• Title/Summary/Keyword: MV photon beam

Search Result 199, Processing Time 0.024 seconds

Development of Phantom and Comparison Analysis for Performance Characteristics of MOSFET Dosimeter (MOSFET 선량계 특성분석을 위한 팬톰 개발 및 특성 비교)

  • Chung, Jin-Beom;Lee, Jeong-Woo;Kim, Yon-Lae;Lee, Doo-Hyun;Choi, Kyoung-Sik;Kim, Jae-Sung;Kim, In-Ah;Hong, Se-Mie;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.48-54
    • /
    • 2007
  • This study is to develope a phantom for MOSFET (Metal Oxide Semiconductors Field Effect Transistors) dosimetry and compare the dosimetric properties of standard MOSFET and microMOSFET with the phantom. In this study, the developed phantom have two shape: one is the shape of semi-sphere with 10cm diameters and the other one is the flat slab of $30{\times}30cm$with 1 cm thickness. The slab phantom was used for calibration and characterization measurements of reproducibility, linearity and dose rate dependency. The semi-sphere phantom was used for angular and directional dependence on the types of MOSFETs. The measurements were conducted under $10{\times}10cm^2$ fields at 100cm SSD with 6MV photon of Clinac (21EX, Varian, USA). For calibration and reproducibility, five standard MOSFETS and microMOSFETs were repeatedly Irradiated by 200cGy five times. The average calibration factor was a range of $1.09{\pm}0.01{\sim}1.12{\pm}0.02mV/cGy$ for standard MOSFETS and $2.81{\pm}0.03{\sim}2.85{\pm}0.04 mV/cGy$ for microMOSFETs. The response of reproducibility in the two types of MOSFETS was found to be maximum 2% variation. Dose linearity was evaluated In the range of 5 to 600 cGy and showed good linear response with $R^2$ value of 0.997 and 0.999. The dose rate dependence of standard MOSFET and microMOSFET was within 1% for 200 cGy from 100 to 500MU/min. For linearity, reproducibility and calibration factor, two types of MOSFETS showed similar results. On the other hand, the standard MOSFET and microMOSFET were found to be remarkable difference in angular and directional dependence. The measured angular dependence of standard MOSFET and microMOSFET was also found to be the variation of 13%, 10% and standard deviation of ${\pm}4.4%,\;{\pm}2.1%$. The directional dependence was found to be the variation of 5%, 2% and standard deviation of ${\pm}2.1%,\;{\pm}1.5%$. Therefore, dose verification of radiation therapy used multidirectional X-ray beam treatments allows for better the use of microMOSFET which has a reduced angular and directional dependence than that of standard MOSFET.

  • PDF

Introduction and feasibility study of the HD-270 MLC (HD-270 MLC의 소개 및 유용성평가)

  • Kim Dae Young;Kim Won Taek;Lee Hwa Jung;Lee Kang Hyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • I. Purpose The multileaf collimator(MLC) has many advantages, but use of the MLC increased effective penumbra and isodose undulation in dose distribution compared with that of an alloy block. In this work, we introduced the HD-270 MLC, which can improve the above disadvantages of MLC, and reported its feasibility study. II. Method and Materials The HD-270 MLC is a technique which combines the use of the existing Siemens multileaf collimator(3D MLC) with patient translation perpendicular to the leaf plane. The technique produces a smoothed isodose distribution with the reduced isodose undulation and effective penumbra. To assess the efficacy of the HD-270 technique and determine the appropriate resolution, a polygonal shaped MLC field was made to produce field edge angles from 0 degree to 75 degree with a step of 15 degree. Each HD-270 group was generated according to the allowed resolution, i. e., 5, 3, and 2mm. The experiment was carried out on Primus, a Siemens linear accelerator configured with HD-270 MLC. The total 60 MU of 6 MV photon beam was delivered to X-Omat film(Kodak, USA) at a SAD of 100 cm and 1.5 cm depth in solid water phantom. Exposed films were scanned by Lumiscan75(LUMISYS) and analyzed using RIT113 software(Radiological Imaging Technology Inc., USA). To test the mechanical accuracy of table movement, the transverse, longitudinal, and vertical positions were controlled by a consol with ${\pm}5\;mm,\;{\pm}4\;mm,\;{\pm}3\;mm,\;and\;{\pm}2\;mm$ steps, and then measured using a dial gauge with an accuracy of 0.001 inch. During the experiments, the table loaded with about 50Kg human phantom to simulate the real treatment situation. III. Results The effective penumbra and isodose undulation became larger with increase the resolution and field edge angle. The accuracy of the table movement on each direction is good within the ${\pm}1\;mm$. IV. Conclusion Clinical use of the MLC can be increased by using of the HD-270 MLC which complements to the disadvantages of the MLC.

