• 제목/요약/키워드: MTF1

검색결과 205건 처리시간 0.028초

방사선치료의 다양한 EPID 영상 질평가 (Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy)

  • 손순룡;최관우;김정민;정회원;권경태;조정희;이제희;정재용;김기원;이영아;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.451-461
    • /
    • 2015
  • MV방사선 치료는 둘러싸여 있는 정상조직의 피폭선량을 최소화 하면서, target volume 내에 정확하게 선량을 전달하는데 있어 중요한 요인이다. 본 연구에서는 방사선 치료의 높은 정확성을 유지하기 위하여 megavoltage X-ray imaging (MVI)에서 edge block 을 사용한 digital radiography (DR) system 검출기의 modulation transfer function (MTF: 변조전달함수), the noise power spectrum (NPS: 잡음전력스펙트럼) and the detective quantum efficiency (DQE: 양자검출효율)를 측정하고자 한다. 우리는 텅스텐으로 구성된 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$의 edge block을 사용하였으며, 다음과 같은 setting들로 pre-sampling modulation transfer function (MTF)를 계산하였다: 6-megavolt (MV) energy를 사용하고, 다양한 Radiotherapy장비인 TrueBeamTM (Varian), BEAMVIEWPLUS (Siemens), iViewGT (Elekta), ClinacR iX (Varian) 를 사용하였다. MTF결과에서 Varian TrueBeamTM flattening filter free가 MTF의 50% ($mm^{-1}$)에서 0.46, 10% ($mm^{-1}$) 에서 1.40로 가장 highest value를 보였다. Noise 분포는 Elekta iViewGT가 가장 낮은 분포를 보였다. DQE에서는 E lekt a iViewGT가 peak DQE에서 0.0026 그리고 $1mm^{-1}$ DQE 에서 0.00014로 가장 높았다. 본 연구는 Edge method를 이용하여 MTF와 DQE산출을 재현하였으며, 현재 임상에서 사용되는 DR 시스템 측정의 높은 정확성을 유지할 수 있었으며 이러한 연구는 전통적인 QA 영상화뿐만 아니라 검출기 개발 연구에 있어서 정량적인 MTF, NPS, DQE 측정에 더욱 더 효율적으로 사용될 수 있다는 것을 알 수 있다.

적외선 광학계용 MTF 측정장치 개발 (Development of a MTF Measurement System for an Infrared Optical System)

  • 손병호;이회윤;송재봉;양호순;이윤우
    • 한국광학회지
    • /
    • 제26권3호
    • /
    • pp.162-167
    • /
    • 2015
  • 본 논문에서는 적외선 파장대에서 렌즈의 변조전달함수(MTF)를 칼날 주사방식으로 측정하는 적외선 MTF 측정장치를 구성하고 평가하였다. 측정장치는 물체부, 평행광을 만들어주는 시준부, 형성된 상을 분석하는 분석부로 나뉜다. 광원으로는 텅스텐 필라멘트 광원을 사용하였으며 중적외선 영상을 검출하기 위해 MCT를 사용하였다. 이 장치를 사용하여 ZnSe 재질의 f 수가 5인 표준렌즈의 MTF를 중적외선 파장대인 $3{\sim}5{\mu}m$에서 측정하고 Zemax 프로그램을 통해 계산한 이론값과 측정값 차이를 비교하여 차단주파수(Cut-off frequency)인 50 1/mm까지 전구간에서 ${\pm}0.035$이내임을 확인하였다. 또한 측정값의 신뢰도를 확인하기 위한 A형 측정불확도를 계산한 결과 MTF의 대표 공간 주파수인 20 1/mm에서 0.002으로 동일한 조건 하에서 측정 시 측정값의 변화가 거의 없음을 알 수 있었다.

볼록 검안렌즈의 MTF 성능 분석 및 이론적 해석에 대한 연구 (A Study on Assessment of MTF Performance and Theoretical Analysis of Convex Trial Lenses)

  • 방현진;이종웅;손병호;안교훈;최은정
    • 한국광학회지
    • /
    • 제24권5호
    • /
    • pp.217-223
    • /
    • 2013
  • 10 diopter에서 20 diopter까지의 양볼록 검안렌즈에 대한 백색광 MTF(Modulation Transter Function)를 각주파수와 시력으로 나타낸 후, 이들을 각각 AIM(Aerial Image Modulation) curve와 비교하였다. 축상시야에서 평가된 양볼록 검안렌즈 모두 시력 2.0까지는 란돌트 링을 분해할 수 있는 MTF를 가지고 있었다. 하지만 반시야각 $5.0^{\circ}$인 비축시야에서는 10 diopter의 검안렌즈는 시력 0.9, 20 diopter의 검안렌즈는 0.8까지 란돌트 링을 분해할 수 있는 것으로 평가되어 시력을 1.0까지 측정하기에는 충분한 해상력을 가지지 못한 것으로 평가되었다.

