• Title/Summary/Keyword: MODELS

Search Result 41,187, Processing Time 0.067 seconds

THE POSITIONING ERRORS IN BONDING LINGUAL BRACKETS (설측브라켓 부착시 위치오차에 관한 연구)

  • Choi, Joon-Kyu;Hwang, Hyeon-Shik;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.99-111
    • /
    • 1998
  • The purpose of this study was to evaluate the positioning errors according to the method of bonding lingual brackets. Dental models of twenty orthodontic patients with malocclusion were selected for this study. The positioning errors were measured on each model that brackets were bonded to. Three different bonding methods were used. For the first method the bracket was bonded intimately to the lingual surface of the model. For the second method, the bracket was bonded intimately to the lingual surface after setting up using articulator. The passive bracketing, bonding the bracket ligated first to ideal archwire, was used after setting up as the last method. The results were as follows: 1. The brackets bonded without setting up showed greater angulation errors in the upper 1st premolar and the lower canine than those in other bonding methods. The brackets bonded without passive bracketing showed greater positioning errors in upper central incisor, lower 1st and End premolars. 2. The brackets bonded without setting up showed greater torque error in lower 2nd premolar than those in other bonding methods. The brackets bonded without passive bracketing showed greater torque errors in all upper teeth, lower 1st and 2nd premolars. 3. The brackets bonded without passive bracketing showed greater rotation errors between upper central incisors, lower central incisors, lower lateral and central incisor, lower canine and lateral incisor. 4. The brackets bonded without setting up showed greater in-out errors between upper canine and lateral incisor than those in other bonding methods. The brackets bonded without passive bracketing showed greater in-out errors between upper central incisors, upper central and lateral incisors, upper 1st and 2nd premolars, lower lateral and central incisors, lower canine and lateral incisor. These results suggest that there is a large amount of positioning error in lingual brackets even by an indirect bonding technique, and it may be reduced by passive bracketing.

  • PDF

Stress analysis of Multiloop Edgewise Arch Wire with various degree of tip back bend : a study using the finite element method (Multiloop Edgewise Arch Wire의 tip back 정도에 따른 응력 분포에 관한 유한요소법적 연구)

  • Lee, Young-Il;Cha, Kyung-Suk;Ju, Jin-Won;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.127-142
    • /
    • 2000
  • This study have been carried out to find out the mechnical effect of Multiloop Edgewise Arch Wire(MEAW) making use of the finite element method. The tip back bend of MEAW taken in this analysis is $5^{\circ},\;10{\circ}\;and\;15{\circ}$. In addition, Class II or up & down elastic is applied to find out stress distribution and their values in PDL. A adult male of normal occlusion was selected to create the models of teeth and PDL. And the model of MEAW was also created using commercial finite element code (ANSYS version 5.2). The MEAW is forcibly engaged with a class II or up & down elastic, to determine the initial stress generated in PDL. Comparing the compressive and tensile stress at each reference-planes, following results are obtained. 1. When a MEAW of $5^{\circ},\;10{\circ}\;15{\circ}$ tip back bend was engaged with Class II or up & down elastic, the distribution of compressive, tensile stress in entire PDL is similar in each case. 2. The values of compressive and tensile stress in PDL is higher in $15{\circ}$ tip back bend case than in $10{\circ}\;or\;15{\circ}$ tip back bend case. 3. In the distal PDL of 1st and 2nd molar, compressive stress appears. The compressive area is more wide and its values is higher in PDL of 2nd molar than those in 1st molar. The compressive area and its values become more wide and higher according to the increase of the tip back bend. 4. The values of compressive stress are comparatively smaIIer in PDL of molars than those in premolars. 5. Comparing class II and up & down elastic case, tensile stress values in anterior teeth PDL are smaller md their distribution is more wide in up & down elastic case than class If elastic case. On another hand, there is no difference in distribution and stress values in PDL of posterior teeth between two cases. 6. Comparing the tensile area in PDL of anterior teeth, tensile stress values are maximum in PDL of canine.

