• Title/Summary/Keyword: MVA

Search Result 330, Processing Time 0.025 seconds

Cloning and Characterization of the $_L$-Lactate Dehydrogenase Gene (IdhL) from Lactobacillus reuteri ATCC 55739

  • Park, Jar-Yong;Park, Sun-Jung;Nam, Su-Jin;Ha, Yeong-Lae;Kim, Jeong-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.5
    • /
    • pp.716-721
    • /
    • 2002
  • The ldhL gene encoding the $_L$-(+) lactate dehydrogenase was cloned from Lactobacillus reuteri ATCC 55739 chromosomal DNA and characterized. An internal 750-bp fiagment of ldhL gene was amplified by PCR using primers based on the conserved region of lactobacilli ldhL genes. A genomic library off. reuteri ATCC 55739 was constructed using pBR322, and colony hybridization experiments were performed using the 750-bp fragment as aprobe. One clone harboring a 4.0-kb PstI fragment was identified, and nucleotide sequencing confirmed it as an open reading frame of 972 bp in size in the middle. In addition to IdhL gene, an ORF homologous to Streptococcus pneumoniae TIGR4 hydrolase gene and 3' part of phosphomevalonate kinase gene (mvaK2) were also found on the 4 kb fragment. $_L$-LDH of L. reuteri ATCC 55739 showed the highest degree of homology with the $_L$-LDH of Pediococcus acidilactici (62.4%), fullowed by the $_L$-LDH of Lactobacillus pentosus (58.7%). The size of IdhL transcript determined by Northern blot was 1 kb, indicating the monocistronic nature of IdhL.

On-Line Detection of Shorted Turn in Generator Rotor Windings (발전기 회전자 권선의 운전중 층간단락 탐지)

  • Kim, Hui-Dong;Lee, Yeong-Jun;Park, Jong-Jeong;Ju, Yeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.3
    • /
    • pp.192-199
    • /
    • 1999
  • During start up and shut down, the generator is rotating at a low speed and copper dusts cause arcing between the turns in the slot. Shorted turns occurred primarily by the movement of these copper dusts between individual windings in the generator rotor. Detection of shorted turns was performed in five gas turbine generators in two combined cycle power plants. Two types of permanent and temporary flux probes were used in this paper. These flux probes have been used to develop a methodology for detecting shorted turns in an operating generator's rotor. The flux probes sense the rotor winding slot leakage flux and produce a voltage proportional to the rate of change of the flux. This pattern of flux variation is the signature unique to each rotor winding. An appropriate waveform analysis technique canidentify the pole location, the slot number, and the number of shorted turns within each slot. Shorted turns in field winding of gas turbine generator(125.7 MVA) were detected to twelve turns on al total 190 turns.

  • PDF

Insulation Design and Test of Model Windings for the Development of High Temperature Superconducting Transformer (고온초전도변압기 개발을 위한 모델 권선의 절연 설계 및 평가)

  • Joung, Jong-Man;Baek, Sung-Myeong;Kwak, Dong-Sun;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.19-22
    • /
    • 2003
  • In the response to increasing the demands for electrical energy, much effort aimed to develop and commercialize 1MVA HTS power equipments that is supported by a grant from center for Applied Superconductivity Technology of the 21st Century Frontier R&D Program funded by the Ministry of Science and Technology is going on in Korea. For the development, the cryogenic insulation and winding insulation of it in this paper are discussed. In the first many types of dielectric insulating tests were carried out. In detail Breakdown characteristics of $LN_2$, FRP and turn insulating films, flashover characteristics along the FRP surface in $LN_2$ were verified after distinguishing insulation components in HIS windings. And then model windings were designed and insulation test was conducted. These included a AC withstand voltage test of 50kV rms and a lightning impulse test of 150kV at peak.

  • PDF

A Study of Economic Value Added Disclosures in the Annual Reports: Is EVA a Superior Measure of Corporate Performance?

  • Bhasin, Madan Lal
    • East Asian Journal of Business Economics (EAJBE)
    • /
    • v.5 no.1
    • /
    • pp.10-26
    • /
    • 2017
  • This paper explains the concept of Economic Value Added (EVA) that is gaining popularity in India. We also examine whether EVA is a superior performance measure, both for corporate disclosure and for internal governance. Of late, companies in India have started focusing on shareholders wealth creation by adopting value-based models for measuring shareholder value that helps to align managerial decision-making with the firm preferences. In recent years, the EVA framework is gradually replacing the 'traditional' measures of financial performance on account of its robustness and its immunity from 'creative' accounting. Even though some leading Indian companies have already joined the band wagon of their American counterparts in adapting the EVA-based corporate performance systems, many other are hesitating as there is no strong evidence that the EVA system works in India. Till now, EVA disclosures are "not mandatory for the Indian companies." Also, we examine the value-creation strategies of selected Indian companies by analyzing whether EVA better represents the market-value of these companies in comparison to conventional performance measures. The study indicates that "there is no strong evidence to support Stern Stewart's claim that EVA is superior to the traditional performance measures in its association with MVA." As part of this study, we have also extensively surveyed the EVA disclosures in the Annual Reports made by the same sample group of 500 corporations from India.

Development of 30kVA Superconducting Generator (I) : Structure and Manufacturing (30kVA 초전도발전기 개발 (I) : 구조와 제작)

  • Sohn, M.H.;Baik, S.K.;Kwon, Y.K.;Ko, R.K.;Bae, J.H.;Lee, E.Y.;Jin, H.B.;Ryu, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.229-231
    • /
    • 1999
  • For the first time in Korea, a 30kVA superconducting generator has been designed, developed and successfully tested recently. This is the forerunner of a 1MVA superconducting generator which is currently under development. The paper discusses the structure and manufacturing of a superconducting generator. Helium transfer coupling has 3 passages of the recovered Helium gas and a gas flow control system.

