• Title/Summary/Keyword: MRI 영상

Search Result 1,902, Processing Time 0.022 seconds

Evaluation of Combined Contrast Agent using N-(p-maleimidophenyl) Isocyanate Linker-mediated Synthesis for Simultaneous PET-MRI (동시 PET-MRI를 위한 N-(p-maleimidophenyl) isocyanate linker-매개 합성을 이용한 복합 조영제의 평가)

  • Lee, Gil-Jae;Lee, Hwun-Jae;Lee, Tae-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.103-113
    • /
    • 2022
  • In this paper, a combined 18F-FDG(fluorodeoxyglucose) and MNP(magnetic nanoparticles) contrast agent was synthesized using N-(p-maleimidophenyl) isocyanate as the crosslinker for use in simultaneous PET-MRI scans. PET-MRI images were acquired and evaluated before and after injection of the combined contrast imaging agent (18F-FDG labeled MNP) from a glioma stem cell mouse model. After setting the region of interest (ROI) on each acquired image, the area of the lesion was calculated by segmentation. As a result, the PET image was larger than the MRI. In particular, the simultaneous PET-MRI images showed accurate lesions along with the surrounding soft tissue. The mean and standard deviation values were higher in the MRI images alone than in the PET images or the simultaneous PET-MRI images, regardless of whether the contrast agent was injected. In addition, the simultaneous PET-MRI image values were higher than for the PET images. For PSNR experiments, the original image was PET Image using 18F-FDG, MRI using MNPs, and MRI without contrast medium, and the target image was simultaneous PET-MRI image using 18F-FDG labeled MNPs contrast medium. As a result, all of them appeared significantly, suggesting that the 18F-FDG labeled MNPs contrast medium is useful. Future research is needed to develop an agent that can simultaneously diagnose and treat through SPECT-MRI imaging research that can use various nuclides.

USABILITY EVALUATION OF PLANNING MRI ACQUISITION WHEN CT/MRI FUSION OF COMPUTERIZED TREATMENT PLAN (전산화 치료계획의 CT/MRI 영상 융합 시 PLANNING MRI영상 획득의 유용성 평가)

  • Park, Do-Geun;Choe, Byeong-Gi;Kim, Jin-Man;Lee, Dong-Hun;Song, Gi-Won;Park, Yeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.127-135
    • /
    • 2014
  • Purpose : By taking advantage of each imaging modality, the use of fused CT/MRI image has increased in prostate cancer radiation therapy. However, fusion uncertainty may cause partial target miss or normal organ overdose. In order to complement such limitation, our hospital acquired MRI image (Planning MRI) by setting up patients with the same fixing tool and posture as CT simulation. This study aims to evaluate the usefulness of the Planning MRI through comparing and analyzing the diagnostic MRI image and Planning MRI image. Materials and Methods : This study targeted 10 patients who had been diagnosed with prostate cancer and prescribed nonhormone and definitive RT 70 Gy/28 fx from August 2011 to July 2013. Each patient had both CT and MRI simulations. The MRI images were acquired within one half hour after the CT simulation. The acquired CT/MRI images were fused primarily based on bony structure matching. This study measured the volume of prostate in the images of Planning MRI and diagnostic MRI. The diameters at the craniocaudal, anteroposterior and left-to-right directions from the center of prostate were measured in order to compare changes in the shape of prostate. Results : As a result of comparing the volume of prostate in the images of Planning MRI and diagnostic MRI, they were found to be $25.01cm^3$(range $15.84-34.75cm^3$) and $25.05cm^3$(range $15.28-35.88cm^3$) on average respectively. The diagnostic MRI had an increase of 0.12 % as compared with the Planning MRI. On the planning MRI, there was an increase in the volume by $7.46cm^3$(29 %) at the transition zone directions, and there was a decrease in the volume by $8.52cm^3$(34 %) in the peripheral zone direction. As a result of measuring the diameters at the craniocaudal, anteroposterior and left-to-right directions in the prostate, the Planning MRI was found to have on average 3.82cm, 2.38cm and 4.59cm respectively and the diagnostic MRI was found to have on average 3.37cm, 2.76cm and 4.51cm respectively. All three prostate diameters changed and the change was significant in the Planning MRI. On average, the anteroposterior prostate diameter decrease by 0.38cm(13 %). The mean right-to-left and craniocaudal diameter increased by 0.08cm(1.6 %) and 0.45cm(13 %), respectively. Conclusion : Based on the results of this study, it was found that the total volumes of prostate in the Planning MRI and the diagnostic MRI were not significantly different. However, there was a change in the shape and partial volume of prostate due to the insertion of prostate balloon tube to the rectum. Thus, if the Planning MRI images were used when conducting the fusion of CT/MRI images, it would be possible to include the target in the CTV without a loss as much as the increased volume in the transition zone. Also, it would be possible to reduce the radiation dose delivered to the rectum through separating more clearly the reduction of peripheral zone volume. Therefore, the author of this study believes that acquisition of Planning MRI image should be made to ensure target delineation and localization accuracy.

