• Title/Summary/Keyword: MR signal

Search Result 437, Processing Time 0.026 seconds

Studies on the Differentiation of Skeletal Muscle Cells in vitro:Protein Kinase C in the Differentiation of Skeletal Muscle Cells (근세포 분화에 관한 연구 : 근세포 분화에 있어서 Protein Kinase C)

  • 최원철;김한도;김정락
    • The Korean Journal of Zoology
    • /
    • v.34 no.2
    • /
    • pp.131-141
    • /
    • 1991
  • Treating 12-O-tetradecanoyIphorboI 13-acetate -TPA) or platelet~derived growth factor(PDGF), the signal transduction of protein Idnase C (PKC) is occurred by the phosphoryladon. However the targeting proteins phosphorylated by PKC were found to be different proteins in molecular weights when WA or PDGF wa~ treated to the myoblast. In the WA-treated myoblast cells, the protein of Mr. 20 I(d was phosphorylated. In the PDGF-treated cells, the protein of Mr. 40 Kd was phosphrylated, while the protein of Mr. 20 Kd which phosphorylated in the WA-treatment was dephosphorylated. These results indicate that not only WA and PDGF &e different in activating the signal transduction pathways, but also they may involve in the down reguladon of PI(C during the long-term treatment But PDGF gave rise more rapidly down reguladon than in the case of WA. Using immunocytochemical approach, two disdnct PKC isozymes, PKC II and PKC III, have been localized in cytoplasm and both cytoplasm and nuclsolus, respectively. Ther'efore, the expression of two types of PKC in the myoblast suggests that the isozymes of PKC may involve in each different pathway of signal transduction or down-reguladon.

  • PDF

Silencing MR-1 attenuates atherosclerosis in ApoE-/- mice induced by angiotensin II through FAK-Akt -mTOR-NF-kappaB signaling pathway

  • Chen, Yixi;Cao, Jianping;Zhao, Qihui;Luo, Haiyong;Wang, Yiguang;Dai, Wenjian
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.22 no.2
    • /
    • pp.127-134
    • /
    • 2018
  • Myofibrillogenesis regulator-1 (MR-1) is a novel protein involved in cellular proliferation, migration, inflammatory reaction and signal transduction. However, little information is available on the relationship between MR-1 expression and the progression of atherosclerosis. Here we report atheroprotective effects of silencing MR-1 in a model of Ang II-accelerated atherosclerosis, characterized by suppression focal adhesion kinase (FAK) and nuclear factor kappaB ($NF-{\kappa}B$) signaling pathway, and atherosclerotic lesion macrophage content. In this model, administration of the siRNA-MR-1 substantially attenuated Ang II-accelerated atherosclerosis with stabilization of atherosclerotic plaques and inhibited FAK, Akt, mammalian target of rapamycin (mTOR) and NF-kB activation, which was associated with suppression of inflammatory factor and atherogenic gene expression in the artery. In vitro studies demonstrated similar changes in Ang II-treated vascular smooth muscle cells (VSMCs) and macrophages: siRNA-MR-1 inhibited the expression levels of proinflammatory factor. These studies uncover crucial proinflammatory mechanisms of Ang II and highlight actions of silencing MR-1 to inhibit Ang II signaling, which is atheroprotective.

Usefulness of Superparamagnetic Iron Oxide (SPIO) as a Negative Oral Contrast Agent in MR Cholangiopancreatography (자기공명 담관췌장초영술에서 음성 경구 조영제로 사용한 초상자성 산화철 제재의 유용성)

