• Title/Summary/Keyword: MPU6050 Acceleration Sensor

Search Result 7, Processing Time 0.018 seconds

Development of Gait Correction System for Real-Time Gait

  • Kim, Wonsun;Shin, Woojin;Kim, Hyunji;Yeom, Hojun
    • International journal of advanced smart convergence
    • /
    • v.9 no.4
    • /
    • pp.139-148
    • /
    • 2020
  • Walking is one of the most natural and repetitive actions we do in our daily lives. However, many modern people have problems with shoulders, back and spine due to incorrect walking habits. Therefore, it is becoming important to diagnose and correct wrong walking habits, for example, in-toeing, out-toeing, etc. early, which can be a precursor to various diseases. In this study, we developed the system to diagnose and prevent incorrect gait by grasping and analyzing the angle and muscle activity of the foot according to the typical wrong gait type through MPU 6050 acceleration sensor and the surface EMG sensor. Through a smartphone, numerical and visualization screens based on walking can be used to represent the angle of the feet, real-time EMG values, and even the number of steps. The correction effect was enhanced by improving the cognitive ability through a system that allows individuals to easily diagnose gait through smart devices and improve them according to their own problems.

A Study of Simple Sleep Apnea Predictive Device Using SpO2 and Acceleration Sensor

  • Woo, Seong-In;Lee, Merry;Yeom, Hojun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.71-75
    • /
    • 2019
  • Sleep apnea is a disease that causes various complications, and the polysomnography is expensive and difficult to measure. The purpose of this study is to develop an unrestricted wearable monitoring system so that patients can be examined in a familiar environment. We used a method to detect sleep apnea events and to determine sleep satisfaction by non-constrained method using SpO2 measurement sensor and 3-axis acceleration sensor. Heart rate and SpO2 were measured at the finger using max30100. After acquiring the SpO2 data of the user in real time, the apnea measurement algorithm was used to transmit the number of apnea events of the user to the mobile phone using Bluetooth (HC-06) on the wrist. Using the three-axis acceleration sensor (mpu6050) attached to the upper body, the number of times of tossing and turning during sleep was measured. Based on this data, this algorithm evaluates the patient's tossing and turning during sleep and transmits the data to the mobile phone via Bluetooth. The power source used 9 volts battery to operate Arduino UNO and sensors for portability and stability, and the data received from each sensor can be used to check the various degree between sleep apnea and sleep tossing and turning on the mobile phone. Through thisstudy, we have developed a wearable sleep apnea measurement system that can be easily used at home for the problem of low sleep efficiency of sleep apnea patients.

Implementation of Fall Direction Detector using a Single Gyroscope (자이로센서를 이용한 낙상 방향 탐지 시스템 구현)

  • Moon, Byung-Hyun;Ryu, Jeong Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.2
    • /
    • pp.31-37
    • /
    • 2016
  • Falling situations are extremely critical events for the elderly person who requires timely and adequate emergency service. For the case of emergency, the information of falling and its direction can be used as an important information for the first aid treatment of the injured person. In this paper, a falling detection system which can pinpoint the falling event with the falling direction is implemented. In order to detect the fall situation, a single gyroscope (MPU-6050) is used in the developed system. The fall detection algorithm that can classify 8 different fall directions such as front, back, left, right and in between falls is proposed. The direction of the fall is decided by examining the acceleration values of X and Y directions of the sensor. It is shown that the proposed algorithm successfully detects the falling event and the falling direction with probability of 97% for a selected value of acceleration threshold.

Balance Control of Drone using Adaptive Two-Track Control (적응적 Two-Track 기술을 이용한 드론의 균형 제어)

  • Kim, Jang-Won
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.6
    • /
    • pp.666-671
    • /
    • 2019
  • The flight controller(FC) used in small-sized drone was developed as simple structure does not perform complex operations because it uses different MCU with large-sized drone. Also, the balance control of small-sized drone should be simpler than Kalman filter using complex filter and the method using Complementary filter has relatively more operations. So, the method to realize the balance control on small-sized drone effectively using two-track control operating as proper method for above is suggested in this research. This method is a system maintaining effective balance with simple structure and less operations by operating adaptively for the unbalance of the drone with the acceleration sensor with the advantage which performing accurate correction by data processing for long term change and gyroscope sensor maintaining the balance of the drone by data processing for short term change. It is confirmed that stable operation was performed mostly based on the test result for repeatable test more than 100 times using two-track control and it maintained normal state operation more than 98% excluding the difficulty of maintaining normal operation when meets sudden and rapid wind yet.

