• Title/Summary/Keyword: M_2\

Search Result 95,297, Processing Time 0.119 seconds

Analysis of the Construction Process Managed by the U.S. Army Corps of Engineers Far East District Using IDEF0 (주한미군공사 수행을 위한 FED(Far East District) 프로세스 분석에 관한 연구)

  • Hwang, Jae-Hong;Ham, Nam-Hyuk;Kim, Je-Hyuck;Kim, Jae-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.1
    • /
    • pp.163-173
    • /
    • 2010
  • A significant number of projects have been managed by US Army Corps of Engineers FED. Today, more information must be provided to the parties involved in the projects by phase than ever before. Specifically, USFK`s construction projects have been managed by FED(Far East District). Recently, however, large US private construction companies have been filling the role previously taken by FED. However, there is few construction managers to implement FED project in Korea. Accordingly, this study analyzes FED projects practices with focus on the construction management actors in order to suggest guideline. This study suggests a model FED construction process(Bid, Contract, Construction, As-Built Phase) by analyzing the existing FED project process using a IDEF0 methodology.

DNA Condensation and Delivery in 293 Cells Using Low Molecular Weight Chitosan/gene Nano-complex (저분자량 키토산/유전자 나노콤플렉스 제조 및 이를 이용한 293 세포로의 전달)

  • Pang, Shi-Won;Jang, Yangsoo;Kim, Jung-Hyun;Kim, Woo-Sik
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.313-317
    • /
    • 2005
  • Synthetic gene carriers such as poly-cationic polymers easily form complexes with plasmid DNA which contains negative charge. Chitosan is a polysaccharide that demonstrates much potential as a gene delivery system. The ability of depolymerized chitosan to condense DNA was determined using electrophoresis. Dynamic laser scattering and scanning electron microscopy were used to examine the size and the morphology of the chitosan/DNA complex. Parameters such as chitosan molecular weight and charge density influenced the complex size and the DNA amount condensed with chitosan. The cell viabilities in the presence of chitosan ranged between 84-108% of the control in all experiments. Gene expression efficacy using chitosan/DNA complex was enhanced in 293 cells relative to that using naked DNA, although it was lower than that using lipofecamine. Transfection efficacy using low molecular weight chitosan (Mw=8,517) was higher than those of the control and the other chitosan (MW=4,078). The low molecular weight chitosan (MW=8,517) with a high charge density (18.32 mV) fulfilled the requirements for a suitable model gene delivery system with respect to the condensing ability of DNA, complex formation, and transfection efficacy.

Preconcentration and Determination of Trace Copper(II) and Lead(II) in Aqueous Solutions by Adsorption on Ca-Alginate Bead (알긴산칼슘 비드 상 흡착에 의한 흔적량 구리(II)와 납(II)의 동시 농축 및 정량)

  • Choi, Jong-Moon;Choi, Sun-Do
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.6
    • /
    • pp.590-598
    • /
    • 2004
  • The preconcentration and determination of trace Cu(II) and Pb(II) on calcium alginate beads in aqueous solution were studied. A calcium alginate beads were prepared by adding an alginic acid to sample solution contained Ca(II). Some following conditions were optimized: the pH of sample solution, amount of alginic acid, and stirring time for effective adsorption; the type and concentration of acid, and sonication time in an ultrasonic vibrator for the perfect de-sorption. A sample solution was prepared with Cu(II) and Pb(II) in DI water. And Ca(II) and ethanol was added into the sample solution. The pH of the final sample solution was controlled with buffer solution. The alginic acid were dispersed in the sample solution by a magnetic stirrer. This mixture was stored in room temperature for 30 min to form a calcium alginate. After the beads were filtered and washed on a membrane filter, the analytes were redissolved from the beads by an ultrasonic vibration of 10 minutes in 1.0M $HNO_3$ solution. The effect of diverse ions on the adsorption of analytes were studied. This procedure was applied for the analysis of two real samples. The recoveries in spiked samples were $90.4{\sim}104.3%$ for analytes.

