• 제목/요약/키워드: MRI safety

검색결과 58건 처리시간 0.019초

유방 조직 확장기의 1.5T와 3.0T MRI 환경 내 안정성 평가 (Evaluation of MR Safety of Breast Expander on 1.5T and 3.0T MRI)

  • 정동일;김재석
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.361-366
    • /
    • 2020
  • MRI 검사가 필요한 유방조직확장기 삽입 환자에 대해 체내 안전성을 평가하고자한다. 토크는 1.5 T 정방향 진입 시 0 ml, 150 ml, 300 ml, 450 ml 각각 4, 3, 3, 2이었고, 1.5 T 역방향 진입 시 각각 4, 4, 4, 3이었다. 3.0 T 환경에서는 모든 조건에서 4를 나타냈다. 뒤집힘 실험은 1.5 T 환경에서 300 ml 이상에서 뒤집힘이 발생하지 않았고, 3.0 T 환경에서는 대부분 뒤집힘이 발생하였다. 유방조직확장기 삽입 환자의 MRI 검사는 안전성 측면에서는 3.0 T는 피하고 1.5 T에서 조건부로 가능하다.

Reconsidering the "MR Unsafe" breast tissue expander with magnetic infusion port: A case report and literature review

  • Dibbs, Rami;Culo, Bozena;Tandon, Ravi;Hilaire, Hugo St.;Shellock, Frank G.;Lau, Frank H.
    • Archives of Plastic Surgery
    • /
    • 제46권4호
    • /
    • pp.375-380
    • /
    • 2019
  • Breast tissue expanders (TEs) with magnetic infusion ports are labeled "MR Unsafe." Therefore, patients with these implants are typically prevented from undergoing magnetic resonance imaging (MRI). We report a patient with a total submuscular breast TE who inadvertently underwent an MRI exam. She subsequently developed expander exposure, requiring explantation and autologous reconstruction. The safety profile of TEs with magnetic ports and the use of MRI in patients with these implants is surprisingly controversial. Therefore, we present our case report, a systematic literature review, and propose procedural guidelines to help ensure the safety of patients with TEs with magnetic ports that need to undergo MRI exams.

자장의 세기에 따른 유방 확장기 주위의 인공물 평가 (Evaluation of artifacts around the breast expander according to magnetic field strength)

  • 정동일;김재석
    • 한국정보통신학회논문지
    • /
    • 제24권9호
    • /
    • pp.1144-1149
    • /
    • 2020
  • 유방조직확장기의 Magnetic Valve는 MRI 검사 시 영상 인공물이 발생하여 MRI 검사가 제한적이다. MRI 검사가 필요한 유방조직확장기 삽입 환자에 대해 영상 인공물이 진단영역에 미치는 영향을 평가한다. 자체 제작한 팬텀과 실제 임상 조건을 이용하여 영상 인공물 측정을 실시하였다. 영상 인공물은 1.5 Tesla와 3.0 Tesla 환경에 따라 상이하게 측정되었으며, C-spine, L-spine 검사 시 영상 인공물의 영향이 T-spine에 비해 상대적으로 적었다. 유방암 전이로 인한 MRI 검사가 꼭 필요한 경우 주로 1.5 Tesla에서 Head & Neck 검사와 L-spine 아래 부위를 검사 할 수 있으나 일부 시퀀스에서는 영상 인공물로 인한 왜곡이 발생할 수 있다. 유방조직확장기 삽입 환자의 MRI 검사는 안전성 측면에서는 3.0T는 피하고 1.5T에서 조건부로 가능하다.

