• Title/Summary/Keyword: MS

Search Result 11,302, Processing Time 0.038 seconds

Characterizing Compressive Strength Development in Cement Mortar Utilizing Red Mud Neutralized with Sulfuric Acid (황산 중화 레드머드를 사용한 시멘트 모르타르의 압축강도 발현특성)

  • Kang, Suk-Pyo;Hong, Seong-Uk;Kim, Sang-Jin;Park, Kyu-Eun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.3
    • /
    • pp.231-240
    • /
    • 2023
  • In this research, our goal was to explore the potential use of cement mortar augmented with liquid red mud. To facilitate this, we neutralized liquid red mud(LR) - exhibiting a pH of 10-12 - using sulfuric acid to yield sulfuric acid neutralized red mud(SR). We then evaluated the flow, setting time, and compressive strength of the cement mortar combined with liquid red mud, while also performing a thorough examination of its chemical properties through X-ray diffraction(XRD) and scanning electron microscopy(SEM). The flow tests indicated a decrease in flow values for both MS-LR and MS-SR in comparison to the Plain. Analogously, the setting time for MS-LR and MS-SR was found to be abbreviated when juxtaposed with the Plain. With regards to compressive strength, MS-LR demonstrated a surge in strength at the 1-day mark, while MS-SR displayed a diminution at the 1-day and 3-day timepoints compared to the Plain. XRD analysis illustrated that after 28 days, the XRD patterns of Plain and MS-SR bore significant resemblance, though a new peak was detected in MS-LR. SEM imagery highlighted that the microstructures of Plain and MS-SR were alike, but MS-LR manifested a distinct microstructure, characterized by a finely fibrous formation. Based on these observations, we infer that the replacement of cement mortar with liquid red mud neutralized with sulfuric acid contributes to a noticeable enhancement in strength, thereby verifying its suitability for this application.

Investigation of N-nitrosamines using GC-MS/MS in Han-river Water Supply Systems (GC-MS/MS를 이용한 한강수계 및 상수도계통에서 N-nitrosamines 조사)

  • Yoon, Woo-hyun;Lee, Jun-ho;Lee, Hyun-ju;Lee, Su-won;Ahn, Jae-chan;Kim, Bog-soon
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.5
    • /
    • pp.410-418
    • /
    • 2016
  • This study was conducted to improve the analysis method used for N-nitrosamines and to investigate the occurrences of N-nitrosamines in tributaries of the Han-river, intake stations, water treatment plants and tap water used within the city of Seoul. The samples were pretreated through a solid phase extraction and analyzed using a gas chromatography tandem mass spectrometer (GC-MS/MS). The GC-MS/MS in CI mode was compared with the GC-MS/MS in EI mode by the method detection limits (MDLs). MDLs by GC-CI/MS/MS and GC-EI/MS/MS were 0.2 ~ 1.1 ng/L and 0.2 ~ 1.4 ng/L, respectively. Samples were collected from ten tributaries of the Han-river (T1 ~ T10), six intake stations (I1 ~ I6), six water treatment plants (P1 ~ P6) and 25 taps in Seoul city. The maximum levels of N-nitrosodimethylamine (NDMA) were 0.013 μg/L, 0.008 μg/L, 0.006 μg/L and 0.002 μg/L in tributary water, raw water, finished water and tap water samples, respectively. Detected levels were much lower than 0.1 μg/L corresponding to the guideline value of WHO.

Comparison of Analytical Methods of Tacrolimus in Plasma and Population Pharmacokinetics in Liver Transplant Recipients (Tacrolimus의 혈중농도측정법 비교 및 간이식환자에서의 집단 약동학)

  • Kim, Eun-Young;Kang, Won-Ku;Gwak, Hye-Sun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.18 no.1
    • /
    • pp.60-67
    • /
    • 2008
  • This study aimed to compare a microparticle enzyme immunoassay (MEIA) with a liquid chromatography-tandem mass spectrometry (LC/MS/MS) technique for the measurement of tacrolimus concentrations in adult liver transplant recipients, to investigate how the assay choice influenced the population pharmacokinetics of tacrolimus and to identify patient characteristics that affected pharmacokinetic parameters in each assay. Tacrolimus concentrations from 29 liver (n=52 paired-samples) transplant recipients measured by both MEIA and LC/MS/MS were used to evaluate the performance of these methods in the clinical setting. Tacrolimus pharmacokinetics was studied independently using MEIA and LC/MS/MS data in 70 adult patients using a population approach performed with NONMEM. Patient characteristics which influenced pharmacokinetic parameters in each assay were compared. The relation between LC/MS/MS and MEIA measurements was best described by the regression equation MEIA=1.465*LC/MS/MS-1.336 (r=0.91). Multiple linear regression analysis showed significant inverse relationships between assay difference and hematocrit (Hct) (p<0.025) in liver graft recipients. In MEIA, the population estimate of tacrolimus CL/F and apparent volume of distribution (Vd/F) were found to be 10.1 L/h and 226 L, and in LC/MS/MS, 13 L/h and 305 L respectively. Neither patient's age, weight, gender, grafted hepatic weight, albumin concentration, nor markers of liver function influenced tacrolimus CL/F The final model of CL/F was found to be 10.1+(Hct/Hct mean)$^{12.0}$ in MEIA and 13+(1+Hct/578) in LC/MS/MS indicating that CL/F was influenced by hematocrit.