  • 이정민;송원규;이종덕
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.49-56
    • /
    • 2001
  • Purpose : To evaluate value of superparamagnetic iron oxide (SPIO) as a negative oral contrast agent in MR cholangiopancreatography (MRCP). Materials and methods : Forty-eight patients with suspected biliary tract or pancreatic diseases and six healthy volunteers were enrolled in this study. All MR images were obtained using a 1.5 T MR unit. MR-CP using fat-suppressed half-Fourier acquisition single-shot turbo spin echo (HASTE) and turbo spin echo (TSE) techniques were performed and reconstructed with maximal intensity projection (MIP). To determine the most optimal concentration of SPIO to obliterate the high signal intensity of water, a phantom experiment was conducted with various concentrations of SPIO-water mixture. Two radiologists evaluated pre- and postcontrast MRCPS. The contrast enhancement was assessed on the basis of loss of signal intensity in the stomach and duodenum. Results : In the phantom experiment, a significant increase of percentage of signal intensity loss (PSIL) occurred in concentration of 22.4 ugFe/ml (Feridex1 ml diluted with water 500 ml). Postcontrast MRCP showed an improved image quality compared with precontrast images. The rate of improvement in the diagnosis of diseases of the common bile duct and pancreatic duct was 25% (12/48). Conclusion : In patients with suspected biliary tract and pancreatic diseases, the SPIO is useful as a negative oral contrast agent for MRCP and provides an improvement of image quality.

  • PDF

MR Findings of Flexor Hallucis Longus Dysfunction (장무지굴근 기능장애의 자기공명영상 소견)

  • Kim, Ji-Eun;Choi, Hye-Young;Choi, Ho-Cheol;Lee, Gyung-Kyu;Jeon, Kyung-Nyeo;Shin, Tae-Beom;Na, Jae-Boem
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.148-152
    • /
    • 2008
  • Purpose : To find the MR findings and evaluate the usefulness of MR in flexor hallucis longus(FHL) dysfunction. Materials and Methods : From 1992 to 2003, fourty patients were found to have surgically confirmed FHL dysfunction. 24 cases of 22 patients who had performed MR were included in this study. We analyzed the signal intensity of FHL tendon and muscle, tendon sheath, sheath effusion, and bone lesions, retrospectively. Results : Non-specific, increased sheath effusion of FHL tendon was seen in 12 cases (50%). Large amount of sheath effusion(grade 3) was observed in 5 cases (21%). The signal intensity of FHL tendon was normal in all cases. High signal intensity at the FHL muscle, proximal to musculotendinous junction was seen in 1 case (4%). One case (4%) of marrow edema of the talus and another one case (4%) of osteochondritis dissecans of the talus was seen. Conclusion : Non-specific, increased sheath effusion of FHL tendon was observed on MR in FHL dysfunction patients. Therefore, MR has a limited role in diagnosis of FHL dysfunction and is useful to exclude other bone and tendon diseases causing medial ankle pain.

  • PDF

High Resolution Time Resolved Contrast Enhanced MR Angiography Using k-t FOCUSS (k-t FOCUSS 알고리듬을 이용한 고분해능 4-D MR 혈관 조영 영상 기법)

  • Jung, Hong;Kim, Eung-Yeop;Ye, Jong-Chul
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.10-20
    • /
    • 2010
  • Purpose : Recently, the Recon Challenge at the 2009 ISMRM workshop on Data Sampling and Image Reconstruction at Sedona, Arizona was held to evaluate feasibility of highly accelerated acquisition of time resolved contrast enhanced MR angiography. This paper provides the step-by-step description of the winning results of k-t FOCUSS in this competition. Materials and Methods : In previous works, we proved that k-t FOCUSS algorithm successfully solves the compressed sensing problem even for less sparse cardiac cine applications. Therefore, using k-t FOCUSS, very accurate time resolved contrast enhanced MR angiography can be reconstructed. Accelerated radial trajectory data were synthetized from X-ray cerebral angiography images and provided by the organizing committee, and radiologists double blindly evaluated each reconstruction result with respect to the ground-truth data. Results : The reconstructed results at various acceleration factors demonstrate that each components of compressed sensing, such as sparsifying transform and incoherent sampling patterns, etc can have profound effects on the final reconstruction results. Conclusion : From reconstructed results, we see that the compressed sensing dynamic MR imaging algorithm, k-t FOCUSS enables high resolution time resolved contrast enhanced MR angiography.

