• 제목/요약/키워드: MRI CA

검색결과 27건 처리시간 0.021초

Gold Nanoparticles Coated with Gd-Chelate as a Potential CT/MRI Bimodal Contrast Agent

  • Sk Md., Nasiruzzaman;Kim, Hee-Kyung;Park, Ji-Ae;Chang, Yong-Min;Kim, Tae-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권5호
    • /
    • pp.1177-1181
    • /
    • 2010
  • The synthesis and characterization of gold nanoparticles coated by Gd-chelate (GdL@Au) is described, where L is a conjugate of DTPA (DTPA = diethylenetriamine-N,N,N',N",N"-pentaacetic acid) and 4-aminothiophenol. These particles are obtained by the replacement of citrate from the gold nanoparticle surfaces with gadolinium chelate (GdL). The average size of GdL@Au is 12 nm with a loading of GdL reaching up to $1.4{\times}10^3$ per particles, and they demonstrate very high r1 relaxivity (${\sim}10^4mM^{-1}s^{-1}$) and the r1 relaxivity per [Gd] is as high as $10mM^{-1}s{-1}$. Here, we also describe the use of bimodality of this contrast agent (CA) as a highly efficient CT contrast agent based on gold nanoparticles (GNPs) that overcome the limitations of iodine based contrast agent. The MTT assay performed on this CAs reveals the cytotoxicity as low as that for Omniscan$^{(R)}$ in the concentration range required to obtain intensity enhancement in the in vivo MRI study.

Mg-Al 합금의 크리프 거동에 미치는 합금원소의 영향 (Effect of Alloying Elements on Creep Behavior of Mg-Al Alloys)

  • 임현규;김세광;김도향
    • 한국주조공학회지
    • /
    • 제32권1호
    • /
    • pp.44-49
    • /
    • 2012
  • In this study, three magnesium alloys were investigated; those are 1.5wt.% CaO added AM80, 1.0wt.% CaO added AM60, and conventional MRI153 alloys. Test specimens of three alloys were prepared by re-melting and casting into steel mold with ingots and machining. The mechanical properties and the creep behavior at 150 degrees Celsius of these specimens were determined and their microstructures were characterized using OM and SEM. For the application to die-casting, fluidity test were carried out with spiral mold. Compared with 1.0wt.% CaO added AM60 alloy, 1.5wt.% CaO added AM80 alloy exhibited good creep properties in all test conditions. Moreover, CaO added alloys showed better creep properties than MRI153 alloy at lower load condition. It is proposed that 1.5wt.% CaO added AM80 alloy is useful to apply to power-train parts such as transmission case in vehicles.

Gadolinium Complexes of Bifunctional Diethylenetriaminepentaacetic Acid (DTPA)-bis(amides) as Copper Responsive Smart Magnetic Resonance Imaging Contrast Agents (MRI CAs)

  • Nam, Ki Soo;Park, Ji-Ae;Jung, Ki-Hye;Chang, Yongmin;Kim, Tae-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권10호
    • /
    • pp.2900-2904
    • /
    • 2013
  • We present the synthesis and characterization of DTPA-bis(histidylamide) (1a), DTPA-bis(aspartamide) (1b), and their gadolinium complexes of the type $[Gd(L)(H_2O)]$ (2a:L = 1a; 2b:L = 1b). Thermodynamic stabilities and $R_1$ relaxivities of 2a-b compare well with Omniscan$^{(R)}$, a well-known commercial, extracellular (ECF) MRI CA which adopts the DTPA-bis(amide) framework for the chelate: $R_1$ = 5.5 and 5.1 $mM^{-1}$ for 2a and 2b, respectively. Addition of the Cu(II) ion to a solution containing 2b triggers relaxivity enhancement to raise $R_1$ as high as 15.3 $mM^{-1}$, which corresponds to a 300% enhancement. Such an increase levels off at the concentration beyond two equiv. of Cu(II), suggesting the formation of a trimetallic ($Gd/Cu_2$) complex in situ. Such a relaxivity increase is almost negligible with Zn(II) and other endogenous ions such as Na(I), K(I), Mg(II), and Ca(II). In vivo MR images and the signal-to-noise ratio (SNR) obtained with an aqueous mixture of 2b and Cu(II) ion in an 1:2 ratio demonstrate the potentiality of 2 as a copper responsive MRI CA.