  • PDF

The Role of Postoperative External Irradiation for the Incompletely Resected Meningiomas (불완전절제된 수막종에서 수술 후 방사선치료의 역할)

  • Kim Tae-Hyun;Yang Dae-Sik;Kim Chul-Young;Choi Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.85-91
    • /
    • 2000
  • Purpose : The aim of this study is to look for the possible efficacy of postoperative external irradiation for incompletely resected meningiomas. Methods and Materials : From August 198: to January 1997, forty-four patients with intracranial meningioma were treated by postoperative external irradiation. Of the 44 meningiomas, 18 transitional, 13 meningotheliomatous, 6 hemangiopericytic, 4 atypical, 2 fibroblastic and 1 malignant meningioma were identified. We classified all patients into two groups by the histology. The benign group was consisted of the meningotheliomatous, transitional and fibroblastic types. The malignant group was consisted of the atypical, hemangiopericytic and malignat types. In the means of surgery, 37 patients were resected incompletely and 7 patients were managed by biopsy only. After surgery, all patients were received postoperative external irradiation. Radiotherapy was deliverd using Co-60 or 4 MV photon beam to a total dose of 50 to 65 Gy (mean dose 57.4 Gy) with a 1.8 to 2 Gy per fraction. The median follow-up was 48 months (range : 21 $\~$ 101 months). Multivariate analysis of the Influence by age, sex, location, histology and radiation dose on local control has been done using Cox's proportional hazard model. Results : 5-year local control rate was 93.8$\%$ for the benign histology and 51.8$\%$ for the malignant histology (p=0.0110) and overall local control rate at 5 years was 87.4$\%$. The analysis of the prognostic factors, such as age, sex, location, and radiation dose were not significant except for the histology. Conclusion : Adjuvant postoperative external irradiation appears to be significantly improved local control in the patients with incompletely resected meningiomas.

  • PDF

Long-term Results of Radiotherapy for Subfoveal Choroidal Neovascularization (CNV) in Age-related Macular Degeneration (ARMD) (연령관련 황반하 맥락막 신생혈관증에서 방사선의 장기적 치료 결과)

  • Kim, Bo-Kyong;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.63-69
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: We performed this prospective randomized study to evaluate the efficacy and the complications of radiotherapy for Subfoveal CNV in ARMD and to compare the treatment results at two dosages (14.4 Gy and 19.8 Gy). $\underline{Materials\;and\;Methods}$: 60 eyes of 55 patients were enrolled, and randomized into 14.4 Gy (31 eyes) or 19.8 Gy (29 eyes) groups. CT was used to plan the radiotherapy. All patients received radiotherapy with a 1.8 Gy daily dose using 4 MV photon. We categorized treatment results as improved, stable, or deteriorated based on visual acuity changes of more than 2 lines on the ETDRS chart. $\underline{Results}$: Median follow-up period was 33.5 months. At 12 months, visual acuity improved in 9 (16.7%), stable in 41 (75.9%), and aggravated in 4 (7.4%) of 54 evaluated eyes. At 24 months, 49 eyes (81.7%) were evaluated. Visual acuity improved in 6 (12.2%), was stable in 33 (67.4%), and deteriorated in 10 (20.4%). At 36 months, 37 eyes were evaluated. Six (16.2%) eyes were improved, 21 (56.8%) stable, and 10 (27.0%) deteriorated. No significant difference in response was observed between the 14.4 Gy and 19.8 Gy groups (Mantel-Haenszel $x^2=0.4756$). The proportion of eyes with a vision of $20/100{\leq}increased$ from 28.3% initially to 32.7% after 24 months of radiotherapy. There were no severe acute or chronic complications. $\underline{Conclusion}$: External beam radiotherapy with doses of 14.4 or 19.8 Gy may be an effective treatment for subfoveal CNV in ARMD. No dose-response relationships with respect to treatment response or toxicity were observed between the 14.4 Gy and 19.8 Gy groups.