  • PDF

Strength and Deformation Capacities of Short Concrete Columns with Circular Section Confined by GFRP (GFRP로 구속된 원형단면 콘크리트 단주의 강도 및 변형 능력)

  • Cho, Soon-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.121-130
    • /
    • 2007
  • To investigate the enhancement in strength and deformation capacities of concrete confined by FRP composites, tests under axial loads were carried out on three groups of thirty six short columns in circular section with diverse GFRP confining reinforcement. The major test variables considered include fiber content or orientation, wrap or tube type by varying the end loading condition, and continuous or discontinuous confinement depending on the presence of vortical spices between its two halves. The circumferential FRP strains at failure for different types of confinements were also investigated with emphasis. Various analytical models capable of predicting the ultimate strength and strain of the confined concrete were examined by comparing to observed results. Tests results showed that FRP wraps or tubes provide the substantial increase in strength and deformation, while partial wraps comprising the vertical discontinuities fail in an explosive manner with less increase in strength, particularly in deformation. A bilinear stress-strain response was observed throughout all tests with some variations of strain hardening. The failure hoop strains measured on the FRP surface were less than those obtained from the tensile coupons in all tests with a high degree of variation. In overall, existing predictive equations overestimated ultimate strengths and strains observed in present tests, with a much larger scatter related to the latter. For more accuracy, two simple design- oriented equations correlated with present tests are proposed. The strength equation was derived using the Mohr-Coulomb failure criterion, whereas the strain equation was based on entirely fitting of test data including the unconfined concrete strength as one of governing factors.

Factors influencing primary stability of miniplate anchorage: a three-dimensional finite element analysis (미니플레이트의 골내 고정원 적용 시 초기 안정성에 영향을 주는 요인에 대한 3차원 유한요소법적 연구)

  • Lee, Nam-Ki;Choi, Dong-Soon;Jang, In-San;Cha, Bong-Kuen
    • The korean journal of orthodontics
    • /
    • v.38 no.5
    • /
    • pp.304-313
    • /
    • 2008
  • Objective: The purpose of this study was to evaluate the stress distribution in bone and displacement distribution of the miniscrew according to the length and number of the miniscrews used for the fixation of miniplate, and the direction of orthodontic force. Methods: Four types of finite element models were designed to show various lengths (6 mm, 4 mm) and number (3, 2) of 2 mm diameter miniscrew used for the fixation of six holes for a curvilinear miniplate. A traction force of 4 N was applied at $0^{\circ}$, $30^{\circ}$, $60^{\circ}$ and $90^{\circ}$ to an imaginary axis connecting the two most distal unfixed holes of the miniplate. Results: The smaller the number of the miniscrew and the shorter the length of the miniscrew, the more the maximum von Mises stress in the bone and maximum displacement of the miniscrew increased. Most von Mises stress in the bone was absorbed in the cortical portion rather than in the cancellous portion. The more the angle of the applied force to the imaginary axis increased, the more the maximum von Mises stress in the bone and maximum displacement of the miniscrew increased. The maximum von Mises stress in the bone and maximum displacement of the miniscrew were measured around the most distal screw-fixed area. Condusions: The results suggest that the miniplate system should be positioned in the rigid cortical bone with 3 miniscrews of 2 mm diameter and 6 mm length, and its imaginary axis placed as parallel as possible to the direction of orthodontic force to obtain good primary stability.

A Novel Method to Study the Effects of Cyclosporine on Gingival Overgrowth in Children (소아에서 치은 과증식에 대한 cyclosporine의 효과를 연구하는 새로운 방법)

  • Han, Keumah;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.3
    • /
    • pp.271-279
    • /
    • 2018
  • Previous studies to elucidate the etiology of cyclosporine(Cs)-induced gingival overgrowth in children have not completely excluded all factors that may cause differences among individuals. This study examined the effect of cyclosporine on the metabolism of type 1 collagen(CoL-I) in experimental models that controlled the effects of biological variations on individuals. Five 5-week-old male Sprague-Dawley rats were administered Cs by gastric feeding for 6 weeks. Gingival specimens were harvested from the mandibular posterior area before beginning Cs administration and at 2, 4, and 6 weeks thereafter. Gingival fibroblasts were cultured from all the 20 biopsies collected from the gingiva. Half of the fibroblasts collected prior to the Cs administration were designated as Control. The other half of the fibroblasts were treated with Cs in vitro and called in vitro test group(Tt). The fibroblasts collected 2, 4, and 6 weeks after the Cs administration were called in vivo test groups : T2, T4, T6, respectively. Immunofluorescence microscopy was used to detect CoL-I in all the fibroblasts. CoL-I was analyzed at both the gene and protein expression levels by real-time polymerase chain reaction and western blotting. Changes in CoL-I before and after Cs treatment were evaluated from the gingiva of each rat. There was no significant difference in gene expression of CoL-I in the control and test groups. CoL-I protein expression levels of fibroblasts increased in in vitro Cs treatment for each individual, and also increased in in vivo Cs treatment. In this study, the experimental method that control biological variations that can occur due to differences among individuals was useful. Subsequent studies on other factors besides CoL-I and in-depth studies in humans are needed.

