Stereotactic Radiosurgery of 26 Intracranial Arteriovenous Malformations with Linear Accelerator (뇌동정맥기형 26예의 선형가속기를 이용한 뇌정위다방향 단일방사선치료)

  • Yoon Sei Chul;Suh Tae Suck;Jang Hong Seok;Choi Kyu Ho;Kim Moon Chan;Shinn Kyung Sub;Bahk Yong Whee
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.21-26
    • /
    • 1992
  • From July 1988 through November 1991,26 patients with inoperable arteriovenous malformations were treated with 6 MV linear accelerator at the Kangnam St. Mary's Hospital, Catholic University Medical College. There were 5 females and 21 males with median age of 29 years (range: $6\~63$ years) and median follow up times of 15 months (range: $4\~40$ months). The arteriovenous malformation volumes treated ranged from 1 cm diameter to 3.5 cm rectangular size. The prescribed doses at the isocenter varied from 15 to 30 Gy and were given as a single fraction. To date, all patients performed follow-up not only clinically but also through CT or angiography based radiologic modalities every 6 month. A complete obliteration was achieved in 6 ($23\%$) and partial obliteration in 8 ($31\%$) and no change in 1 ($4\%$). We observed 14 ($54\%$) responsiveness of arteriovenous malformations after radiosurgery by 2 years afterward. Whereas, the decision of the remaining 11 ($42\%$) patients was considered too early to expect the therapeutic response following radiosurgery. No complications through treatment related were observed, yet. Our initial outcome in these first 26 patients with arteriovenous malformations is recommended further follow-up.

  • PDF

Retrospective Analysis on 76 Cases of Cerebral Arteriovenous Malformations Treated by Gamma Knife Radiosurgery

  • Choe, Jae-Gyun;Im, Yong-Seok;Kim, Jong-Soo;Hong, Seung-Chyul;Shin, Hyung-Jin;Lee, Jung-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.6
    • /
    • pp.265-269
    • /
    • 2008
  • Objective : Outcome of gamma knife radiosurgery (GKS) in the consecutive 100 cases with cerebral arteriovenous malformations (AVMs) was analyzed. Methods : Data from initial 100 patients treated with GKS in the authors' institute were reviewed retrospectively. Spetzler-Martin grade at diagnosis were I in 18 patients, II in 27, III in 36, IV in 11, and V in 8. Thirty-five patients had experienced previous bleeding, 27 patients presented with seizure, and 31 patients presented with headache. The mean volume of the lesion was $4.3\;cm^3\;(0.1-29.3\;cm^3)$. The median radiation dose delivered to the margin was 20.0Gy (13-32Gy). Mean follow-up period was 37.5 months (5-63 months). Results : Angiographic follow-up was performed in 48 patients at least 2 years after GKS. Sixteen patients were lost in follow up following 2 years from GKS. Twenty-eight of 48 patients (58%) showed complete obliteration and 20 patients (42%) showed partial obliteration. Seven patients presented with post-GKS hemorrhage. Adverse radiation effect (ARE) was observed at follow-up MRI in 25 of 76 patients, and it was symptomatic in 5 patients. Complete obliteration was confirmed in 24 of 31 (77%) patients with volume less than $4\;cm^3$, meanwhile only 4 of 17 (24%) patients with volume of $4\;cm^3$ or more showed complete obliteration. Complete obliteration rate was 67% with 20Gy or higher marginal dose, 63% with 15-20 Gy, and 17% with less than 15Gy. Conclusion : GKS can provide high rates of obliteration with acceptable risk of morbidity in a subgroup of small AVMs. However, overall outcome in whole spectrum of AVMs, in which large proportion of cases have unfavorable characteristics for radiosurgery, is much worse. More effective therapeutic strategy needs to be developed for large AVMs that are difficult to be managed with current available treatment modalities.

Imaging Assessment of Primary Prostate Cancer, Focused on Advanced MR Imaging and PET/CT (자기공명영상과 PET/CT를 중심으로 한 전립선 암의 영상 진단)

  • Jang, Jin-Hee;Byun, Jae-Young;Kim, Min-Sung;Lee, Young-Joon;Oh, Sun-Nam;Rha, Sung-Eun;Yoo, Ie-Ryung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.89-99
    • /
    • 2008
  • Imaging assessment of prostate cancer is one of the most difficult sections of oncology imaging. Detecting, localizing and staging of the primary prostate cancer by preoperative imaging are still challenging for the radiologist. Magnetic resonance (MR) imaging provides excellent soft tissue contrast and is widely used for solid organ imaging, but results of preoperative imaging of the prostate gland with conventional MR imaging is unsatisfactory. Positron emission tomography and computed tomography (PET/CT) is the cornerstone in oncology imaging, but some limitations prohibit the assessment of primary prostate cancer with PET or PET/CT. Recent studies to overcome these insufficient accuracies of imaging evaluation of primary prostate cancers with advanced MR techniques and PET and PET/CT are reported. In this article, we review the imaging findings of prostate cancer on variable modalities, focused on MR imaging and PET/CT.

