• Title/Summary/Keyword: MR Spectroscopy

Search Result 144, Processing Time 0.024 seconds

A Study on the Metabolite Changes in Brain Diseases: 3 Teslar 1H Magnetic Resonance Spectroscopy (뇌질환 대사물질 변화의 고찰; 3 Teslar 수소 자기공명분광법)

  • Eun, Sungjong;Kim, Jeongjae;Yoo, Seungcheol
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.35-42
    • /
    • 2014
  • The purpose of this study is to know the differences of metabolism in abnormal brain disease using a single-voxel proton MR spectroscopy(1H MRS) Together with five normal volunteers and each five patients with brain diseases, pathologically proved, underwent MRI and 1H MRS. The quantitative results of 1H MRS in adrenoleukodystrophy(ALD), hepatic encephalopathy(HE), and infarction gave unique information on the metabolite changes related with the white matter: the concentration of NAA decreased in all diseases; Cho, mI and Lac increased in ALD; Cho decreased in HE; and ${\beta}{\cdot}{\gamma}$-Glx and Lac increased in infarction. It is concluded that 1H MRS is capable of diagnosing brain diseases by monitoring metabolite changes in vivo that subsequently develope into abnormalities. 1H MRS may be a useful clinical tool for in both diagnosis and prognosis of brain diseases.

The Development of Signal Processing Software for Single-and Multi-Voxel MR Spectroscopy (단위용적 및 다용적 기법 자기공명분광 신호처리 분석 소프트웨어의 개발)

  • Paik, Moon-Young;Lee, Hyun-Yong;Shin, Oun-Jae;Eun, Choong-Ki;Mu, Chi-Woong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.5
    • /
    • pp.544-555
    • /
    • 2002
  • The aim of this study is to develop the $^1H$-MRS data postprocessing software for both single-voxel and multi-voxel technique, which plays and important role as a diagnostic tool in clinical field. This software is based on graphical user interface(GUI) under windows operating system of personal computer(PC). In case of single-voxel MRS, both of raw data in time-domain and spectrum data in frequency-domain are simultaneously displayed in a screen. Several functions such as DC correction, zero filling, line broadening, Lorentz-Gauss filtering and phase correction, etc. are included to increase the quality of spectrum data. In case of multi-voxel analysis, spectroscopic image reconstructed by 3-D FFT was displayed as a spectral grid and overlapped over previously obtained T1- or T2-weighted image for the spectra to be spatially registered with the image. The analysis of MRS peaks were performed by obtaining the ratio of peak area. In single-voxel method, statistically processed peak-area ratios of MRS data obtained from normal human brain are presented. Using multi-voxel method, MR spectroscopic image and metabolite image acquired from brain tumor are demonstrated.

Investigation of Varied MR Spectra by TE and Metabolite Amount in the Localized Voxel using the MR Cone-shape Phantom (자기공명분광법에서 TE와 Voxel 내의 대사물질 양에 따른 스펙트럼 변화 평가에 관한 연구)

  • Woo, Dong-Cheol;Kim, Sang-Soo;Rhim, Hyang-Shuk;Jahng, Geon-Ho;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.179-185
    • /
    • 2007
  • The purpose of this study is to investigate the spectra of a magnetic resonance spectroscopy (MRS) in accordance with the variance of TE and the volumes of metabolites in a localized voxel for the quality assurance using a designed single voxel spectroscopy QA phantom. Because a cone-shade phantom is designed as the volume of metabolite in a localized voxel is changeable, we try to analyze the peaks of each metabolite (NAA, Cr, Cho, Lac, etc.) in accordance with metabolite volume in a localized voxel as well as echo time (TE). All data were obtained using a 3T MRI/MRS machine and analyzed using $jMRUI^{(R)}$. The results of this study show that TE is in inverse proportion to the noise of MRS and the longer TE and the less metabolite volume in the localized voxel, the peak intensities of each metabolite decrease. In case of the lactate, its peak was observed on the all TE only if the greatest metabolite is included in the localized voxel. Then, the intensity of a metabolite is more sensitive to the metabolite volume in the localized voxel than the TE. These obtained in vitro MRS data is provide the guideline that is important for in vivo metabolite quantification. But, in the edge of cone-shape vial air bubbles were observed and spectrum could not obtained. Therefore our cone-shape MRS phantom needs to be modified in order to solve these problems.