Soil-to-Plant Transfer of $^{54}Mn,\;^{60}Co,\;^{85}Sr$ and $^{137}Cs$ Deposited during the Growing Season of Potato (감자의 재배기간 중 토양에 침적한 $^{54}Mn,\;^{60}Co,\;^{85}Sr,\;^{137}Cs$의 작물체로의 전이)

  • Choi, Yong-Ho;Lim, Kwang-Muk;Jun, In;Keum, Dong-Kwon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.3
    • /
    • pp.105-112
    • /
    • 2008
  • To measure the soil-to-plant transfer factors ($TF_a,\;m^2\;kg^{-1}$-fresh) of radionuclides deposited during the growing season of potato, a radioactive solution containing $^{54}Mn,\;^{60}Co,\;^{85}Sr$ and $^{137}Cs$ was applied to the soil surfaces in soil boxes 2 d before seeding and three different times during the plant growth. For the pre-seeding application (PSA), radionuclides were mixed with the topsoil (loamy sand and 5.2 in pH). The plant parts investigated were leaves, stems, tuber skin and tuber flesh. The $TF_a$ values of $^{54}Mn,\;^{60}Co,\;^{85}Sr$ and $^{137}Cs$ from the PSA were in the ranges of $1.9{\times}10^{-4}{\sim}1.5{\times}10^{-2}$, $1.8{\times}10^{-4}{\sim}7.5{\times}10^{-4}$, $4.0{\times}10^{-4}{\sim}1.6{\times}10^{-2}$, $1.5{\times}10^{-4}{\sim}3.9{\times}10^{-4}$ respectively, for different plant parts. The TFa values from the growing-time applications were on the whole a few times lower than those from the PSA. For $^{54}Mn,\;^{85}Sr$ and $^{137}Cs$, the $TF_a$ values from the early- or middle-growth-stage application were higher than those from the late-growth-stage application, whereas the opposite was true for $^{60}Co$. Leaves and tuber flesh had the highest and lowest $TF_a$ values, respectively, in most cases. The total uptake from soil by the four plant parts was in the range of $0.05{\sim}3.16%$. In the third year following the PSA, the $TF_a$ values of $^{54}Mn,\;^{60}Co$ and $^{137}Cs$ were $11{\sim}25%$, $21{\sim}25%$ and $38{\sim}67%$ of those in the first year, respectively, depending on the plant parts. The present results can be used for estimating the radiological impact of an acute radioactive deposition during the growing season of potato and for testing the validity of relevant food-chain models.

Information Flow During Individual Model Construction and Group Model Construction Type in the Sound Propagation Model Co-Construction Class (소리의 전달 모형구성 수업에서 나타난 개인모형 구성 단계 중 정보의 흐름과 모둠모형 구성의 유형)

  • Park, Jeongwoo;Yoo, Junehee
    • Journal of The Korean Association For Science Education
    • /
    • v.38 no.3
    • /
    • pp.393-405
    • /
    • 2018
  • In this study, we classified the group model construction types in the actual classroom situation implementing the instructional strategy mixed with individual model construction and group model construction types. The purpose of this study is to analyze the information flow and the individual construction types of each group model construction type to obtain implications for model co-construction in a real classroom environment. A two-session class on sound propagation was carried out for thirty-three 8th grade students in Seoul. A total of 65 individual model construction and 16 group model construction processes were collected and analyzed. The group model construction types were classified as unchanged, enumerated, and elaborated. The unchanged type was found in 8 groups, the enumerated type in 3 groups, and the elaborated type in 5 groups. The isolated individual and independent construction (i.I) were found mostly in the unchanged group construction type (50.0%) and enumerated group construction type (54.5%). In the unchanged type, the radial shape of flow in which one student's information is transmitted to all the members of the group appeared. In the enumerated type, the starting point of the information flow was observed from two individuals. In the elaborated type, linear information flow appeared and both the second dissemination and reflective construction (2d.R) contributed to the group model construction (58.3%). This study suggests a viewpoint that enables to understand the process of complex model construction in an actual classroom context rather than in an ideal situation. The result of this study suggests the necessity of a modeling strategy considering the characteristics of Korean small group culture. It is expected that the discussion will progress through further studies.

