Measurement of joint resistance of Bi-2223/Ag tapes using field decay technique (자장감쇄법을 이용한 Bi-2223/Ag 선재의 접합저항 측정 평가)

  • 김정호;김규태;주진호;최세용;나완수;하홍수;오상수
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.294-296
    • /
    • 2002
  • Considering the application of high temperature superconductor to MRI, the loss at conductor joint would be very important. Therefore, we have carried out a measurement of joint resistance of Bi-2223/Ag tapes at 77 K. A pancake coil was wound by Bi-2223/Ag tape. Both ends the tape were overlapped and soldered to each other. The DC current is induced in the pancake coil by energizing the excitation coil wound by copper wire closely located to the pancake coil. The decay behaviour of the current in coils was clearly separated in two regimes, and initial fast decay of the order of minutes followed by a slow logarithmic-like decay, From this data, the resistance of the joint was evaluated as 2.74 n$\Omega$.

  • PDF

자기공명 영상촬영을 위한 임의로 선택된 모양의 최소인덕턴스 경사자계코일의 설계 (Minimum-Inductance MRI Gradient Coil Design with Arbitrarily-Selected Shape)

  • Lee, J.K.;Yang, Y.J.;Yi, Y.;Cho, Z.H.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.85-87
    • /
    • 1994
  • This paper proposes a new inductance minimization scheme for a gradient system of arbitrarily selected shape. Although it is important to minimize the gradient coil inductance to reduce the current switching time, such minimization has been possible only for cylindrical or parallel biplanar coils. By using small current loops on arbitrarily selected surface as optimization elements, the inductance of the whole circuit can be minimized using the loop's self- and mutual-inductances. Wire positions can be easily derived from the loop current distribution. Preliminary studies for the design of x-directional surface gradient coil show the utility of tile proposed gradient coil design scheme.

  • PDF

Low-Power Design of the Surface Gradient Coil for Magnetic Resonance Imaging (자기공명영상촬영을 위한 표면경사자계코일의 저전력 설계)

  • Oh, Chang-Hyun;Lee, Jong-Kwon;Yi, Yun;Kim, Min-Gi
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.33-35
    • /
    • 1993
  • A new low-power, high-order optimization scheme to design surface gradient coils (SGC) is proposed for magnetic resonance imaging (MRI). Although previous SGCs have been designed and constructed just to get strong linear gradients, this paper proposes more systematic ways of SGC design by minimizing electrical power consumption in the gradient coil and by removing unnecessary high-order field distortions in the imaging region. By assuming continuous current flow on the coil surface which may be or may not be planar, power consumption in the coil is minimized. According to the simulation results, the SGC designed by using the proposed scheme seems to produce much more uniform linear gradient field using less electrical power compared to the previously proposed SGCs.

  • PDF

Preliminary Study of RF Surface Coil to Get High Resolution Skin Image (고해상도 피부영상을 얻기 위한 Surface Coil의 예비연구)

  • Woo, Dong-Cheol;Yoon, Seong-Ik;Yoon, Moon-Hyun;Choe, Bo-Young
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.35-38
    • /
    • 2005
  • In our country, the skin image and MR Microscopy research has been processed but there were not their outstanding results. So this study start to improve the techniques can get high resolution skin images and to make RF surface coils. Volume coils are sometimes unavailable, or do not provide adequate RF power or SNR for some applications. In high resolution skin and tissue structure images current coils have a technical limitation. It is well known that standard single-loop surface coils, although offering high SNR characteristics, have poor B1 homogeneity. As the RF surface coil need change its geometry we get improved images. So, The magnetic field simulation that is first step to make and design RF surface coil will support reference data.

  • PDF

Development of $^1H-^{31}P$ Animal RF Coil for pH Measurement Using a Clinical MR Scanner (임상용 MR에서 pH 측정을 위한 동물 실험용 $^1H-^{31}P$ RF 코일 개발)

