• Title/Summary/Keyword: MTF1

Search Result 205, Processing Time 0.021 seconds

Study of MTF Measure That Adopts a Fitting Curve for the Variable Angle of a Slant Target in Presampled MTF (Presampled MTF 기법에서 Slant Target의 다양한 각도에 대한 함수 Fitting이 적용된 MTF 측정기법에 관한 연구)

  • Choi, Siyoun;Kim, Junghwan;Kong, Hyunbae;Kim, Donghwan;Baek, Kyounghoon;Park, Ingu;Jeon, Hyowon;Lee, Kinam
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.310-316
    • /
    • 2022
  • In this paper, the difference in modulation transfer function (MTF) results according to the change in the angle of a slant target when measuring a presampled MTF was confirmed, and the difference was reduced by fitting the edge spread function graph obtained to reduce the error by the target's rotation. Due to the feature of the presampled MTF method, the spatial frequency changed due to the sensor's projected intensity being changed by the target's rotation, and it was confirmed that the difference in the MTF value occurred depending on the rotation angle of the target. In this paper, the MTF was calculated after fitting only one column of the acquired image. It was confirmed that the rotation error is smaller compared to the case of the presampled MTF method and this fitting method can be applied to a scene that contains various target angles, such as auto-focusing using the MTF.

MTF Assessment and Image Restoration Technique for Post-Launch Calibration of DubaiSat-1 (DubaiSat-1의 발사 후 검보정을 위한 MTF 평가 및 영상복원 기법)

  • Hwang, Hyun-Deok;Park, Won-Kyu;Kwak, Sung-Hee
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.5
    • /
    • pp.573-586
    • /
    • 2011
  • The MTF(modulation transfer function) is one of parameters to evaluate the performance of imaging systems. Also, it can be used to restore information that is lost by a harsh space environment (radioactivity, extreme cold/heat condition and electromagnetic field etc.), atmospheric effects and falloff of system performance etc. This paper evaluated the MTF values of images taken by DubaiSat-1 satellite which was launched in 2009 by EIAST(Emirates Institute for Advanced Science and Technology) and Satrec Initiative. Generally, the MTF was assessed using various methods such as a point source method and a knife-edge method. This paper used the slanted-edge method. The slantededge method is the ISO 12233 standard for the MTF measurement of electronic still-picture cameras. The method is adapted to estimate the MTF values of line-scanning telescopes. After assessing the MTF, we performed the MTF compensation by generating a MTF convolution kernel based on the PSF(point spread function) with image denoising to enhance the image quality.

Modulation Transfer Function Measurement of a Linear Charge Coupled Device Imager by Using a Knife-Edge Scanner (칼날주사방법에 의한 일차원 CCD의 MTF 측정)

  • 조현모;이윤우;이인원;이상태;이종웅
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.173-177
    • /
    • 1995
  • The scanning type modulation transfer function (MTF) measurement system of linear charge coupled device (CCD) imagers is fabricated and the MTF of a linear CCD imager is tested. Measured MTF values are very sensitive to small angle knife-edge skew within 1 degree and show different results in several wavelengths. The MTF of the linear CCD imager is measured in different color temperatures of a tungsten filament lamp and the MTF uniformity of ti,t eel) pixels is tested.tested.

  • PDF

Amino acid substitutions conferring cold-sensitive phenotype on the yeast MTF1 gene

  • Jang, Sei-Heon
    • Journal of Microbiology
    • /
    • v.35 no.3
    • /
    • pp.228-233
    • /
    • 1997
  • The MTF1 gene of Saccharomyces cerevisiae encodes a 43 kDa MITOCHONDRIAL RNA polymerase specificity factor which recognizes mitochondrial promoters to initiate correct transcription. To better understand structure-function of the MTF1 gene as well as the transcription mechanism of mitochondrial RNA polymerase, two cold-sensitive alleles of the MTF1 mutation were isolated by plasmid shuffling method after PCR-based random mutagenesis of the MTF1 gene. The mutation sites were analyzed by nucleotide sequencing. These cs phenotype mtf1 mutants were respiration competent on the nonfermentible glycerol medium at the permissive temperature, but incompetent at 13.deg.C. The cs phenotype allele of the MTF1, yJH147, encoded an L146P replacement. The other cs allele, yJH148, contained K179E and K214M double replacements. Mutations in both alleles were in a region of Mtflp which is located between domains with amino acid sequence similarities to conserved regions 2 and 3 of bacterial s factors.

