• Title/Summary/Keyword: MR signal

Search Result 437, Processing Time 0.03 seconds

Metabolic Changes in Pericontusional Edematous Areas in Mild Head Injury Evaluated by Proton MRS (경도 두부외상 환자에서 뇌좌상주위 부종영역에서의 자기공명분광법을 이용한 대사변화)

  • Hong, Sang-Su;Son, Byung-Chul;Cho, Byung Gil;Kim, Euy-Nyeng;Kim, Bum-Soo;Park, Chun-Kum;Choe, Bo-Young;Kim, Moon-Chan;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.9
    • /
    • pp.1233-1237
    • /
    • 2000
  • Objectives : In order to evaluate the metabolic changes associated with pericontusional edematous area in mild head injury, proton magnetic resonance spectroscopy(1H-MRS) was performed in mild head injury patients (initial GCS score 13-15) with focal brain contusion. Methods : Seven head injury patients with initial GCS 13-15(3 males and 4 females : age range 15-65 years, mean age 33 years) have underwent 1H-MRS evaluations. The patients were examined within 7 days after injury(n=7) and 2 months after injury(n=5). The region of interest(ROI) was selected in the edematous area adjacent to traumatic brain contusion upon T2-weighted MR images and a corresponding region of the contralateral hemisphere (ROC, region of contralateral corresponding hemisphere) was examined as well. The metabolic ratios of NAA/Cr and lactate/Cr were compared between ROIs, ROCs and control values. Results : In initial NAA/Cr ratios, the values of ROIs were significantly lower than those of the controls(p=0.009), but there was no difference either between ROIs and ROCs(p=0.410) or between ROCs of patients and the control (p=0.199). In lactate/Cr ratios, the ROIs in all seven patients and the ROCs in two showed increased lactate signals. The lactate/Cr ratios of the ROIs were significantly elevated as compared to those of the ROCs(p=0.02) and the control(p=0.015). In two months follow-up, lactate signals were absent or significantly reduced(p=0.015). In no patients, clinical or radiological deterioration has been observed. Conclusion : Our 1H-MRS results demonstrate that there are significant ischemic changes in pericontusional edematous areas as indicated by elevated lactate signals in the patients with mild head injury. But there were no consistent neural loss or dysfunction in these area. There findings suggest that pericontusional edematous areas can be vulnerable to secondary brain insults even in the patients with mild head injury.

  • PDF

Global Cerebral Ischemia in a Beagle Dog (비글견에서 발생한 전반적 대뇌허혈)

  • Choi, Ho-Jung;Choi, Soo-Young;An, Ji-Young;O, I-Se;Jeong, Seong-Mok;Cho, Sung-Whan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.26 no.1
    • /
    • pp.104-108
    • /
    • 2009
  • Global cerebral ischemia occurs commonly in patients who have a variety of clinical conditions including cardiac arrest and shock. Cerebral ischemia results in a rapid depletion of energy stores that triggers resulting in excitotoxic death. Imaging studies of the brain with computed tomography(CT) or magnetic resonance imaging(MRI) are necessary to confirm the clinical neurolocalization, identify any associated mass effect, and rule out other causes of focal brain disorders. Cardiopulmonary arrest was occurred by propofol anesthesia in a 1 year old, intact female Beagle dog. After successful cardiopulmonary resuscitation was performed within 5 minutes, clinical signs such as vocalization, paddling, opisthotonus and seizure were represented. At the 12th day, CT and MRI examinations of the brain were performed to evaluate the brain. After euthanasia, histopathologic examination was performed. On transverse image of CT, lesions appeared as a hypodense in the right dorsal surface of the frontal lobe and level of optic canal, and dorsomedial surface of occipital lobe of cerebrum. No contrast enhancement was represented following intravenous contrast administration. On MR images of brain, the lesions were seen as a hyperintense on T2-weighted(T2W) images and a isointense or mild hypointense on T1-weighted(T1W) images. Hyperintense lesions both T2W and T1W images were observed at the surrounding cerebral sulcus. There was no significant signal changes on contrast T1WI. Histopathologic examination after euthanasia revealed that the lesion was necrosis of the cerebral cortex caused by cerebral ischemia.