Planting Design in Green Open Space, Urban Area : Planting Evaluation of Buffer Green Space in Housing Complex (도시지역 녹화공간의 배식기법 : 공동주택단지 완충녹지의 배식)

  • Cho, Woo
    • Korean Journal of Environment and Ecology
    • /
    • v.12 no.1
    • /
    • pp.78-90
    • /
    • 1998
  • An objective of this study was to provide database for the planting disign of buffer green space. Types, planting structure, and effect of vuffer green space were investigated in five housing complexes of newtown of metropolitan area, Korea. Buffer green space in the study sites were constructed as mounding, slope, and plate. The number of species was found 20 tree and sub-tree species(10 evergreen and 20 deciduous species ) and 13 shrub species. These species were planted in one-storyed planting structure and there was no difference with ornamental species in the urban parks. Effect of sound proof by the buffer green space was recognized but sound level in four types among the seven types was observed above standard sound level for housing complex(65dB). Effect of sound proof was especially most effective in the mounding type. It was found that planting density and index of plant crown volume were mot satisfied to the function of buffer green space because of lower density and crown volume than natural vegetation per unit. Based on these results, this study suggested that buffer green space is desirable to be developed in the mounding type over two meters height with multi-layer planting model. In addition, there is needed to consider vegetation structure of natural forest around the developing site.

  • PDF

Selection of Optimum Closed Hydroponic System for Production of Echinacea spp. (Echiacea 속 식물에 적합한 수경재배 시스템 선발)

  • Lee, Hye-Jin;Yoo, Hyung-Joo;Lee, Yong-Hee;Choi, Ki-Young;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.18 no.2
    • /
    • pp.107-111
    • /
    • 2009
  • This experiment was conducted to select optimum hydroponic systems for clean and mass production for shoot and root of Echinacea. E. purpurea and E. angustifolia. were grown at 5 different kinds of hydroponic systems; NFT, modified NFT, DFT, aeroponics, and Ebb & Flow for 150 days. The lowest photosynthetic rate and transpiration rate were in Ebb & Flow system in E. purpurea and E. angustifolia at 120 days after transplanting. The shoot fresh and dry weight were high in aeroponic and DFT system of E. angustifolia and in aeroponic and NFT system of E. purpurea at 150 days after transplanting. The root fresh and dry weight of both species were the highest in aeroponic system and next to modified NFT system. They were increased in NFT and Ebb & Flow system for the root length and in aeroponic system for the number of tillering. The results demonstrate that aeroponic system was the most effective for enhancement shoot and root biomass of Echinacea spp. in hydroponics.

Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI (MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석)

  • Lee H. R.;Han J. Y.;Cho M. H.;Im C. H.;Jung H. K.;Lee S. Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.108-115
    • /
    • 2003
  • Purpose : To evaluate the effect of the gradient switching noise on the ECD source localization with the EEG data recorded during the MRI scan. Materials and Methods : We have fabricated a spherical EEG phantom that emulates a human head on which multiple electrodes are attached. Inside the phantom, electric current dipole(ECD) sources are located to evaluate the source localization error. The EEG phantom was placed in the center of the whole-body 3.0 Tesla MRI magnet, and a sinusoidal current was fed to the ECD sources. With an MRI-compatible EEG measurement system, we recorded the multi channel electric potential signals during gradient echo single-shot EPI scans. To evaluate the effect of the gradient switching noise on the ECD source localization, we controlled the gradient noise level by changing the FOV of the EPI scan. With the measured potential signals, we have performed the ECD source localization. Results : The source localization error depends on the gradient switching noise level and the ECD source position. The gradient switching noise has much bigger negative effects on the source localization than the Gaussian noise. We have found that the ECD source localization works reasonably when the gradient switching noise power is smaller than $10\%$ of the EEG signal power. Conclusion : We think that the results of the present study can be used as a guideline to determine the degree of gradient switching noise suppression in EEG when the EEG data are to be used to enhance the performance of fMRI.

