• Title/Summary/Keyword: MVA

Search Result 330, Processing Time 0.034 seconds

Dynamic Interaction Analysis of Interconnected Wind Power Generator using Computer Simulation and Real-Size Hardware Simulator (컴퓨터 시뮬레이션과 실규모 하드웨어시뮬레이터를 이용한 계통연계 풍력발전의 응동특성 분석)

  • Yun, Dong-Jin;Han, Byung-Moon;Choy, Young-Do;Jeon, Young-Soo;Jeong, Byoung-Chang;Chung, Yong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1047_1048
    • /
    • 2009
  • This paper describes comparative analysis results about the dynamic interaction of interconnected wind power system using the actual-size hardware simulator and the simulation model with PSCAD/EMTDC. The hardware simulator, which is composed of 2.0MVA induction motor with drive system and 1.5MW doubly-fed induction generator, was built and tested in Go-Chang Test Site of KEPCO for analyzing the dynamic interaction with the interconnected distribution system. The operation of hardware simulator was verified through comparative analysis between experimental results and simulation results obtained by simulation model with PSCAD/EMTDC. The developed hardware simulator and simulation model could be effectively used for analyzing the dynamic interaction, which has various phenomena depending on the wind variation and the network state of interconnected power system.

  • PDF

A Study on the Characteristics of HTS Cable System Operation and Cooling Load in a Load Unbalance (불평형 부하에서의 초전도케이블 운전 및 냉각부하 특성에 관한 연구)

  • Sohn, S.H.;Lim, J.H.;Yang, H.S.;Choi, H.O.;Ma, Y.H.;Kim, D.L.;Ryoo, H.S.;Ryu, K.W.;Hwang, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.397_398
    • /
    • 2009
  • Demonstrations to deploy high temperature superconducting (HTS) cable to the real gird are actively carried out throughout the world. Power utilities have an interest in the inherent advantage of the HTS cable system, and achieve the expected results from the series of verification test. To embody the reliability in the phenomenon occurred commonly in three-phase system, we simulate the load unbalance. A 22.9 kV large scale HTS cable system with the specification of 100 m-long, 50 MVA capacity has been tested with up to 30% unbalance rate. To evaluate the effect of AC loss increase due to the unbalanced load, the cooling loads are measured by the calorimetry method. In this paper, the correlation between AC loss and load unbalance is described and investigated precisely.

  • PDF

Loss Characteristics of the 100m Gochang HTS-cable System (100m급 고창HTS-케이블시스템의 손실특성)

  • Li, Z.Y.;Ma, Y.H.;Jin, H.B.;Ryu, K.;Sohn, S.H.;Hwang, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.298_299
    • /
    • 2009
  • 전력분야 응용 중, 특히 교류손실측면에서 장점을 지니고 있는 HTS-케이블 및 HTS-한류기의 경우는 선진 세계 각 국에서 배전급 전력계통에 실증시험을 하는 단계까지 와 있는 실정이다. 국내에서도 한전 주관으로 실증시험을 그 목적으로 고창시험장에 100m급, 22.9kV/50MVA HTS-케이블이 설치되어 운전되고 있다. 이와 같이 다수본의 HTS-테이프로 구성되는 HTS-케이블에서 발생되는 교류손실은 HTS-케이블의 효율을 저하시킬 뿐만 아니라 냉동기비용 증가를 초래하지만 HTS-케이블 구조의 복잡성으로 인하여 교류손실에 대한 평가가 매우 난해하다. 따라서 본 논문에서는 고창HTS-케이블의 교류손실에 대하여 실험적 이론적 조사 및 검토를 하였다. 그 주요결과를 요약하면, 측정된 Bi도체의 교류손실에 대한 손실지수 ${\kappa}$는 약 2.5로 Cu 도체에서 발생하는 Ohmic손실의 지수(~2)와 비교하여 큰 것을 볼 수 있다. 또한 전기적인 방법으로 측정한 HTS-케이블의 총손실은 열량법으로 측정한 손실과 잘 일치한다.