  • Kim, Eun Ju;Kim, Daehong;Lee, Sangwoo;Heo, Dan;Lee, Young Han;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2014
  • Purpose : To establish a pH measurement system for a mouse tumor study using a clinical scanner, to develop the $^1H$ and 31P radio frequency (RF) coil system and to test pH accuracy with phantoms. Materials and Methods: The $^1H$ and the $^{31}P$ surface coils were designed to acquire signals from mouse tumors. Two coils were positioned orthogonally for geometric decoupling. The pH values of various pH phantoms were calculated using the $^1H$ decoupled $^{31}P$ MR spectrum with the Henderson-Hasselbalch equation. The calculated pH value was compared to that of a pH meter. Results: The mutual coil coupling was shown in a standard $S_{12}$. Coil coupling ($S_{12}$) were -73.0 and -62.3 dB respectively. The signal-to-noise ratio (SNR) obtained from the homogeneous phantom $^1H$ image was greater than 300. The high resolution in vivo mice images were acquired using a $^{31}P$-decoupled $^1H$ coil. The pH values calculated from the $^1H$-decoupled $^{31}P$ spectrum correlated well with the values measured by pH meter ($R^2$=0.97). Conclusion: Accurate pH values can be acquired using a $^1H$-decoupled $^{31}P$ RF coil with a clinical scanner. This two-surface coil system could be applied to other nuclear MRS or MRI.

Postmortem analysis of a failed liquid nitrogen-cooled prepolarization coil for SQUID sensor-based ultra-low field magnetic resonance

  • Hwang, Seong-Min;Kim, Kiwoong;Yu, Kwon Kyu;Lee, Seong-Joo;Shim, Jeong Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.44-48
    • /
    • 2014
  • A liquid nitrogen-cooled prepolarization ($B_p$) coil made for ultra-low field nuclear magnetic resonance and magnetic resonance imaging (ULF-MR) designed to generate 7 mT/A was fabricated. However, with suspected internal insulation failure, the coil was investigated in order to find out the source of the failure. This paper reports detailed build of the failed $B_p$ coil and a number of analysis methods utilized to figure out the source and the mode of failure. The analysis revealed that pyrolytic graphite sheet linings put on either sides of the coil for better thermal conduction acted as an electrical bridge between inner and outer layers of the coil to short out the coil whenever a moderately high voltage was applied across the coil. A simple model circuit simulation corroborated the analysis and further revealed that the failed insulation acted effectively as a damping resistor of $R_{d,eff}=6{\Omega}$ across the coil. This damping resistance produced a 50 ms-long voltage tail after the coil current was ramped down, making the coil not suitable for use in ULF-MR, which requires complete removal of magnetic field from $B_p$ coil within milliseconds.

Development of an Active Magnetic Noise Shielding System for a Permanent Magnet Based MRI (영구자석 MRI를 위한 능동형 자기 잡음 차폐시스템 기술 개발)

  • 이수열;전인곤;이항노;이정한
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.181-188
    • /
    • 2003
  • In this paper, we introduce a magnetic noise shielding method to reduce the noise effects in permanent magnet based MRI systems. Through FEM electromagnetic analyses, we have shown that the magnetic noise component parallel to the main magnetic field is the major component that makes various artifacts in the images obtained with a permanent magnet based MRI. Based on the FEM analyses, we have developed an active magnetic noise shielding system composed of a magnetic field sensor, compensation coils, and a coil driving system. The shielding system has shown a noise rejection ratio of about 30dB at the frequency below several Hz. We have experimentally verified that the shielding system greatly improves the image quality in a 0.3 Tesla MRI system.

Endovaginal and Endorectal Surface Coils for in-ViVo Human MR Imaging and Spectroscopy (자궁경부암 진단용 MR 질내표면코일과 전립선암 진단용 MR 경직장표면코일의 제작 : 인체에서의 MR 영상과 MR 분광)

  • 문치웅;조경식
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.481-491
    • /
    • 1995
  • Endovaginal and endorectal receiver only surface coils were designed for MR imaging (MRI) and $^1H$ MR spectroscopy (MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round corner. Size of the coil wire was empirically determined for 7cm and 4cm along the long and short axis, respectively. The coil wire loop was supported by acryl handle and bent about $150^{\circ}$ at one side of the loop considering the average angle of the cervix to the vagina. We called this as a "spoon-type endovaginal coil". The wire of the endorectal coil was made of the flexible materials so that the wire loop became long elliptic shape by pushing the acryl handle into the plastic tube for the comfort of patients when the coil was inserted into the cervix. Then, the shape was maintained to be circle by popping out handle. Conventional spin echo (SE) and fast spin echo (FSE) sequences were used as 71 and 72 weighted imaging sequences, respectively. Matrix size was 128~$256{\times}256$. FOVs for surface coil and body coil were 14cm and 24cm, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method with the following parameters . TR=3 sec, TE=135 msec for PRESS or 30 msec for STEAM, NEX=2, NS=48, Sl=2048, and SW=2500 Hz. Using home-built endovaginal and endorectal coils, excellent T1- and T2-images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo IH MRS was useful to differentiate the cancerous tissue from the normal tissue.

  • PDF