Nonuniformity Correction Scheme Based on 3-dimensional Visualization of MRI Images (MRI 영상의 3차원 가시화를 통한 영상 불균일성 보정 기법)

  • Kim, Hyoung-Jin;Seo, Kwang-Deok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.948-958
    • /
    • 2010
  • Human body signals collected by the MRI system are very weak, such that they may be easily affected by either external noise or system instability while being imaged. Therefore, this paper analyzes the nonuniformity caused by a design of the RF receiving coil in a low-magnetic-field MRI system, and proposes an efficient method to improve the image uniformity. In this paper, a method for acquiring 3D bias volume data by using phantom data among various methods for correcting such nonuniformity in MRI image is proposed, such that it is possible to correct various-sized images. It is shown by simulations that images obtained by various imaging methods can be effectively corrected using single bias data.

PSNR Appraisal of MRI Image (MRI 영상의 PSNR 평가)

  • Kang, Kwang-Soo;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.13-21
    • /
    • 2009
  • The Magnetic Resonance Imaging (MRI) systems consist of various parameters. Among them, the image quality can be arguably the most important part of the systems. As the other components in MRI systems have been developed and evolved, the MRI image quality has been advanced remarkably. And, the radiation imaging system is being converted from the Film to the digital method, which drives the computerization of many hospitals. The management of the tremendous radiation images becomes more critical. The data compression is used to store such large data in a network server. When the image files are compressed, the image quality degrades comparing to its original images. Even slight quality degradation of a medical image could cause an erroneous diagnosis, so the images must be handled carefully. This thesis studied the image assessment methods of comparing the quality of the compressed image to its original, and the quality of the original and the displayed images of the MRI systems via PSNR with actual medical images used in hospitals. As a result, no noticeable quality degradation was found comparing the compressed images with various digital compression methods and the original images. However, it was a different story comparing the original images and the displayed images on MRI monitors. Some noise or image distortion was visible using any regular CRT or LCD monitors were used while the special monitors designed for the MRI imaging and medical images displayed high definition images.

  • PDF

Recent Updates of Abbreviated MRI for Hepatocellular Carcinoma Screening (간세포암 감시를 위한 단축 자기공명영상의 최신지견)

  • Jeong Woo Kim;Chang Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.280-297
    • /
    • 2021
  • International guidelines recommended screening with ultrasonography (US) every 6 months for patients at risk for hepatocellular carcinoma (HCC). However, US demonstrates low sensitivity for the early detection of HCC. Magnetic resonance imaging (MRI) plays an important role in the noninvasive diagnosis of HCC, but it is not suitable for surveillance due to its lengthy examination and high cost. Therefore, several studies have been using various abbreviated MRI strategies, including noncontrast abbreviated MRI, dynamic contrast-enhanced abbreviated MRI, and abbreviated MRI using hepatobiliary phase image for HCC surveillance. In this article, we aim to review these various strategies and explore the future direction of HCC surveillance considering the cost-effectiveness aspect.

Adnexal Masses: Clinical Application of Multiparametric MR Imaging & O-RADS MRI (난소-자궁부속기 종괴: 다중기법 MR 영상의 임상 적용과 O-RADS MRI)

  • So Young Eom;Sung Eun Rha
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1066-1082
    • /
    • 2021
  • Incidental adnexal masses considered indeterminate for malignancy are commonly observed on ultrasonography. Multiparametric MRI is the imaging modality of choice for the evaluation of sonographically indeterminate adnexal masses. Conventional MRI enables a confident pathologic diagnosis of various benign lesions due to accurate tissue characterization of fat, blood, fibrous tissue, and solid components. Additionally, functional imaging sequences, including perfusion- and diffusion-weighted imaging, improve the diagnostic efficacy of conventional MRI in differentiating benign from malignant adnexal masses. The ovarian-adnexal reporting and data system (O-RADS) MRI was recently designed to provide consistent interpretations in assigning risk of malignancy to ovarian and other adnexal masses, and to provide a management recommendation for each risk category. In this review, we describe the clinical application of multiparametric MRI for the evaluation of adnexal masses and introduce the O-RADS MRI risk stratification system.

A New Healthcare Policy in Korea Part 1: Expanded Reimbursement Coverage of Brain MRI, Brain/Neck MRA, and Head and Neck MRI by National Health Insurance (새로운 건강보험 보장성 강화 대책 1부: 뇌 MRI, 뇌혈관/경부혈관 MRA, 두경부 MRI 급여 확대)

  • Eunhee Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1053-1068
    • /
    • 2020
  • In accordance with the new healthcare policy of government (Moon Jae-In Care) to strengthen health insurance coverage, the National Health Insurance (NHI) coverage of brain magnetic resonance imaging (MRI), brain/neck MR angiography (MRA), and head and neck MRI have been expanded since 2018 in Korea. This article has been reviewed focusing on the "Detailed matter concerning criteria and method for providing reimbursed services in the NHI. Some revisions" regarding reimbursement for MRI, which was revised from October 2018 to April 2020 and is currently in effect. It included the MRI reimbursement system in Korea, recent adjustment of the reimbursement coverage for patients with headache or dizziness, and reimbursement coverage, standard imaging, and radiologic report of brain MRI, brain/neck MRA and head and neck MRI. This article could help radiologists gain knowledge on health insurance to protect the expertise of the radiologist and to play a leading role in the hospital. As the policy changes, detailed matter concerning criteria and method for providing reimbursed services in the NHI may be revised. Therefore, radiologists should update issues related to insurance reimbursement for MRI continuously.