Gd-Complexes of DTPA-bis(amides) Functionalized by Pyridine and Picolinamide: Synthesis, Thermodynamic Stability, and Relaxivity Properties

  • Sk, Nasiruzzaman;Park, Ji-Ae;Chang, Yong-Min;Kim, Tae-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권6호
    • /
    • pp.1211-1216
    • /
    • 2008
  • A series of DTPA-bis(amides) functionalized by pyridine (1a-c) and N-phenylpicolinamide) (1d-e) and their Gd(III)-complexes of the type [Gd(1)($H_2O$)]·x$H_2O$ (2a-e) were prepared and characterized by analytical and spectroscopic techniques. Potentiality of 2a-e as contrast agents for magnetic resonance imaging (MRI CA) was investigated by measuring relevant physicochemical properties and relaxivities and compared with [Gd(DTPA-BMA)($H_2O$)] (DTPA-BMA=N,N''-di(methylcarbamoylmethyl)diethylenetriamine-N,N',N''-triacetate) ($Omniscan^{(R)}$). The R1 relaxivities of aqueous solutions of 2a-c are in the range of 3.33 -5.02 $mM^{-1}$$sec^{-1}$, which are comparable with those of $Omniscan^{(R)}$ (r1=4.58 $mM^{-1}sec^{-1}$). Complexes 2d-e, insoluble in water, exhibit relatively higher R1 values (8.1- 8.3 $mM^{-1}sec^{-1}$) in HP-$\beta$-CD solutions.

국내 주요 기관의 건강진단 검사 종목

  • 조한익;김상인
    • 한국건강관리협회지
    • /
    • 제2권1호
    • /
    • pp.9-25
    • /
    • 2004
  • Along with a development of medical technology, a variety of tests, such as laboratory tests, x-ray and endoscopies are being used in health screening tests. As the tests determine the quality of health screening, test items of major health screening program in Korea. Most, of the health screening programmes focused upon detection of risk factors and diagnosis of life-style related diseases(diabetes, hypertension, cardiovascular diseases, hypercholesterolemia, overweight, drinking, smoking, cerebrovascular diseases, osteoporosis), cancers(stomach, cervix, lung, breast, liver, colon, prostate, ovary, pancreas, thyroid, esophagus), infections diseases(hepatitis, tuberculosis, sexually-transmitted diseases, parasites), chronic obstructive respiratory diseases, chronic renal diseases(bacteriuria, hematuria, proteinuria), anemia, glaucoma, hearing loss, Alzheimer disease, stress and earlypsychiatric diseases. The health screening tests were basic physical examination, basic laboratory tests( CBC, urinalysis, liver function tests, lipid tests, glucose, HbA1c, uric acid, electrolytes, serological tests(HBsAg, HBs-Ab, HCV-Ab, HIV-Ab, VDRL) EKG, x-ray(chest PA, CT) endoscopy(gastroscopy, colonoscopy), sonography (abdomen, thyroid, pelvis, breast), cytology(cervix), bone density, tumor markers(NMP22, alpha-FP, CEA, CA-19-9, CA125, PSA and eye tests. Advanced technologies, like CT, PET, MRI, MRI/Angio, molecular testing were widly used in hospital based health screening programmes. In summary, a variety of tests were untilized in health screening in Korea. Those tests were utilized by stages or according to sex and age in most of health screening programmes, however a few programs used tests excessvely disregarding health screening subjects.

  • PDF

In vivo Imaging Biodistribution Profile of a New Macrocyclic Gadolinium Chelate as a Highly Stable Multifunctional MRI Contrast Agent

  • Sung, Bo Kyung;Jo, Yeong Woo;Chang, Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권1호
    • /
    • pp.34-37
    • /
    • 2019
  • Gadolinium contrast agents (CAs) are integral components of clinical magnetic resonance imaging (MRI). However, safety concerns have arisen regarding the use of gadolinium CAs, due to their association with nephrogenic systemic fibrosis (NSF). Furthermore, recently the long-term retention of $Gd^{3+}-based$ CAs in brains patients with normal renal function raised another possible safety issue. The safety concerns of $Gd^{3+}-based$ CAs have been based on the ligand structure of $Gd^{3+}-based$ CAs, and findings that $Gd^{3+}-based$ CAs with linear ligand structures showed much higher incidences of NSF and brain retention of CAs than $Gd^{3+}-based$ CAs with macrocyclic ligand structure. In the current study, we report the in vivo biodistribution profile of a new highly stable multifunctional $Gd^{3+}-based$ CA, with macrocyclic ligand structure (HNP-2006). MR imaging using HNP-2006 demonstrated a significant contrast enhancement in many different organs. Furthermore, the contrast enhanced tumor imaging using HNP-2006 confirmed that this new macrocyclic CA can be used for detecting tumor in the central nervous system. Therefore, this new multifunctional HNP-2006 with macrocyclic ligand structure shows great promise for whole-body clinical application.

