• 제목/요약/키워드: MV XLPE Cable

검색결과 13건 처리시간 0.026초

A Study on the Design of a Planar Loop Sensor for Partial Discharge Diagnosis of 22.9 kV XLPE Power Cables

  • Lim, Kwang-Jin;Yang, Sang-Hyun;Shin, Dong-Hoon;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.559-565
    • /
    • 2008
  • This study designed a new type of loop antenna that is able to detect partial discharges based on microstrip line technology. In the diagnosis of power cables, partial discharge signals are generally produced at a frequency range less than 100MHz because high frequency PD signals are lost along a propagation path in such cables. The new type of loop antenna sensor has been studied using simulation software known as CST microwave studio version 5.0. In partial discharge measurement experiments, a commercial HFCT sensor was used as a reference sensor. Several experiments were made over HFCT and loop antenna sensors for detecting partial discharges on 22.9kV MV XLPE cable. In this study, we showed the loop antenna designed in this study that can be applied as a commercial HFCT sensor.

Non-conventional 센서를 이용한 MV급 전력케이블의 부분방전 측정 (Partial Discharges Detection for MV Cables using Non-conventional Sensors)

  • 김종열;이영조;조성주;남정학;구자윤;김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1604-1605
    • /
    • 2011
  • This paper deals with the partial discharge detection in order to recognize with three different nature of artificial defects using non-conventional HF-VHF PD sensor of which two measuring position are chosen along the 22.9kV XLPE power cable specimen. The response of the sensor under investigation has been observed be significantly affected by the cable length from the PD sources. As a result, it seems that the detecting sensor position is very important for the analysis of the nature of PD source. Moreover, it could be suggested that any standardized calibration method should be established replacing IEC 60270 as far as any type of non-conventional sensors are concerned.

  • PDF

KEPCO의 지중배전케이블 열화진단기술 적용 방향 (Overview of MV Cable Diagnostic System for KEPCO)

  • 권태준;김성민;김병석;이재봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2093-2094
    • /
    • 2011
  • 가교폴리에틸렌(XLPE) 절연체를 적용한 MV급 지중케이블은 1972년부터 KEPCO에서 본격적으로 사용되기 시작하였다. 이후 도심지 지중화사업에 힘입어 매년 6.5%정도의 케이블 설비가 증가하였으며 오늘날 29,000C-km이상의 MV급 케이블이 설치되어 있다. 과거 비약적인 경제성장과 더불어 전력망 확충을 위한 투자가 KEPCO의 주된 역할이었다면 오늘날에 있어서는 확충된 설비를 최적의 상태로 유지 관리하는 것으로 패러다임이 변하고 있다. 특히 지중설비의 동맥(動脈)으로 볼 수 있는 케이블에 대한 관리방법이 화두가 되고 있으며 최적관리의 전제조건인 열화진단 분야가 KEPCO가 이끌고 나가야 할 새로운 개척분야로써 많은 역량이 집중되고 있다. 2010년에는 VLF TD/PD를 새로운 진단기법으로 적용하였으며 케이블 설치공사 준공 검수시험으로 0.1Hz 저주파 교류내전압시험 도입 및 활선 PD진단장치를 자체 개발하여 현장 적용성 검토를 추진하는 등 MV급 지중설비의 관리기법에 있어 큰 전환점을 만들고 있다. 본 고에서는 KEPCO의 MV급 케이블 변천사와 추진하고 있는 진단기법 및 관리 지향점을 논하고자 한다.