$^{\circ}$ /sec of isometric exercise. 3. The peak torque was more increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups. 4. The total work was more increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups. 5. The ratio of peak torque to body weight were more increased significantly in the flexors and extensors of the isikinetic conccentric exercise among three groups. 6. The average power was more increased significantly in the flexors and extensors of the isikinetic conccentric exercise among three groups. 7. The average R.O.M in the pre-exercise and post-exercise was not different significantly in all three groups. According to the above results, In the muscle strength recovery for total knee replacement patients, isokinetic concentric exercise group was significantly greater than the isokinetic eccentric and isometric exercise groups after a six weeks training.

  • PDF

Quantitative Analysis of Tooth Mineral Content by High Resolution Micro-computed Tomography

  • Song, Dae-Sung;Kim, Jung-Woo;Hwang, Hee-Su;Oh, Sin-Hye;Song, Ju Han;Kim, Il-Shin;Hwang, Yun-Chan;Koh, Jeong-Tae
    • International Journal of Oral Biology
    • /
    • v.42 no.4
    • /
    • pp.155-161
    • /
    • 2017
  • Teeth and bones are highly mineralized tissues containing inorganic minerals such as calcium phosphate, and a growing number of evidences show that their mineral content is associated with many diseases. Although the quantification of mineral contents by micro-computed tomography(micro- CT) has been used in diagnosis and evaluation for treating bone diseases, its application for teeth diseases has not been well established. In this study, we attempted to estimate a usefulness of a high-resolution micro-CT in analysis of human teeth. The teeth were scanned by using the Skyscan 1172 micro-CT. In order to measure tooth mineral content, beam hardening effect of the machine was corrected with a radiopaque iodine-containing substance, iodoacetamide. Under the maximum resolution of $6.6{\mu}m$, X-ray densities in teeth and hydroxyapatite standards were obtained with Hounsfield unit (HU), and they were then converted to an absolute mineral concentration by a CT Analyzer software. In enamel layer of cusp area, the mean mineral concentration was about $2.14mg/mm^3$ and there was a constant mineral concentration gradient from the enamel surface to the dentinoenamel junction. In the dentin of middle 1/3 of tooth, the mean mineral concentration was approximately $1.27mg/mm^3$ and there was a constant mineral concentration gradient from the outer of root to the pulp side, ranging from 1.3 to $1.06mg/mm^3$. In decay region of dentin, the mineral content was gradually decreased from the intact inner side to the decayed surface. These results suggest that high-resolution micro-CT can be as a useful tool for non-invasive measurement of mineral concentration in teeth.

Modeling the Competition Effect of Sagittaria trifolia and Monochoria vaginalis Weed Density on Rice in Transplanted Rice Cultivation (벼 기계이앙재배에서 벼와 물달개비 및 벗풀 경합에 따른 예측모델)

  • Moon, Byeong-Chul;Kwon, Oh-Do;Cho, Seung-Hyun;Lee, Sun-Gye;Won, Jong-Gun;Lee, In-Yong;Park, Jae-Eup;Kim, Do-Soon
    • Korean Journal of Weed Science
    • /
    • v.32 no.3
    • /
    • pp.188-194
    • /
    • 2012
  • Field experiments were conducted to investigate the competition relationships of main paddy weeds with transplanted rice grown in paddy conditions. Data were used to predict crop yield as a function of weed density using a rectangular hyperbola model and determine weed economic threshold (ET) levels. The rectangular hyperbola (equation 2) was fitted to rice yield to estimate weed-free rice yield ($Y_o$) and weed competitivity (${\beta}$). Its competitivity for M. vaginalis was 0.0007445, 0.0005713, 0.000988 and 0.0008846 in Daejeon, Suwon, Iksan and Naju, respectively. The competitivity at harvest represented by parameter ${\beta}$ ranged from 0.001611 in Naju to 0.002437 in Iksan for S. trifolia. The ET levels of main paddy weeds in machine transplanted rice cultivation were well estimated based on the herbicides applied and its application cost. Therefore, our results can be used to support decision-making on herbicide application for weed management in transplanted rice cultivation.