  • PDF

Performance Comparison Analysis for Interconnected Wind Power Generator using Computer Simulation and Real-Size Hardware Simulator (컴퓨터시뮬레이션과 실용량 하드웨어시뮬레이터를 이용한 계통연계 풍력발전의 성능비교분석)

  • Yun, Dong-Jin;Oh, Seung-Jin;Han, Byung-Moon;Jeong, Byoung-Chang;Jung, Yong-Ho;Choy, Young-Do;Jeon, Young-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.263-269
    • /
    • 2009
  • This paper describes comparative analysis results about the dynamic interaction of interconnected wind power system using the actual-size hardware simulator and the simulation model with PSCAD/EMTDC. The hardware simulator, which is composed of 2.0MVA induction motor with drive system and 1.5MW doubly-fed induction generator, was built and tested in Go-Chang Test Site of KEPCO for analyzing the dynamic interaction with the interconnected distribution system. The operation of hardware simulator was verified through comparative analysis between experimental results and simulation results obtained by simulation model with PSCAD/EMTDC. The developed hardware simulator and simulation model could be effectively used for analyzing the dynamic interaction, which has various phenomena depending on the wind variation and the network state of interconnected power system.

Assessment of an Apo-1/Fas Promoter Polymorphism in Korean Schizophrenia Patients

  • Kim, Soon-Ae;Kim, Youn-Jung;Choe, Bong-Keun;Lee, Hee-Jae;Kim, Jong-Woo;Park, Jong-Deuk;Kim, Chang-Ju;Park, Seung-Joon;Jung, Jee-Chang;Chung, Joo-Ho
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.6 no.3
    • /
    • pp.161-163
    • /
    • 2002
  • Apoptosis has been hypothesized to be involved in the pathogenesis in schizophrenia. A large number of genes are known to mediate the apoptotic process; Apo-1/Fas (CD95) is a well-known example of such genes. In the present study, MvaI restriction fragment length polymorphism, a polymorphic marker present within the Apo-1/Fas gene, was examined in a population consisting of 226 control subjects and 110 schizophrenia patients, all of them Korean in ethnicity. No statistically significant difference in the genotypic distribution and allelic frequencies was observed between the control and the schizophrenia patient group. To find out the precise effect of Apo-1/Fas gene polymorphisms on the susceptibility to schizophrenia, further studies are warranted to investigate possible involvement of other polymorphisms with a larger sample population.

Calculation of Distribution Network Charging for DG Embedded Distribution System (분산전원 투입을 고려한 배전망 이용요금 산정에 관한 연구)

  • Hwang, Seok-Hyun;Kim, Mun-Kyeom;Park, Jong-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.513-521
    • /
    • 2012
  • With the advent of smart grid, distribution network charges have been one of keystones of ongoing deregulation and privatization in power industries. This paper proposes a new charging methodology to allocate the existing distribution network cost with an aim of reflecting the true cost and benefit of network customers, especially of distribution generator (DG). The proposed charging methodology separates distribution network costs due to the respective real and reactive power flows. The costs are then allocated to network users according to each charge for the actual line capacity used and available capacity. This distribution network charging model is able to provide the economic signals to reward network users who are contributing to better power factors, while penalizing customers who worsen power factors. The proposed method is shown on IEEE 37 bus system for distribution network, and then the results are validated through the comparison with the MW-Miles and MVA-Miles methods. The charges derived from the proposed method can provide appropriate incentives/penalties to network customers to behave in a manner leading to a better network condition.