  • PDF

Real time MTF Measurement of Copy Lenses by two-dimensional CCDs (2차원 CCD를 이용한 복사기 렌즈의 실시간 MTF 측정)

  • 조현모;이윤우;이인원;김태희;최옥식;이환규
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 1996
  • Charge-coupled device(CCD) array detectors are widely used in real time modulation transfer function(MTF) measurement systems. This paper presents the characteristics of two-dimensional CCDs used in a real time MTF measurement system for copy lenses. The MTF characteristics of a copy lens measured by this equipment show different results according to the direction of shift register, shutter speed and the amplifier gain of CCDs. An object generator is fabricated to reduce the variation of MTF values for the irradiance nonuniformity in on-axis and off-axis image plane and this MTF equipment is calibrated by using a standard lens.

  • PDF

Factors affecting modulation transfer function measurements in cone-beam computed tomographic images

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.131-137
    • /
    • 2019
  • Purpose: This study was designed to investigate the effects of voxel size, the oversampling technique, and the direction and area of measurement on modulation transfer function (MTF) values to identify the optimal method of MTF measurement. Materials and Methods: Images of the wire inserts of the SedentexCT IQ phantom were acquired, and MTF values were calculated under different conditions(voxel size of 0.1, 0.2, and 0.3 mm; 5 oversampling techniques; simulated pixel location errors; and different directions and areas of measurement). The differences in the MTF values across various conditions were evaluated. Results: The MTF 10 values showed smaller standard deviations than the MTF 50 values. Stable and accurate MTF values were obtained in the 0.1-mm voxel images. In the 0.3-mm voxel images, oversampling techniques of 11 lines or more did not show significant differences in MTF values depending on the presence of simulated location errors. MTF 10 values showed significant differences according to the direction and area of the measurement. Conclusion: To measure more accurate and stable MTF values, it is better to measure MTF 10 values in small-voxel images. In large-voxel images, the proper oversampling technique is required. MTF values from the radial and tangential directions may be different, and MTF values vary depending on the measured area.

Study on Practical MTF Budget of Satellite Electro-Optical Imaging System (위성 전자광학 결상계의 실용적 MTF 성능 지표)

  • 조영민
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.80-81
    • /
    • 2001
  • 우주에서 작동이 검증되었고 영상 품질이 잘 알려진 기존 위성 전자광학 결상계들의 MTF 특성을 분석하여 위성 전자광학 결상계 설계에서 실제로 적용될 수 있는 최적화된 MTF 성능 지표를 구하는 방법을 제시하였다. KOMPSAT-1 EOC와 IKONOS에 대해 이론적 한계가 잘 알려진 MTF 성분들인 광학회절한계 MTF와 Spatial 및 Temporal Sampling MTF를 분석하여 실용적인 MTF 성능 지표를 구하였고, 이 지표를 이용하여 몇 가지 광학계의 최소 구경을 추정하여 지표의 실용성을 검토하였다. (중략)

  • PDF

Molecular cloning of metal-responsive transcription factor-1 (MTF-1) and transcriptional responses to metal and heat stresses in Pacific abalone, Haliotis discus hannai

