MRI Quantification Analysis on Fall in Sick Times of the Cerebral Infarction Patients Using Object-Centered Hierarchical Planning (객체 중심 계층적 계획을 이용한 뇌경색 환자의 시기별 MRI 정량적 분석에 관한 연구)

  • Ha, Kwang;Jeon, Gye-Rok;Kim, Gil-Joong
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.61-68
    • /
    • 2003
  • This paper presents a quantitative analysis method for fall in sick times of the cerebral infarction patients using three types of magnetic resonance image, which play an important role in deciding method of medical treatment. For this object, image characteristics obtained by three radiographic methods of MRI and their relation were analyzed by means of object centered hierarchical Planning method. This methode presents an approach to the knowledge based processes for image interpretation and analysis. To compare three type of MRI. a multiple warping algorithm and affine transform method performed for image matching. Then each fall in sick times level of cerebral infarction was quantified and pseudo-color mapping performed by comparing gray level value one another according to Previously obtained hand maid data. The result of this study was compared to a medical doctors decision.

Effect of Metals used in Orthopedic on Magnetic Resonance Imaging I (정형보철용 금속이 자기공명영상에 미치는 영향 I)

  • Kim, Hyeong-Gyun;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.46-50
    • /
    • 2012
  • Stainless steel and titanium used for orthopedic prosthetic metal, magnetic resonance imaging was measured quantitatively the extent of distortion. Based on reading tests at varying metal magnetic resonance imaging (MRI) were investigated. To two image acquisition conditions for having three metal bodies mutually quantitative it compared analyzed the image of cross direction and the image of lengthwise. As for the distortion of the magnetic resonance image, as for the distortion of image it became small in the order of Clip, Strainless and Titanium. In addition, with T1WI and T2WI which are image acquisition condition T2WI the distortion of image became small. As for the distortion of the image by the metal, you could see the distortion of image in elliptical shape, the metal a bigger image distortion appeared in many parts. If clinical doctor has the condition of the same operation, use the Titanium material, it can, raising the diagnostic value of magnetic resonance image inspection after the operating from Stainless.

Fabrication of a Staircase Coil with Improved SNR and Image Uniformity by Structural Changes of a Conventional Birdcage Coil at 1.5T MRI

  • Ryang, Kyung-Seung;Shin, Yong-Jin
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.7 no.1
    • /
    • pp.25-36
    • /
    • 2003
  • The performance of radio frequency (RF) coils, used in MRI units, is determined by the image uniformity and the signal-to-noise ratio (SNR). Birdcage and surface coils are commonly used. A birdcage coil provides a good image uniformity while a surface coil produces a high SNR. In this study, therefore, a staircase coil was designed from a standard version of a birdcage coil, with some structural changes to increase SNR while maintaining image uniformity. In phantom experiments, the improvement of the image to uniformity and the SNR increase of the staircase coil compared with the values for the birdcage coil were about 3.5% and 35%, respectively. In clinical experiment, the SNR increase of the staircase coil, compared with the value for the birdcage coil was about 40% in bone, muscle and blood-vessel tissues. These results show that the performance of the staircase coil was very improved over the standard birdcage coil in terms of SNR, and that image uniformity was maintained. Therefore, the staircase coil designed by this study should be useful in experimental and clinical l.5T MRI systems, and this coil offers an alternative method of quadrature detection.

  • PDF

Representation Techniques for 4-Dimensional MR Images

  • Homma, Kazuhiro;Takenaka, Kenji;Nakai, Yoshihiko;Hirose, Takeshi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.429-431
    • /
    • 2002
  • Metabolic analysis of biological tissues, the interventional radiology in MRT (Magnetic Resonance Treatment) and for clinical diagnoses, representation of 4-Dimensional (4D) structural information (x,y,z,t) of biological tissues is required. This paper discusses image representation techniques for those 4D MR Images. We have proposed an image reconstruction method for ultra-fast 3D MRI. It is based on image interpolation and prediction of un-acquired pictorial data in both of the real and the k-space (the acquisition domain in MRI). A 4D MR image is reconstructed from only two 3D MR images and acquired a few echo signals that are optimized by prediction of the tissue motion. This prediction can be done by the phase of acquired echo signal is proportioned to the tissue motion. On the other hand, reconstructed 4D MR images are represented as a 3D-movie by using computer graphics techniques. Rendered tissue surfaces and/or ROIs are displayed on a CRT monitor. It is represented in an arbitrary plane and/or rendered surface with their motion. As examples of the proposed representation techniques, the finger and the lung motion of healthy volunteers are demonstrated.

  • PDF

Multiparametric MRI in Active Surveillance of Prostate Cancer: An Overview and a Practical Approach

  • Chau Hung Lee;Teck Wei Tan;Cher Heng Tan
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1087-1099
    • /
    • 2021
  • MRI has become important for the detection of prostate cancer. MRI-guided biopsy is superior to conventional systematic biopsy in patients suspected with prostate cancer. MRI is also increasingly used for monitoring patients with low-risk prostate cancer during active surveillance. It improves patient selection for active surveillance at diagnosis, although its role during follow-up is unclear. We aim to review existing evidence and propose a practical approach for incorporating MRI into active surveillance protocols.

