• Title/Summary/Keyword: MRI/PET

Search Result 229, Processing Time 0.022 seconds

Usefulness of Prone Position on PET-CT in Breast Cancer (유방암 PET-CT 검사에서 Prone(복와위)자세의 유용성 평가)

  • Park, Hoon-Hee;Kim, Sei-Yung;Kim, Jung-Yul;Park, Min-Soo;Lim, Han-Snag;Jung, Suk;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho;Lee, Yung-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.44-48
    • /
    • 2008
  • Purpose: In FDG-PET/CT of breast cancer, a sensitivity was 80~96% and a specificity was 75~95% commonly. It was valuable to identify a cancer in early stage been difficult in Mammography. Most of the PET/CT scans have been examined on supine position, so, the image of breast has been acquired by reconstructed whole body scan image. However, using prone position with a compensator, a shape of breast was reassembly shown to be real by gravity. Therefore, the purpose of this study was to evaluate diagnostic value of prone position in FDG PET-CT of breast cancer. Materials and Methods: 30 female patients with doubtful or positive breast cancer were examined. The PET-CT whole body scan was acquired at 60 minutes after $^{18}F$-FDG injection on Supine position. Then, regional breast spot scan was progressed on prone position using a compensator. Each image was evaluated by physicians blinded to patient's data, and statistical analysis did through SUVs measured in PET-CT images. Results: In 27 of 30 patients, prone position was shown accurate discrimination and diagnostic value, but in another 3 patients had a lesion 1cm below, PET-CT couldn't detect it, unlike MRI. Consequently, prone position distinguished a lesion better than Supine position, because of low degree of metamorphosis by gravity. The SUVs analysis of each position was significant (p value=0.004). Conclusion: In PET-CT of breast cancer, prone position could detect micrometastasis as well as primary lesion, better than supine position. Therefore, this study proposes that any technical change considered morphological feature like prone position can offer adequate and useful diagnostic information, together with complementary quantitative analysis.

  • PDF

A Case of Metastatic Tonsillar Lesion Showing Increased FDG Uptake in the Patient with Advanced Hepatocellular Carcinoma (진행성 간암 환자에서 편도 전이에 FDG 섭취증가를 보인 예)

  • Park, Jung-Mi;Kim, Hee-Kyung;Kim, Sang-Gyune;Kim, Young-Seok
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.70-73
    • /
    • 2008
  • A 65 year-old man with hepatocellulcar carcinoma (HCC) admitted to treat left lower leg swelling and pus discharge suspecting osteomyelitis. MRI of his lower leg revealed the bone metastasis. Whole body FDG PET/CT additionally detected left shoulder and right ilium metastasis. Hematemesis suddenly developed in this patient after 3 weeks. Metastasis of right tonsil was histologically proven. When we reviewed his FDG PET/CT, there was asymmetric mild hypermetabolism in the right tonsil. When focal hypermetabolism is shown in the organ physiologically taking glucose up such as tonsil, we should cautiously assess whole body PET/CT in the examination of distant metastasis. We present a patient with multiple distant metastasis including tonsil from HCC showing increased FDG uptake with the literature review.

Granuloma Resulting from the Cervical Metallic Plate, Masquerading as Posterior Pharyngeal Wall Cancer (하인두 후벽암으로 오인된 경추 내고정 금속판 삽입 후 발생한 육아종 1예)

  • Kim, Seung-Woo;Kim, Young-Bae;Sah, Dae-Jin
    • Korean Journal of Head & Neck Oncology
    • /
    • v.27 no.2
    • /
    • pp.218-221
    • /
    • 2011
  • The anterior approach to the cervical spine surgery is associated with possible complications such as dysphagia, hoarseness and granuloma formation etc. Because of orthopedic metallic plates, the increasing or focal uptake pattern may be demonstrated in $^{18}F$-FDG PET/CT scan. A 67-year-old-man came to our department, complained of dysphagia during the 4 months. He underwent cervical spine surgery three years ago. The CT and MRI findings mimicked typical posterior pharyngeal wall cancer with cervical metastasis. Furthermore, the SUV in $^{18}F$-FDG PET/CT was 10.3. But he was finally diagnosed as a granuloma resulting from the metallic cervical implants. The clinical correlation and medical history should be taken into account to avoid false-positive findings in PET/CT and to avoid many erroneous diagnostic pathways.