MRI 검사 시 환자의 심리적 불안감이 폐쇄공포 및 활력징후에 미치는 영향(환자안전사고에 있어서) (Effects of Claustrophobia, Vital Signs on Psychological Anxiety of the Patients during MRI Examination(In Patient Safety Accident))

  • 김재천;배석환;김용권;이무식
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.231-240
    • /
    • 2015
  • In this study, to find out the effect of psychological anxiety of the patients during MRI examination on the claustrophobia and vital signs, As for a study tool, to measure Anxiety Sensitivity Index(ASI), Kamsung Evaluation Index of Life Environmental Noise(KEI), Diagnostic and Statistical Manual of Mental Disorders(DSM-IV) was used, and for vital signs, blood pressure and pulse rate were measured pre and post MRI examination. In conclusion, it was indicated that though the effect of the general characteristics, psychological anxiety, on noise sensitivity and claustrophobia was small, the psychological anxiety of the patients during MRI examination affected claustrophobia and vital signs.

Interference Issuses of Radio Frequency Identification Devices in Magnetic Resonance Imaging Systems and Computed Tomography Scan

  • Periyasamy, M.;Dhanasekaran, R.
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.295-301
    • /
    • 2015
  • We evaluated certain issues related to magnetic resonance imaging (MRI) coupled with the use of active 2.5 GHz radio frequency identification (RFID) tags for patient identification using low field (0.3 T) MRI and computed tomography (CT) scans. We also investigated the performance of the RFID reader located outside the MRI room by considering several factors. A total of ten active RFID tags were exposed to several MRI sequences and X-rays of CT scan. We found that only card type active RFID tags are suitable for patient identification purpose in MRI environment and both wristbands as well as card tags were suitable for the same in CT environment. Severe artifacts were found in the captured MRI and CT images when the area of the imaging was in proximity to the tags. No external factors affected the performance of active RFID reader stationed outside the MRI scan room.

Experience with 7.0 T MRI in Patients with Supratentorial Meningiomas

  • Song, Sang Woo;Son, Young Don;Cho, Zang-Hee;Paek, Sun Ha
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권4호
    • /
    • pp.405-409
    • /
    • 2016
  • Meningiomas are typically diagnosed by their characteristic appearance on conventional magnetic resonance imaging (MRI). However, detailed image findings regarding peri- and intra-tumoral anatomical structures, tumor consistency and vascularity are very important in pre-surgical planning and surgical outcomes. At the 7.0 T MRI achieving ultra-high resolution, it could be possible to obtain more useful information in surgical strategy. Four patients who were radiologically diagnosed with intracranial meningioma in 1.5 T MRI underwent a 7.0 T MRI. Three of them underwent surgery afterwards, and one received gamma knife radiosurgery. In our study, the advantages of 7.0 T MRI over 1.5 T MRI were a more detailed depiction of the peri- and intra-tumoral vasculature and a clear delineation of tumor-brain interface. In the safety issues, all patients received 7.0 T MRI without any adverse event. One disadvantage of 7.0 T MRI was the reduced image quality of skull base lesions. 7.0 T MRI in patients with meningiomas could provide useful information in surgical strategy, such as the peri-tumoral vasculature and the tumor-brain interface.

CT 보험급여 전후의 CT 및 MRI검사의 이용량과 수익성 변화 (Analysis of utilization and profit for CT and MRI after implementation of insurance coverage for CT)