A Study on the Usability of Echo Planar Image T2 FLAIR Sequence in the MRI of Acute Ischemic Cerebral Infarction (급성 허혈성 뇌경색 환자의 자기공명영상 검사 시 Echo Planar Image T2 FLAIR 기법의 유용성에 관한 연구)

  • Roh, Taegwan;Jo, Yongkeun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.957-964
    • /
    • 2020
  • T2 FLAIR sequence of MRI in Acute Ischemic Stroke patients is meaningful to those who have the diagnosis of cerebral hemorrhage and neurological deficiency, including the detection of cerebral infarction around Cerebrospinal fluid. However, because of the long acquisition time and mutative motion artifacts caused by movement, It is difficult to take the MRI image acquisition for non-cooperative patients who need to apply a rapid image acquisition. In this study, we applied the EPI-FLAIR sequence, which is one of the fastest pulse sequences in use, which is a combination of EPI sequence and T2 FLAIR sequence, to patients with acute ischemic cerebral infarction. Based on the qualitative and quantitative evaluation results of the EPI-FLAIR and T2 FLAIR image, we will evaluate the diagnostic usefulness of the EPI-FLAIR sequence.

A Study on the Effects of Humor Package on Memory - Focusing on fMRI Demonstration - (유머 패키지가 기억에 미치는 영향 -fMRI 실증을 중심으로-)

  • Seok-Hwan Bae;Myung-Chul Park;Jae-Sang You
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.185-190
    • /
    • 2023
  • This study designed and produced stimuli in the form of canned images of fun humor, character, quirky, and sexy humor, and measured the signal values (SI) of the hippocampus associated with memory through fMRI analysis. The results of 20 participants showed that there were differences in SI values according to gender and age, and the fun humor image stimuli had the highest SI values. Men showed higher SI values for fun humor image stimuli, while women showed higher SI values for character humor image stimuli. In addition, those in their 20s showed higher SI values for fun humor image stimuli, while those in their 30s showed higher SI values for quirky humor image stimuli. Considering these findings, it is expected that more effective results can be obtained by utilizing fun humor images and characters in package design.

Cancellation of Motion Artifact in MRI (MRI에 있어서 체동 아티팩트의 제거)

  • Kim, Eung-Kyeu
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.3
    • /
    • pp.70-78
    • /
    • 2000
  • In this study, a new method for canceling MRI artifacts through the motion translation of image plane is presented Breathing often makes problems in a clinical diagnosis. Assuming that the head moves up and down due to breathing, rigid translational motions in only y(phase encoding axis) direction are treated Unlike the conventional Iterative phase retrieval algorithm, this method is based on the MRI imaging process and analyzing of Image property A new constraint condition with which the motion component and the true image component in the MRI signal can be separated by a simple algebraic operation is extracted After the x(read out) directional Fourier transformation of MRI signal is done, the y(phase encoding) directional spectrum phasing value is Just an algebraic sum of the Image component and the motion component Meanwhile, as It is known that the density of subcutaneous fat area is almost uniform in the head tomographs, the density distribution along a y directional line on this fat area is regarded as symmetric shape If the density function is symmetric, then the phase of spectrum changes linearly with the position Hence, the departure component from the linear function can be separated as the motion component Based on this constrant condition, the new method of artifact cancellation is presented Finally, the effectiveness of this algorithm IS shown by using a phantom with simulated motions.

  • PDF

Breast Magnetic Resonance Image (MRI) Guideline: Breast Imaging Study Group of Korean Society of Magnetic Resonance in Medicine Recommendations

  • Choi, Seon Hyeong;Kang, Bong Joo;Jung, Seung Eun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.205-208
    • /
    • 2018
  • The purpose of this study is to establish an appropriate protocol for breast magnetic resonance imaging (MRI) in the discipline of image quality standards. The intention of the protocol is to increase effectiveness of medical image information exchange involved in construction, activation, and exchange of clinical information for healthcare.

Development of MRI Phantom for Assessing MR Image Quality (자기공명영상 화질 평가용 팬텀 개발에 관한 연구)

  • Ahn, Chang-Beom;Na, Dong-Gyu;Kim, Kwang-Gi;Kim, Dong-Sung;Kim, In-Su;Lee, Jung-Whee;Hong, Suk-Joo;Byun, Jae-Ho;Khang, Hyun-Soo;Jang, Gi-Won;Song, In-Chan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.89-97
    • /
    • 2006
  • Purpose : To evaluate MR image qualities we developed a new MRI phantom with the fixation structures necessary to position it into coil firmly. Materials and methods : We designed MRI phantom for eight evaluation items such as slice thickness accuracy, high contrast spatial resolution, low contrast object detectability, geometry accuracy, slice position accuracy, image intensity uniformity, percent signal ghosting and signal to noise ratio. For the positioning of phantom at coils, the fixation structures were set up on the surface of phantom. Six different MRI units were used for test the possibility for the clinical application and their image qualities were evaluated. Results : We acquired appropriate MR image qualities enough for the evaluation on all used MR units and confirmed that their evaluations were within reliable values compared to real ones for some items. The positioning of our phantom into head coils with fixation structures worked well for proper imaging. Conclusion : We found that our prototype of MRI phantom had the possibility of clinical application for MR image quality assessment.

  • PDF