• Title/Summary/Keyword: Machine System

Search Result 8,774, Processing Time 0.042 seconds

Development of Music Classification of Light and Shade using VCM and Beat Tracking (VCM과 Beat Tracking을 이용한 음악의 명암 분류 기법 개발)

  • Park, Seung-Min;Park, Jun-Heong;Lee, Young-Hwan;Ko, Kwang-Eun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.6
    • /
    • pp.884-889
    • /
    • 2010
  • Recently, a music genre classification has been studied. However, experts use different criteria to classify each of these classifications is difficult to derive accurate results. In addition, when the emergence of a new genre of music genre is a newly re-defined. Music as a genre rather than to separate search should be classified as emotional words. In this paper, the feelings of people on the basis of brightness and darkness tries to categorize music. The proposed classification system by applying VCM(Variance Considered Machines) is the contrast of the music. In this paper, we are using three kinds of musical characteristics. Based on surveys made throughout the learning, based on musical attributes(beat, timbre, note) was used to study in the VCM. VCM is classified by the trained compared with the results of the survey were analyzed. Note extraction using the MATLAB, sampled at regular intervals to share music via the FFT frequency analysis by the sector average is defined as representing the element extracted note by quantifying the height of the entire distribution was identified. Cumulative frequency distribution in the entire frequency rage, using the difference in Timbre and were quantified. VCM applied to these three characteristics with the experimental results by comparing the survey results to see the contrast of the music with a probability of 95.4% confirmed that the two separate.

Study on the Maintenance Interval Decisions for Life expectancy in Railway Turnout clearance Detector (철도 분기기 밀착검지기 Life expectancy의 유지보수 주기 결정에 관한 연구)

  • Jang, ByeongMok;Lee, Jongwoo
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.4
    • /
    • pp.491-499
    • /
    • 2017
  • Railway turnout systems are one of the most important systems in a railway and abnormal turnout systems can cause serious accidents. To detect an abnormal state of a turnout, turnout clearance detectors are widely used. These devices consider a failure of a turnout clearance detectors to be a failure of the turnout system, that could hinder train operations. Analysis of turnout clearance detector failures is very important to ensure normal train operation. We categorized failures of detectors into four groups to identify failure characteristics of the 140 detectors, which are composed of main line detectors (A), side tracks (B), detectors that are in operation more than 80 times a day (C) and detectors that are in operation fewer than 10 times per day. Failures of detectors have mainly been caused in the control part, in the cables and sensors; failures are classified into four groups (A, B, C and D). We have tried to find failure density distributions for each type of failures, inferring the parameter distributions a priori. Finally, using the Bayesian inference we proposed a maintenance time for control parts through the mean time of the detector, life and the life expectancy.

The Philosophy of Martin Buber(I and Thou) and Nursing Philosophy (마르틴 부버의 사상(나와 너)과 간호철학)

  • Lee, Myoung-Suk;Han, Sung-Suk
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.2
    • /
    • pp.95-107
    • /
    • 1997
  • For nursing as a science to establish a unique system of knowledge, nursing researchers should include the philosophical activities such as establish of nursing philosophy. For establish of philosophy nursing, the nature and realms and essential characteristics of nursing science should be made clear at first. The purpose of this study identify alienation and the situation of happen to alienation and Martin Buber Philosophy(I and Thou). Understanding of this concept should enlighten nurses to interaction and relationship problems between patients and nurse and thus lead to further toward enhancing these interaction and relationship. The alienation was serious problem in present society which was cultural, political, economical, mechanical, religious classified. The overcome of alienation in nursing situation was caring and interpersonal relationship based on Martin Buber philosophy. The essential philosophy of Martin Buber was "I and Thou" relationship. I and Thou relationship are consist of five characteristics ; 1)mutuality 2)directness 3)presentness 4)intensity 5)ineffability As health care technology becomes more sophisticated, there is a tendency to rely on monitors and machines to assess the patient's status. Therefore focus on the functioning and care of machine can result in less meaningful communication with patients. This study points to the need for health professional and patient relationship based on Martin Buber philosophy(I and Thou). This relationship may suggest that professional shoud have sincerity, concerning, respect and warm emotional toward their patients. Ultimately this study provide the basic information to contribute understanding of "I and Thou" relationship and nursing philosophy development in nursing education.