Polishing characteristics of polyetherketoneketone on Candida albicans adhesion (Polyetherketoneketone의 연마 특성이 Candida albicans의 부착에 미치는 영향)

  • Kim, Hyunyoung;Lee, Jonghyuk;Lee, Sung-Hoon;Baek, Dongheon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.207-216
    • /
    • 2020
  • Purpose: To compare the polishing characteristics and their influence on Candida albicans adhesion to the recently introduced polyetherketoneketone (PEKK) and the conventional polymethylmethacrylate (PMMA) denture resin material. Materials and methods: Specimens from PEKK (Group E) and PMMA (Group M) were made in dimensions of 8 mm in diameter and 2 mm in thickness. The specimens were further divided into sub-groups according to the extent of polishing (ER, MR: rough; EP, MP: polished, N = 12 each). The specimens were polished using polishing machine and SiC foil. ER and MR group specimens were polished with 600 grit SiC foil only. EP and MP groups were further polished with 800, 1,000, 1,200 grit SiC foils sequentially. To measure the surface roughness values (Sa) of specimens, atomic force microscope (AFM) was used and scanning electron microscope (SEM) observation under 1,000, and 20,000 magnifications was performed to investigate surface topography. The polished specimens were soaked in C. albicans suspension for 2 hours with shaking to promote adhesion. The attached C. albicans were detached from the surface with 10 times of pipetting. The suspension of detached C. albicans was performed by serial dilution to 103 times, and the diluted suspensions were inoculated on Sabouraud dextrose agar plates using spread plate method. After incubating the plate for 48 hours, colony forming unit (CFU)/plate of C. albicans was counted. Statistical analysis was performed using one-way ANOVA and Tukey HSD test to confirm significant difference between the groups (α=.05). Results: Average Sa value was significantly higher in MR group compared to other groups (P<.05), meaning that additional polishing steps reduced surface roughness effectively only in the PMMA specimens. There was no significant difference in Sa values between MP and EP groups. In SEM images, PEKK specimens showed numerous spikes of abraded material protruding from the surface and this phenomenon was more significant in EP group. The mean CFU/plate value was the highest in EP group and this was significant when it was compared to MP group (P<.05) which was the lowest. Conclusion: Polishing PEKK using serial SiC abrasive foil may result in higher adhesion of C. albicans. In clinic, this should be considered carefully.

The Comparison of Image Quality Using Body Contour and Circular Method with L-mode in Myocardial Perfusion SPECT (Tl-201을 이용한 심근관류 SPECT에서 Body contour와 Circular mode의 영상 획득 차이에 따른 영상의 질 비교)

  • Kim, Sung-Hwan;Nam, Ki-Pyo;Ryu, Jae-Kwang;Yoon, Soon-Sang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.3-7
    • /
    • 2012
  • Purpose : In myocardial perfusion SPECT, the type of orbit (circular vs. body contouring) that affect the image quality is still on the debate. Presently in the nuclear medicine field, the body contouring orbit acquisition is widely used to improve the image quality on the myocardial perfusion SPECT. But in case of body contouring acquisition using the vertical method with dual detect machine, there is a tendency of increasing the radius. In this research, we compared body contouring orbit acquisition with circular orbit acquisition, so we suggest ideal method that reduces the radius for improving image quality. Materials and Methods : Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on equally with counts from patient's body. The study was performed under six different conditions. To compare image quality according to the radius, we increased radius sequentially per step during circular orbit acquisition. On the other hand, sensors that protect a collision and reduce the radius automatically were used to acquire image during body contouring orbit acquisition. So we compared FWHM value of apex. In clinical studies, we analyzed the 40 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center in August 2011. To acknowledge the differences according to the radius, we acquired the results two times using circular orbit acquisition and body contouring orbit acquisition. Results : In phantom study, we analyzed that increase of radius resulted in changes of FWHM value. It was 5.41, 6.24, 6.33, 6.42, 6.93 mm. On the other hand, using the body contouring orbit acquisition, FWHM value was 6.23 mm. In clinical study, difference of average radius between two methods was 2.5 cm (circular orbit acquisition was more close to patients). Conclusion : Through the experiments using Anthropomorphic torso phantom and patients data, we found that FWHM value of circular orbit acquisition was lower than body contouring orbit acquisition. As a result, if the difference of average radius exists approximately 3 cm, circular orbit type acquisition is better than body contouring type acquisition. But clinical investigation is only aimed to average radius, so it needs more investigation in comparison of patient's image.