Study of Nuclear medical imaging tests patient of Claustrophobia (폐소공포증 환자의 핵의학 영상검사에 관한 연구)

  • Kang, Yong-Gil;Hong, Jin-Woong;Yang, Han-Joon;Park, Sung-Su;Lee, Gui-Won;Kim, Keung-Sik
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.55-59
    • /
    • 2013
  • Patients who had claustrophobia tend to feel fear when they were scanned by an MRI, CT, PET-CT, or using a gamma camera scan. In this paper, claustrophobic patients were tested to find effective ways by changing patient's positions. For this paper, PET-CT scan in patients who had claustrophobia were used in the prone position. Prone position helped to maintain stable position and to get a h0igh quality of inspection without failure. Thus, as claustrophobic patients were requested taking prone position, they could feel comfortable. In a confined space, prone position for the claustrophobic patients who had a fear of the PET-CT examination would be expected to reduce the failure rate of inspection.

  • PDF

Solitary Necrotic Nodule of the Liver Mimicking Metastasis in Patient with Early Gastric Cancer : 3T MRI and PET/CT Findings (조기 위암 환자에서 전이암과 감별이 필요했던 간내 단발성 궤사성 결절: 3T MRI 및 PET/CT 소견)

  • Cho, Woo-Sun;Kim, Gi-Hyeon;Lee, Hwa-Yeon;Lee, Jong-Beum;Kwon, Gui-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.213-217
    • /
    • 2009
  • Solitary necrotic nodule (SNN) of the liver is a very uncommon benign lesion, and it is detected incidentally as a rule. It is important to differentiate SNN radiologically from various single hepatic nodules because SNN mimics hepatic metastasis, especially in staging work up of known primary malignancy. The reported imaging findings of SNN are well-defined nodule without enhancement or with subtle peripheral enhancement. There has been no report about the target-like SNN of the liver and about the imaging finding of 3T magnetic resonance imaging and positron emission tomography. We report a case of targetlike SNN of the liver, mimicking hepatic metastasis, with findings of various imaging modalities and try to find a cause of this nodule according to the pathologic and literature review.

  • PDF

Pelvic insufficiency fracture after radiotherapy in patients with cervical cancer in the era of PET/CT

  • Park, Shin-Hyung;Kim, Jae-Chul;Lee, Jeong-Eun;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.29 no.4
    • /
    • pp.269-276
    • /
    • 2011
  • Purpose: To determine the incidence, risk factors, and clinical characteristics of pelvic insufficiency fracture (PIF) in patients with cervical cancer. Materials and Methods: Between July 2004 and August 2009, 235 patients with non-metastatic cervical cancer were treated with definitive chemoradiation or postoperative radiotherapy. Among 235 patients, 117 (49.8%) underwent the first positron emission tomography/computed tomography (PET/CT) within 1 year after radiotherapy. The median radiation dose was 55 Gy (range, 45 to 60 Gy). Medical charts and imaging studies, including PET/CT, magnetic resonance imaging (MRI), CT. bone scintigraphy were reviewed to evaluate the patients with PIF. Results: Among 235 patients, 16 developed PIF. The 5-year detection rate of PIF was 9.5%. The 5-year detection rate of PIF in patients who underwent the first PET/CT within a year was 15.6%. The median time to development of PIF was 12.5 months (range, 5 to 30 months). The sites of fracture included 12 sacroiliac joints, 3 pubic rami, 3 iliac bones, and 1 femoral neck. Eleven of 16 patients having PIF complained of hip pain requiring medications. One patient required hospitalization for pain control. The significant risk factors of PIF were old age, body mass index less than 23, bone mineral density less than -3.5 SD, and the first PET/CT within a year after radiotherapy. Radiation dose and concurrent chemotherapy had no impact on PIF rate. Conclusion: PIFs were not rare after pelvic radiotherapy in cervical cancer patients in the era of PET/CT. Timely diagnosis and management of PIF can improve quality of life in patients with cervical cancer, in addition to reducing unnecessary medical expenses.