  • PDF

Eligibility Analysis of Land on a Reforestation CDM Project in Goseong District, South Korea (청정개발체제하 재 조림 사업의 토지적격성에 대한 사례 분석 -고성군 재조림 사업을 중심으로-)

  • Guishan, Cui;Kwon, Tae-Hyub;Lee, Woo-Kyun;Kwak, Hanbin;Nam, Kijun;Song, Yongho;Hangnan, Yu
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.2
    • /
    • pp.216-222
    • /
    • 2013
  • For reducing greenhouse gases, many countries carried out a series of activities not only at home but abroad. Particularly, after the release of the Kyoto Protocol, either nation or companies' participation was intensified, due to endow to responsibility of emission limits. This study focused on reforestation CDM work in Goseong Gun based on clean development system. Obstacle factors of land eligibility could be distinguished to three periods: before December 31th 1989, present and future. The obstacle before December 31th 1989 was that land cover of study area hardly illustrated by Landsat image, due to the low resolution, which were confirmed by a document of Grassland Composition Permission instead. The problem of current land eligibility is that the area of trees presence are difficult to be determined as forest or not. The boundary of forest in strata was identified, using 3-Dimensional Cartography Machine and aerial photograph. Land eligibility would still have obstacle whether the study area with trees presence has potentiality to be forest in the future at situation in absence of reforestation project. This was resolved by prediction of tree growth using stem analysis during execution of the project at study area.

Evaluation of the Radiopacity of Contemporary Luting Cements by Digital Radiography (디지털방사선촬영술을 이용한 합착용 시멘트의 방사선불투과성 평가)

  • An, Seo-Young;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.377-383
    • /
    • 2013
  • This study examined the radiopacity of eight contemporary luting cements by direct digital radiography. Five disc-shaped specimens ($5mm{\times}1mm$) were prepared for each material tested (BisCem, Clearfil SA Luting, Duolink, Maxcem Elite, Multilink Speed, Panavia F 2.0, RelyX Unicem Clicker, V-link). The specimens were radiographed using a Kodak CS 7600 image plate (Carestream Health, Inc., Rochester, NY, USA) and an aluminum step wedge with a range of thicknesses (1.5 to 16.5 mm in 1.5 mm increments) and a 1 mm tooth used as a reference. A dental X-ray machine Kodak 2200 Intraoral X-ray System (Carestream Health, Inc., Rochester, NY, USA), operating at 70 kVp, 4 mA, 0.156 s and a source-to-sample distance of 30 cm, was used. According to international standards, the radiopacity of the specimens was compared with that of an aluminum step wedge using NIH ImageJ software (available at http://rsb.info.nih.gov/ij/).The data was analyzed by ANOVA and a Tukey's post hoc test. Maxcem Elite (5.66) showed the highest radiopacity of all materials, followed in order by Multilink Speed (3.87) and V-link (2.83). The radiopacity of Clearfil SA Luting (1.35), BisCem (1.33), Panavia F 2.0 (1.29) and Duolink (1.10) were between enamel (1.79) and dentin (0.19). RelyX Unicem Clicker (0.71) showed the lowest radiopacity, which was higher than that of dentin. All materials showed a radiopacity above the minimum recommended by the International Organization for Standardization and the American National Standards/American Dental Association with the exception of RelyX Unicem Clicker.

A STUDY ON THE EVALUATION OF POLYMERIZATION SHRINKAGE OF COMPOSITE AND COMPOMER USING STRAIN GAUGE METHOD (스트레인 게이지법을 이용한 복합레진과 컴포머의 중합수축 평가에 관한 연구)