Independent Component Analysis를 이용한 fMRI신호 분석 (Analysis of fMRI Signal Using Independent Component Analysis)

  • 문찬홍;나동규;박현욱;유재욱;이은정;변홍식
    • Investigative Magnetic Resonance Imaging
    • /
    • 제3권2호
    • /
    • pp.188-195
    • /
    • 1999
  • fMRI의 신호는 매우 다양한 종류의 선호들이 혼합된 상태이며 , 비록 몇 가지의 요소에 대해 모델링하여 그 선호 형태를 추측할 수 있으나 모든 신호를 정확하게 분리하여 뇌신경의 활성화를 반영하는 신호만을 선택적으로 알아 내기는 어려운 일이다. 또한 뇌와 신체의 생리적 현상으로 발생하는 잡음뿐아니라 움직임이나 계기의 잡음은 fMRl의 데이터 분석을더욱 어렵게 한다. 따라서 실제 뇌신경의 활성화를 정확히 나타내는 참고데이터(reference data)를 선택하는 것은 힘든 일이며, 뇌신경의 활성화를 반영하는 의미 있는 여러 신호 형태에 대한 분석은 현재 fMRl의 후처리 (post-processing) 분석 방법에서 하나의 연구 과제라 할 수 있다. 본 연구에서는 prioriknow­-ledge 혹은 참고 데이터가 필요 없는 분석 방법인 Independent Component Analysis (lCA) 를 이용하여 fMRI선호를 분석하였다. ICA는 현재 많이 사용되고 있는 상관 분석 방법에 비해 신호의 형태를 분석하는 데에 보다 효과적일 수 있으며, 지연된 반응 형태를 갖는 신호나 움직임에 의한 신호의 패턴을 분리하여 분석할 수 있다. 한편, ICA만으후 fMRl의 신호에 따라 분석이 효과적이지 못한 경우 Principal Component Analysis(PCA) threshold, wavelet spatial f filtering, 부분적 영상 분석 방법들을 ICA전에 수행 함으로써 보다 효과적인 분석을 수행할 수 있다. ICA는 fMRl 신호의 형태 분석에 효과적인 방법이라고 생각하며, 데이터의 자유도를 감소 하기 위해서는 선 필터링 (pre-filtering) 방법들이 적용될 수 있다.

  • PDF

Clinical Application of Serum Tumor Abnormal Protein (TAP) in Colorectal Cancer Patients

  • Wu, Xue-Yan;Huang, Xin-En
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권8호
    • /
    • pp.3425-3428
    • /
    • 2015
  • Objective: To explore the association of serum tumor abnormal protein (TAP) with other serological biomarkers e.g. carcinoembryonic antigen (CEA), carbohydrate antigen 125 (CA125), carbohydrate antigen 19-9 (CA19-9) and its clinical application in colorectal cancer (CRC) patients. Methods: Patients (N=98) were enrolled into this study with histologically or cytologically confirmed CRC. Using a test kit, the level of TAP was determined, while chemiluminescence was used to measure the levels of some other common serological biomarkers e.g. CEA, CA125 and CA19-9. Results: The area of TAP condensed particulate matter decreased after chemotherapy compared with before chemotherapy when CT or MRI scans showed disease control. In contrast, it increased with disease progression (P<0.05). Furthermore, a statistically significant difference was confirmed in monitoring of TAP and common serological biomarkers e.g. CEA and CA19-9 (p<0.05). Conclusions: Detecting TAP in CRC patients has high sensitivity and specificity and can be used as a new independent indicator for clinically monitoring CRC patients in the course of chemotherapy.

Gadolinium Complex of 1,4,7,10-Tetraazacyclododecane-1,4,7-trisacetic acid (DO3A) Conjugate of [(p-aniline benzothiazole)methyl]pyridine as a Tumor-Targeting MRI Contrast Agent

  • Nam, Ki Soo;Jung, Ki-Hye;Chang, Yongmin;Kim, Tae-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권12호
    • /
    • pp.3654-3658
    • /
    • 2013
  • The synthesis of a DO3A conjugate of [(p-aniline benzothiazole)methyl]pyridine ($L^2H_3$) and its gadolinium complex of the type [$Gd(L^2)(H_2O)$] ($GdL^2$) is described. The $R_1$ relaxivity ($=4.50mM^{-1}sec^{-1}$) and kinetic inertness of $GdL^2$ compares well with those of structurally analogous Dotarem$^{(R)}$ ($R_1=3.70mM^{-1}sec^{-1}$), a typical extracellular (ECF) MRI contrast agent (CA). Yet, by comparison with Dotarem$^{(R)}$, $GdL^2$ exhibits non-covalent interactions with human serum albumin (HSA) as evidenced by the ${\varepsilon}^*$ titration curve along with in vivo MR signal enhancement in both aorta and heart. Liver-specific nature of $GdL^2$ is also observed as excretion is made through gallbladder. Most notably, $GdL^2$ further demonstrates specificity toward the MDA-MB-231 breast cancer.