Application and Prospects of Molecular Imaging (분자영상의 적용분야 및 전망)

  • Choi, Guyrack;Lee, Sangbock
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.123-136
    • /
    • 2014
  • In this paper, we study to classify molecular imaging and applications to predict future. Molecular imaging in vivo at the cellular level and the molecular level changes taking place to be imaged, that is molecular cell biology and imaging technology combined with the development of the new field. Molecular imaging is used fluorescence, bioluminescence, SPECT, PET, MRI, Ultrasound and other imaging technologies. That is applied to monitoring of gene therapy, cell tracking and monitoring of cell therapy, antibody imaging, drug development, molecular interaction picture, the near-infrared fluorescence imaging of cancer using fluorescence, bacteria using tumor-targeting imaging, therapeutic early assessment, prediction and therapy. The future of molecular imaging would be developed through fused interdisciplinary research and mutual cooperation, which molecular cell biology, genetics, chemistry, physics, computer science, biomedical engineering, nuclear medicine, radiology, clinical medicine, etc. The advent of molecular imaging will be possible to early diagnosis and personalized treatment of disease in the future.

Effects of Motion Correction for Dynamic $[^{11}C]Raclopride$ Brain PET Data on the Evaluation of Endogenous Dopamine Release in Striatum (동적 $[^{11}C]Raclopride$ 뇌 PET의 움직임 보정이 선조체 내인성 도파민 유리 정량화에 미치는 영향)

  • Lee, Jae-Sung;Kim, Yu-Kyeong;Cho, Sang-Soo;Choe, Yearn-Seong;Kang, Eun-Joo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.413-420
    • /
    • 2005
  • Purpose: Neuroreceptor PET studies require 60-120 minutes to complete and head motion of the subject during the PET scan increases the uncertainty in measured activity. In this study, we investigated the effects of the data-driven head mutton correction on the evaluation of endogenous dopamine release (DAR) in the striatum during the motor task which might have caused significant head motion artifact. Materials and Methods: $[^{11}C]raclopride$ PET scans on 4 normal volunteers acquired with bolus plus constant infusion protocol were retrospectively analyzed. Following the 50 min resting period, the participants played a video game with a monetary reward for 40 min. Dynamic frames acquired during the equilibrium condition (pre-task: 30-50 min, task: 70-90 min, post-task: 110-120 min) were realigned to the first frame in pre-task condition. Intra-condition registrations between the frames were performed, and average image for each condition was created and registered to the pre-task image (inter-condition registration). Pre-task PET image was then co-registered to own MRI of each participant and transformation parameters were reapplied to the others. Volumes of interest (VOI) for dorsal putamen (PU) and caudate (CA), ventral striatum (VS), and cerebellum were defined on the MRI. Binding potential (BP) was measured and DAR was calculated as the percent change of BP during and after the task. SPM analyses on the BP parametric images were also performed to explore the regional difference in the effects of head motion on BP and DAR estimation. Results: Changes in position and orientation of the striatum during the PET scans were observed before the head motion correction. BP values at pre-task condition were not changed significantly after the intra-condition registration. However, the BP values during and after the task and DAR were significantly changed after the correction. SPM analysis also showed that the extent and significance of the BP differences were significantly changed by the head motion correction and such changes were prominent in periphery of the striatum. Conclusion: The results suggest that misalignment of MRI-based VOI and the striatum in PET images and incorrect DAR estimation due to the head motion during the PET activation study were significant, but could be remedied by the data-driven head motion correction.

