공간필터에 의한 운동단위 활동전위의 분해능 향상에 관한 연구 (A Study on Improvement of MUAP Resolution using Spatial Filter)

  • 양덕진;전창익;이영석;이진;김성환
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권1호
    • /
    • pp.55-64
    • /
    • 2004
  • Conventional bipolar surface electromyography(EMG) technique detects only the superimposed electromyographic activity of a large number of motor units due to its low spatial resolution. For the diagnosis of neuromuscular disorder, the information of single MU is required. In this paper, 9 channel array surface electrode system was as designed and MLoG filter was proposed. Also the MCPT(modified convolution processing technique)method was proposed for the improvement of MUAP resolution. For performance evaluation, power spectrum analysis of random data and raw EMG signal comparison of MUAP shape and quantitative estimation of SNR were executed. As a result, the MUAP resolution improvement of 32% was obtained from the standpoint of the signal-to-noise ratio(SNR).

주파수 템플릿 정합법을 사용한 EMG 신호 분해 (The Decomposition of EMG signals using Template Matiching Method in the frequency domain)

  • 박세훈;이영우;고현운;예수영;엄상희;남기곤;전계록
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.55-58
    • /
    • 1997
  • In this paper, we study a signal processing method which extracts each MUAP(motor unit action potential) from EMG(Electromyogram) interference pattern or clinical diagnostic purposes. First of all, differential digital filtering is selected or eliminating the spike components of the MUAP's from the background noise. And, the algorithm identifies the spikes over the certanin threshold by template matching in frequency domain. After missing or false firing actor is cut off at the IPI(inter pulse interval) histogram, we averages the MUAP waveforms from the raw signal using the identified spikes as triggers, and Finally, measures their amplitudes, durations, and numbers of phases. Specially, We introduce algorithm performed by template matching in the frequency domain. A typical 3-s signal recorded from the biceps brachii muscle using a conventional needle electrode during a isometric contraction is used. Finally, the method decomposed five simultaneous active MUAP's from original EMG signal.

  • PDF

웨이브렛 필터를 이용한 복합 중첩 근신호의 최적화 분리 알고리즘 (An Algorithm for the Optimum Separation of Superimposed EMG Signal Using Wavelet Filter)

  • 이영석;김성환
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권3호
    • /
    • pp.319-326
    • /
    • 1996
  • Clinical myography(EMG) is a technique for diagnosing neuromuscular disorders by analyzing the electrical signal that can be records by needle electrode during a muscular contraction. The EMG signal arises from electrical discharges that accompany the generation of force by groups of muscular fiber, and the analysis of EMG signal provides symptoms that can distinguish disorder of mLecle from disor- ders of nerve. One of the methods for analysis of EMG signal is to separate the individual discharge-the motor unit action potentials(MVAPS) - from EMG signal. But we can only observe the EMG signal that is a superimposed version of time delayed MUAPS. To obtain the information about MUAP(, i.e., position, firing number, magnitude etc), first of all, a method that can separate each MUAP from the EMG signal must be developed Although the methods for MUAP separation have been proposed by many researcherl they have required heavy computational burden. In this paper, we proposed a new method that has less computational burden and performs more reliable separation of superimposed EMG signal using wavelet filter which has multiresolution analysis as major property. As a result, we develope the separation algorithm of superimposed EMG signal which has less computational burden than any other researchers and exacutes exact separation process. The performance of this method has been discussed in the automatic resolving procedure which is neccessary to identify every firing of every motor unit from the EMG pattern.

  • PDF

표면 운동단위 활동전위 스파이크 검출을 위한 최적의 디지털 저역통과 미분기 선정 방법 (A Selection Method of Optimal Digital Low-pass Differentiator for Spike Detection of Surface Motor Unit Action Potential)

  • 이진;김성환
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1951-1958
    • /
    • 2011
  • The objective of this study is to analyze the performance of digital low-pass differentiators(LPD) and then to provide a method to select effective LPD filter, for detecting spikes of surface motor unit action potentials(MUAP). The successful spike detection of MUAPs is a first important step for EMG signal decomposition. The performances of simple and weighted LPD(SLPD and WLPD) filters are analyzed based on different filter lengths and varying MUAPs from simulated surface EMG signals. The SNR improving coefficient and effective MUAP duration range from the analysis results can be used to select proper LPD filters under the varying conditions of surface EMG.