A Study on Flight Stabilization of Drones by Gyro Sensor and PID Control (자이로 센서와 PID 제어를 이용한 드론 비행 안정화에 관한 연구)

  • Yoon, Dan-Bee;Lee, Kyu-Yeul;Han, Sang-Gi;Kim, Yong-Hun;Lee, Seung-Dae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.4
    • /
    • pp.591-598
    • /
    • 2017
  • The changes of technology and the size of markets for unmaned aerial vehicle are getting bigger presently. Damage happens because of user's poor operation since accesses to the drones are easy. To minimize the damage, drone's stabilized flight skills are required, and controlling the motor to balanced speed is also needed. Thus, the essay shows that we use Arduino as a main control device for controlling a drone, and used acceleration sensor and gyro sensor for the drone stabilization. Also, we made it able to hover at a certain height by using a sonar sensor. We also controlled a drone by using an Android application, and made the drone hover stably at 0~2 meters.

Smart Safety Helmet Using Arduino (아두이노를 이용한 스마트 안전모)

  • Lee, Dong-Gun;Kim, Won-Boem;Kim, Joong-Soo;Lim, Sang-Keun;Kong, Ki-Sok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.77-83
    • /
    • 2019
  • Major causes of industrial accidents include falls and gas leak. The existing safety helmet and smart device combination products are focused on convenience, so the functions to prevent such accidents are insufficient. We developed a smart helmet focusing on fall accident detection and gas leak detection. We also developed management system to manage workers efficiently. Its core function is to detect dangerous conditions of employees, to communicate with managers and to confirm the situations of workers. The effectiveness of the combustible gas measurement capability was verified through experiments. However, since a significant amount of power consumption is founded due to continuous operation of the board and the sensor, countermeasures such as replacing with a large capacity battery are required.

A study on monitoring for process time and process properties by measuring vibration signals transmitted to the mold during injection molding (사출성형공정에서 금형에 전달되는 진동 신호 측정을 이용한 성형 단계별 공정시간과 공정특성의 모니터링에 대한 연구)

  • Lee, Jun-han;Kim, Jong-Sun
    • Design & Manufacturing
    • /
    • v.14 no.3
    • /
    • pp.8-16
    • /
    • 2020
  • In this study, the vibration signal of the mold was measured and analyzed to monitoring the process time and characteristics during injection molding. A 5 inch light guide plate mold was used to injection molding and the vibration signal was measured by MPU6050 acceleration sensor module attached the surface of fixed mold base. Conditions except for injection speed and packing pressure were set to the same value and the change of the vibration signal of the mold according to injection speed and packing pressure was analyzed. As a result, the vibration signal had a large change at three points: "Injection start", "V/P switchover", and "Packing end". The time difference between "injection start" and "V/P switchover" means the injection time in the injection molding process, and the time difference between "V/P switchover" and "Packing end" means the packing time. When the injection time and packing time obtained from the vibration signal of the mold are compared with the time recorded in the injection molding machine, the error of the injection time was 2.19±0.69% and the error of the packing time was 1.39±0.83%, which was the same level as the actual value. Additionally, the amplitude at the time of "injection start" increased as the injection speed increased. In "V/P switchover", the amplitude tended to be proportional to the pressure difference between the maximum injection pressure and the packing pressure and the amplitude at the "packing end" tended to the pressure difference between the packing pressure and the back pressure. Therefore, based on the result of this study, the injection time and packing time of each cycle can be monitored by measuring the vibration signal of the mold. Also, it was confirmed that the level and trend of process variables such as the injection speed, maximum injection pressure, and packing pressure can be evaluated as the change of the mold vibration during injection molding.