  • PDF

Usefulness of Silent MRA for Evaluation of Aneurysm after Stent-Assisted Coil Embolization

  • You Na Kim;Jin Wook Choi;Yong Cheol Lim;Jihye Song;Ji Hyun Park;Woo Sang Jung
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.246-255
    • /
    • 2022
  • Objective: To determine the usefulness of Silent MR angiography (MRA) for evaluating intracranial aneurysms treated with stent-assisted coil embolization. Materials and Methods: Ninety-nine patients (101 aneurysms) treated with stent-assisted coil embolization (Neuroform atlas, 71 cases; Enterprise, 17; LVIS Jr, 9; and Solitaire AB, 4 cases) underwent time-of-flight (TOF) MRA and Silent MRA in the same session using a 3T MRI system within 24 hours of embolization. Two radiologists independently interpreted both MRA images retrospectively and rated the image quality using a 5-point Likert scale. The image quality and diagnostic accuracy of the two modalities in the detection of aneurysm occlusion were further compared based on the stent design and the site of aneurysm. Results: The average image quality scores of the Silent MRA and TOF MRA were 4.38 ± 0.83 and 2.78 ± 1.04, respectively (p < 0.001), with an almost perfect interobserver agreement. Silent MRA had a significantly higher image quality score than TOF MRA at the distal internal carotid artery (n = 57, 4.25 ± 0.91 vs. 3.05 ± 1.16, p < 0.001), middle cerebral artery (n = 21, 4.57 ± 0.75 vs. 2.19 ± 0.68, p < 0.001), anterior cerebral artery (n = 13, 4.54 ± 0.66 vs. 2.46 ± 0.66, p < 0.001), and posterior circulation artery (n = 10, 4.50 ± 0.71 vs. 2.90 ± 0.74, p = 0.013). Silent MRA had superior image quality score to TOF MRA in the stented arteries when using Neuroform atlas (4.66 ± 0.53 vs. 3.21 ± 0.84, p < 0.001), Enterprise (3.29 ± 1.59 vs. 1.59 ± 0.51, p = 0.003), LVIS Jr (4.33 ± 1.89 vs. 1.89 ± 0.78, p = 0.033), and Solitaire AB stents (4.00 ± 2.25 vs. 2.25 ± 0.96, p = 0.356). The interpretation of the status of aneurysm occlusion exhibited significantly higher sensitivity with Silent MRA than with TOF MRA when using the Neuroform Atlas stent (96.4% vs. 14.3%, respectively, p < 0.001) and LVIS Jr stent (100% vs. 20%, respectively, p = 0.046). Conclusion: Silent MRA can be useful to evaluate aneurysms treated with stent-assisted coil embolization, regardless of the aneurysm location and type of stent used.

2023 Survey on User Experience of Artificial Intelligence Software in Radiology by the Korean Society of Radiology

  • Eui Jin Hwang;Ji Eun Park;Kyoung Doo Song;Dong Hyun Yang;Kyung Won Kim;June-Goo Lee;Jung Hyun Yoon;Kyunghwa Han;Dong Hyun Kim;Hwiyoung Kim;Chang Min Park;Radiology Imaging Network of Korea for Clinical Research (RINK-CR)
    • Korean Journal of Radiology
    • /
    • v.25 no.7
    • /
    • pp.613-622
    • /
    • 2024
  • Objective: In Korea, radiology has been positioned towards the early adoption of artificial intelligence-based software as medical devices (AI-SaMDs); however, little is known about the current usage, implementation, and future needs of AI-SaMDs. We surveyed the current trends and expectations for AI-SaMDs among members of the Korean Society of Radiology (KSR). Materials and Methods: An anonymous and voluntary online survey was open to all KSR members between April 17 and May 15, 2023. The survey was focused on the experiences of using AI-SaMDs, patterns of usage, levels of satisfaction, and expectations regarding the use of AI-SaMDs, including the roles of the industry, government, and KSR regarding the clinical use of AI-SaMDs. Results: Among the 370 respondents (response rate: 7.7% [370/4792]; 340 board-certified radiologists; 210 from academic institutions), 60.3% (223/370) had experience using AI-SaMDs. The two most common use-case of AI-SaMDs among the respondents were lesion detection (82.1%, 183/223), lesion diagnosis/classification (55.2%, 123/223), with the target imaging modalities being plain radiography (62.3%, 139/223), CT (42.6%, 95/223), mammography (29.1%, 65/223), and MRI (28.7%, 64/223). Most users were satisfied with AI-SaMDs (67.6% [115/170, for improvement of patient management] to 85.1% [189/222, for performance]). Regarding the expansion of clinical applications, most respondents expressed a preference for AI-SaMDs to assist in detection/diagnosis (77.0%, 285/370) and to perform automated measurement/quantification (63.5%, 235/370). Most respondents indicated that future development of AI-SaMDs should focus on improving practice efficiency (81.9%, 303/370) and quality (71.4%, 264/370). Overall, 91.9% of the respondents (340/370) agreed that there is a need for education or guidelines driven by the KSR regarding the use of AI-SaMDs. Conclusion: The penetration rate of AI-SaMDs in clinical practice and the corresponding satisfaction levels were high among members of the KSR. Most AI-SaMDs have been used for lesion detection, diagnosis, and classification. Most respondents requested KSR-driven education or guidelines on the use of AI-SaMDs.

