• Title/Summary/Keyword: MW distribution

Search Result 196, Processing Time 0.023 seconds

Change in Chemical Compositions of Leachate and Medium Density Fiberboard from a Laboratory-scale Simulated Landfill

  • Lee, Min;Prewitt, Lynn;Mun, Sung Phil
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.231-240
    • /
    • 2016
  • The change in chemical compositions of leachate and medium density fiberboard (MDF) from a laboratory-scale simulated landfill which constructed in a plastic container containing alternating layers of soil and MDF was investigated to evaluate decomposing of MDF in soil. Four treatments were conducted: 1) MDF in soil, 2) MDF only, 3) cured UF resin in soil, and 4) soil only. Molecular weight (MW) distribution of compounds in leachate from soil only treatment did not change over time. In UF resin in soil treatment, the MW distribution shifted to a lower MW distribution over time, while the peak shifted to the left indicated changing to higher MW distribution in leachate from treatment 1 and 2 contained MDF. Higher percent nitrogen in leachate was observed in MDF containing treatments due to the UF resin in the MDF. The percent carbon slightly increased in MDF only while that greatly decreased in MDF in soil treatment maybe due to bacterial activity. The percent of extractable materials from the MDF decreased greatly on day 35 compare to day 0, and subsequently did not change much on day 77. In contrast, percent holocellulose and lignin did not change much over time. No structural change of the wood fiber in MDF occurs during the study. Water-soluble materials from MDF in soil contributed the change in chemical composition of leachate.

A Study on Economic Evaluation Modeling of MVDC Distribution System for Hosting Capacity of PV System (태양광전원 수용을 위한 MVDC 배전망의 경제성평가 모델링에 관한 연구)

  • Lee, Hu-Dong;Kim, Ki-Young;Kim, Mi-Sung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.1-12
    • /
    • 2021
  • Technologies for an MVDC(medium voltage direct current) distribution system are being considered as an effective alternative to overcome the interconnection delay issues of PV systems. However, the implementation of a DC distribution system might lead to economic problems because of the development of DC devices. Therefore, this paper deals with the scale of a PV plant based on its capacity and proposes hosting-capacity models for PV systems to establish a network to evaluate the feasibility of an MVDC distribution system. The proposed models can be classified as AC and DC distribution systems by the power-supply method. PV systems with hundreds of MW, dozens of MW, and a few MW can be categorized as large-scale, medium-scale, and small-scale models, respectively. This paper also performed modeling for an economic evaluation of MVDC distribution system by considering both the cost of AC and DC network construction, converter replacement, operation, etc. The profit was composed of the SMP and REC rate of a PV plant. A simulation for economic evaluation was done for the MVDC distribution system using the present worth and equal-principal costs repayment method. The results confirmed that the proposed model is a useful tool to evaluate economic issues of a DC distribution system.

Sensitivity Analysis of Finite Fault Model in Stochastic Ground Motion Simulations (추계학적 지진동 모사에서 유한단층 모델의 민감도 분석)

  • Lee, Sang-Hyun;Rhie, Junkee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.159-164
    • /
    • 2024
  • Recent earthquakes in Korea, like Gyeongju and Pohang, have highlighted the need for accurate seismic hazard assessment. The lack of substantial ground motion data necessitates stochastic simulation methods, traditionally used with a simplistic point-source assumption. However, as earthquake magnitude increases, the influence of finite faults grows, demanding the adoption of finite faults in simulations for accurate ground motion estimates. We analyzed variations in simulated ground motions with and without the finite fault method for earthquakes with magnitude (Mw) ranging from 5.0 to 7.0, comparing pseudo-spectral acceleration. We also studied how slip distribution and hypocenter location affect simulations for a virtual earthquake that mimics the Gyeongju earthquake with Mw 5.4. Our findings reveal that finite fault effects become significant at magnitudes above Mw 5.8, particularly at high frequencies. Notably, near the hypocenter, the virtual earthquake's ground motion significantly changes using a finite fault model, especially with heterogeneous slip distribution. Therefore, applying finite fault models is crucial for simulating ground motions of large earthquakes (Mw ≥ 5.8 magnitude). Moreover, for accurate simulations of actual earthquakes with complex rupture processes having strong localized slips, incorporating finite faults is essential even for more minor earthquakes.