경로길이 불일치 간섭계를 이용한 대구경 광학계의 MTF 측정과 파면오차 검사 (MTF and wavefront error testing of large aperture optical system using unequal path interferometer)

  • 송종섭;조재흥;이윤우;송재봉;양호순;이인원
    • 한국광학회지
    • /
    • 제16권1호
    • /
    • pp.50-55
    • /
    • 2005
  • 기준광과 탐사광의 경로길이가 매우 크게 차이가 나는 경로길이 불일치 간섭계(unequal path interferometer)를 이용한 직경 300mm 카세그레인 형태의 인공위성 망원경과 같은 대구경 광학계의 변조전달함수(modulation transfer function : MTF)와 파면오차를 동시에 측정하는 방법을 제안하고 이를 실험적으로 확인하였다. 이러한 경로불일치 간섭계를 이용한 측정시스템에서 필요한 평행한 시준광을 만들기 위해서 쌍방향 층밀리기 간섭계를 사용하였으며, 파면오차를 측정하기 위해서 직경 400 mm인 비축 포물경을 사용하는 긴 광경로차의 대구경 피조우 간섭계를 사용하였다. 또한 회전하는 확산판을 이용하여 레이저 광을 부분가간섭광으로 바꿈으로써 피조우 간섭계의 파장으로부터 쉽게 MTF를 측정할 수 있었다.

MTF-STI를 이용한 유리창 도청음의 명료도 분석 (Intelligibility Analysis on the Eavesdropping Sound of Glass Windows Using MTF-STI)

  • 김희동;김윤호;김석현
    • 한국음향학회지
    • /
    • 제26권1호
    • /
    • pp.8-15
    • /
    • 2007
  • 음향 공동-유리창 연성계를 대상으로 도청음의 음성 명료도를 검토한다. MLS신호를 음원으로 유리창의 가속도와 속도 응답을 가속도계와 레이저 도플러 진동계를 사용하여 측정한다. 변조전송함수 (MTF)를 사용하여 공동-유리창 진동계의 음성전달특성을 규명한다. 변조전송함수에 근거하여 음성전송지수 (STI)를 구하고, 유리창 진동음의 음성명료도를 평가한다. 가속도음과 속도음의 음성명료도를 비교하고, 최종적으로 대화음의 명료도를 주관적 평가로 확인한다.

변조전달함수 방법에서 엣지 장치 설정에 대한 각도 최적화 평가 (Evaluation of Angle Optimization on Edge Test Device Setting in Modulation Transfer Function)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권1호
    • /
    • pp.15-21
    • /
    • 2020
  • This study was purpose to evaluation of Modulation Transfer Function in Measurements by using the International electrotechnical commission standard(IEC 62220-1) which were edge device each angle by using edge method. In this study was Aero(Konica, Japan) image receptor which is a indirect Flat panel detector(FPD) was used. The size of matrix 1994 × 2430 (14"× 17" inch) which performed 12 bit processing and pixel pitch is 175 ㎛. The results of shown as MTF measurements at IEC standard. The amount of data seemed reasonable and at an MTF value of 0.1 the spatial frequencies were 2.56 cycles/mm at an angle of 2.4°. MTF value of 0.5 the spatial frequencies were 1.32 cycles/mm at an angle of 2.4°. This study were to evaluate MTF by setting each angle 2.0°~2.8° degrees the most effective optimal edge angle and to suggest the quantitative methods of measuring by using IEC.

메트로놈을 이용한 Ottonello 촬영 기법 (Ottonello Projection Techniques using the Metronome)

  • 임인철;김창수
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.730-734
    • /
    • 2009
  • 본 연구는 경추 정면상 촬영에서 경추 7개를 모두 잘 볼 수 있는 Ottonello 촬영방법을 메트로놈을 이용하여 보다 체계적인 촬영방법과 더 좋은 영상을 얻기 위해 실험을 통해서 다음과 같은 결과를 얻을 수 있었다. 1. 물리적인 방법의 하나인 raw data을 이용하여 MTF를 구한 평가결과에서는 MTF를 0.5로 기준 했을때 구두설명은 1.2 LP/mm, Moderato-100 1.4 LP/mm, Allegro-138 1.6 LP/mm, Presto-184에서는 2.4 LP/mm로 Presto-184에 맞추어 검사한 영상이 선예도가 가장 높게 나타났다. 2. 주관적인 방법에서는 영상의학과 전문의를 통한 영상평가 결과로 구두설명을 통해 좋은 영상을 얻을 수 있었던 경우는 17%였으며, Moderato-100 15%, Allegro-138 18%, Presto-184에서는 50%로 Presto-184에서 가장 좋은 영상으로 평가 받았다. 결론적으로 현재 임상에서 Ottonello 촬영기법을 환자에게 메트로놈을 이용하여 촬영을 시행한다면 경추 정면상의 영상을 쉽게 얻을 수 있을 것이며, 이에 대한 결과로 재촬영 감소는 물론이고 이로 인한 환자방사 선피폭 감소, 환자검사 대기시간 단축, 재료 비용절감 등 모든 면에서 큰 도움을 줄 수 있는 효과를 얻게 될 것으로 기대된다.