Analysis of Exploratory Thoracotomy in Non-Small Cell Lung Cancer (원발성 폐암에서의 시험적 개흉술의 분석)

  • 허재학;성숙환;김영태
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.536-542
    • /
    • 1999
  • Background: The purpose of this study is to improve the quality of the diagnostic procedures in the preoperative evaluation so as to reduce the unnecessary thoracotomy and to ensure resectability in non-small cell lung cancer. Material and Method: Of 616 patients who underwent thoracotomy for primary lung cancer from January 1990 to December 1996, 59 patients(9.6%) turned out to have inoperable lesions after the thoracotomy. We reprospectively reviewed the bronchoscopic findings, methods of tissue diagnosis, CT scans, pulmonary function test and lung perfusion scan, reasons for nonresectability, and adjuvant therapy, and then followed up on the survival rate after exploratory thoracotomy. Result: The cell types were squamous cell carcinoma in 38, adenocarcinoma in 15, large cell carcinoma in 3 and others in 3. Primary loci were RUL in 20, RML in 6, RLL in 8, LUL in 13, LLL in 4 and others in 8. The reasons for non-resectability were various; direct tumor invaison to mediastinal structures(n=41), seeding on pleural cavity(n=8), poor pulmonary function(n=2), invasions to extranodal mediastinal lymph node(n=2), technical non- resectability due to extensive chest wall invasion (n=3), small cell carcinoma (n=1), malignant lymphoma(n=1), and multiple rib metastases(n=1). In the follow-up of 58 patients, 1-year survival rate was 55.2% and 2-year survival rate was 17.2% and the mean survival time was 14 months. When compared according to cell types or postoperative adjuvant therapeutic modalities, no significant difference in the survival rates were found. The squamous cell carcinoma was frequently accompanied by local extension to contiguous structures and was the main cause of non-resectability. In adenocarcinoma, pleural seeding with malignant effusion was frequently encountered, and was the major reason for non-resectability. Conclusion: These data revealed that if appropriate preoperative diagnostic tools had been available, many unnecessary thoracotomies could have been avoided. Both the use of thoracoscopy in selected cases of adenocarcinoma and the more aggressive surgical approach to the locally advanced tumor could reduce the incidence of unnecessary thoracotomies for non-small cell lung cancers.

  • PDF

Comparison of CT based-CTV plan and CT based-ICRU38 plan in Brachytherapy Planning of Uterine Cervix Cancer (자궁경부암 강내조사 시 CT를 이용한 CTV에 근거한 치료계획과 ICRU 38에 근거한 치료계획의 비교)