  • Kim, Yeun-Chul;Kim, Jong-Soo;Kwon, Soon-Won;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.19-29
    • /
    • 2002
  • The purpose of this study was to compare the polymerization shrinkage and the compressive strength of composite and compomer cured with two different light sources ; conventional halogen-light curing unit and recently-developed plasma arc curing unit. The 'strain gauge method' was used for determination of polymerization shrinkage and the compressive strength was measured by universal testing machine. The results of the present study can be summarized as follows: 1. Filling materials in polyethylene molds showed the initial expansion in the early phase of polymerization. This was followed by the rapid contraction in volume during the first 60 seconds and gradually diminished as curing process continued. 2. The polymerization shrinkage in tooth samples was generally lower than in the mold samples. 3. The generally lower amount of linear polymerization shrinkage was observed in compomer and plasma arc curing unit group when compared to composite and conventional curing unit. 4. The higher compressive strength values was found in composite groups regardless curing methods. The results of this study strongly support the application of plasma arc system and fluoride-containing compomer in the field of clinical pediatric dentistry claiming its effectiveness in curing the esthetic dental materials and the anticariogenic capacity.

  • PDF

Empirical Research on Search model of Web Service Repository (웹서비스 저장소의 검색기법에 관한 실증적 연구)

  • Hwang, You-Sub
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.4
    • /
    • pp.173-193
    • /
    • 2010
  • The World Wide Web is transitioning from being a mere collection of documents that contain useful information toward providing a collection of services that perform useful tasks. The emerging Web service technology has been envisioned as the next technological wave and is expected to play an important role in this recent transformation of the Web. By providing interoperable interface standards for application-to-application communication, Web services can be combined with component-based software development to promote application interaction and integration within and across enterprises. To make Web services for service-oriented computing operational, it is important that Web services repositories not only be well-structured but also provide efficient tools for an environment supporting reusable software components for both service providers and consumers. As the potential of Web services for service-oriented computing is becoming widely recognized, the demand for an integrated framework that facilitates service discovery and publishing is concomitantly growing. In our research, we propose a framework that facilitates Web service discovery and publishing by combining clustering techniques and leveraging the semantics of the XML-based service specification in WSDL files. We believe that this is one of the first attempts at applying unsupervised artificial neural network-based machine-learning techniques in the Web service domain. We have developed a Web service discovery tool based on the proposed approach using an unsupervised artificial neural network and empirically evaluated the proposed approach and tool using real Web service descriptions drawn from operational Web services repositories. We believe that both service providers and consumers in a service-oriented computing environment can benefit from our Web service discovery approach.

Detecting Peripheral Nerves in the Elbow using Three-Dimensional Diffusion-Weighted PSIF Sequences: a Feasibility Pilot Study

  • Na, Domin;Ryu, Jaeil;Hong, Suk-Joo;Hong, Sun Hwa;Yoon, Min A;Ahn, Kyung-Sik;Kang, Chang Ho;Kim, Baek Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.81-87
    • /
    • 2016
  • Purpose: To analyze the feasibility of three-dimensional (3D) diffusion-weighted (DW) PSIF (reversed FISP [fast imaging with steady-state free precession]) sequence in order to evaluate peripheral nerves in the elbow. Materials and Methods: Ten normal, asymptomatic volunteers were enrolled (6 men, 4 women, mean age 27.9 years). The following sequences of magnetic resonance images (MRI) of the elbow were obtained using a 3.0-T machine: 3D DW PSIF, 3D T2 SPACE (sampling perfection with application optimized contrasts using different flip angle evolution) with SPAIR (spectral adiabatic inversion recovery) and 2D T2 TSE (turbo spin echo) with modified Dixon (m-Dixon) sequence. Two observers used a 5-point grading system to analyze the image quality of the ulnar, median, and radial nerves. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of each nerve were measured. We compared 3D DW PSIF images with other sequences using the Wilcoxon-signed rank test and Friedman test. Inter-observer agreement was measured using intraclass correlation coefficient (ICC) analysis. Results: The mean 5-point scores of radial, median, and ulnar nerves in 3D DW PSIF (3.9/4.2/4.5, respectively) were higher than those in 3D T2 SPACE SPAIR (1.9/2.8/2.8) and 2D T2 TSE m-Dixon (1.7/2.8/2.9) sequences (P < 0.05). The mean SNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR, but there was no difference between 3D DW PSIF and 2D T2 TSE m-Dixon in all of the three nerves. The mean CNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR and 2D T2 TSE m-Dixon in the median and ulnar nerves, but no difference among the three sequences in the radial nerve. Conclusion: The three-dimensional DW PSIF sequence may be feasible to evaluate the peripheral nerves around the elbow in MR imaging. However, further optimization of the image quality (SNR, CNR) is required.