Radiation Therapy in Elderly Skin Cancer (노령의 피부암에서 방사선치료)

  • Kim, Jin-Hee
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.113-117
    • /
    • 2008
  • Purpose: To evaluate the long term results(local control, survival, failure, and complications) after radiation therapy for skin cancer in elderly patients. Material and Methods: The study spanned from January 1990 to October 2002. Fifteen elderly patients with skin cancer were treated by radiotherapy at the Keimyung University Dongsan Medical Center. The age distribution of the patients surveyed was 72 to 95 years, with a median age of 78.8 years. The pathologic classification of the 15 patients included squamous cell carcinoma(10 patients), basal cell carcinoma(3 patients), verrucous carcinoma(1 patient) and skin adnexal origin carcinoma(1 patient). The most common tumor location was the head(13 patients). The mean tumor diameter was 4.9 cm(range 2 to 9 cm). The radiation dose was delivered via an electron beam of 6 to 15 MeV. The dose range was adjusted to the tumor diameter and depth of tumor invasion. The total radiation dose ranged from $50{\sim}80$ Gy(mean: 66 Gy) with a 2 Gy fractional dose prescribed to the 80% isodose line once a day and 5 times a week. One patient with lymph node metastasis was treated with six MV photon beams boosted with electron beams. The length of the follow-up periods ranged from 10 to 120 months with a median follow-up period of 48 months. Results: The local control rates were 100%(15/15). In addition, the five year disease free survival rate(5YDFS) was 80% and twelve patients(80%) had no recurrence and skin cancer recurrence occurred in 3 patients(20%). Three patients have lived an average of 90 months($68{\sim}120$ months) without recurrence or metastasis. A total of 9 patients who died as a result of other causes had a mean survival time of 55.8 months after radiation therapy. No severe acute or chronic complications were observed after radiation therapy. Only minor complications including radiation dermatitis was treated with supportive care. Conclusion: The results suggest that radiation therapy is an effective and safe treatment method for the treatment of skin cancer in elderly patients who achieved a good survival rate and few minor complications.

Neoadjuvant Chemotherapy and Radiotherapy in Locally Advanced Hypopharyngeal Cancer (국소 진행된 하인두암의 선행 항암화학요법 후 방사선치료)

  • Kim Suzy;Wu Hong-Gyun;Heo Dae-Seog;Park Charn I1
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.244-250
    • /
    • 2000
  • Purpose : To see the relationship between the response to chemotherapy and the final outcome of neoadiuvant chemotherapy and radiotherapy in patients with mocanry advanced hypopharyngeal cancer. Methods and Materials :A retrospective analysis was done for thirty-two patients with locally advanced hypopharyngeal cancer treated in the Seoul National University Hospital with neoadiuvant chemotherapy and radiotherapy from August 1979 to July 1997. The patients were treated with Co-60 teletherapy unit or 4MV or 6MV photon beam produced by linear accelerator. Daily fractionation was 1.75 to 2 Gy, delivered five times a week. Total dose ranged from 60.8 Gy to 73.8 Gy. Twenty-nine patients received continuous infusion of cisplatin and 5-FU. Other patients were treated with cisplatin combined with bleomycin or vinblastin. Twenty-four (75$\%$) patients received all three prescribed cycles of chemotherapy delivered three weeks apart. Six patients received two cycles, and two patients received only one cycle. Results :The overall 2-year and 5-year survival rates are 65.6$\%$ and 43.0$\%$, respectively. 5-year local control rate is 34$\%$. Organ preservation for more than five years is achieved in 12 patients (38$\%$). After neoadjuvant chemotherapy, 24 patients achieved more than partial remission (PR): the response rate was 75$\%$ (24/32). Five patients had complete remission (CR), 19 patients PR, and 8 patients no response (NR). Among the 19 patients who had PR to chemotherapy, 8 patients achieved CR after radiotherapy. Among the 8 non-responders to chemotherapy, 2 patients achieved CR, and 6 patients achieved PR after radiotherapy. There was no non-responder after radiotherapy. The overall survival rates were 60$\%$ for CR to chemotherapy group, 35.1$\%$ for PR to chemotherapy group, and 50$\%$ for NR to chemotherapy group, respectively (p=0.93). There were significant difference in five-year overall survival rates between the patients with CR and PR after neoadjuvant chemotherapy and radiotherapy (73.3$\%$ vs. 14.7$\%$, p<0.01). The prognostic factor affecting overall survival was the response to overall treatment (CR vs. PR, p<0.01). Conclusion :In this study, there were only five patients who achieved CR after neoadiuvant chemotherapy. Therefore the difference of overall survival rates between CR and PR to chemotherapy group was not statistically significant. Only the response to chemo-radiotherapy was the most important prognostic factor. There needs to be more effort to improve CR rate of neoadjuvant chemotherapy and consideration for future use of concurrent chemoradiotherapy.