Fractional Anisotropy of Diffusion Tensor Imaging as a Predict Factor in Patient with Acute Cerebral Infarction (급성 뇌경색 환자에서 예후 추측인자로서의 확산텐서영상 비등방도)

  • Kim, Sung-Gil;Eun, Sung-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.13-18
    • /
    • 2010
  • Purpose : Diffusion tensor imaging(DTI) allows the visualization of fiber tract damage in patients with cerebral infarction. The purpose of this study is to evaluate the correlation between degree of NIH stoke scale and fractional anisotropy (FA) in patient with cerebral infarction. Material and Methods : 16 patients aged 36~77 years(male : 11, female : 5, mean age : 61y), diagnosed cerebral infarction by diffusion weighted imaging(DWI), underwent 24 directional diffusion tensor imaging(DTI). Patients had the DTI taken within 3days of stroke onset. Comparison of DWI, FA value on DTI were measured infarcted area and counter part of specific region of interest (ROI). And evaluation of differences between clinically improved patient group (n=9) and unimproved patient group (n=7) until 2 week follow up after development of cerebral infarction. Clinical status was scaled by NIH stroke scale. Results : Quantitative measurements of FA confirmed statistically the significant diffusion changes in the infarct compared with the matched-counter part region. In DWI, the infarcted area shows high signal intensity, however FA value on DTI was lower than normal brain parenchyma. The FA value of clinically improved patient by NIH stroke scale was 0.49, and the value of contralateral normal brain parenchyma was 0.41. On the contrary, FA value of infarcted area shows about 15% lower than normal brain parenchyma. But, the FA value of unimproved patient by NIH stroke scale represents a half those of contralateral normal brain parenchyma (0.28 on infarcted area vs. 0.56 on normal brain parenchyma). So, the FA value of unimproved patient group was considerably less than those of improved. Conclusion : It is concluded that the unimproved patient group after cerebral infarction showed much less FA value than that of normal brain parenchyma. The FA value of DTI may be one of the useful parameter to predict outcome of cerebral infarction patients.

A Study on Experimental Analysis of Dynamic properites for Structure and its Application (구조물 동특성의 실험적 해석과 응용기술에 관한 연구 (기계식 주차설비 진동제어))

  • 이홍기;박상규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.04a
    • /
    • pp.40-45
    • /
    • 1993
  • 일반적으로 건물 구조물에 전달되는 기계진동을 감소시키기 위해서 기계와 기초사이에 유연한 방진소자를 삽입하여 기계가진력(exciting force)의 전달 률을 줄인다. 또한 구조물의 고유진동수와 진동원의 가진주파수가 일치할 경 우, 가진주파수를 변화시키거나, 구조물의 동특성을 변화시키는 방법을 사용 한다. 어떠한 방안을 선택하든 효과적이고 정량적인 방진 시스템을 구성하고 구조물의 정확한 진동상태를 예측하기 위해서는 진동원의 가진특성과 구조 물의 동특성에 대한 정보가 요구된다. 일반적으로 방진설계를 위해 필요한 진동원의 가진특성은 제조회사의 사양이나 측정을 통하여 비교적 쉽게 얻을 수 있다. 복합재료, 다양한 경계조건, 복잡한 대형구조물등은 수치해석을 이 용하여 해석적인 방법으로 동특성을 구할 경우, 신뢰성 있는 정보를 얻기에 는 많은 노력이 요구된다. 더우기 현장에서 발생하는 진동문제는 대부분 복 잡하고 시간적으로 시급히 해결해야 하기 때문에 효율적인 절차를 구성하여 구조물의 동특성을 해석하는 방법을 사용할 필요가 있다. 구조물의 동특성은 실험적인 방법을 통하여 구하고 그 외의 필요한 계산들은 해석을 통하여 얻 는 것이 효율적일 수 있다. 실험적 동특성해석은 입력하중에 대한 응답의 크 기와 위상 비를 주파수별로 나타내는 전달함수를 측정하는 방법으로서 가진 장치 및 여러 측정/분석 장비가 필요하며, 철교, 교량, 건물의 철골 및 콘크 리트 슬라브등 다양한 중대형의 구조물을 Signal/Noise비가 좋도록 가진 시 켜야 할 필요성이 있다. 본 연구에서는 이러한 실험적 방법의 현장 적응성과 신뢰성을 확보하기 위해 대형충격기(large impact hammer, max, peak force 약 10000N, time duration 약 20ms)를 제작하고 실험/분석 시스템 및 구조물 의 진동제어를 위한 절차를 Fig.1과 같이 구성하고 이를 철근콘크리트 건물 에 설치한 기계식 주차설비의 진동제어에 적용하였다.force response simulation)를 수행하여 임의의 좌표 공간에 대한 진동수준을 해석적으로 예측할 뿐만 아니라 구조물의 진동제어 를 위한 동적인자를 변경시킬 수 있는 정보를 제공하며 장비를 방진할 경우 신뢰성 있는 전달률을 결정할 수 있다. 실험적으로 철교, 교량이나 건물의 철골구조 및 2층 바닥 등 대,중형의 복잡한 구조물에 대항 동특성을 나타내 는 모빌리티를 결정할 경우 충격 가진 실험이 사용되는 실험장비 측면에서 나 실험을 수행하는 과정이 대체적으로 간편하다. 그러나 이 경우 대상 구조 물을 충분히 가진시킬수 있는 용량의 대형 충격기(large impact hammer)가 필요하게 된다. 이러한 동적실험은 약 길이 61m, 폭 16m의 4경간 교량에 대 하여 동적실험을 수행하여 가능성을 확인하였다. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the maximum relaxivity value. The results shows