Optimization of MRI Protocol for the Musculoskeletal System (근골격계 자기공명영상 프로토콜의 최적화)

  • Hong Seon Lee;Young Han Lee;Inha Jung;Ok Kyu Song;Sungjun Kim;Ho-Taek Song;Jin-Suck Suh
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.21-40
    • /
    • 2020
  • Magnetic resonance imaging (MRI) is an essential modality for the diagnosis of musculoskeletal system defects because of its higher soft-tissue contrast and spatial resolution. With the recent development of MRI-related technology, faster imaging and various image plane reconstructions are possible, enabling better assessment of three-dimensional musculoskeletal anatomy and lesions. Furthermore, the image quality, diagnostic accuracy, and acquisition time depend on the MRI protocol used. Moreover, the protocol affects the efficiency of the MRI scanner. Therefore, it is important for a radiologist to optimize the MRI protocol. In this review, we will provide guidance on patient positioning; selection of the radiofrequency coil, pulse sequences, and imaging planes; and control of MRI parameters to help optimize the MRI protocol for the six major joints of the musculoskeletal system.

CT and MRI image fusion reproducibility and dose assessment on Treatment planning system (치료계획시스템에서 전산화단층촬영과 자기공명영상의 영상융합 재현성 및 선량평가)

  • Ahn, Byeong Hyeok;Choi, Jae Hyeok;Hwang, Jae ung;Bak, Ji yeon;Lee, Du hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.33-41
    • /
    • 2017
  • Objectives: The aim of this study is to evaluate the reproducibility and usefulness of the images through the fusion of CT(Computed tomography) and MRI(Magnetic resonance imaging) using a self-manufactured phantom. We will also compare and analyze the target dose from acquired images. Materials and Methods: Using a self-manufactured phantom, CT images and MRI images are acquired by 1.5T and 3.0T of different magnetic fields. The reproducibility of the size and volume of the small holes present in the phantom is compared through the image from CT and 1.5T and 3.0T MRI, and dose changes are compared and analyzed on any target. Results: 13 small hole diameters were a maximum 31 mm and a minimum 27.54 mm in the CT scan and the were measured within an average of 29.28 mm 1 % compared to actual size. 1.5 T MRI images showed a maximum 31.65 mm and a minimum 24.3 mm, the average is 28.8 mm, which is within 1 %. 3.0T MRI images showed a maximum 30.2 mm and a minimum 27.92 mm, the average is 29.41 mm, which is within 1.3 %. The dose changes in the target were 95.9-102.1 % in CT images, 93.1-101.4 % in CT-1.5T MRI fusion images, and 96-102 % in CT-3.0T MRI fusion images. Conclusion: CT and MRI are applied with different algorithms for image acquisition. Also, since the organs of the human body have different densities, image distortion may occur during image acquisition. Because these inaccurate images description affects the volume range and dose of the target, accurate volume and location of the target can prevent unnecessary doses from being exposed and errors in treatment planning. Therefore, it should be applied to the treatment plan by taking advantage of the image display algorithm possessed by CT and MRI.

  • PDF

Usefulness of MRI Scoring System for Differential Diagnosis between Xanthogranulomatous Cholecystitis and Wall-Thickening Type Gallbladder Cancer (황색육아종성 담낭염과 벽비후형 담낭암의 감별진단을 위한 자기공명영상 점수체계의 유용성)

  • Soul Han;Young Hwan Lee;Youe Ree Kim;Eun Gyu Soh
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.147-160
    • /
    • 2024
  • Purpose To define an MRI scoring system for differentiating xanthogranulomatous cholecystitis (XGC) from wall-thickening type gallbladder cancer (GBC) and compare the diagnostic performance of the scoring system with the visual assessment of radiologists. Materials and Methods We retrospectively analyzed 23 and 35 patients who underwent abdominal MRI and were pathologically diagnosed with XGC and wall-thickening-type GBC after surgery, respectively. Three radiologists reviewed all MRI findings. We defined a scoring system using these MRI findings for differentiating XGC from wall-thickening type GBC and compared the area under the curve (AUC) of the scoring system with the visual assessment of radiologists. Results Nine MRI findings showed significant differences in differentiating the two diseases: diffuse gallbladder wall thickening (p < 0.001), mucosal uniformity (p = 0.002), intramural T2-high signal intensity (p < 0.001), mucosal retraction (p = 0.016), gallbladder stones (p < 0.001), T1-intermediate to high-signal intensity (p = 0.033), diffusion restriction (p = 0.005), enhancement pattern (p < 0.001), and phase of peak enhancement (p = 0.008). The MRI scoring system showed excellent diagnostic performance with an AUC of 0.972, which was significantly higher than the visual assessment of the reviewers. Conclusion The MRI scoring system showed better diagnostic performance than the visual assessment of radiologists to differentiate XGC from wall-thickening-type GBC.