The Usefulness of Diffusion-weighted MR Imaging for Differentiation between Degenerative Spines and Infectious Spondylitis (퇴행성 척추와 감염성 척추염의 감별에 있어서 확산강조영상의 유용성)

  • 박원규;변우목;최준혁
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.152-157
    • /
    • 2002
  • Purpose : The differential diagnosis between Modic type I degenerative spine and infectious spondylitis sometimes is difficult, because the affected bone marrows in both disease show similar signal intensity on conventional MR imaging. We evaluate the usefulness of diffusion-wighted MR imaging for differential diagnosis between Modic type I degenerative spine and infectious spondylitis. Materials and methods : The spin-echo and diffusion-weighted MR images of eight patients with Modic type I degenerative spines and 14 patients with infectious spondylitis diagnosed by clinical findings or CT-guided biopsies we re analyzed. The diffusion-weighted imaging sequence was based on reversed fast imaging with steady-state precession (PSIF). Signal intensity changes of the vertebral bone marrow on conventional spin-echo and diffusion-weighted MR imaging were compared between degenerative spine and infectious spondylitis. Results : On T1-weighte d images, the affeted bone marrow in both disease showed hypointense signals. On T 2-weighted images, all of type I degenerative spine and 11 of infectious spondylitis showed hyperintensity, and three of infectious spondylitis showed heterogeneo us mixed signal intensity. On diffusion-weighted MR images, all of type I degenerative spine were hypointense with peripheral high signal intensity to normal vertebral body, but infectious spondylitis was hyperintense (n = 11) and hypointense (n=3). Conclusion : Diffusion-weighted MR imaging is useful to differentiate Modic type I degenerative spine from infectious spondylitis. On diffusion-weighted images, the high singal intensity of bone marrow suggests infectious spondylitis, whereas the low signal intensity of bone marrow with peripheral focal high signal intensity suggests type I degenerative spine.

  • PDF

Assessment of Osteoporosis Based on Changes in SNR and ADC Values on MR Diffusion Weighted Images (확산강조영상에서 신호대 잡음비, 현성 확산 계수 변화에 따른 골다공증 평가)

  • Cho, Jae-Hwan;Kim, Yeong-Soo
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.70-77
    • /
    • 2010
  • This study tested how S/N (Signal to Noise Ratio) ratios and ADC (apparent diffusion coefficient) values vary with different T-scores in a group of patients with osteoporosis. Based on DEXA (Dual Energy X-ray Absorptiometry) T-scores for L1.L4 for two groups of subjects consisting of 30 healthy people without osteoporosis and 30 patients who came for treatment of waist (lumbar or low back) pain and were suspected to have osteoporosis as judged from the simple X-ray findings, this study classified every spine into two groups of osteoporosis and osteopenia. Signal intensity measurements were made in the four regions of L1 to L4 on diffusion-weighted MR images obtained using 1.5T MR scanner, while ADC measurements were obtained from ADC map images. As an approach for quantitative analysis, the comparison of the variances in S/N ratios and ADC values for varying T-scores in the selected regions of interest was carried out based on averaged T-scores, S/N ratios, and ADC values. Also, the variances in S/N ratios and ADC values for each of the groups of osteoporosis and osteopenia, which were classified into by T-scores, were compared. For qualitative analysis, a careful naked eye examination of signal intensity differences in the area of L4 was made on T1-weighted sagittal images for each of the healthy (normal), osteopenia, and osteoporosis groups. In the qualitative analysis, it was found that for both the osteopenia group and the osteoporosis group, as T-scores deceased, the S/N ratios on diffusion-weighted MR images also decreased, with the greatest decrease in the S/N ratio found in the osteoporosis group. Additionally, among the three groups, the lowest S/N ratio was found in the osteoporosis group. With respect to ADC map, it was found that for both the osteopenia group and the osteoporosis group, as T-scores deceased, the ADC values on diffusion-weighted MR images also decreased, with the greatest decrease in the ADC values found in the osteoporosis group. Additionally, among the three groups, the lowest ADC value was found in the osteoporosis group. On the other hand, in the qualitative analysis, the osteoporosis group showed the highest signal intensity. Additionally, among the three groups, the lowest signal intensity was found in the healthy (normal) group. It was found that as osteoporosis progressed, S/N ratio and ADC decreased, whereas signal intensity increased on T1-weighted images. Also, in diagnosing osteoporosis, MRI tests turned out to be (more) effective.

