Analysis of Small-Field Dosimetry with Various Detectors

  • Park, So-Yeon;Choi, Byeong Geol;Lee, Dong Myung;Jang, Na Young
    • 한국의학물리학회지:의학물리
    • /
    • 제29권4호
    • /
    • pp.164-172
    • /
    • 2018
  • We evaluated the performance of various detectors for small-field dosimetry with field sizes defined by a high-definition (HD) multileaf collimator (MLC) system. For small-field dosimetry, diodes referred to as "RAZOR detectors," MOSFET detectors, and Gafchromic EBT3 films were used in this study. For field sizes less than $1{\times}1cm^2$, percent depth doses (PDDs) and lateral profiles were measured by diodes, MOSFET detectors, and films, and absolute dosimetry measurements were conducted with MOSFET detectors. For comparison purposes, the same measurements were carried out with a field size of $10{\times}10cm^2$. The dose distributions were calculated by the treatment planning system Eclipse. A comparison of the measurements with calculations yielded the percentage differences. With field sizes less than $1{\times}1cm^2$, it was shown that most of the percentage difference values were within 5% for 6-MV and 15-MV photon beams with the use of diodes. The measured lateral profiles were well matched with those calculated by Eclipse as the field sizes increased. Except for the depths of 0.5 cm and 20 cm, there was agreement in terms of the absolute dosimetry within 10% when MOSFET detectors were used. There was good agreement between the calculations and measurements conducted using diodes and EBT films. Both diode detectors and EBT3 films were found to be appropriate options for relative measurements of PDDs and for lateral profiles.

방사선 치료 중 MOSFET 검출기를 이용한 체표면 선량측정법 (In Vivo Dosimetry with MOSFET Detector during Radiotherapy)

  • 김원택;기용간;권수일;임상욱;허현도;이석;권병현;김동원;조삼주
    • 한국의학물리학회지:의학물리
    • /
    • 제17권1호
    • /
    • pp.17-23
    • /
    • 2006
  • 생체내선량측정법(In vivo dosimetry)은 방사선치료 시 선량학적 오차 및 치료장비의 비정상적인 작동을 검출할 수 있는 환자 치료검증방법이다 본 연구에서는 생체내선량측정법 중 환자 체표면에 선량계를 부착하여 환자 치료와 동시에 치료 검증을 할 수 있는 체표면선량측정법을 연구하였다. 이를 위해 선량 재현성 및 방향성이 우수한 MOSFET 검출기를 이용하였다. 선량 검증의 유용성 평가를 위해 치료계획장비의 치료계획검증기능을 이용하여 선량측정지점의 전달선량을 획득하였으며, 이를 MOSFET 검출기의 측정 결과와 비교 분석하였다. 그 결과 MOSFET 검출기의 교정값 및 재현성은 제작사가 제시한 기준값에 대해 ${\pm}2%$ 이내에서 일치하였고, 각 환자에서의 체표면선량측정값은 치료계획에서 얻은 값과 ${\pm}5%$이내에서 일치함을 알 수 있었다. 기존의 전리함과 다이오드 검출기를 사용한 체표면선량측정법은 단순한 치료기법에만 한정하여 사용할 수 있었다. 그러나 본 연구에서 이용한 MOSFET 검출기는 복잡한 방사선치료기법(3 dimensional radiotherapy, intensity modulated radiotherapy)에서 치료계획상의 전달선량을 환자 체표면에서 직접적으로 측정할 수 있어 임상적용의 유용함을 알 수 있었다.

  • PDF

MOSFET 선량계를 이용한 In-vivo 선량의 확인 (In-vivo Dose verification using MOSFET dosimeter)

  • 강대규;이광만
    • 센서학회지
    • /
    • 제15권2호
    • /
    • pp.102-105
    • /
    • 2006
  • In-vivo dosimetry is an essential tool of quality assurance programs in radiotherapy. The most commonly used techniques to verify dose are thermoluminescence dosimeter (TLD) and diode detectors. Metal oxide semiconductor field-effect transistor (MOSFET) has been recently proposed for using in radiation therapy with many advantages. The reproducibility, linearity, isotropy, dose rate dependence of the MOSFET dosimeter were studied and its availability was verified. Consequently the results can be used to improve therapeutic planning procedure and minimize treatment errors in radiotherapy.