  • PDF

Generation of antibodies against N-terminus fragment of AgI/II protein from Streptococcus mutans GS-5 (연쇄상구균(Streptococcus mutans GS-5)의 항원단백질 AgI/II의 N-terminus절편에 대한 항체형성)

  • Han, Ji-Hye;Baik, Byeong-Ju;Yang, Yeon-Mi;Park, Jeong-Yeol;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.401-410
    • /
    • 2006
  • Dental caries results from localized demineralization of tooth enamel by acids of bacterial origin produced from the fermentation of dietary sugars. A group of related oral bacteria, collectively known as mutans streptococci, are implicated as the primary etiological agents of human caries. Within this group, Streptococcus mutans has been known as a causative agent for dental caries. As well as acid production yielding the demineralization of tooth enamel, adherence and colonization of S. mutans to the teeth are also important for their virulence Cell-surface fibrillar proteins, which mediate adherence to the salivary pellicle are virulence components of mutans streptococci, and primary candidates for a human caries vaccine. Here we report that the AgI/II gene from S. mutans GS-5 were cloned by PCR amplification of the bacterial chromosomal DNA and the integrity of cloned genes were confirmed by nucleotide sequencing. Sequence analyses showed the sequence alignment of 280 nucleotides between the cloned AgI/II and the reported sequence of S. mutans GS-5 showed the perfect match The cloned genes which signal nucleotide was truncated, were transferred into bacterial expression vector and the recombinant proteins were purified as His-tag fusion proteins In order to generate polyclonal antibodies against the recombinant proteins, AgI/II mr, some $100{\mu}g$ of the proteins was injected into mice three times. It can be used for an effective vaccine production to prevent dental caries caused by pathogenic S. mutans.

  • PDF

Improvement of a 4-Channel Spiral-Loop RF Coil Array for TMJ MR Imaging at 7T (7T 악관절 MRI를 위한 4 채널 스파이럴 RF 코일의 성능개선)

  • Kim, Kyoung-Nam;Kim, Young-Bo;Cho, Zang-Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.103-114
    • /
    • 2012
  • Purpose : In an attempt to further improve the radiofrequency (RF) magnetic ($B_1$) field strength in temporomandibular joint (TMJ) imaging, a 4-channel spiral-loop coil array with RF circuitry was designed and compared with a 4-channel single-loop coil array in terms of $B_1$ field, RF transmit (${B_1}^+$), signal-to-noise ratio (SNR), and applicability to TMJ imaging in 7T MRI. Materials and Methods: The single- and 4-channel spiral-loop coil arrays were constructed based on the electromagnetic (EM) simulation for the investigation of $B_1$ field. To evaluate the computer simulation results, the $B_1$ field and ${B_1}^+$ maps were measured in 7T. Results: In the EM simulation result and MRI study at 7T, the 4-channel spiral-loop coil array found a superior $B_1$ performance and a higher ${B_1}^+$ profile inside the human head as well as a slightly better SNR than the 4-channel single-loop coil array. Conclusion: Although $B_1$ fields are produced under the influence of the dielectric properties of the subject rather than the coil configuration alone at 7T, each RF coil exhibited not only special but also specific characteristics that could make it suited for specific application such as TMJ imaging.