Usefulness of FDG-PET/CT as a Diagnostic Tool for Routine Post Therapy Evaluation in Endometrial Cancer (자궁내막암의 치료 후 루틴 추적검사 방법으로서 FDG-PET/CT의 유용성)

  • Lee, Shin-Jae;Jeon, Tae-Joo;Kim, Seung-Jo;Kim, Hee-Jin;An, Hee-Jung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.301-308
    • /
    • 2009
  • Purpose: The aim of this study was to evaluate the usefulness of FDG-PET/CT as follow up imaging tool in patients with endometrial cancer after therapy. Material and Methods: One hundred one patients with endometrial cancer who underwent FDG PET/CT after the treatment of this disease were included in this study population (25-79 yr old, Mean age 50.6 yr old) and all these patients also performed various laboratory and imaging studies such as serum tumor marker, CT or MRI. The lesions having increased focal FDG uptake were classified into benign, equivocal, and malignant one according to their pattern and activity. Tumor recurrence was confirmed by histopathological results and other clinical and imaging data. Results: Among the 19 patients with 30 malignant or equivocal hot uptakes, 11 of 14 patients supposed to be malignant finding in PET/CT were proved to be tumor recurrence, while one of 5 patients with equivocal lesions were recurred malignancy, Two false negative cases were turned out to be peritoneal carcinomatosis, Estimated sensitivity, specificity and accuracy of PET/CT for diagnosis of recurrence in endometrial carcinoma after treatment were 86 %, 92 % and 91 %, respectively. Positive and negative predictive values in the same issue were 63% and 98%, respectively. Conclusion: FDG-PET/CT is useful for regular work up of endometrial carcinoma after the treatment because of its high negative predictive value as well as high sensitivity and specificity.

Principal component analysis in C[11]-PIB imaging (주성분분석을 이용한 C[11]-PIB imaging 영상분석)

  • Kim, Nambeom;Shin, Gwi Soon;Ahn, Sung Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.12-16
    • /
    • 2015
  • Purpose Principal component analysis (PCA) is a method often used in the neuroimagre analysis as a multivariate analysis technique for describing the structure of high dimensional correlation as the structure of lower dimensional space. PCA is a statistical procedure that uses an orthogonal transformation to convert a set of observations of correlated variables into a set of values of linearly independent variables called principal components. In this study, in order to investigate the usefulness of PCA in the brain PET image analysis, we tried to analyze C[11]-PIB PET image as a representative case. Materials and Methods Nineteen subjects were included in this study (normal = 9, AD/MCI = 10). For C[11]-PIB, PET scan were acquired for 20 min starting 40 min after intravenous injection of 9.6 MBq/kg C[11]-PIB. All emission recordings were acquired with the Biograph 6 Hi-Rez (Siemens-CTI, Knoxville, TN) in three-dimensional acquisition mode. Transmission map for attenuation-correction was acquired using the CT emission scans (130 kVp, 240 mA). Standardized uptake values (SUVs) of C[11]-PIB calculated from PET/CT. In normal subjects, 3T MRI T1-weighted images were obtained to create a C[11]-PIB template. Spatial normalization and smoothing were conducted as a pre-processing for PCA using SPM8 and PCA was conducted using Matlab2012b. Results Through the PCA, we obtained linearly uncorrelated independent principal component images. Principal component images obtained through the PCA can simplify the variation of whole C[11]-PIB images into several principal components including the variation of neocortex and white matter and the variation of deep brain structure such as pons. Conclusion PCA is useful to analyze and extract the main pattern of C[11]-PIB image. PCA, as a method of multivariate analysis, might be useful for pattern recognition of neuroimages such as FDG-PET or fMRI as well as C[11]-PIB image.

  • PDF