KAEROT/m2용 방사선 수명 측정모듈 개발 (The development of radiation lifetime measuring module for KAEROT/m2)

  • 이남호;김승호;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.793-796
    • /
    • 2003
  • The electronics of a mobile robot ill nuclear facilities is required to satisfied the reliability to sustain survival in its radiation environment. To know how much radiation the robot has been encountered to replace sensitive electronic parts, a dosimeter to measure total accumulated dose is necessary. Among many radiation dosimeters or detectors, semiconductor radiation sensors have advantages in terms of power requirements and their sires over conventional detectors. This paper describes the use of the radiation-induced threshold voltage change of a commercial power pMOSFET as an accumulated radiation dose monitoring mean and that of the photo-current of a commercial PIN Diode as a dose-rate measurement mean. Commercial p-type power MOSFETs and PIN Diodes were tested in a Co-60 gamma irradiation facility to see their capabilities as radiation sensors. We found an inexpensive commercial power pMOSFET that shows good linearity in their threshold voltage shift with radiation dose and a PIN diode that shows good linearity in its photo-current change with dose-rate. According to these findings, a radiation hardened hybrid electronic radiation dosimeter for nuclear robots has been developed for the first time. This small hybrid dosimeter has also an advantage in the point of view of reliability improvement by using a diversity concept.

  • PDF

In Vivo Dosimetry with MOSFET Detector during Radiotherapy

  • Cho, Sam-Ju;Kim, Won-Taek;Ki, Yong-Gan;Kwon, Soo-Il;Lee, Sang-Hoon;Huh, Hyun-Do;Cho, Kwang-Hwan;Kwon, Byung-Hyun;Kim, Dong-Won
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2006년도 제33회 추계학술대회 발표논문집
    • /
    • pp.85-85
    • /
    • 2006
  • PDF

보존적 유방절제 환자의 방사선치료 시 종속조사면 병합방법에 따른 반대편 유방의 표면선량평가 (Evaluation of Contralateral Breast Surface Dose in FIF (Field In Field) Tangential Irradiation Technique for Patients Undergone Breast Conservative Surgery)

  • 박병문;방동완;배용기;이정우;김유현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권4호
    • /
    • pp.401-406
    • /
    • 2008
  • 목적 : 종속조사면 병합 치료방법(FIF : Field In Field)을 이용한 유방절선조사 시 반대편 유방의 표면선량을 평가하고자 한다. 대상 및 방법 : FIF치료방법 이용 시 반대편 유방에 흡수되는 표면선량을 평가하고자 동일한 기하학적 조건과 처방선량을 기반으로 열린조사면(Open), 금속쐐기(MW : Metal Wedge), 동적쐐기(EDW : Enhanced Dynamic Wedge)를 이용한 조사방법과 비교하였다. 3차원 치료계획장치를 이용하여 선량분포 최적화를 수행하였으며 계산 결과의 정확도를 검증하기 위해 인체 팬톰과 모스펫 측정기를 사용하여 측정을 수행하였다. 동측 유방 입사면 가장자리로부터 반대편 유방 쪽으로 2, 4, 6, 8, 10cm 지점을 선정하여 각각 표면(0cm : 가피)과 0.5cm(진피) 깊이에서 선량을 측정하였으며, 0.5cm 깊이 선량측정을 위해서 0.5cm 볼루스를 사용하였다. 선량분포의 계산은 불균질 물질을 보정(modified Batho method)하여 0.25cm 격자 해상도로 수행하였다. 결과 : 치료계획장치에서 각 지점의 평균표면선량은 금속쐐기의 경우 표면 및 0.5cm 깊이에서 $19.6{\sim}36.9%$, $33.2{\sim}138.2%$ 증가했고, 동적쐐기는 $1.0{\sim}7.9%$, $1.6{\sim}37.4%$까지 증가하였다. FIF는 $-18.4{\sim}0.7%$, $-8.1{\sim}4.7%$까지 선량이 변화하였다. MOSFET을 이용하여 측정한 경우는 금속쐐기는 표면 및 0.5cm 깊이의 경우 $11.1{\sim}71%$, $22.9{\sim}161.2%$ 증가했고, 동적쐐기는 $4.1{\sim}15.5%$, $8.2{\sim}37.9%$ 선량이 증가했다. FIF는 표면에서 $-15.7{\sim}-4.9%$로 선량이 오히려 감소했으며, 0.5cm 깊이에서의 선량도 $-10.5{\sim}3.6%$로 나타났다. 치료계획장치의 계산값과 실측값을 비교한 결과, 유사한 경향을 보였으나 치료계획장치의 경우 피부선량이 실제측정값보다 다소 과소평가되고 있음을 알 수 있었다. 결론 : 본 실험을 통해 FIF치료방법의 경우 기존 치료방법(MW, EDW)에 비해 치료표적에 최적화 된 선량 분포를 만들어 내면서도 반대편 유방의 피부에 불필요한 산란선량을 최소화하는 치료방법임을 알 수 있었다.

  • PDF