Carotid Intraplaque Hemorrhage Imaging: Diagnostic Value of High Signal Intensity Time-of-Flight MR Angiography Compared with Magnetization-Prepared Rapid Acquisition with Gradient-Echo Sequencing

  • Ahn, Ji-eun;Kwak, Hyo Sung;Chung, Gyung Ho;Hwang, Seung Bae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.94-101
    • /
    • 2018
  • Purpose: To determine the value of the appearance of the high signal intensity halo sign for detecting carotid intraplaque hemorrhage (IPH) on maximum intensity projection (MIP) of time-of-flight (TOF) MR angiography (MRA), based on high signal intensity on magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) sequencing. Materials and Methods: A total of 78 carotid arteries in 65 patients with magnetization-prepared rapid acquisition gradient-echo (MPRAGE) positive on carotid plaque MR imaging were included in this study. High-resolution MR imaging was performed on a 3.0-T scanner prior to carotid endarterectomy or carotid artery stenting. Fast spin-echo T1- and T2-weighted axial imaging, TOF, and MPRAGE sequences were obtained. Carotid plaques with high signal intensity on MPRAGE > 200% that of adjacent muscle on at least two consecutive slices were defined as showing IPH. Halo sign of high signal intensity around the carotid artery was found on MIP from TOF MRA. Continuous and categorical variables were compared among groups using the Mann-Whitney test and Fisher's exact tests. Results: Of these 78 carotid arteries, 53 appeared as a halo sign on the TOF MRA. The total IPH volume of patients with a positive halo sign was significantly higher than that of patients without a halo sign ($75.0{\pm}86.8$ vs. $16.3{\pm}18.2$, P = 0.001). The maximum IPH axial wall area in patients with a positive halo sign was significantly higher than that of patients without a halo sign ($11.3{\pm}9.9$ vs. $3.7{\pm}3.6$, P = 0.000). Conclusion: High signal intensity halo of IPH on MIP of TOF MRA is associated with total volume and maximal axial wall area of IPH.

Extending the Read Range of UHF Mobile RFID Readers: Arbitration Methods Based on Interference Estimation

  • Ahn, Si-Young;Park, Jun-Seok;Seong, Yeong Rak;Oh, Ha-Ryoung
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2025-2035
    • /
    • 2014
  • The read range of UHF mobile readers can be extended by a booster for mobile RFID readers (BoMR). But in an environment where multiple BoMRs are installed, the read success rate may be decreased due to signal interference. This paper proposes three arbitration methods based on interference estimation with the purpose of enhancing the read success rate. A central arbitration server manages global information in centralized arbitration method (CAM) without broadcast/multicast communication facility. In fully distributed arbitration method (FDAM), all the arbitration messages are broadcasted from a BoMR to every BoMR, and each BoMR decides with broadcasted global information. Events in FDAM are serialized naturally with broadcasted messages. Cluster Distributed Arbitration Method (CDAM) forms clusters with multicasted BoMRs and a selected BoMR acts as an arbiter in the cluster. Such effects as lengthened read range, improved the read success rates of readers can be obtained by the proposed methods without any hardware modification. In order to evaluate the arbitration methods, the RFID system is modeled by using the DEVS formalism and simulated by using the DEVSim++.

Semi-active fuzzy based control system for vibration reduction of a SDOF structure under seismic excitation

  • Braz-Cesar, Manuel T.;Barros, Rui C.
    • Smart Structures and Systems
    • /
    • v.21 no.4
    • /
    • pp.389-395
    • /
    • 2018
  • This paper presents the application of a semi-active fuzzy based control system for seismic response reduction of a single degree-of-freedom (SDOF) framed structure using a Magnetorheological (MR) damper. Semi-active vibration control with MR dampers has been shown to be a viable approach to protect building structures from earthquake excitation. Moreover, intelligent damping systems based on soft-computing techniques such as fuzzy logic models have the inherent robustness to deal with typical uncertainties and non-linearities present in civil engineering structures. Thus, the proposed semi-active control system uses fuzzy logic based models to simulate the behavior of MR damper and also to develop the control algorithm that computes the required control signal to command the actuator. The results of the numerical simulations show the effectiveness of the suggested semi-active control system in reducing the response of the SDOF structure.