• Title/Summary/Keyword: MR fluids

Search Result 67, Processing Time 0.04 seconds

The Comparison of Properties of ER and MR Fluids Using a Rotational Viscometer (회전식 점도측정기를 이용한 ER 및 MR유체의 특성 비교)

  • 이영록;전도영
    • The Korean Journal of Rheology
    • /
    • v.11 no.2
    • /
    • pp.73-81
    • /
    • 1999
  • The intention of this research is to give criteria of designing devices using ER fluids and MR fluids. The Properties of commercial ER fluids and MR fluids are compared using a rotational viscometer. The yield strength is compared upon changes of shear rate, temperature and applied fields. MR fluids seem less sensitive to temperature change than ER fluids. In cases of MR and ER fluid dampers, the time delay and damping force are measured in tension and compression mode when the applied field changes.

  • PDF

The effect of friction on magnetorheological fluids

  • Li, W.H.;Zhang, X.Z.
    • Korea-Australia Rheology Journal
    • /
    • v.20 no.2
    • /
    • pp.45-50
    • /
    • 2008
  • This paper presents an experimental approach to study the effect of friction on magnerorheological (MR) fluids. Both steady and dynamic modes were employed to investigate MR fluid behaviors. The experimental results indicate that the total MR effects are dominated by two factors: magnetic force and friction force. Conventionally, the magnetic force contribution to MR effect has been intensively studied while the friction force effect has attracted less attention. This study provides a method to quantitatively predict the friction contribution to the total MR effect. It may be used to effectively analyze enhanced MR effects reported by other groups. Also, it might provide good guidance to develop high-efficiency MR fluids.

Material Characterization of MR Fluids at High Frequencies (고주파 영역에서의 MR 유체 특성연구)

  • Park, Kyoung-Mi;Kim, Jae-Hwan;Choi, Seung-Bok;Kim, Kyung-Su
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.210-215
    • /
    • 2002
  • MR(Magnetorheogical) fluid composed of fine iron powders dispersed in silicon oil is utilized to many smart structures and devices because of its significant rheological property change by the application of an external magnetic field. When we deal with the shock wave attenuation of warship structures, we should be able to characterize the high frequency behavior of MR fluids. So far, however, many efforts have been focused on the material characterization of MR fluids at low frequencies below 100Hz. In this paper, the MR fluid property characterization at high frequency region is performed. An experimental setup based on wave transmission technique is made and the storage modulus as well as the loss modulus of MR fluids are found from the measured data of speed sound and attenuation. Details of the experiment are addressed and the obtained storage and loss moduli are addressed at $50kHz{\sim}100kHz$.

  • PDF

Material Charcterization of MR Fluids at High Frequencies (고주파 영역에서의 MR유체 특성연구)

  • Park, Kyoung-mi;Kim, Jae-hwan;Park, Seung-Bok;Kim, Kyung-Su
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.327.1-327
    • /
    • 2002
  • MR(Magnetorheogical) fluid composed of fine iron powders dispersed in silicon oil is utilized to many smart structures and devices because of its significant rheological property change by the application of an external magnetic field. When we deal with the shock wave attenuation of warship structures, we should be able to characterize the high frequency behavior of MR fluids. So far, however, much efforts have been focused on the material characterization of MR fluids at low frequencies below 100㎐. (omitted)

  • PDF

Characteristics of MR Fluids with Different Working Modes (작동모드에 따른 MR유체의 특성 비교)

  • 이호근;김기선
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.107-113
    • /
    • 2001
  • This work presents field-dependent Bingham and response characteristics of MR fluids under shear and flow modes. Two different types of magneto-viscometers are designed and manufactured for the shear and flow modes. respectively. For the MR fluid to be tested, MRF-132LD of Lord co. is employed. The field-dependent yield stress is experimentally distilled at various temperatures using the magneto-viscometers. Time responses of the MR fluids to step electric fields are also evaluated under two operating modes.

  • PDF

Design of Compact Magneto-Rheological Fluid Damper for Artificial Low-Limb Prosthesis (Magneto-Rheological Fluid를 이용한 인공지능 의족의 Compact damper 개발)

  • Sung, So-Young;Kang, S.J.;Moon, I.H.;Moon, M.S.;Jang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2962-2964
    • /
    • 2005
  • Magneto-Rheological (MR) fluid is suspension of fine magnetic particles in a liquid carrier such as silicon oil or water. MR fluid exhibits solid-like mechanical behavior into chain or clusters with high yield stress when magnetic field is applied to the particles. The response of MR fluids is very quick and reversible after removal of the field. MR Fluids have high yield stress (up to 5kPs) and operate in low voltage power supply. Recently, MR damper using MR fluids was open used in vibration control system such as structural devices, seat vibration controllers and helicopter rotor systems, but it is too big in size and heavy. Therefore, it is not appreciate to rehabilitation devices such as prosthetic limbs.