A Study on the Retentive Force of Stud Attachments for Implant Overdenture (임플란트 피개의치를 위한 개별유지형 어태치먼트의 유지력에 관한 연구)

  • Song, Eun-Ju;Bae, Eun-Bin;Choi, Jae-Won;Bae, Ji-Hyeon;Kim, Ji-Young;Lee, So-Hyoun
    • Journal of dental hygiene science
    • /
    • v.16 no.1
    • /
    • pp.93-100
    • /
    • 2016
  • The purpose of this study was to compare the changes of retentive force in different stud attachment systems for implant retained overdenture. Two commercially available attachments with different retentive forces were investigated: Kerator (pink, blue, red) and O-ring (orange, red). Two implant fixtures were vertically embedded in base mountings. Five pairs of each attachment were evaluated. A universal testing machine was used to evaluate the retentive force of two attachments during wear simulation. Surface characteristics of each attachment system were evaluated with scanning electron microscopy. Five pairs of each attachment were evaluated. Kerator pink showed the highest initial retention. After 2,500 cycles of wear-simulation, Kerator pink noted the largest decrease in retention. According to results of surface analysis, Worn surfaces were obtained in matrices and patrices. Heavy wears were observed in matrices. After 2 year-wear simulation, most attachments exhibited retention loss. Attachments using different kind of material exhibited dissimilar surface alterations.

A SHEAR BOND STRENGTH OF RESIN CEMENT BONDED TO HUMAN UNCUT ENAMEL, CUT ENAMEL, AND DENTIN IN VITRO

  • Lee Jong-Yeop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.319-324
    • /
    • 2003
  • Statement of problem. Adhesives in dentistry playa major role in the success of restorative treatments. In the treatment of all ceramic restoration it is needed to find the adequate bond strength between enamel and dentin. Purpose. The purpose of this study was to evaluate shear bond strength of resin cement bonded to extracted human uncut enamel, cut enamel, and dentin in vitro. Material and methods. Ten freshly extracted anterior teeth without any previous restorative treatments were chosen. The extracted teeth were embedded in PMMA cold acrylic in the shape of a cylinder, 25 mm in diameter by 25 mm in height. The bonding system used was as follow: Uni-Etch (32% phosphoric acid), One-Step adhesive, Duolink resin cement. The specimens were acid etched and rinsed with water. Two layers of One-Step adhesive were coated with a disposable brush on the uncut enamel. VIP curing light at $500mV/cm^2$ was used to cure the adhesive. For cut enamel shear bond test, the specimen used for uncut enamel was further reduced approximately $0.3{\sim}0.5mm$ using a laminate preparation diamond bur (0.3 mm in depth). The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit SiC paper and cleaned with distilled water. The bonding procedure on the cut enamel was same as uncut enamel bonding procedure. For dentin bonding test, the specimen used for cut enamel was further reduced approximately $0.5mm{\sim}1.0mm$ using a laminate preparation diamond bur (0.5 mm in depth of diamond cutting). The amount of reduction was evaluated with the silicone mold. The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit silicon carbon paper and cleaned in distilled water. The bonding procedure on the dentin was same as uncut enamel bonding procedure. All samples were mounted and secured on the Ultradent shear bond test sample holder, and Ultradent restricted shear bond testing device was used with Universal Instron machine until fracture. Analysis of variance (ANOVA) test was performed comparing the result at P<0.05. Multiple comparison (Tukey) was used to compare each groups. Result. The result showed that the mean value in shear bond strength of resin cement bonded to uncut enamel, cut enamel and dentin were 27.04 Mpa, 30.25 Mpa and 26.39 Mpa with respect. Conclusion. Within the limitation of this study, the mean value of the shear bond strength of cut enamel was higher than those of uncut enamel or dentin. However there existed no statistical differences between three different human dentition substrates due to increased adhesive characteristics.