  • PDF

Study on the calibration phantom and metal artifacts using virtual monochromatic images from dual energy CT (듀얼 에너지 CT의 가상 단색 영상을 이용한 영상 교정 팬텀과 금속 인공음영에 관한 연구)

  • Lee, Jun seong;Lee, Seung hoon;Park, Ju gyung;Lee, Sun young;Kim, Jin ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.77-84
    • /
    • 2017
  • Purpose: To evaluate the image quality improvement and dosimetric effects on virtual monochromatic images of a Dual Source-Dual Energy CT(DS-DECT) for radiotherapy planning. Materials and Methods: Dual energy(80/Sn 140 kVp) and single energy(120 kVp) scans were obtained with dual source CT scanner. Virtual monochromatic images were reconstructed at 40-140 keV for the catphan phantom study. The solid water-equivalent phantom for dosimetry performs an analytical calculation, which is implemented in TPS, of a 10 MV, $10{\times}10cm^2$ photon beam incident into the solid phantom with the existence of stainless steel. The dose profiles along the central axis at depths were discussed. The dosimetric consequences in computed treatment plans were evaluated based on polychromatic images at 120 kVp. Results: The magnitude of differences was large at lower monochromatic energy levels. The measurements at over 70 keV shows stable HU for polystyrene, acrylic. For CT to ED conversion curve, the shape of the curve at 120 kVp was close to that at 80 keV. 105 keV virtual monochromatic images were more successful than other energies at reducing streak artifacts, which some residual artifacts remained in the corrected image. The dose-calculation variations in radiotherapy treatment planning do not exceed ${\pm}0.7%$. Conclusion: Radiation doses with dual energy CT imaging can be lower than those with single energy CT imaging. The virtual monochromatic images were useful for the revision of CT number, which can be improved for target coverage and electron densities distribution.

  • PDF

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

The Analyses of Treatment Results and Prognostic Factors in Supradiaphragmatic CS I-II Hodgkin's Disease (횡경막상부에 국한된 임상적 병기 1-2기 호지킨병에서 치료 결과와 예후 인자의 분석)

  • Park Won;Suh Chang Ok;Chung Eun Ji;Cho Jae Ho;Chung Hyun Cheol;Kim Joo Hang;Roh Jae Kyung;Hahn Jee Sook;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.147-157
    • /
    • 1998
  • Purpose : The aim of this retrospective study is to assess the necessity of s1aging laparotomy in the management of supradiaphragmatic CS I-II Hodgkin's disease. Prognostic factors and the usefulness of prognostic factor groups were also analyzed. Materials and Methods : From 1985 to 1995, fifty one Patients who were diagnosed as supradiaphragmatic CS I-II Hodgkin's disease at Yonsei Cancer Center in Seoul, Korea were enrolled in this study Age range was 4 to 67 with median age of 30. The number of patients with each CS IA, II A, and IIB were 16, 25, and 10, respectively. Radiotherapy(RT) was delivered using 4 or 6 MV photon beam to a total dose of 19.5 to 55.6Gy (median dose : 45Gy) with a 1.5 to 1.BGy per fraction. Chemotherapy(CT) was given in 2-12 cycles(median : 6 cycles). Thirty one Patients were treated with RT alone, 4 patients with CT alone and 16 patients with combined chemoradiotherapy. RT volumes varied from involved fields(3), subtotal nodal fields(18) or mantle fields(26). Results : Five-year disease-free survival rate(DFS) was $78.0\%$ and overall survival rate(05) was $87.6\%$. Fifty Patients achieved a complete remission after initial treatment and 8 patients were relapsed. Salvage therapy was given to 7 patients, 1 with RT alone, 4 with CT alone, 2 with RT+CT. Only two patients were successfully salvaged. Feminine gender and large media-stinal adenopathy were significant adverse prognostic factors in the univariate analysis for DFS. The significant adverse prognostic factors of OS were B symptom and clinical stage. When patients were analyzed according to European Organization for Research and Treatment of Cancer(EORTC) prognostic factor groups, the DFS in Patients with very favorable, favorable and unfavorable group was 100, 100 and $55.8\%$(p<0.05), and the 05 in each patients' group was 100, 100 and $75.1\%$(p<0.05), respectively. In very favorable and favorable groups, the DFS and 05 were all $100\%$ by RT alone, but in unfavorable group, RT with CT had a lesser relapse rate than RT alone. The subtotal nodal irradiation had better OFS than mantle RT in patients treated with RT. Conclusion : In present study, the DFS and OS in patients who did not undergo s1aging laparotomy were similar with the results in the literatures of which patients were surgically staged. Therefore, we may suggest that staging laparotomy would not influence the outcome of treatments. In univariate analysis, gender, large mediastinal adenopathy. B symptoms and clinical stage were significant prognostic factors for the survival rate. We confirm the usefulness of EORTC prognostic factor groups which may be a good.

  • PDF