  • PDF

Comparison of Dietary Habits and Nutrient Intakes in Subjects with Obesity or Hyperglycemia Classified Metabolic Syndrome (비만 또는 고혈당 증상 보유에 따른 대사성증후군의 식습관 및 영양상태 비교)

  • Park Jung-A;Yoon Jin-Sook
    • Journal of Nutrition and Health
    • /
    • v.38 no.8
    • /
    • pp.672-681
    • /
    • 2005
  • Metabolic syndrome (MS) was defined as condition in which the subjects have two or more abnormalities among obesity, hyperlipidemia, hypertension and hyperglycemia. To develop a nutritional education program for MS, this study was performed to compare the dietary habits and nutrients intake of complex symptoms of MS with obesity or hyper-glycemia. The participants in this study were 84 normal adults,62 MS with obesity, 33 MS with hyperglycemia and 54 MS with obesity and hyperglycemia (OB + HG). A dietary survey was conducted using 24-hour recall method. Total cholesterol level of MS with obesity group was significantly higher than other groups. WHR and systolic blood pressure showed no significant difference among MS with obesity, hyperglycemia and OB+HG groups. Dietary intakes of energy, Fe, Vit A, Vit $B_2$ and Ca were less than $75\%$ of 7th Korean RDA in the all groups. Especially, dietary intakes of Vit $B_2$, Vit A and Ca were less than $50\%$ of RDA in MS with hyperglycemia and OB+HG groups. The other nutrient intakes of each group were also below the RDA level except for P, Vit C. It appeared that most of the nutrient intakes in MS with hyperglycemia and OB + HG groups were significantly lower than normal group. In MS with obesity group, each consumption of sweet, organ meat and soup was higher than other groups. Each consumption of garlic and onion in MS with obesity, hyperglycemia and OB + HG groups was lower than normal group. Also, each consumption of soup in MS with hyperglycemia and OB + HG groups was higher than normal group. Indices of nutritional quality (INQ) for Ca, Vit A and Vit $B_2$ were below 1 in all the groups. Food composition group score of MS with hyperglycemia group was significantly lower than normal and MS with obesity groups. Our results indicated that nutritional education program for MS with obesity or hyperglycemia should include specific strategies to modify unsound dietary habits and inappropriate food intake for health.

Forgery Detection Mechanism with Abnormal Structure Analysis on Office Open XML based MS-Word File

  • Lee, HanSeong;Lee, Hyung-Woo
    • International journal of advanced smart convergence
    • /
    • v.8 no.4
    • /
    • pp.47-57
    • /
    • 2019
  • We examine the weaknesses of the existing OOXML-based MS-Word file structure, and analyze how data concealment and forgery are performed in MS-Word digital documents. In case of forgery by including hidden information in MS-Word digital document, there is no difference in opening the file with the MS-Word Processor. However, the computer system may be malfunctioned by malware or shell code hidden in the digital document. If a malicious image file or ZIP file is hidden in the document by using the structural vulnerability of the MS-Word document, it may be infected by ransomware that encrypts the entire file on the disk even if the MS-Word file is normally executed. Therefore, it is necessary to analyze forgery and alteration of digital document through internal structure analysis of MS-Word file. In this paper, we designed and implemented a mechanism to detect this efficiently and automatic detection software, and presented a method to proactively respond to attacks such as ransomware exploiting MS-Word security vulnerabilities.

A Proteomic Approach to Study msDNA Function in Escherichia coli

  • Jeong, Mi-Ae;Lim, Dongbin
    • Journal of Microbiology
    • /
    • v.42 no.3
    • /
    • pp.200-204
    • /
    • 2004
  • Retron is a prokaryotic genetic element that produces multicopy single-stranded DNA covalently linked to RNA (msDNA) by a reverse transcriptase. It was found that cells producing a large amount of msDNA, rather than those that did not, showed a higher rate of mutation. In order to understand the molecular mechanism connecting msDNA production to the high mutation rate the protein patterns were compared by two dimensional gel electrophoresis. Ten proteins were found to be differentially expressed at levels more than three fold greater in cells with than without msDNA, nine of which were identified by MALDI TOF MS. Eight of the nine identified proteins were repressed in msDNA-producing cells and, surprisingly, most were proteins functioning in the dissimilation of various carbon sources. One protein was induced four fold greater in the msDNA producing cells and was identified as a 30S ribosomal protein S2 involved in the regulation of translation. The molecular mechanism underlying the elevated mutation in msDNA-producing cell still remains elusive.