  • PDF

A Propeller Design Method with a New Blade Section : Applied to Container Ships (새로운 날개단면을 이용한 프로펠러 설계법 - 콘테이너선에 응용 -)

  • J.T. Lee;M.C. Kim;J.W. Ahn;S.H. Van;H.C. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.2
    • /
    • pp.40-51
    • /
    • 1991
  • A Propeller design method using the newly developed blade section(KH18), which behaves better cavitation characteristics, is presented. Experimental results for two-dimensional foil sections show that the lift-drag curve and the cavitation-free bucket diagram of the new blade section are wider comparing to those of the existion NACA sections. This characteristic of the new section is particularly important for marine propeller applications since angle of attack variation of the propeller blade operating behind a non-uniform ship's wake is relatively large. A lifting surface theory is used for the design of a propeller with the developed section for a 2700 TEU container ship. Since the most suitable chordwise loading shape is not known a priori, chordwise loading shape is chosen as a design parameter. Five propellers with different chordwise loading shapes and different foil sections are designed and tested in the towing tank and cavitation tunnel at KRISO. It is observed by a series of extensive model tsets that the propeller(KP197) having the chordwise loading shape, which has less leading edge loading at the inner radii and more leading edge loading at the outer radii of 0.7 radius, has higher propulsive efficiency and better cavitation characteristics. The KP197 propeller shows 1% higher efficiency, 30% cavitation volume reduction and 9% reduction of fluctuating pressure level comparing to the propeller with an NACA section. More appreciable efficiency gain for the new blade section propeller would be expected by reduction of expanded blade area considering the better cavitation characteristics of the new blade section.

  • PDF

Efficiency Analysis of Total Logistics Provider (종합물류기업의 경쟁력 분석)

  • Park, Hong-Gyun
    • Journal of Korea Port Economic Association
    • /
    • v.27 no.2
    • /
    • pp.261-273
    • /
    • 2011
  • Mega-corporations are emerging as a result of M&As (mergers and acquisitions) in the logistics industry. The global logistics market has progressed in a continuously competitive manner. Global logistics corporations provide integrated set of services, from production to disposal in order to manage the process efficiently throughout the diverse regions of the world. To advance into an total integrated logistics provider, the corporation must have professional knowledge in logistics and information technology which are necessary to deliver effective integrated logistics solutions. The government has integrated the logistics corporations both horizontally and vertically with the aim to foster logistics corporations possessing global competitiveness. Six years have passed since the implementation of the comprehensive (total) logistics industry certification system in pursuit of making Korea the hub for the Northeast Asian logistics market. This study compares and analyzes the efficiency of nine mega integrated logistics providers by applying the CCR model and BCC model. Each of the nine corporations is subject to certification as integrated logistics corporations. In Korea, nine corporations are certified individually as integrated logistics corporations out of the 31 logistics providers. The analysis showed that the Glovis was the most efficient integrated logistics provider reaching 100% in efficiency and displayed the highest efficiency for six consecutive years from 2005 to 2010. The study also found that the Glovis will be able to maintain 100% in efficiency rate, even though the input are increased over six times as many as those of 2010.

Analysis of Methamphetamine and Amphetamine in Oral Fluid of Eleven Drug Abusers (마약남용자 11명의 타액 중 메스암페타민의 분석)