Dual Component Analysis for In Vivo T2* Decay of Hyperpolarized 13C Metabolites

  • Joe, Eunhae;Lee, Joonsung;Lee, Hansol;Yang, Seungwook;Choi, Young-Suk;Wang, Eunkyung;Song, Ho-Taek;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Purpose: To investigate the exchange and redistribution of hyperpolarized $^{13}C$ metabolites between different pools by temporally analyzing the relative fraction of dual $T_2{^*}$ components of hyperpolarized $^{13}C$ metabolites. Materials and Methods: A dual exponential decay analysis of $T_2{^*}$ is performed for [1-$^{13}C$] pyruvate and [1-$^{13}C$] lactate using nonspatially resolved dynamic $^{13}C$ MR spectroscopy from mice brains with tumors (n = 3) and without (n = 4) tumors. The values of shorter and longer $T_2{^*}$ components are explored when fitted from averaged spectrum and temporal variations of their fractions. Results: The $T_2{^*}$ values were not significantly different between the tumor and control groups, but the fraction of longer $T_2{^*}$ [1-$^{13}C$] lactate components was more than 10% in the tumor group over that of the controls (P < 0.1). The fraction of shorter $T_2{^*}$ components of [1-$^{13}C$] pyruvate showed an increasing tendency while that of the [1-$^{13}C$] lactate was decreasing over time. The slopes of the changing fraction were steeper for the tumor group than the controls, especially for lactate (P < 0.01). In both pyruvate and lactate, the fraction of the shorter $T_2{^*}$ component was always greater than the longer $T_2{^*}$ component over time. Conclusion: The exchange and redistribution of pyruvate and lactate between different pools was investigated by dual component analysis of the free induction decay signal from hyperpolarized $^{13}C$ experiments. Tumor and control groups showed differences in their fractions rather than the values of longer and shorter $T_2{^*}$ components. Fraction changing dynamics may provide an aspect for extravasation and membrane transport of pyruvate and lactate, and will be useful to determine the appropriate time window for acquisition of hyperpolarized $^{13}C$ images.

Metabolic Changes in Patients with Parkinson's Disease after Stereotactic Neurosurgery by Follow-up 1H MR Spectroscopy

  • Choe, Bo-Young;Baik, Hyun-Man;Chun, Shin-Soo;Son, Byung-Chul;Kim, Moon-Chan;Kim, Bum-Soo;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.5 no.2
    • /
    • pp.99-109
    • /
    • 2001
  • Authors investigated neuronal changes of local cellular metabolism in the cerebral lesions of Parkinsonian symptomatic side between before and after stereotactic neurosurgery by follow-up 1H magnetic resonance spectroscopy (MRS). Patients with Parkinson's disease (PD) (n = 15) and age-matched normal controls (n = 15) underwen MRS examinations using a stimulated echo acquisition mode (STEAM) pulse sequence that provided 2${\times}$2${\times}$2 ㎤ (8ml) volume of interest in the regions of substantia nigra, thalamus, and lentiform nucleus. Spectral parameters were 20 ms TE, 2000 ms TR, 128 averages,2500 Hz spectral width, and 2048 data points. Raw data were processed by the SAGE data analysis package (GE Medical Systems). Peak areas of N-acetylaspartate (NAA), creatine (Cr), choline-containing compounds (Cho), inositols (Ins), and the sum (Glx) of glutamate and GABA were calculated by means of fitting the spectrum to a summation of Lorentzian curves using Marquardt algorithm. After blindly processed, we evaluated neuronal alterations of observable metabolite ratios between before and after stereotactic neurosurgery using Pearson product-moment analysis (SPSS, Ver. 6.0). A significant reduction of NAA/Cho ratio was observed in the cerebral lesion in substantia nigra of PD patient related to the symptomatic side after neurosurgery (P : 0.03). In thalamus, NAA/Cho ratio was also significantly decreased in the cerebral lesion including the electrode-surgical region (P : 0.03). A significant reduction of NAA/Cho ratio in lentiform nucleus was not oberved, but tended toward significant reduction after neurosurgery (P = 0.08). In particular, remarkable lactate signal was noted from the surgical thalamic lesions of 6 among 8 patients and internal segments of globus pallidus of 6 among 7 patients, respectively. Significant metabolic alterations of NAA/Cho ratio might reflect functional changes of neuropathological processes in the lesion of substantia nigra, thalamus, and lentiform nucleus, and could be a valuable finding fur evaluation of Parkinson's disease after neurosurgery. Increase of lactate signals, being remarkable in surgical lesions, could be consistent with a common consequence of neurosurgical necrosis. Thus, IH MRS could be a useful modality to evaluate the diagnostic and prognostic implications fur Parkinsons disease after functional neurosurgery.