  • Lee, Sang Yoon;Nam, Yoon Kwon
    • Fisheries and Aquatic Sciences
    • /
    • v.20 no.7
    • /
    • pp.9.1-9.13
    • /
    • 2017
  • Background: Metal-responsive transcription factor-1 (MTF-1) is a key transcriptional regulator playing crucial roles in metal homeostasis and cellular adaptation to diverse oxidative stresses. In order to understand cellular pathways associated with metal regulation and stress responses in Pacific abalone (Haliotis discus hannai), this study was aimed to isolate the genetic determinant of abalone MTF-1 and to examine its expression characteristics under basal and experimentally stimulated conditions. Results: The abalone MTF-1 shared conserved features in zinc-finger DNA binding domain with its orthologs; however, it represented a non-conservative shape in presumed transactivation domain region with the lack of typical motifs for nuclear export signal (NES) and Cys-cluster. Abalone MTF-1 promoter exhibited various transcription factor binding motifs that would be potentially related with metal regulation, stress responses, and development. The highest messenger RNA (mRNA) expression level of MTF-1 was observed in the testes, and MTF-1 transcripts were detected during the entire period of embryonic and early ontogenic developments. Abalone MTF-1 was found to be Cd inducible and highly modulated by heat shock treatment. Conclusion: Abalone MTF-1 possesses a non-consensus structure of activation domains and represents distinct features for its activation mechanism in response to metal overload and heat stress. The activation mechanism of abalone MTF-1 might include both indirect zinc sensing and direct de novo synthesis of transcripts. Taken together, results from this study could be a useful basis for future researches on stress physiology of this abalone species, particularly with regard to heavy metal detoxification and thermal adaptation.

Production and Characterization of Monoclonal Antibodies to Yeast Mitochondrial RNA Polymerase Specificity Factor

  • Lee, Chang-Hwan;Jang, Sei-Heon
    • BMB Reports
    • /
    • v.31 no.6
    • /
    • pp.607-610
    • /
    • 1998
  • Transcription of mitochondrial DNA in the yeast S. cerevisiae depends on recognition of a consensus nonanucleotide promoter sequence by mitochondrial RNA polymerase specificity factor, which is a 43 kDa polypeptide encoded by the nuclear MTF1 gene. Mtf1p has only limited amino acid sequence homology to bacterial sigma factors, but functions in many ways like sigma in that it is required for promoter recognition and initiation of transcription. To analyze the corebinding region of Mtf1p, monoclonal antibodies to this protein were prepared. Recombinant Mtf1p overproduced in E. coli was purified to near homogeneity and used to raise monoclonal antibodies (mAbs). From fused cells screened for Mtf1p mAbs by immunodot blot analysis, 19 positive clones were initially isolated. Further analysis of positive clones by Western blotting resulted in 4 mAbs of Mtf1p.

  • PDF

Effect of the Signal-to-Noise Power Spectra Ratio On MTF compensated EOC images

  • Kang, Chi-Ho;Choi, Hae-Jin
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.202-207
    • /
    • 2002
  • EOC (Electro-Optical Camera) of KOMPSAT-1 (Korea Multi-Purpose SATellite) has been producing land imageries of the world since January 2000. After image data are acquired by EOC, they are transmitted from satellite to ground via X-band RF signal. Then, EOC image data are generated and pass through radiometric and geometric corrections to generate standard products of EOC images. After radiometric correction on EOC image data, Modulation Transfer Function (MTF) compensation is applicable on EOC images with user's request for better image quality. MTF compensation is concerned with filtering EOC images to minimize the effect of degradations. For Image Receiving and Processing System (IRPE) at KOMPSAT Ground Station (KGS), Wiener filter is used in MTF compensation for EOC images. If the Pointing Spread Function (PSF) of EOC system is known, signal-to-noise power spectra ratio is the only factor in the determination of Wiener filter. In this paper, MTF compensation in IRPE at KGS is introduced and MTF compensated EOC 1R images are generated using Wiener filters with various signal-to-noise power spectra ratios. MTF compensated EOC 1R images are correlated with EOC 1R images for observing linearities between them. As a result, the effect of signal-to-noise power spectra ratio is shown on MTF compensated EOC 1R images.

  • PDF