  • 서종록;유승흠;전기홍;남정모
    • 한국병원경영학회지
    • /
    • 제2권1호
    • /
    • pp.1-21
    • /
    • 1997
  • In order to analyze the shifts in the volume and profits of Computed Tomography(CT) and Magnetic Resonance Imaging(MRI) utilization for a year before and after the implementation of insurance coverage for CT, this study has been undertaken examining CT and MRI cost data from 'Y' University Hospital situated in Seoul, Korea. Following are the results of this study: 1. The medical insurance payment for CT, implemented on January 1, 1996, increased CT utilization from January 1996 to April 1996 due to low insurance premiums: however, from May 1996 the number of CT cases significantly decreased as a result of strengthened medical cost reviews and the new 'Detailed standards for approval of CT' announced near the end of April 1996 by the insurer. 2. Since the implementation of insurance coverage for CT, CT fee reduction rates for reimbursements by the insurer to the hospital were 50% and 40% for January and February, respectively, and 31% and 15% for March and April. A significant point in the lowering of the reduction rate was reached in May at 11%; furthermore, since June the reduction rate fell below the average reduction rate for reimbursements for all procedures. If the 'Detailed standards for approval of CT' had been announced before the implementation of insurance coverage for CT, CT utilization would not have been so high due to the need to meet those 'standards'. In addition, loss of hospital profits resulting from the reduction for reimbursements would not have occurred. 3. The shifts in MRI utilization showed that there was no particular change with the beginning of insurance coverage for CT, and the introduction of the 'Detailed standards for approval of CT' made MRI utilization increase because MRI is free of restrictions imposed by the insurer. 4. The relationship between CT utilization and MRI utilization showed that they were supplementary to each other before insurance coverage for CT, but that CT was substituted for MRI because of strengthened medical cost reviews after t~e beginning of insurance coverage for CT. 5. The shifts in volume by patient characteristics showed that the number of inappropriate case patients, according to the insurer's "Standards for approval", decreased more than the number of appropriate case patients after the introduction of insurance coverage for CT. Therefore, the health insurance fee schemes for CT have influenced patient care. 6. The shifts in profits from CT utilization showed a net profit decrease of 31.6%. In order to match the pre-coverage profit level, 5,471 more cases would need to be seen and productivity would need to be increased by 32.7%. This profit decrease resulted from a decrease of CT utilization and low reimbursements. With insurance coverage, net profits from CT were 24.4%, and a margin of safety ratio was 39.6%. Because of the net profits and margin of safety ratio, CT utilization fees for insured appropriate cases could not be considered inappropriate. 7. The shifts in profits from MRI utilization before and after the introduction of CT coverage showed that in order to match pre-CT coverage profit levels, 2,011 more cases would need to be seen and productivity would need to be increased by 9.2%. The reasons for needing to increase the number of cases and productivity result from cost burdens created by adding new MRI units. But with CT coverage already begun, MRI utilization increased. Combined with a minor increase in the MRI fee schedule, MRI utilization showed a net profit increase of 18.5%. Net profits of 62.8% and a 'margin of safety ratio' of 43.1% for MRI utilization showed that the hospital relied on this non-covered procedure for profits. 8. The shifts in profits from CT and MRI utilization showed the net profits from CT decreased by 2.33billion Won while the net profits from MRI increased by 815.7million Won. Overall, these two together showed a net profit decrease of 1.51billion Won. The shifts in utilization showed a functional substitutionary relationship, but the shifts in profits did not show a substitutionary relationship. From these results, We can conclude that if insurance is to be expanded to include previously uncovered procedures using expensive medical equipment, detailed standards should be prepared in advance. The decrease in profits from the shifts in coverage and changes in fees is a difficult burden that should be shared, not carried by the hospital alone. Also, a new or improved fee schedule system should include revised standards between items listed and the appropriateness of the fee schedule should constantly be ensured. This study focused on one university hospital in Seoul and is therefore limited in general applicability. But it is valuable for considering current issues and problems, such as the influence of CT coverage on hospital management. Future studies will hopefully expand the scope of the issues considered here.

  • PDF

여성골반 MRI 프로토콜 (MRI Protocol of Female Pelvis)

  • 신유리;나성은
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권1호
    • /
    • pp.1-9
    • /
    • 2010
  • 여성골반 질환 영역에 있어서 초음파가 적은 비용과 안전성 등의 이유로 가장 흔히 이용되는 최우선적 검사라 한다면 MRI는 정확한 진단과 치료 결정을 위한 중요한 정보를 제공하는 최선의 영상검사로 이미 널리 이용되고 있다. 여성 골반 MRI의 적응증은 광범위하지만 선천성 기형, 자궁 및 난소 종양의 양성 및 악성 감별진단, 악성 자궁 및 난소 종양의 병기 결정 등에 주로 사용되고 있다. 따라서 여성골반 질환의 정확한 진단과 치료 방침 결정에 있어 각각의 질환에 따른 최적의 영상을 얻기 위한 MRI 프로토콜에 대한 이해가 중요하다.