  • PDF

Performance Analysis of Smart Impact Damper (지능형 완충기의 특성 해석)

  • ;;Y.T. Choi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.323-327
    • /
    • 2001
  • Electrorheological(ER) and magnetorheological(MR) fluids have a unique ability to increase the dynamic yield stress of the fluid substantially when electric or magnetic field is applied. Controllable fluids such as ER and MR fluids have received considerable attention as several components of engineering devices. One of them is a smart impact damper using ER/MR fluids. Impact damper system can be used in the joint mechanism of railroad vehicle, protection equipment of elevator's drop, and launch equipment of aircraft. This paper presents the results of an analytical study of the performance of a smart impact damper to suppress vibration during impact excitation. The damping capabilities of MR impact damper for variable applied current are analyzed using Bingham model under sudden impact load.

  • PDF

A Study on the Fabrication of Magnetorheometer (마그네토리오메타 제작에 관한 연구)

  • 김영민;신영재;이응숙;김동우;이동주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.496-500
    • /
    • 2004
  • A new, commercially available polishing process called magnetorheological finishing is used to polish and figure precision optics. To understand and model this process correctly it is important to determine the mechanical properties of the fluid under the influence of the magnetic field. Magnetorheological (MR) fluids are commonly modeled as Bingham fluids, so one of the essential properties to measure is the yield stress. Since MR fluids are inherently anisotropic, the yield stress will depend on the mutual orientation of the magnetic field and the direction of deformation. The relative orientation of the field and deformation in polishing does not coincide with common rheological setups, so a new rheometer has been designed and tested. This new magnetorheometer design has been shown to give correct stresses during calibration experiments using Newtonian fluids with a known viscosity. The measured stress has also been shown to have a magnitude consistent with published finite element approximations for magnetic fluids. The design of the instrument was complicated because of the requirements imposed upon the magnetic field, and the difficulty in satisfying the no slip boundary condition. Our results show the importance of having a homogeneous field in the test region during measurements. The solutions to these problems and discussion of the measurements on nonmagnetic and magnetic fluids are given.

  • PDF

Development of a Round endmill Type MR Polishing System Using Neodymium Magnets (네오디뮴 자석을 이용한 라운드 엔드밀 타입 MR연마 시스템 개발)

  • Hong, Kwang-Pyo;Shin, Bong-Cheol;Kim, Dong-Woo;Cho, Myeong-Woo;Je, Tae-Jin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.3
    • /
    • pp.316-321
    • /
    • 2011
  • Recently, it has been studied machining of micro parts with increasing demands for ultra precision parts. However, many engineering problems have already begun in polishing of optical parts or lens. As a method to overcome such problems, a new technology for the polishing of the target surface is being studied by controlling abrasives using MR fluids which are sensitive to magnetic fields. Since the current MR polishing system uses a big electromagnet, and is difficult to polish micro parts or spherical lens. Therefore, in this study, a round endmill type MR polishing system was developed to polish a three-dimensional structure which has spherical or inclined plane. And then, series of experiments were performed to verify the polishing performance of the developed round endmill type MR polishing system.

Improvement of Transmittance and Surface Integrity of Glass Mold for light-hardening polymer Using MR Polishing (HR polishing에 의한 광경화성수지 성형용 글래스 몰드의 투과율 및 표면품위 향상)

  • Lee, J.W.;Kim, D.W.;Cho, M.W.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.78-83
    • /
    • 2009
  • In general, Light-hardening polymer was used UV nanoimprint technology. A light-hardening polymer was had the problem of poor hardness, durability. In order to overcome the problem of polymer, inter change optical glass. However glass is very manufacture and a lowering of standars transmittance. In order to glass recover was necessary polishing process. The process is magnetorheological fluids polishing. MR polishing has been developed as a new precision finishing technique to obtain a fine surface. Hence, Magnetorheological fluids has been used for micro polishing to get micro parts. This polishing process guarantees high polishing quality by controlling the fluid density electrically. The applied material in experiments is fused silica glass. Fused silica glass is widely used in the optical field because of high degree of purity. For MR polishing experiments, MR fluid was composed with DI-water, carbonyl iron and nano slurry ceria. The wheel speed and electric current were chosen as the variables for analyzing the characteristics of MR polishing process. Outstanding surface roughness of Ra=1.58nm was obtained on the fused silica glass specimen. And originally glass transmittance was recover on the fused silica glass.

  • PDF