  • PDF

Mechanical Analysis of Field Coil Deformation in Gas Turbine Generator (가스터빈 발전기의 계자권선 손상에 관한 역학적 분석)

  • Han, Seok-Woo;Kwon, Young-Dong;Choe, Gyu-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.107-109
    • /
    • 1998
  • This paper presents mechanical analysis of gas turbine generator (113MVA, $3{\phi}$, 2P, 0.9PF, F class, 3600rpm, 60Hz, 13.8kV, 4.72kA, Air-Cooling) field coil deformation. Rotor end coil deformation is only appeared on turbine end but collector end coil is normal. Expansion direction of end coil is tangential not axial. Deformation appears more severe at top turn. Retaining ling is expanded by centrifugal force of coil and itself. In case friction coefficient between coil top surface and retaining ring insulation inner surface is small, coil end length ${\ell}$ does not change. However, in case friction coefficient big condition, coil end is expanded ${\Delta}{\ell}$ due to start and stop. Deformation is assumed about 30mm by watching photograph inner surface of retaining ring is coated by Teflon at manufacturing condition. Usually Teflon coating insulation surface is small friction coefficient. It's value 0.08${\sim}$0.15. However it's value exceeds more than 0.297. Since top turn deformation appears. The distortion and subsequent failure have occurred because of the lack of a sufficient slip-plane between the top field coil conductors and the inside surface of the retaining ring insulation on the turbine end of the field-winding.

  • PDF

A study on the Insulation Condition Evaluation and Insulation Reinforced Method of Large Motors (대형모타 절연상태 판정기준 및 절연보강 방안 연구)

  • Kim, Young-Kyu;Park, Duk-Kyu;Song, Young-Cheol;Kim, Hyeon-Il
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1912-1914
    • /
    • 2000
  • This is the first report of a series of field test result of large high voltage generator & motors. Major specimens were 6.6/13.2kV class hydroric power & pump motor that was installed and operated for public water service by KOWACO(KOrea WAter resources COperation). The capacity of specimen gene rater & motors were in range of several hundred kVA$\sim$50MVA. Until now, we get the 100 field test result by testing technique discribed in IEEE standards and Discharge map technique from Japanse manufactures. The test result was varied very wide range, and there was a tendency according to insulation material and manufacture.

  • PDF

A Study on the Effective Downscaling Methodology for Design of a Micro Smart Grid Simulator

  • Ko, Yun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1425-1437
    • /
    • 2018
  • In this paper, a methodology was proposed to reduce the electrical level and spatial size of the smart grid with distributed generations (DGs) to a scale in which the electrical phenomena and control strategies for disturbances on the smart grid could be safely and freely experimented and observed. Based on the design methodology, a micro smart grid simulator with a substation transformer capacity of 190VA, voltage level of 19V, maximum breaking current of 20A and size of $2{\times}2m^2$ was designed by reducing the substation transformer capacity of 45MVA, voltage level of 23kV and area of $2{\times}2km^2$ of the smart grid to over one thousandth, and also reducing the maximum breaking current of 12kA of the smart grid to 1/600. It was verified that the proposed design methodology and designed micro smart grid simulator were very effective by identifying how all of the fault currents are limited to within the maximum breaking current of 20A, and by confirming that the maximum error between the fault currents obtained from the fault analysis method and the simulation method is within 1.8% through the EMTP-RV simulation results to the micro smart grid simulator model.

Characteristics of Critical Current Degradation with Bending Diameter of High Temperature Superconducting Cable (고온 초전도 케이블의 굽힘 직경에 따른 임계전류 저하 특성)

  • Kim Hae Joon;Kim J.H.;Cho J.W.;Sim K.D.;Bae J.H.;Kim H.J.;Seong K.C.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1067-1069
    • /
    • 2004
  • 22.9[kV]/50[MVA]/30[m] HTS transmission power cable has been developed and tested at Korea Electrotechnology Research Institute and LG Cable Company by 21 century center for applied superconductivity technology. It is necessary to measure of critical current degradations, AC loss, insulation test and etc at the HTS cable development. This paper is analyzed characteristics that critical current of HTS cable bending condition according to this paper. We will be able to decide the diameter of drum which HTS cable is wound around and minimum curvature radius of HTS cable from results of this research.

  • PDF

Study of the Design of Data Acquisition and Analysis Systems for Multi-purpose Regional Energy Systems

  • Lee, Han-Sang;Yoon, Dong-Hee;Jang, Gil-Soo;Park, Jong-Keun;Park, Goon-Cherl
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.16-20
    • /
    • 2010
  • Recently, the smart grid has become a hot issue and interest in related power sources have increased accordingly. The implementation of a smart grid can enable many generation resources to be linked to the power system, including small-scale reactors for the purpose of co-generation. Research on small-scale reactors is being carried out all over the world. Similarly, Korea is also conducting research on multi-purpose regional energy systems using nuclear energy. This paper proposes a real-time data acquisition and analysis system for small-scale reactors, and is known as the REX-10 (Regional Energy rX 10 MVA). This analysis requires real-time simulations for the power system since it needs data communication with a remote REX-10. A RTDS (Real Time Digital Simulator) has been used for the simulation, and a SCADA/HMI system interfaced with the RTDS is proposed for the purpose of monitoring and control of the regional energy system.