Assessment of Factors Associated with the Safety Depth of GV15 Yamen -Factors Associated with the Safety Depth of GV15-

  • Park, Soo-Jung;Jin, Ming;Joo, Jong-Cheon;Kwon, Young-Mi
    • 대한약침학회지
    • /
    • 제17권1호
    • /
    • pp.70-73
    • /
    • 2014
  • Objectives: Yamen is the fifteenth acupoint of the Governor Vessel Meridian (GV15). It is anatomically close to the medulla oblongata, so finding the safety depth of the acupoint is very important. However, few studies on the safety depth of GV15 have been done. Methods: This study tried to measure the safety depth of GV15 by using magnetic resonance imaging (MRI) scans and to analyze the factors affecting the safety depth through multiple regression analyses. This study was carried out for patients who had a brain MRI scan while visiting Jeonju Wonkwang Hospital, Korea. The shortest distance between the glabella and the occipital protuberance (DGO), the horizontal distance between the glabella and the back of the head (DGB) and the dangerous depth (DD) were measured from the sagittal views of the MRI images. The DD is the horizontal distance from the skin's surface at GV15 to the spinal dura mater. Results: The model suggested that the safety depth (SD) was significantly associated with gender (${\beta}$ = 0.474, P < 0.0001), DGO (${\beta}$ = 0.272, P = 0.027), and BMI (${\beta}$ = 0.249, P = 0.005) and the combination of three variables can explain the SD, with $R^2$ = 0.571 (Table 3). A longer SD was associated with males and with greater BMI and DGO. Conclusion: This study suggests that gender, BMI and DGO may be important factors when the SD of GV15 is considered clinically through a multiple regression analysis of GV15.

Deep Learning-Based Algorithm for the Detection and Characterization of MRI Safety of Cardiac Implantable Electronic Devices on Chest Radiographs

  • Ue-Hwan Kim;Moon Young Kim;Eun-Ah Park;Whal Lee;Woo-Hyun Lim;Hack-Lyoung Kim;Sohee Oh;Kwang Nam Jin
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1918-1928
    • /
    • 2021
  • Objective: With the recent development of various MRI-conditional cardiac implantable electronic devices (CIEDs), the accurate identification and characterization of CIEDs have become critical when performing MRI in patients with CIEDs. We aimed to develop and evaluate a deep learning-based algorithm (DLA) that performs the detection and characterization of parameters, including MRI safety, of CIEDs on chest radiograph (CR) in a single step and compare its performance with other related algorithms that were recently developed. Materials and Methods: We developed a DLA (X-ray CIED identification [XCID]) using 9912 CRs of 958 patients with 968 CIEDs comprising 26 model groups from 4 manufacturers obtained between 2014 and 2019 from one hospital. The performance of XCID was tested with an external dataset consisting of 2122 CRs obtained from a different hospital and compared with the performance of two other related algorithms recently reported, including PacemakerID (PID) and Pacemaker identification with neural networks (PPMnn). Results: The overall accuracies of XCID for the manufacturer classification, model group identification, and MRI safety characterization using the internal test dataset were 99.7% (992/995), 97.2% (967/995), and 98.9% (984/995), respectively. These were 95.8% (2033/2122), 85.4% (1813/2122), and 92.2% (1956/2122), respectively, with the external test dataset. In the comparative study, the accuracy for the manufacturer classification was 95.0% (152/160) for XCID and 91.3% for PPMnn (146/160), which was significantly higher than that for PID (80.0%,128/160; p < 0.001 for both). XCID demonstrated a higher accuracy (88.1%; 141/160) than PPMnn (80.0%; 128/160) in identifying model groups (p < 0.001). Conclusion: The remarkable and consistent performance of XCID suggests its applicability for detection, manufacturer and model identification, as well as MRI safety characterization of CIED on CRs. Further studies are warranted to guarantee the safe use of XCID in clinical practice.