  • PDF

A study on the shear bond strength between Co-Cr denture base and relining materials (금속의치상과 의치이장재료 간의 결합력에 관한 연구)

  • Lee, Na-Young;Kim, Doo-Yong;Lee, Young-Soo;Park, Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.8-15
    • /
    • 2011
  • Purpose: This study evaluated the bonding strength of direct relining resin to Co-Cr denture base material according to surface treatment and immersion time. Materials and methods: In this study, Co-Cr alloy was used in hexagon shape. Each specimen was cut in flat surface, and sandblasted with $110\;{\mu}m$ $Al_2O_3$ for 1 minute. 54 specimens were divided into 3 groups; group A-control group, group B-applied with surface primer A, group C-applied with surface primer B. Self curing direct resin was used for this study. Each group was subdivided into another 3 groups according to the immersion time. After the wetting storage, shear bond strength of the specimens were measured with universal testing machine. The data were analyzed using two-way analysis of variance and Tukey post hoc method. Results: In experiment of sandblasting specimens, surface roughness of the alloy was the highest after 1 minute sandblasting. In experiment of testing shear bond strength, bonding strength was lowered on group B, C, A. There were significant differences between 3 groups. According to period, Bonding strength was the highest on 0 week storage group, and the weakest on 2 week storage group. But there were no significant differences between 3 periods. According to group and period, bonding strength of all group were lowered according to immersion time but there were no significant differences on group B and group C, but there was significant difference according to immersion time on group A. Conclusion: It is useful to sandblast and adopt metal primers when relining Co-Cr metal base dentures in chair-side.

A Study for Real-Time Information Service (실시간 교통정보 제공에 관한 연구)