  • PDF

3 Tesla MR Clinical Application: Advanced Neuroimaging

  • 손철호
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.50-56
    • /
    • 2002
  • 최근 3-4년간 MR의 hardware와 software의 급격한 발전으로 마침내 작년 말에 3.0 Tesla whole body MR 장비가 미국 FDA의 공인을 받았다. 한국에서도 일찍부터 3T MR장비의 개발이 이루어 졌고 이미 설치되어 연구와 임상이 이용되고 있다. 여러 회사에서 개발 및 연구된 전신 3.0T MR 장비가 여러가지 가능성을 보이고 임상 도입 단계에 있지만 아직까지 실지 임상에서는 뇌신경계 분야가 주류를 이루고 있다. 지금 뇌신경계 분야에서 보편적으로 늘리 사용되고 있는 1.5T MR 장비는 모든 면에서 상당히 안정적으로 임상 및 연구에 이용되고 있다. 1-2년 전만 해도 3.0 T MR기기는 뇌신경계 영역에서도 임상적으로 늘리 사용되기에는 안정적인 면에서는 1.5T 기기에 비해서 떨어지는 것이 사실이었다. 그래서 주로 연구실 영역에서 많이 이용되고 있었다. 그러나 지금 본원에 설치 완료되어 임상에 적용한지 6개월 정도 이용한 예에서 보면 (about 2300 cases/6months) hardware, software적인 면에서 아직 조금의 불편함이 있지만 많은 부분이 충분히 인지되고 개선이 가능한 부분으로 거의 불편함이 사라질 것으로 기대되고 있고, 불편함을 넘을 수 있는 여러 가지 장점이 있다고 본다. 고자장 (>3.0 T) MRI의 매력은 자장에 비례적으로 SNR, spectral resolution이 높아지고, T1, BOLD등에 의한 대조도가 향상한다는 것이다. SNR의 증가는 temporal, spatial 분해능을 증가시키고, spectral resolution이 높아짐에 따라 MR spectroscopy상에서 주요 대사물질 이외 작은 대사물질에 관한 스펙트럼의 분석을 향상시킨다. 이처럼 고자장 MR은 근본적인 장점을 가지고 있고 이러한 장점이 고자장 MR 시대로 가야 할 이유을 모두 설명하고 있다고 생각된다.세포질등이 있으며, 이들중에서 lysosomes, peroxisomes, 그리고 미토콘드리아가 특정한 유전성 백질질환에 중요한 역할을 하는 것이 밝혀졌다. 이러한 질환들은 최소한 각 소기관에 의한 질환군으로 분류될 수 있다.SXR이 ER의 transactivation 효과를 약간 촉진한 반면 MDA-MB-231세포는 SXR을 제외한 CAR와 PPAR${\gamma}$에 의해 ER의 transactivation 효과가 약간 증가되는 경향을 보였다. 이러한 결과는 유방암세포에서는 CAR, SXR, PPAR${\gamma}$과 같은 xenobiotic nuclear receptor에 의한 ER transactivation 효과가 간암세포와는 다르게 나타나며, 유방암의 종류에 따라서 endogenous CAR, SXR, PPAR${\gamma}$수용체가 다르게 발현됨으로써 이들에 대한 반응이 서로 상이한 특징을 나타낼 수 있을 것으로 사료된다. 따라서 estrogen receptor에 의해 매개되는 estrogn의 전사활성조절기전이 표적세포에 따라 다른 경로를 포함 할 수 있음을 시사한다.서 흡착 능력이 우수하게 나타났으며, 황화수소는 펄라이트, 왕겨, 소나무수피에서 상대적으로 우수한 것으로 나타났으며, 혼합충전재는 암모니아의 경우 코코넛과 펄라이트의 비율이 7:3인 혼합 재료 3번과 소나무수피와 펄라이트의 비율이 7:3인 혼합 재료 6번에서 다른 혼합 재료에 비하여 우수한 것으로 나타났다. 4. 코코넛과 소나무수피의 경우 암모니아 가스에 대한 흡착 능력은 거의 비슷한 것으로 사료되며, 코코넛의 경우 전량을 수입에 의존하고 있다는 점에서 국내 조달이 용이하며, 구입 비용도 적게 소요되는 소나무수피를 사용하는 것이 경제적이라고 사료된다. 5. 마지막으로 악취제거 미생물균주를 접종한 소나무수피 50%와 펄라이트

  • PDF

The Study of Corrosion Induced Co migration and Its Effect on Thermal Asperity Phenomenon (부식작용으로 인하여 디스크면으로 이동된 코발트가 Thermal Asperity 현상에 미치는 영향)