  • PDF

Usefulness estimating of Time of flight(TOF) during Carotid angio inspection including Aortic arch (Aortic arch를 포함한 Carotid angio 검사 시 Time of flight(TOF)의 유용성 평가)

  • Yoo, Yeong-Jun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose : The Carotid Angio inspection including Aortic arch applied to wide area is conducted as the Contrast Enhance MR Angiography(CEA) which is using a contrast medium. However it is a burden not only for someone such as infants, pregnant women and patients suffering from kidney failure but continuous use of contrast medium also can be a burden for patients who has been taken follow up inspection since diagnose lesion already. The purpose of this study is to estimate a usefulness of the Time of Flight (TOF) by comparing with CEA. Materials and methods : 10 patients with an average age of 58 (from 45 to 75) who had MRA inspection in our hospital were studied using 3.0 Tesla Aachieva (Philips, Netherland) MRI system and Sense Neuro-Vascular 16 Channels Coil. The same patient was inspected both TOF and CEA simultaneously. The TOF inspection included from Aortic arch to Willis Circle by connecting 3 TOF stacks and so did CEA inspection. The quantitative analysis was conducted through signal to noise ratio(SNR) and contrast to noise ratio(CNR) with soft tissue by setting up an area of interest on CCA bifurcatoin, ICA, ECA, MCA and VA concerning obtained image. In case of qualitative analysis, 3 radiological technologists and 1 radiologist evaluated 4 items (1: Visibility of the blood vessel, 2: Image distortion measure, 3: Overlapping measure with vein, 4: Peripheral blood vessel description measure) into five points scale (1: Very bad, 2: Bad, 3: Normal 4: Good, 5: Very good). Results : Results for the quantitative analysis was obtained by calculating the average of 5 ROIs in case of SNR and CNR separately. Results of SNR, TOF were generally measured higher than CEA (In case of TOF were 166.1, 205.2, 154.39, 172.23, 161.95, and CEA were 92.05, 95.43, 84.76, 73.69, 88.3). But according to the result of CNR, both TOF and CEA were measured similarly as 67.62, 106.71, 55.9, 73.74, 63.46 for TOF and 67.82, 71.19, 60.52, 49.45, 64.07 for CEA. Throughout every results of each ROI, SNR showed statistically meaningful consequence (0.050.05). In case of qualitative analysis the average of each evaluated item was 4.2points and 4.28points in the item1, 2.93points and 4.55points in the item2, 4.6points and 3.13points in the item3, 2.88points and 4.6points in the item4. According to the results TOF was measured higher in the item3 while in the item2 and item4 CEA was higher and in case of the item1, both CEA and TOF were similar. To sum up statistically meaningful results (p<0.05) were shown in the item2, item3 and item4 but not in the item1 (p>0.05). Conclusions : Both TOF and CEA are complementary because each inspection has pros and cons, but when inspect wide area including Aortic arch normally CEA is conducted. But TOF inspection also can be considered as alternative in terms of patients who has difficulty in the contrast medium such as infants, pregnant women and patients suffering from kidney failure and patients during follow up.

  • PDF

Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI (MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석)

  • Lee H. R.;Han J. Y.;Cho M. H.;Im C. H.;Jung H. K.;Lee S. Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.108-115
    • /
    • 2003
  • Purpose : To evaluate the effect of the gradient switching noise on the ECD source localization with the EEG data recorded during the MRI scan. Materials and Methods : We have fabricated a spherical EEG phantom that emulates a human head on which multiple electrodes are attached. Inside the phantom, electric current dipole(ECD) sources are located to evaluate the source localization error. The EEG phantom was placed in the center of the whole-body 3.0 Tesla MRI magnet, and a sinusoidal current was fed to the ECD sources. With an MRI-compatible EEG measurement system, we recorded the multi channel electric potential signals during gradient echo single-shot EPI scans. To evaluate the effect of the gradient switching noise on the ECD source localization, we controlled the gradient noise level by changing the FOV of the EPI scan. With the measured potential signals, we have performed the ECD source localization. Results : The source localization error depends on the gradient switching noise level and the ECD source position. The gradient switching noise has much bigger negative effects on the source localization than the Gaussian noise. We have found that the ECD source localization works reasonably when the gradient switching noise power is smaller than $10\%$ of the EEG signal power. Conclusion : We think that the results of the present study can be used as a guideline to determine the degree of gradient switching noise suppression in EEG when the EEG data are to be used to enhance the performance of fMRI.