  • 김수희
    • Proceedings of the KOR-KST Conference
    • /
    • 1998.10a
    • /
    • pp.151-160
    • /
    • 1998
  • 실시간 교통정보 처리과정은 현장설비로부터 수집되는 각종 교통상황자료를 분석/처리하여 소통상황, 주행속도, 통행시간 등의 교통상황을 단기 예측하는 과정으로서 이는 주행안내시스템의 핵심요소기술이다. 주행안내 시스템 개발의 필요성은 선진국을 중심으로 제기되어 왔으며, 주행안내시스템은 각국 정부의 강력한 지원정책을 바탕으로 연구개발 단계를 거쳐 시범운영의 단계에 있다. 국내에서도 교통정체의 해소와 안전주행의 연구개발 단계를 거쳐 시범운영의 단계에 있다. 국내에서도 교통정체의 해소와 안전주행의 여건마련을 위하여 교통정보를·처리·제공하는 기술의 개발이 활발하게 진행되고 있다. 그러나 국내 기술수준을 보면 전자통신기술을 바탕으로 교통정보의 수집과 제공에 관한 연구는 어느 정도 진행되고 있으나 운전자가 필요로 하는 교통정보의 분석과 처리에 관한 연구는 매우 저조한 실정이다. 본 연구의 목적은 다양한 시스템에서 수집되는 자료를 종합적으로 처리, 저장,관리하고 이의 분석결과를 제공하는 교통정보센터의 프로토타입(Prototype)을 설정하는 것이다. 이러한 목표를 수행하기 위해서 요구되는 교통정보실험실의 기능은 수집된 교통자료의 신뢰성 분석, 교통정보의 종합적인 처리·저장·관리, 그리고 교통정보의 제공은 구분할 수 있다. 따라서, 현재 교통정보실험실에서 운영중인 정보의 형태를 제시하며, 이들 정보의 신뢰성을 실측자료와 비교한 실험적 결과를 예시한다. 또한, 개별 정보이용자에게 실시간 교통정보를 제공하기 위한 통신기술의 검토가 이루어진다. 차내 이용자에게 정보를 실시간으로 제공하기 위해서는 궁극적으로 무선통신기술의 응용이 필요하며, 정보이용자에게 다양한 정보를 제공하기 위해서 인터넷 통신과 연계시키는 것이 합리적으로 판단된다. 결론 부분에서는 교통정보실험실의 기능을 강화시키기 위한 향후의 연구과제를 제시한다.Si결정의 크기를 비교하였을 때 45$\mu\textrm{m}$ 이하의 분말을 섞어 압출하였을 때 가장 작은 초정 Si입자 크기를 얻음 을 볼 수 있었다. 주의 Fairfax County에 소재한 주간 고속도로 66번(I-66)과 인접 교통망의 교통자료를 사용하여 각종 돌발교통 혼잡 상황을 전제로 한 Traffic Simulation과 정보제공시나\리오를 INTEGRATION Model을 이용해 실행하였다. 그 결과 적응형 알고리즘이 개개인의 최단시간 경로를 제공하는 사용자 평형 경로안내전략에 비해 교통혼잡도와 정체시간의 체류정도에 따라 3%에서 10%까지 전체통행시간을 절약할 수 있다는 결론을 얻었다.출발참, 구성대외개방선면축심, 실현국제항선적함접화국내항반적전항, 형성다축심복사식항선망; 가강기장건설, 개피포동제이국제기장건설, 괄응포동개발경제발전적수요. 부화개시일은 각 5월 26일과 5월 22일이었다. 11. 6월 중순에 애벌레를 대상으로 처리한 Phenthoate EC가 96.38%의 방제가로 약효가 가장 우수하였고 3월중순 및 4월중순 월동후 암컷을 대상으로 처리한 Machine oil, Phenthoate EC 및 Trichlorfon WP는 비교적 약효가 낮았다.>$^{\circ}$E/$\leq$30$^{\circ}$NW 단열군이 연구지역 내에서 지하수 유동성이 가장 높은 단열군으로 추정된다. 이러한 사실은 3개 시추공을 대상으로 실시한 시추공 내 물리검층과 정압주입시험에서도 확인된다.. It was resulted from increase of weight of single cocoon. "Manta"2.5ppm produced 22.2kg of cocoon. It is equal to 9% increase in index, as com

  • PDF

BONDING OF RESIN INLAY TO GLASS-IONOMER BASE WITH VARIOUS TREATMENTS ON INLAY SURFACE (내표면 처리에 따른 레진 인레이와 글래스아이오노머 베이스간의 접착)