  • Cho, Jung-Ken;Han, Tae-Jong
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • Purpose : In spite of recent remarkable improvement of diagnostic imaging modalities such as CT, MRI, and PET and radiation therapy planing systems, ICR plan of uterine cervix cancer, based on recommendation of ICRU38(2D film-based) such as Point A, is still used widely. A 3-dimensional ICR plan based on CT image provides dose-volume histogram(DVH) information of the tumor and normal tissue. In this study, we compared tumor-dose, rectal-dose and bladder-dose through an analysis of DVH between CTV plan and ICRU38 plan based on CT image. Method and Material : We analyzed 11 patients with a cervix cancer who received the ICR of Ir-192 HDR. After 40Gy of external beam radiation therapy, ICR plan was established using PLATO(Nucletron) v.14.2 planing system. CT scan was done to all the patients using CT-simulator(Ultra Z, Philips). We contoured CTV, rectum and bladder on the CT image and established CTV plan which delivers the 100% dose to CTV and ICRU plan which delivers the 100% dose to the point A. Result : The volume$(average{\pm}SD)$ of CTV, rectum and bladder in all of 11 patients is $21.8{\pm}6.6cm^3,\;60.9{\pm}25.0cm^3,\;111.6{\pm}40.1cm^3$ respectively. The volume covered by 100% isodose curve is $126.7{\pm}18.9cm^3$ in ICRU plan and $98.2{\pm}74.5cm^3$ in CTV plan(p=0.0001), respectively. In (On) ICRU planning, $22.0cm^3$ of CTV volume was not covered by 100% isodose curve in one patient whose residual tumor size is greater than 4cm, while more than 100% dose was irradiated unnecessarily to the normal organ of $62.2{\pm}4.8cm^3$ other than the tumor in the remaining 10 patients with a residual tumor less than 4cm in size. Bladder dose recommended by ICRU 38 was $90.1{\pm}21.3%$ and $68.7{\pm}26.6%$ in ICRU plan and in CTV plan respectively(p=0.001) while rectal dose recommended by ICRU 38 was $86.4{\pm}18.3%$ and $76.9{\pm}15.6%$ in ICRU plan and in CTV plan, respectively(p=0.08). Bladder and rectum maximum dose was $137.2{\pm}50.1%,\;101.1{\pm}41.8%$ in ICRU plan and $107.6{\pm}47.9%,\;86.9{\pm}30.8%$ in CTV plan, respectively. Therefore, the radiation dose to normal organ was lower in CTV plan than in ICRU plan. But the normal tissue dose was remarkably higher than a recommended dose in CTV plan in one patient whose residual tumor size was greater than 4cm. The volume of rectum receiving more than 80% isodose (V80rec) was $1.8{\pm}2.4cm^3$ in ICRU plan and $0.7{\pm}1.0cm^3$ in CTV plan(p=0.02). The volume of bladder receiving more than 80% isodose(V80bla) was $12.2{\pm}8.9cm^3$ in ICRU plan and $3.5{\pm}4.1cm^3$ in CTV plan(p=0.005). According to these parameters, CTV plan could also save more normal tissue compared to ICRU38 plan. Conclusion : An unnecessary excessive radiation dose is irradiated to normal tissues within 100% isodose area in the traditional ICRU plan in case of a small size of cervix cancer, but if we use CTV plan based on CT image, the normal tissue dose could be reduced remarkably without a compromise of tumor dose. However, in a large tumor case, we need more research on an effective 3D-planing to reduce the normal tissue dose.

The Role of Camera-Based Coincidence Positron Emission Tomography in Nodal Staging of Non-Small Cell Lung Cancer (비소세포폐암의 림프절 병기 결정에서 Coincidence PET의 역할)

  • Lee, Sun-Min;Choi, Young-Hwa;Oh, Yoon-Jung;Cheong, Seong-Cheoll;Park, Kwang-Joo;Hwang, Sung-Chul;Lee, Yi-Hyeong;Park, Chan-H;Hahn, Myung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.642-649
    • /
    • 1999
  • Background: It is very important to determine an accurate staging of the non-small cell lung cancer(NSCLC) for an assessment of operability and it's prognosis. However, it is difficult to evaluate tumor involvement of mediastinal lymph nodes accurately utilizing noninvasive imaging modalities. PET is one of the sensitive and specific imaging modality. Unfortunately PET is limited use because of prohibitive cost involved with it's operation. Recently hybrid SPECT/PET(single photon emission computed tomography/positron emission tomography) camera based PET imaging was introduced with relatively low cost. We evaluated the usefulness of coincidence detection(CoDe) PET in the detection of metastasis to the mediastinal lymph nodes in patients with NSCLC. Methods: Twenty one patients with NSCLC were evaluated by CT or MRI and they were considered operable. CoDe PET was performed in all 21 patients prior to surgery. Tomographic slices of axial, coronal and sagittal planes were visually analysed. At surgery, mediastinal lymph nodes were removed and histological diagnosis was performed. CoDe PET findings were correlated with histological findings. Results: Twenty of 21 primary tumor masses were detected by the CoDe PET. Thirteen of 21 patients was correctly diagnosed mediastinal lymph node metastasis by the CoDe PET. Pathological N0 was 14 cases and the specificity of N0 of CoDe PET was 64.3%. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of N1 node was 83.3%, 73.3%, 55.6%, 91.7%, and 76.2% respectively. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of N2 node was 60.0%, 87.5%, 60.0%,87.5%, and 90.0% respectively. There were 3 false negative cases but the size of the 3 nodes were less than 1cm. The size of true positive nodes were 1.1cm, 1.0cm, 0.5cm respectively. There were 1 false positive among the 12 lymph nodes which were larger than 1cm. False positive cases consisted of 1 tuberculosis case, 1 pneumoconiosis case and 1 anthracosis case. Conclusion: CoDe PET has relatively high negative predictive value in the enlarged lymph node in staging of mediastinal nodes in patients with NSCLC. Therefore CoDe PET is useful in ruling out metastasis of enlarged N3 nodes. However, further study is needed including more number of patients in the future.

  • PDF