• 제목/요약/키워드: MVA

검색결과 330건 처리시간 0.027초

HTS변압기에서 액체질소 표면 상부의 열전달 해석 (Heat Transfer Analysis above L$N_2$ Surface in HTS Transformer)

  • 최연석;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.174-177
    • /
    • 2003
  • Cooling load from the top plate to L$N_2$ surface, including wall conduction, gas conduction, radiation, and current leads, is investigated in a closed cooling system for HTS transformer. In general methods of load calculation, individual load is estimated separately, but they are actually coupled each other because of natural convection of nitrogen vapor. Using heat transfer analysis, we calculate cooling load with taking into account the effect of natural convection. Cooling load is under- estimated approximately 2 % when the natural convection is ignored. If the operating current is high, there will be a wide difference between actual cooling load and cooling load by individual calculation. Cooling load decreases with increasing number of radiation shield. With production, construction, and cooling load, three radiation shields are proper to 1 MVA HTS transformer.

  • PDF

EMTDC를 이용한 UPFC의 스위칭 레벨 시뮬레이션 모형 개발 (Development of the UPFC Switching Level Simulation Model using EMTDC)

  • 한병문;백승택;문승일;이학성;유일도;추진부;장병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.15-19
    • /
    • 2001
  • 본 논문에서는 한전에서 강진변전소에 파이롯플랜트로 설치 중에 있는 80MVA 용량의 3-레벨 12-펄스형 UPFC의 EMTDC 모델링에 대해 기술하고 있다. UPFC의 EMTDC를 이용한 시뮬레이션 모형은 그 목적에 따라 상세 정도가 상이한 다양한 형태가 존재하나 본 연구에서는 향후 RTDS에 연계하여 전력계통과의 동적 성능 평가에 적용 가능하도록 인버터를 스위칭 레벨 다중펄스 전압원으로 모델링하였다. 개발된 시뮬레이션모형의 타당성은 정현파 이상진원을 사용한 시뮬레이션 분석결과와 비교검토 하여 검증하였다. 개발된 시뮬레이션모형은 UPFC의 성능분석과 전력계통과의 동적응동 해석에 유용하게 활용 가능하고 또한 UPFC 운전자에게 동작특성과 초보적인 운전특성을 교육하는데도 활용가능 할 것으로 보인다.

  • PDF

양수발전기 고정자 권선에서 운전중 및 정지중 부분방전 특성 (On-Line and Off-Line Partial Discharge Properties in the Pumped Storage Generator Stator Windings)

  • 김희동;주영호;윤대헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2089-2092
    • /
    • 1999
  • Partial discharge(PD) tests were performed both when the pumped storage generator(rated 13.8kV and 220MVA) was on-line and off-line. This generator has been equipped with 12 bus coupler sensors in directional mode. PD tests were conducted using partial discharge analyzer(PDA), partial discharge meter(PDM) and digital partial discharge detector. PDA showed that the patterns of the normalized quantity number(NQN) and the partial discharge magnitude are in accord with on-line and off-line. The insulation condition was estimated by diagnostic tests(off-line) such as PD magnitude and dissipation factor.

  • PDF

765kV 변압기 탱크 분리운전 (Devided operation by each Tank of 765kV Transformer)

  • 김문덕;정시환;박종명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2317-2319
    • /
    • 1999
  • 765kV Transformer, bank capacity is 2,000MVA, is developed of two seperated tanks per phase because transportation weight of the transformer needs to be reduced. So we will operate one tank per phase in some case, low load or black down of 1 tank, using the one phase-two tank type of 765kV transformer to cut down the cost and improve the reliability of substation.

  • PDF

고전압 초전도 변압기용 연속 디스크 권선의 특성 (Characteristics of a Continuous Disk Winding for Large Power HTS Transformers)

  • 황영인;이승욱;김우석;최경달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.883-884
    • /
    • 2006
  • 본 논문에서는 디스크 권선과 레이어 권선의 장점을 가지는 연속디스크 권선의 변압기 적용가능성을 확인하기 위하여 전위된 병렬선재를 이용하여 연속 디스크 권선을 제작하였다. 제작된 연속 디스크 권선의 임계전류 및 교류손실 측정을 통하여 실제 변압기 권선방법으로의 적용 가능성을 확인 하였다. 또한 33 MVA 초전도 변압기의 고압측에 사용될 권선형태를 레이어 권선, 연속 디스크 권선을 적용하였을 경우 발생하는 손실을 계산하였다.