일측성 성대 마비에서 운동단위 활동전위를 이용한 정량적 후두 근전도 분석 (Quantitative Measurement of Laryngeal Electromyography Using Motor Unit Action Potential in Unilateral Vocal Cord Paralysis)

  • 하륜;김동영;김동현;우주현
    • 대한후두음성언어의학회지
    • /
    • 제30권1호
    • /
    • pp.28-33
    • /
    • 2019
  • Background and Objectives : Laryngeal electromyography (LEMG) is valuable to evaluate the innervation status of the laryngeal muscles and the prognosis of vocal fold paralysis (VFP). However, there is a lack of agreement on quantitative interpretation of LEMG. The aim of this study is to measure the motor unit action potentials (MUAP) quantitatively in order to find cut-off values of amplitude, duration, phase for unilateral vocal fold paralysis patients. Materials and Method : Retrospective chart review was performed for the unilateral VFP patients who underwent LEMG from March 2016 to May 2018. Patient's demography, cause of VFP, vocal cord mobility, and LEMG finding were analyzed. The difference between normal and paralyzed vocal folds and cut-off values of duration, amplitude, and phase in MUAP were evaluated. Results : Thirty-six patients were enrolled in this study. Paralyzed vocal fold had significantly longer duration (p=0.021), lower amplitude (p=0.000), and smaller phase (p=0.012) than the normal. The cut-off values of duration, amplitude, and phase in MUAP for unilateral VFP were 5.15 ms, $68.35{\mu}V$, and 1.85 respectively. Conclusion : An analysis of MUAP successfully provided quantitative differences between normal and paralyzed vocal folds. But, additional research is needed to get more available cut-off value which is helpful to evaluate the status of laryngeal innervations.

표면 근전도 신호 피이크 검출을 위한 디지털 분수 차수 저역통과 미분기 (Digital Fractional Order Low-pass Differentiators for Detecting Peaks of Surface EMG Signal)

  • 이진;김성환
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.1014-1019
    • /
    • 2013
  • Signal processing techniques based on fractional order calculus have been successfully applied in analyzing heavy-tailed non-Gaussian signals. It was found that the surface EMG signals from the muscles having nuero-muscular disease are best modeled by using the heavy-tailed non-gaussian random processes. In this regard, this paper describes an application of digital fractional order lowpass differentiators(FOLPD, weighted FOLPD) based on the fractional order calculus in detecting peaks of surface EMG signal. The performances of the FOLPD and WFOLPD are analyzed based on different filter length and varying MUAP wave shape from recorded and simulated surface EMG signals. As a results, the WFOLPD showed better SNR improving factors than the existing WLPD and to be more robust under the various surface EMG signals.

독립성분 분석과 신전달 모델을 이용한 근육의 미세한 힘의 추정에 관한 연구 (A Study on the Low Force Estimation of Skeletal Muscle by using ICA and Neuro-transmission Model)

  • 유세근;염두호;이호용;김성환
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.632-640
    • /
    • 2007
  • The low force estimation method of skeletal muscle was proposed by using ICA(independent component analysis) and neuro-transmission model. An EMG decomposition is the procedure by which the signal is classified into its constituent MUAP(motor unit action potential). The force index of electromyography was due to the generation of MUAP. To estimate low force, current analysis technique, such as RMS(root mean square) and MAV(mean absolute value), have not been shown to provide direct measures of the number and timing of motoneurons firing or their firing frequencies, but are used due to lack of other options. In this paper, the method based on ICA and chemical signal transmission mechanism from neuron to muscle was proposed. The force generation model consists of two linear, first-order low pass filters separated by a static non-linearity. The model takes a modulated IPI(inter pulse interval) as input and produces isometric force as output. Both the step and random train were applied to the neuro-transmission model. As a results, the ICA has shown remarkable enhancement by finding a hidden MAUP from the original superimposed EMG signal and estimating accurate IPI. And the proposed estimation technique shows good agreements with the low force measured comparing with RMS and MAV method to the input patterns.