  • 좌성훈
    • Tribology and Lubricants
    • /
    • v.15 no.4
    • /
    • pp.335-342
    • /
    • 1999
  • Corrosion of the disk has been an ongoing concern for the manufacturers of hard disk drives. With the advent of magnetoresistive (MR) head, very low levels of corrosion and contamination become more critical since the raised defects and corrosion products on the disk surface-anything that heats the MR sensor due to the contact-can distort the output signal of the head. This phenomenon is called as thermal asperity. In this paper, the effect of corrosion as a form of Co migration on the occurrence of thermal asperity in MR drives was investigated. The corrosion test at high temperature (60$^{\circ}C$) and high relative humidity (80%) was emphasized in this study and the testing results at ambient condition were compared. The corrosion on the disks was characterized as the amount of Co ion migration using an ion chromatography (IC) and a time-of-flight secondary ion mass spectroscopy (TOF-SIMS). It is proved that corrosion on the disk surface after storage testing is closely correlated to the amount of Co ions migration from the magnetic layer to disk surfaces and higher Co migration causes more thermal asperities in the drive. In order to reduce Co migration, several methods such as burnishing process and structure of the carbon overcoat were investigated. It is found that the hydrogenated carbon overcoat shows the least Co migration among different types of overcoat layer. However, the most effective way to reduce Co migration is the application of Cr layer between the overcoat and the magnetic alloy layer.

Brain Abscesses Associated with Asymptomatic Pulmonary Arteriovenous Fistulas

  • Nam, Taek-Kyun;Park, Yong-sook;Kwon, Jeong-taik
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.1
    • /
    • pp.118-124
    • /
    • 2017
  • Brain abscess commonly occurs secondary to an adjacent infection (mostly in the middle ear or paranasal sinuses) or due to hematogenous spread from a distant infection or trauma. Pulmonary arteriovenous fistulas (AVFs) are abnormal direct communications between the pulmonary artery and vein. We present two cases of brain abscess associated with asymptomatic pulmonary AVF. A 65-year-old woman was admitted with a headache and cognitive impairment that aggravated 10 days prior. An magnetic resonance (MR) imaging revealed a brain abscess with severe edema in the right frontal lobe. We performed a craniotomy and abscess removal. Bacteriological culture proved negative. Her chest computed tomography (CT) showed multiple AVFs. Therapeutic embolization of multiple pulmonary AVFs was performed and antibiotics were administered for 8 weeks. A 45-year-old woman presented with a 7-day history of progressive left hemiparesis. She had no remarkable past medical history or family history. On admission, blood examination showed a white blood cell count of 6290 cells/uL and a high sensitive C-reactive protein of 2.62 mg/L. CT and MR imaging with MR spectroscopy revealed an enhancing lesion involving the right motor and sensory cortex with marked perilesional edema that suggested a brain abscess. A chest CT revealed a pulmonary AVF in the right upper lung. The pulmonary AVF was obliterated with embolization. There needs to consider pulmonary AVF as an etiology of cerebral abscess when routine investigations fail to detect a source.

Monoclonal antibody-based enzyme-linked immunosorbent assay for quantification of majonoside R2 as an authentication marker for Nngoc Linh and Lai Chau ginsengs

  • Jiranan Chaingam;Le Van Huy;Kanta Noguchi;Poomraphie Nuntawong;Sornkanok Vimolmangkang;Varalee Yodsurang;Gorawit Yusakul;Satoshi Morimoto;Seiichi Sakamoto
    • Journal of Ginseng Research
    • /
    • v.48 no.5
    • /
    • pp.474-480
    • /
    • 2024
  • Background: Recent years have witnessed increasing interest in the high amount of ocotillol-type saponin in Panax vietnamensis, particularly in relation to majonoside R2 (MR2). This unique 3%-5% MR2 content impart Ngoc Linh and Lai Chau ginsengs with unique pharmacological activities. However, in the commercial domain, unauthentic species have infiltrated and significantly hindered access to the authentic, efficacious variety. Thus, suitable analytical techniques for distinguishing authentic Vietnamese ginseng species from others is becoming increasingly crucial. Therefore, MR2 is attracting considerable attention as a target requiring effective management measures. Methods: An enzyme-linked immunosorbent assay (ELISA) was developed by producing monoclonal antibodies against MR2 (mAb 16E11). The method was thoroughly validated, and the potential of the immunoassay was confirmed by high-performance liquid chromatography with ultraviolet spectroscopy. Furthermore, ELISA was applied to the assessment of the MR2 concentrations of various Panax spp., including Korean, American, and Japanese ginsengs. Results and conclusions: An icELISA using mAb 16E11 exhibited linearity between 3.91 and 250 ng/mL of MR2, with detection and quantification limits of 1.53 and 2.50 - 46.6 ng/mL, respectively. Based on this study, the developed icELISA using mAb 16E11 could be a valuable tool for analyzing MR2 level to distinguish authentic Ngoc Linh and Lai Chau ginsengs from unauthentic ones. Furthermore, the analysis of the samples demonstrated that Ngoc Linh and Lai Chau ginsengs exhibit a notably higher MR2 value than all other Panax spp. Thus, MR2 might be their ideal marker compound, and various bioactivities of this species should be explored.