  • PDF

포화현상을 고려한 비율차동계전기의 동특성 해석 (Danamic Characteristics of Percentage Differential Relays Considering Saturation Effect)

  • 김남호;김일남;이준창
    • 산업기술연구
    • /
    • 제14권
    • /
    • pp.89-100
    • /
    • 1994
  • The effects of transient inrush currents on the dynamic characteristics of percentage differential relays are studied when the power transformers are reenergized. An algorithm of estimation the nonlinear magnetic property of power transformer and current trnasformer core are developed. Using this method, we can analyze the effect of inrush currents on the trip region of the percentage differential relays corresponding to the variation of the phase angle and the residual magnetism at the instant of switch closing. Test results are used to verify the availibility of the proposed algorithm. Finally a case study is performed to the 110 MVA main transformer in hydraulic power station.

  • PDF

PSCAD/EMTDC를 이용한 DVR의 전압보상 효과분석 (Analysis on Voltage Compensating Effect of DVR using PSCAD/EMTDC)

  • 박상호;최영도;박영신
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.165-171
    • /
    • 2010
  • There are many researches on Power Quality Device to protect the critical load and power system as the nonlinear load and precision load are adopted into the power system recently. To analyze the voltage compensation of voltage sag and voltage swell by DVR, which is connected to the important load in series, this paper shows PSCAD/EMTDC simulation and its verification by comparing with the actual DVR output of 2MVA. DVR control scheme in this paper is applicable to compensate single-phase, 2-phases or 3-phases voltage sag as well as DVR for distribution system.

30[kVA] 초전도발전기용 계자코일 설계 (30[kVA] Superconducting generator Field coil Design)

  • 백승규;손명환;고락길;이언용;배준한;권영길;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.232-234
    • /
    • 1998
  • Race-track type superconducting coils are used for wiggler magnets of accelerators and field coils of superconducting generators(S.C.G) and so on. The shape is different from ordinary solenoidal type magnet, so the manufacturing situation and conditions become different and moreover according to these results the output characteristics of magnet also becomes different. In this paper we are dealing with race-track type coil design that is inserted into 30(kVA) S.C.G which will be manufactured before we make l(MVA) S.C.G plant. The design procedure is based on two dimensional electromagnetic analysis including laplace equations in cylindrical coordinate.

  • PDF

대용량 터빈발전기 고정자 권선의 정지중 및 운전중 부분방전 특성 (Off-Line and On-Line Partial Discharge Properties of Large Turbine Generator)

  • 김희동;이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1846-1849
    • /
    • 2000
  • Off-line and on-line partial discharges were measured on a 828MVA, 22kV and direct hydrogen-cooled large turbine generator. Partial discharge tests were conducted using digital partial discharge detector(PDD) and turbine generator analyzer(TGA). PDD and TGA showed that off-line partial discharge pattern seems to be very, similar to that found with on-line. Most of the partial discharge is originating with the stator slot in the three phases. As the partial discharge activity is very low, the stator insulation condition of this generator is very good.

  • PDF

공진형 콘버터를 이용한 직렬보상기와 병렬보상기의 비교 연구 (Comparison of HFLC Series Compensator and HFLC Shunt Compensator)

  • 정교범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.468-470
    • /
    • 1995
  • In this paper, a series compensator with a resonant LC circuit and a shunt compensator with the resonant circuit are compared based on the respective rating of its circuit elements. The rating are calculated over a range of compensation and over a range of bus angle. The components ratings are expressed in a per unit values. The results of this study can be easily converted to actual MVA by a simple change in scale. The methodology presented to rate the various components within the system will help to determine the feasibility of various FACTS devices in costs.

  • PDF