Effect of Ozonation and Coagulation on NOM Molecular Distribution and Activated Carbon Adsorption Capacity (응집과 오존처리가 NOM 분자량 분포특성과 활성탄 흡착능에 미치는 영향)

  • Kim, Sung Jin;Hong, Seong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.480-486
    • /
    • 2005
  • The main goals of this work are to investigate the effect of molecular weight distribution(MWD) and activated carbon adsorption capacity after conventional coagulation and enhanced coagulation. The ozonation was very effective to decompose the NOM to smaller size and to remove molecular smaller than 1,000. The concentration of DOC was reduced 0.25mg/L and 0.56mg/L by the conventional coagulation and the enhanced coagulation, respectively The conventional coagulation was not effective to remove NOM. However, the enhanced coagulation was effective to remove MW bigger than 10,000. The higher MW was shifted to smaller weight by ozonation in the raw water and the after conventional coagulation. After enhanced coagulation the MW had not changed significantly by ozonation. Also, it was observed that the ozone dosage did not have significant impact on MW shifting to smaller size. The adsorption capacity simulated by IAST comparing K values showed that the adsorption capacity was not impacted by ozone doses. There was very strong correlation between MW smaller than 10,000 and the mid- and strongly adsorbable fractions.

Environmental Noise Evaluation of the Boundary Areas for 1200MW Combined Cycle Power Plant (1200MW 복합화력 발전소가 부지경계에 미치는 환경소음 예측)

  • 이현;김연환;김희수;배용채;김성휘
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1056-1061
    • /
    • 2001
  • This paper describes the evaluation of noise influence of residental and boundary areas from power plant noise sources of 1200MW combined cycle power plant. Noise assessments are carried out by based on the ISO 3744, ISO 9613-1 and ISO 9613-2 to predict the noise distribution to satisfy the recommended noise level at specific locations and to calculate properly the octave noise power of main noise sources such as power transformers. air-intakes, stacks.

  • PDF

Evaluation of Granular Activated Carbon Process Focusing on Molar mass and size distribution of DOM (DOM의 분자량과 크기분포에 따른 입상활성탄 공정의 평가)

  • Chae, Seon H.;Lee, Kyung H .
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.31-38
    • /
    • 2008
  • The primary objective of this study was to evaluate the variation of the molecular size distribution by granular activated carbon (GAC) adsorption. GAC adsorption was assessed by using the rapid small-scale column test (RSSCT) and high-performance size-exclusion chromatography (HPSEC) was used to analyze the molecular size distribution (MSD) in the effluent of GAC column. RSSCT study suggested that GAC adsorption exhibited excellent interrelationship between dissolved organic carbon (DOC) breakthrough and MSD as function of bed volumes passed. After GAC treatment, the nonadsorbable fraction which was about 25percents of influent DOC corresponded to the hydrophilic (HPI) natural organic carbon (NOM) of NOM fractions and was composed entirely of <300 molecular weight (MW) in the HPSEC at the initial stage of the RSSCT operation. The dominant MW fraction in the source water was 1,000~5,000daltons. At the bed volumes 2,500, MW <500 of GAC treated water was risen rather than it of source water. After the bed volumes 7,300 of operation, the MW 1,000~3,000 fraction was closed to about 80percents of DOC found in the GAC influent. The Number-average molecular weight (Mn) value determined using HPSEC for the effluent of GAC column was gently increased as DOC breakthrough progress. The quotient p(Mw/Mn) can be used to estimate the degree of polydispersity was shown greatest value for the GAC effluent at the initial stage of the RSSCT operation.

Synthesis of Methylmethacrylate/acrylonitrile Organosol Copolymer

  • Ahn, Young-Ok
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.29-35
    • /
    • 1970
  • Chacterization of MMA/AN organosol copolymer and subsequent comparison with the prior art latex copolymers has been accomplished. By means of NMR analyses, we found both types of copolymers to be random. The GPC analyses show that the organosol copolymers have a singnificantly broader MW spread than latex copolymers. This is due to the low MW stabilizer which is present as a physical mixture. As a result, the MW distribution is bimodal. Fractionation of a typical organosol copolymer yields a low MW(33,000-100,000), MMA rich fraction and a high MW (250,000-330,000), AN rich fraction. Solubility-wise, the organosol copolymers are readily soluble in the lacquer solvent MEK to give a colorless film. The prio rart copolymers, hewever, were imcompletely soluble and gave yellow, hazy film.