Design and Implementation of BACnet MS/TP Field Controller Prototype and MS/TP Network Monitoring System (BACnet MS/TP 필드제어기 프로토타입 및 MS/TP 네트워크 감시 장치의 설계 및 구현)

  • Park, Tae-Jin;Hong, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.799-808
    • /
    • 2007
  • BACnet is an international standard communication protocol especially designed for building automation and control systems. BACnet uses the Master-Slave/Token-Passing (MS/TP) protocol as one of its field-level networks. A BACnet MS/TP field controller prototype and MS/TP network monitoring system are developed in this study. This report introduces the design and implementation methodology of a BACnet MS/TP field controller hardware, firmware and protocol stack. This report also presents the implementation methodology of BACnet MS/TP network monitoring system using VTS (Visual Test Shell). The methodologies introduced in this report will facilitate the develop and implementation of the BACnet-based control systems in building automation area.

A Method for Protein Identification Based on MS/MS using Probabilistic Graphical Models (확률그래프모델을 이용한 MS/MS 기반 단백질 동정 기법)

  • Li, Hong-Lan;Hwang, Kyu-Baek
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06b
    • /
    • pp.426-428
    • /
    • 2012
  • In order to identify proteins that are present in biological samples, these samples are separated and analyzed under the sequential procedure as follows: protein purification and digestion, peptide fragmentation by tandem mass spectrometry (MS/MS) which breaks peptides into fragments, peptide identification, and protein identification. One of the widely used methods for protein identification is based on probabilistic approaches such as ProteinProphet and BaysPro. However, they do not consider the difference in peptide identification probabilities according to their length. Here, we propose a probabilistic graphical model-based approach to protein identification from MS/MS data considering peptide identification probabilities, number of sibling peptides, and peptide length. We compared our approach with ProteinProphet using a yeast MS/MS dataset. As a result, our model identified 27 more proteins than ProteinProphet at 1% of FDR (false discovery rate), confirming the importance of peptide length information in protein identification.

Analysis of Agrochemical Residues in Tobacco Using QuEChERS Method by GC-MS/MS

  • Lee, Jeong-Min;Jang, Gi-Chul;Hwang, Keon-Joong
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.29 no.2
    • /
    • pp.132-139
    • /
    • 2007
  • This study was performed to apply the more rapid and accurate sample preparation, and the high selectivity and sensitivity of the analyte detection by gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS). QuEChERS (quick, easy, cheap, effective, rugged and safe) method was validated for 49 agrochemicals in the CORESTA Agrochemical Advisory Committee guide and amenable to GC-MS/MS determination. In QuEChERS method, the effects of sorbents (PSA, $C_{18}$ and GCB) and matrix of the analytes in tobacco types (flue-cured, burley and oriental) were investigated. MS/MS acquisition provided high specificity and selectivity for agrochemicals and low limit of quantification. QuEChERS by using PSA alone and the matrix-matched standards gave good recoveries and RSD values in three types of tobaccos. QuEChERS method was no needed to be complex clean-up procedure and would be used as the fast and easy method for agrochemical residue analysis in tobacco.

Quantification of Globotriaosylsphingosine in Urine using UPLC-ESI-MS/MS; Application for Screening Fabry Disease (파브리병의 신속한 진단을 위한 소변 중 Globotriaosylsphingosine의 UPLC-ESI-MS/MS 분석법)

  • Yoon, Hye-Ran
    • YAKHAK HOEJI
    • /
    • v.60 no.1
    • /
    • pp.15-20
    • /
    • 2016
  • Globotriaosylsphingosine (lyso Gb3) is considered as one of the biomarkers for Fabry disease. A rapid and simple UPLC-MS/MS method was developed for the determination of reliable biomarker, lyso Gb3. Total analytical procedure takes only 15 min including sample preparation and MS/MS analysis. Limit of detection was 0.85 ng/ml (S/N=3). The calibration curve was linear over the range of 2.0~400.0 ng/ml ($R^2=0.9999$). Inter-day and intra-day assay accuracy were 93.4~100.6% (RSD, 0.6~6.0%) and 97.5~100.7% (RSD, 3.6~5.2%). Absolute recoveries of 97.6~98.6 showed excellence of a new analytical method. The method was applied to human and mice urines, proved the suitability for the quantification of lyso-Gb3 for screening, diagnosis and therapeutic monitoring of Fabry disease patients.