컴퓨터단층검사에서 AAPM Phantom을 이용한 변조전달함수 평가 (Evaluation of the Modulation Transfer Function for Computed Tomography by Using American Association Physics Medicine Phantom)

  • 김기원;최관우;정회원;장서구;권경태;손순룡;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.193-198
    • /
    • 2016
  • 임상적으로 computed tomography (CT)에서 정기적인 quality assurance (QA)는 요구되는 사항이다. 본 논문에서는 CT 검사에서 공간분해능에 대해서 AAPM Phantom을 이용하여 정확한 성능 분석을 위해 변조전달함수를 평가하고자 한다. CT장비는 dual source somatom definition flash (siemens healthcare, forchheim, Germany), brilliance 64 (phili ps m edi cal system N etherlands), a qui li on 64 (toshiba m edi cal system, Japan)를 사용하였으며, l mage J (wayne rasband national institutes of health, USA)프로그램을 실행하여 변조전달함수의 측정 방법인 chart method를 이용하여 영상에 대해서 정량적인 평가방법을 시행하였다. 변조전달함수를 이용하여 평가한 결과, 공간주파수를 이용한 데이터 값이 높아짐에 따라 변조전달함수는 감소됨을 알 수 있었다. 그리고 CT 장비에서 변조전달함수는 공간주파수(50%)에 있어서는 0.58, $0.28\;0.59mm^{-1}$으로 나타났으며, 변조전달함수 공간주파수(10%)에 있어서는 1.63, $0.89\;1.21mm^{-1}$으로 나타났다. 본 연구에서는 chart method를 이용하여 변조전달함수의 공간해상력에 대한 특성을 확인하고, 정량적인 평가방안을 제시하였다는 점에서 학술적 의의를 둘 수 있다.

CR(Computed Radiography)에서 초점 크기와 디지털영상후처리에 따른 공간분해능의 정량적 분석 (Quantitative Analysis of Spatial Resolution for the Influence of the Focus Size and Digital Image Post-Processing on the Computed Radiography)

  • 성열훈
    • 디지털융복합연구
    • /
    • 제12권11호
    • /
    • pp.407-414
    • /
    • 2014
  • 본 연구의 목적은 컴퓨터 방사선영상에서 X-선 초점 크기와 디지털영상후처리에 따른 공간분해능을 정량적으로 분석하고자 하였다. 초점의 크기는 소초점(0.6 mm)와 대초점(1.2 mm)을 이용하였다. 공간분해능의 정량적 분석은 엣지 측정법의 변조전달함수(MTF)를 이용하였다. 디지털영상후처리는 다단계 이미지 대비 증폭 알고리즘을 이용하여 경계면 증강과 대조도 증강에 따른 50%와 10%의 MTF를 평가하였다. 그 결과 모든 초점에서 MTF 50%의 공간분해능이 대조도 증강보다 경계면 증강에서 유의하게 높았다. 또한 대초점에서 획득된 영상은 디지털영상처리를 통해 공간분해능이 향상되었다. 결론적으로 이러한 결과는 컴퓨터 방사선영상에서 골격계 및 흉부영상과 같은 고 공간분해능 임상영상을 얻기 위한 기초자료로 활용할 수 있다.

다색광전달함수를 사용한 컬러 LCD 모니터의 광학적 상평가법 (Image quality assessment of color LCD monitors by polychromatic modulation transfer function)

  • 송종섭;조재흥;홍성목;이윤우;양호순;조현모;이인원
    • 한국광학회지
    • /
    • 제16권1호
    • /
    • pp.63-70
    • /
    • 2005
  • 컬러 LCD(liquid crystal display) 모니터의 광학적 상에 대한 성능을 평가하기 위하여 LCD 모니터를 포함한 모든 광학계의 파장별 공간주파수 반응에 가중치를 부여한 진폭전달함수(modulation transfer function ; MTF)를 이용한 다색광전달함수(polychromatic modulation transfer function ; PMTF)를 제안한다. 서로 다른 진폭들을 갖는 적색(R), 녹색(G), 청색(B)의 3개의 막대형 LCD 단위물체를 이용한 컬러 LCD의 PMTF의 시뮬레이션 결과와 실험적 결과가 잘 일치하며, 이 결과 컬러 LCD의 결상성능은 단색으로 측정하는 MTF 및 가시광의 전파장대를 사용하는 백색광 MTF와는 다른 R, G, B의 3색에 대한 PMTF로 측정하늘 것이 보다 적절하다.