  • PDF

Membrane Ultrafiltration for Apparent Molecular Weight Distributions of Dissolved Organic Matter

  • Seo, Jun-Won;Sa, Tongmin;Kim, Jong-Soo
    • Journal of Applied Biological Chemistry
    • /
    • v.43 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • Apparent MWDs of DOM in natural waters and swine wastewaters were determined through membrane ultrafiltration. The nominal MWCOs of ultrafiltration membranes by the manufacturer were confirmed to be similar with those obtained from the ultrafiltration procedures employed in this study using six MW standard compounds. Natural waters showed a wide range of MWOs, but 62.4~87.5% were in the range of MW<10K. High MW fractions were preferentially removed through water treatment processes. Swine wastewater showed two major ranges of MWDs, 49.0% in <1K and 36% in >50k while anaerobically treated swine wastewaters showed 17.5~18.0% in <1K and 53.0~58.8% in <50K. The overall DOM was reduced during anaerobic treatment by 76.8~80.0% as COD; however. the percentage of low MW fractions decreased and that of the high MW fractions increased.

  • PDF

Characteristics of DOC Removal by Coagulation Process in the Water Treatment of Nakdong River (낙동강 수계에 대한 정수처리공정에서 응집공정의 DOC 제거 특성)

  • Hwang, Deok-Heung;Kim, Dong-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.2
    • /
    • pp.66-73
    • /
    • 1999
  • This study was carried out to derive the removal characteristics of target materials(DOC and turbidity) during the coagulation process after the injection of coagulants(PACl and FeCl3). Used apparatus were a jar test and a pilot plant. A great portion of DOC among the total removed DOC was achieved at the slow mixing process among the coagulation process. The ranges of removed DOC and optimum pH for each coagulant were 0.45~1.47mg/l and 6.0~6.5 by PACl, and 0.97~2.61mg/l. and 5.0~5.5 by FeCl3, respectively. Both of coagulants showed little increase of DOC removal above coagulant dosage 20mg/l Molecular weight distribution(MWD) of removed DOC was measured by get filtration(GF) technique. The MWD variation by gel filtrationin(GF) for removed DOC in the coagulation process were as follows; for raw water, the percentages of each MWD for total area were < MW 6,500 25.5%, MW 6,500~66,000 67.1%, and > MW 66,000 7.4%. For the same coagulant dosage(12mg/l), the percentages of each MWD for total area by PACl were < MW 6,500 20.5%, MW 6,500~66,000 48.7%, and > MW 66,000 9.1%, and those of FeCl3 were MW 66,000 18.2%. For each coagulant, the removal percentage of MW 6,500~66,000 occurred a little, but at a part of

  • PDF

Conceptual application methodology of 22.9㎸ HTS cable in metropolitan city of Republic of Korea

  • Yoon, Jae-Young;Kim, Jong-Yul;Lee, Seung-Ryul
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.15-19
    • /
    • 2004
  • As the power demand has increased and power industry deregulation has progressed, the transmission and distribution system will have more complicated problems by the influence of investment reduction and NIMBY phenomena for overall power system. It is expected that the route length per MW demand will reduce gradually from 0.6[C-km/MW] to 0.53 [C-km/MW] in 2010. This comes up to a real serious problem of system planning and operational viewpoints. HTS technologies related to power system have properties to solve these complex transmission and distribution constraints, especially for metropolitan area, in the future. As the HTS technology has developed, the HTS cable technology can be the most effective alternative to solve the future expected power network constraints. This paper describes the application methodology of developing 22.9㎸ HTS cable by CAST for practical distribution system. 22.9㎸ HTS cable under development with step-by-step application methodology can substitute the existing and planning conventional 154㎸ cable. If this scheme is applied, part of downtown 154㎸ substation of metropolitan city such as Seoul can be changed into 22.9㎸ switching station. It can give great economic, environmental and additional benefits to all of the concerned authorities.