허혈성 심질환의 자기공명 영상 진단

  • 최영희
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.5-20
    • /
    • 2002
  • 허혈성 심질환 환자의 평가도구로서 MRI의 역할이 확대된 데에는 소위 "one-stop shop"이라는 통합적 심장검사법의 개발이 계기가 되었다. 즉 한 번의 MRI 검사로서 심실벽운동을 평가하여 심근의 기능과 예비능을 측정하여 만성 심근경색을 평가할 수 있고, 심근의 관류를 평가할 수 있고, 관동맥의 혈류 예비능과 심근의 viability를 평가하고, 관동맥 조영술을 통해, 수술 후의 우회로 평가 및 관동맥의 협착 여부의 진단이 가능한 프로토콜이 MRI장비마다 각각 개발되어 보급되고 있다. 하드웨어와 소프트웨어의 개발과 지속적인 연구를 통해서 MRI는 허혈성 심질환의 진단적 검사로서 기존의 다른 검사들과 비교하여 높은 시간적, 공간적 해상력으로 정확한 구조와 기능의 평가를 제공할 수 있는 가장 유용한 검사가 될 것으로 사료된다 특히, MR 관동맥조영술, 심근관류검사, 심근 표지법, dobutamine 부하검사, viability 평가, plaque characterization, MR spectroscopy 분야에서 현재 활발히 연구가 진행되고 있으며 향후 임상적용이 확대될 것으로 예상된다.

  • PDF

Basic Principles of MR

  • 김성은
    • Proceedings of the KSMRM Conference
    • /
    • 1999.04a
    • /
    • pp.1-9
    • /
    • 1999
  • 핵자기 공명(NMR:nuclear magnetic resonance)은 19451건 Bloch, Procell등에 의해 처음으로 실험적으로 입증된 후에 생화학 및 약학 분야에서 분자단위의 물질의 성분, 구조, 대사물질의 역학적 운동 및 상태에 관한 정보를 아는데 유용한 기법으로 사용 되어 왔다. 의학분야에서는 Lauterber등에 의해 자기공명영상볍(Magnetic Resonance Imaging:MRI)으로 개발되어 질병의 진단 및 치료에 많은 공헌을 하게되었다. 해부학적영상 뿐 아니라 분석방법으로 병변 부위 및 인체 기관에서의 각종 대사물질의 정량적인 양과 변화를 알 수 있는 자기공명분광기법(magnetic resonance spectroscopy:MRS)도 활발한 임상적용이 이루어지고 있다. 자기공명영상법의 활발한 임상적 응용 및 새로운 technique이해를 위해서는 물리학적 개념(MR Physics)을 이해하는 것이 매우 중요하다.

  • PDF

Proton MR Spectroscopic Changes in Parkinson′s Disease

  • 백현만;최보영;손병철;정성택;이형구;서태석
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.88-88
    • /
    • 2003
  • Purpose: To investigate whether there are significant changes in regional brain metabolism in patients with Parkinson's disease after thalamotomy using proton magnetic resonance spectroscopy (1H MRS). Materials and methods: Fifteen patients with Parkinson's disease of mean age 56.5 years (7 males and 8 females; mean age, 56.5 years) that have treated with levodopa were included. All patients with tremor experienced amelioration of their symptoms on the side contralateral to the thalamotomy. As a single-voxel technique, 1H MR spectra were obtained from the volume of interested regions in thalamus and primary motor cortex. Spectral parameters were: 20 ms TE, 2000 ms TR, 128 averages, 2500 Hz spectral width, and 2048 data points.

  • PDF