  • Jang, Byung-Sung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.399-406
    • /
    • 2000
  • The effect of inlay surface treatment on bonding was investigated when resin inlay was bonded to resin-modified glass-ionomer base with resin cement. For the preparation of glass-ionomer base, resin-modified glass-ionomer cement (Fuji II LC, GC Co., Japan) was filled in class I cavities of 7mm in diameter and 2mm in depth made in plastic molds. Eighty eight resin inlay specimens were made with Charisma$^{(R)}$ (Kulzer, Germany) and then randomly assigned to the four different surface treatment conditions: Group I, $50{\mu}m$ aluminium oxide sandblasting and silane treatment ; Group II, silane treatment alone ; Group III, sandblasting alone, and Group IV (control), no surface treatment. After a dentin bonding agent with primer (One-Step$^{TM}$, Bisco Inc., IL., U.S.A.) was applied to bonding surface of resin inlay and base, resin inlay were cemented to glass-ionomer base with a resin cement (Choice$^{TM}$, Bisco Inc., IL., U.S.A.). Shear bond strengths of each specimens were measured using Instron universal testing machine (4202 Instron, lnstron Co., U.S.A.) and fractured surfaces were examined under the stereoscope. Statistical analysis was done with one-way ANOVA and Dunkan's multiple range test. The results were as follows: 1. Sandblasting and silane treatment provided the greatest bond strength(10.56${\pm}$1.95 MPa), and showed a significantly greater bond strength than sandblasting alone or no treatment (p<0.05). 2. Silane treatment provided a significantly greater bond strength(9.77${\pm}$2.04 MPa) than sandblasting alone or no treatment (p<0.05). However, there was no significant difference in bond strength between sandblasting treatment and silane one (p>0.05). 3. Sandblasting alone provided no significant difference in bond strength from no treatment (p>0.05). 4. Stereoscopic examination of fractured surface showed that sandblasting and silane treatment or silane treatment alone had more cohesive failure mode than adhesive failure mode. 5. In relationship between shear bond strength and failure mode, cohesive failure occurred more frequently as bond strength increased.

  • PDF

Synthesis of Aliphatic Ester-Carbonate Copolymer (지방족 에스터-카보네이트 공중합체의 합성)

  • Kim, Dong-Kook;Kim, Ki-Seab;Chang, Young-Wook
    • Applied Chemistry for Engineering
    • /
    • v.7 no.5
    • /
    • pp.970-976
    • /
    • 1996
  • An ester-carbonate copolymer was synthesized, in which carbonate was inserted into a biodegradable aliphatic polyester, poly(butylene succinate) (PBS), to modify its mechanical properties. The synthesis was carried out by condensation reactions in two steps. In the first step, oligo(butylene succinate) was prepared by the reaction of succinic acid with 1,4-butanediol (BD). In the second step, it was reacted with oligohexamethylenecarbonate diol (OHMCG) to prepare the ester-carbonate copolymer. Titanium(IV) isopropoxide (TIP) was used as a catalyst for the reaction. The structure of the copolymer was confirmed by FT-IR and $^1H$-NMR and the thermal behavior and mechanical properties were investigated by differential scanning calorimetry (DSC) and universal testing machine (UTM), respectively. It was found that optimum amount of the catalyst for the formation of high molecular weight copolymer was 1wt% for succinic acid. When the BD:OHMCG is in the range 149:1~249:1, the copolymer with high viscosity was obtained. As the OHMCG content was increased, melting temperature ($T_m$) of the copolymer was decreased. When BD:OHMCG is 149:1, the copolymer showed a increase in ultimate strain by two times and the slight decrease in modulus compared to those of PBS.

  • PDF

Analysis on the Stress of Hydraulic Cylinder for Large Vessel by Boundary Element Method (대형선박용 유압실린더에서 경제요소법을 이용한 응력해석)

  • 김옥삼
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.4
    • /
    • pp.423-434
    • /
    • 1995
  • It was used boundary element method(BEM) and analysed axisymmetric problem to solve hydraulic cylinder for large vessel acting uniform internal pressure(25N/m super(2)) within elastic limit. This paper was utilized the carbon steel tubes for machine structural purposed model, inner radius was 150mm and outer radius was 250mm, axial length was semi-infinite and the isoparametric element was used. The important results obtained in this study were summarized as follows. Radial, tangential and shearing stress occured the maximum stresses(48, -20 and 34MPa) at the inner radius and the minimum stresses(32, -4 and 18MPa) at the outer radius of the hydraulic cylinder for large vessel. But negative signs have meaning compressive stress and stress diminution ratio was about 0.15MPa/mm. The use of isoparametric element raised accuracy and the increment of input data lessened the error in internal point but computer run-time was increased. The double node was improved the internal solutions to settle discontinuity at corner and the double exponential formula lessened error of stress value at boundary neighborhood. And then coincidence between the analytical and exact results is found to be fairly good, showing that the proposed analytical by BEM is reliable.

  • PDF