  • Kim, Eun-Mi;Lee, Ju-Seon;Choi, Hye-Young;Choi, Hwa-Kyung;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.52 no.6
    • /
    • pp.419-425
    • /
    • 2008
  • A qualitative and quantitative analytical method was developed for detection of methamphetamine (MA) and its main metabolite amphetamine (AM) in oral fluid. Oral fluids of eleven drug abusers were provided by Police, specimens were collected by stimulation with a cotton swab treated with 20 mg of citric acid ($Salivette^{(R)}$; Sarstedt, USA). As the preliminary test, oral fluid samples were screened for amphetamines by Fluorescence Polarization Immunoassay (TDxFLx, Abbott Co.). Extraction for MA was performed using solid-phase extraction (SPE) by $RapidTrace^{TM}$ (Zymark, USA) with mixed mode cation exchange cartridge, CLEAN $SCREEN^{(R)}$ (130 mg/3 ml, UCT) after dilution with phosphate buffer. Samples were evaporated and derivatized by pentafluoropropionic acid anhydride (PFPA). Quantitation of MA and AM was performed by gas chromatography-mass spectrometry (GC-MS) using selective ion monitoring (SIM), the quantitation ions were m/z 204 (MA), 208 (MA-$D_5$), 190 (AM) and 194 (AM-$D_5$). The selectivity, linearity of calibration, limit of detection (LOD) and quantification (LOQ) within- and between day precision, accuracy and recoveries were examined as parts of the method validation. All oral fluid samples gave positive results to immunoassay for MA (cut-off level, 50 ng/ml as d-amphetamine). Concentrations of MA and AM by GC-MS in eleven samples were ranged 104.2${\sim}$4603.3 ng/ml and 32.4${\sim}$268.6 ng/ml, respectively. Extracted calibration curves of MA and AM were linear over the two concentration range of 1${\sim}$100 and 50${\sim}$1000 ng/ml with correlation coefficient of above 0.999. LOQ of MA and AM was 1 and 3 ng/ml, respectively. The intraand inter-day run precisions (CV) for MA and AM were less than 10%, and the accuracies (bias) for MA and AM were also less than 10% at the two different concentrations 5 and 100 ng/ml at low calibration range, 50 and 1000 ng/ml at high calibration range. The absolute recoveries of MA and AM at low and high calibration ranges were more than 82% and 75%, respectively. In this study the qualitative and quantitative analytical method of MA in oral fluid was established. Oral fluid testing may detect drug use in past hours because of its shorter detection window than urine, and be useful in post-accident situations. So oral fluids will be most useful for testing drug abuse in the driving under the influence of drug (DUID) as the alternative specimens of urine.

Mechanical Properties of Natural Rubber/Acrylonitrile-Butadiene Rubber Blends and Their Adhesion Behavior with Steel Cords (Natural Rubber/Acrylonitrile-Butadiene Rubber 블렌드의 기계적 물성과 강선과의 접착거동)

  • Sohn, Bong-Young;Nah, Chong-Woon
    • Elastomers and Composites
    • /
    • v.36 no.2
    • /
    • pp.111-120
    • /
    • 2001
  • Mechanical properties and their adhesion behavior with zinc- and brass-plated steel cords of natural rubber/acrylonitrile-butadiene blend compounds were investigated as a function of blend ratio. The Mooney viscosity and stress relaxation time were found to be lowered with increasing NBR content. Tensile modulus generally increased with increasing NBR content. Tensile stress at break stayed constant up to about 40 phr and showed minimum at $50{\sim}60 phr$, and thereafter increased with increasing NBR content. Strain at break decreased linearly below 50 phr, and above the level it showed nearly constant value. Based on the abrupt drops in elastic modulus and tan ${\delta}$ peak, the glass transition temperature of NR and NBR were found to be -55 and $-10^{\circ}C$, respectively. In the case of NR/NBR blend compounds, two distinct transition points were observed and each transition position was not affected by NBR level indicating an incompatible nature of NR/NBR blend system. The pullout force and rubber coverage decreased to the level of about 40% to that of pure m compound, when the 50 phr of NR was replaced by NBR. However, the pure NBR compound showed the comparable adhesion performance with NR(${\sim}90%$). The sulfur concentration was found to become lower with the increased NBR content at the adhesion interface based on the Auger spectrometer results, representing a lack of adhesion layer formation, and this was explained for a possible cause of low adhesion performance with adding NBR.

  • PDF