A MODEL FOR MYOELECTRIC SIGNAL WITH LOCALIZED MUSCLE FATIGUING

  • Lee, Y.S.;Jeon, C.J.;Lee, S.H.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제7권1호
    • /
    • pp.79-86
    • /
    • 2003
  • A myoelectric signal, under sustained isometric contraction of muscle the modelled as the output of a linear time-varying system whose input is constant number of pulse train. The proposed model considered localized muscle fatigue by metabolic by-products during sustained fatiguing contraction. To characterize muscle fatiguing model of myoelectric signal, We calculated median frequency of generated signal as fatiguing index of muscle during sustained isometric contraction.

  • PDF

표면 근전도를 이용한 이두박근의 운동단위 위치 추정에 관한 연구 (A Study on Estimation of Motor Unit Location of Biceps Brachii Muscle using Surface Electromyogram)

  • 박중호;이호용;정철기;이진;김성환
    • 전자공학회논문지SC
    • /
    • 제47권3호
    • /
    • pp.28-39
    • /
    • 2010
  • 본 논문에서는 표면 근전도(surface electromyogram, SEMG)를 이용하여 운동단위(motor unit, MU)의 위치(location)를 추정하는 새로운 방법을 제안하였다. 운동단위의 위치에 따라 운동단위 활동전위(motor unit action potential, MUAP), 나아가서는 표면 근전도의 크기(amplitude)가 변화하므로 운동단위의 위치 추정은 근력 추정에 있어서 중요하다. 제안된 방법은 표면근전도 시뮬레이션을 통해 취득한 기준 신호와 3 채널 표면전극을 이용하여 검출한 표면 근전도 신호를 비교하여 운동단위의 위치를 추정하는 방법이다. 운동단위 위치 추정의 정확도를 파악하기 위하여 컴퓨터 시뮬레이션을 통하여 취득한 MUAP를 본 연구에서 제안한 방법 및 기존 방법들을 적용하여 확인하였다. 시뮬레이션 결과 8[mm] 위치에 운동단위가 위치할 경우 본 논문에서 제안한 운동단위 위치 추정 방법은 0.01[mm]의 평균 추정 오차를 보였다. 반면에 Roeleveld가 제안한 추정 방법은 2.33[mm]의 평균 추정 오차를 보였으며 Akazawa가 제안한 추정 방법은 1.70[mm]의 평균 추정 오차를 보여 본 연구에서 제안한 운동단위 위치 추정 방법이 기존의 방법들에 비하여 더 정확한 위치 추정이 가능하였다.

근위축성 측상경화증 환자에서 등세모근의 신경생리학적 검사 (The Electrophysiological Studies of the Trapezius Muscle in Patients with Amyotrophic Lateral Sclerosis)

  • 조중양;전종은;이광우
    • Annals of Clinical Neurophysiology
    • /
    • 제6권2호
    • /
    • pp.85-91
    • /
    • 2004
  • Background: Needle electromyography (EMG) and motor evoked potential (MEP) of the genioglossus (tongue) are difficult to perform in evaluations of the craniobulbar region in amyotrophic lateral sclerosis (ALS). Therefore, we investigated the yields of needle EMG and MEP recorded from the upper trapezius, since it receives innervation from the lower medulla and upper cervical cord. Methods: Needle EMG and MEP of the upper trapezius were obtained in 17 consecutive ALS patients. The needle EMG parameters recorded included abnormal spontaneous activity and motor unit action potential (MUAP) morphology. An upper motor neuron (UMN) lesion was presumed when either response to cortical stimulation was absent, or the central conduction time was delayed (>mean+2SD). Results: Of the five patients with bulbar-onset ALS, four had abnormalities in the upper trapezius and four in the tongue by needle EMG. In contrast, of the 12 patients with limb-onset ALS, 11 had abnormalities in the upper trapezius, and only five in the tongue. When MEP was performed, it was found that three of the five patients with bulbar symptoms and three of the six patients with isolated limb involvement had abnormal MEP findings. Conclusions: Electrophysiological studies of the upper trapezius are more sensitive those of the tongue in patients without bulbar symptoms. Thus, needle EMG and MEP of the upper trapezius are alternative tools for assessing bulbar and rostral neuraxial involvement in the diagnosis of ALS.

  • PDF