Advances in Biochemistry and Microbial Production of Squalene and Its Derivatives

  • Ghimire, Gopal Prasad;Nguyen, Huy Thuan;Koirala, Niranjan;Sohng, Jae Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.3
    • /
    • pp.441-451
    • /
    • 2016
  • Squalene is a linear triterpene formed via the MVA or MEP biosynthetic pathway and is widely distributed in bacteria, fungi, algae, plants, and animals. Metabolically, squalene is used not only as a precursor in the synthesis of complex secondary metabolites such as sterols, hormones, and vitamins, but also as a carbon source in aerobic and anaerobic fermentation in microorganisms. Owing to the increasing roles of squalene as an antioxidant, anticancer, and anti-inflammatory agent, the demand for this chemical is highly urgent. As a result, with the exception of traditional methods of the isolation of squalene from animals (shark liver oil) and plants, biotechnological methods using microorganisms as producers have afforded increased yield and productivity, but a reduction in progress. In this paper, we first review the biosynthetic routes of squalene and its typical derivatives, particularly the squalene synthase route. Second, typical biotechnological methods for the enhanced production of squalene using microbial cell factories are summarized and classified. Finally, the outline and discussion of the novel trend in the production of squalene with several updated events to 2015 are presented.

Performance Evaluation on the Delay and the Throughput between the Stations on the Interconnected LANs (상호접속된 근거리 통신망 환경에서의 단말간 전송 성능 평가)

  • Yoe, Hyun;Lim, Jae-Hwan;Choi, Seung-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.4
    • /
    • pp.336-345
    • /
    • 1992
  • In this paper, the performance evaluation on the throughput and the delay between station under the interconnected LANs environments is studied. The connection is formed through bridges. Interconnected system is modelled as single-chain and multiple-chain closed queueing networks. For performance enaluation the iteration algorithm, which is based on the MVA(Mean Value Analysis)is proposed, Various system parameters, such as chain population interconnected communication link capacity, and service times of several queues, are used for the investigation of their influence of the station to station performance, Transport and MAC layers are mainly taken into consideration for the layer modeling. The analysis is shown as a graph by computer programming.

  • PDF

Iron Core Design of 3-Phase 40MVA HTS Power Transformer Considering Voltages per Turn

  • Lee, Chan-joo;Seok, Bok-yeol
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.2
    • /
    • pp.54-58
    • /
    • 2004
  • This paper presents the iron core design method of a high temperature superconducting (HTS) transformer considering voltages per turn (V/T). In this research, solenoid type HTS coils were selected for low voltage (LV) winding and double pancake coils for high voltage (HV) winding, just as in conventional large power transformers. V/T is one of the most fundamental elements used in designing transformers, as it decides the core cross sectional area and the number of primary and secondary winding turns. By controlling the V/T, the core dimension and core loss can be changed diversely. The leakage flux is another serious consideration in core design. The magnetic field perpendicular to the HTS wire causes its critical current to fall rapidly as the magnitude of the field increases slowly. Therefore in the design of iron core as well as superconducting windings, contemplation of leakage flux should be preceded. In this paper, the relationship between the V/T and core loss was observed and also, through computational calculations, the leakage magnetic fields perpendicular to the windings were found and their critical current decrement effects were considered in relation to the core design. The % impedance was calculated by way of the numerical method. Finally, various models were suggested.

Design Considerations of 2-pole Synchronous Superconducting Rotating Machine (2극 초전도 동기기 설계법 고찰)

  • Baik, S.K.;Sohn, M.H.;Lee, E.Y.;Kwon, Y.K.;Ryu, K.S.;Jo, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.865-867
    • /
    • 2001
  • Generally large synchronous rotating machines with 2 poles have more merits than the others with more than 2 poles Superconducting synchronous rotating machines also have the same tendency, but they have different structure from conventional ones because of no magnetic core inside of the rotor. As the result, design approaches of the superconducting field coils are also different, which would be classified into 2 types according to their coil shapes. The first one is race-track type and the other is saddle type Race-track type machines have almost the same structure with conventional salient pole generators which are being used as largely small scale machines with more than 2 poles. On the other hand saddle type machines correspond to conventional cylindrical generators with 2 poles used for large turbine system in power plants. In this paper several types of superconducting field coils are introduced for 2 pole superconducting machine design and then the feasibility of each type is considered. Moreover, based on the consideration. 1MVA superconducting generator(S.G.) with saddle type field coil is designed electromagnetically.

  • PDF