Protein Requirements of the Korean Rockfish Sebastes schlegeli (조피볼락 Sebastes schlegeli의 단백질 요구량)

  • LEE Jong Yun;KANG Yong Jin;LEE Sang-Min;KIM In-Bae
    • Journal of Aquaculture
    • /
    • v.6 no.1
    • /
    • pp.13-27
    • /
    • 1993
  • In order to determine the protein requirements of the Korean rockfish Sebastes schlegeli six isocaloric diets containing crude protein level from 20\%\;to\;60\%$ were fed to two groups of fish, small and large size, with the initial average body weight of 8 g and 220 g respectively. White fish meal was used as a sole protein source. Daily weight gain, daily protein retention. daily energy retention, feed efficiency, protein retention efficiency and energy retention efficiency were significantly affected by the dietary protein content (p< 0.05). The growth parameters (that is, daily weight gain, daily protein retention and daily energy retention) increased up to $44\%$ protein level with no additional response above this point. The protein requirements were determined from daily weight gain using two different mathematical models. Second order polynomial regression analysis showed that maximum daily weight gain occurred at $56.7\%\;and\;50.6\%$ protein levels for the small size group and the large size group, respectively. However the protein requirements, determined by the broken line model, appeared to be about $40\%$ for both groups. Nutrient utilization also suggested that the protein requirements of both groups were close to $40\%$. When daily protein intake was considered, daily protein requirements per 100g of fish, estimated by the broken line model, were 0.99g and 0.35g for the small and large size groups respectively. Based on these results, a $40\%$ dietary crude protein level could be recommended for the optimum growth and efficient nutrient utilization of the Korean rockfish weighing between 8g and 300g.

  • PDF

Effect of attachments and palatal coverage of maxillary implant overdenture on stress distribution: a finite element analysis (상악 임플란트 피개의치에서 유지장치 종류와 구개 피개 유무에 따른 응력분포에 대한 유한요소분석)

  • Park, Jong-Hee;Wang, Yuan-Kun;Lee, Jeong-Jin;Park, Yeon-Hee;Seo, Jae-Min;Kim, Kyoung-A
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.70-79
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the effect of attachments and palatal coverage on stress distribution in maxillary implant overdenture using finite element analysis. Materials and Methods: Four maxillary overdenture 3-D models with four implants placed in the anterior region were fabricated with computer-aided design. 1) Ball-F: Non-splinted ball attachment and full palatal coverage, 2) Ball-P: Non-splinted ball attachment and U-shaped partial palatal coverage, 3) Bar-F: Splinted milled bar attachment and full palatal coverage, 4) Bar-P: Splinted milled bar attachment and U-shaped partial palatal coverage. Stress distribution analysis was performed with ANSYS workbench 14. 100 N vertical load was applied at the right first molar unilaterally and maximum stress was calculated at the implant, peri-implant bone and mucosa. Results: The use of the ball attachment showed lower maximum stress on implant and peri-implant bone than the use of the milled bar attachment. But it showed contrary tendency in the mucosa. Regardless of attachment, full palatal coverage showed lower maximum stress on implant, peri-implant bone and mucosa. Conclusion: Within the limitation of this study, ball attachment improved stress distribution on implant and peri-implant bone rather than milled bar attachment in maxillary implant overdenture. Also, full palatal coverage is more favorable in stress distribution.

A study on the Wonju Medical Equipment Industry Cluster (원주의료기기산업 클러스터의 형성과정에 관한 연구)

  • Lee, Woo-Chun;Yoon, Hyung-Ro
    • Journal of the Korean Academic Society of Industrial Cluster
    • /
    • v.1 no.1
    • /
    • pp.67-86
    • /
    • 2007
  • Wonju Medical Equipment Industry, despite of its short history, poor sales and weak manpower and so on, have shown remarkable outcomes in a relatively short period. At the end of 2007, totally 79 enterprises (only 4.6% of whole enterprises in Korea) made 10% of the nationwide production and 15% of the nationwide exports with an annual average growth rate of 66.7%, contributing domestic medical equipment industry tremendously. In addition, many leading medical equipment enterprises in various fields already moved or plan to move to Wonju, accelerating Wonju Medical Equipment Cluster. Wonju Medical Equipment Industry Cluster now enters into the growth stage, getting out of the initial business setup stage. Especially, the nomination of Wonju cluster project from the government accelerates networking (e.g. the development of the universal parts, the establishment of the mutual collaboration model among enterprises, and the mutual marketing), making a rapid growth in Wonju Medical Equipment Industry. Wonju Medical Equipment Industry Cluster revealed positive outcomes despite of the weakness in investment size and infra-structure comparing with the other medical industry cluster in the advanced country, while many domestic enterprises pursued their own growth models and thus failed to promote the international competitive power. Wonju Medical Equipment Industry has been developed rapidly. However, there are many challenging problems to support enterprises: small R&D investment and thus weak technology power, difficulties in recruiting R&D engineers, and poor marketing capabilities, financial infrastructure & policies, and network architecture. In order to develop a world-competitive medical equipment industry cluster at Wonju, the complement of infrastructures, the technology innovation, the mutual marketing, and the network expansion to support enterprises are further required. Wonju' s experiences in developing medical equipment industry so far suggest that our own flexible cluster model considering the industry structure and maturity for different regions should be developed, and specific action plans from the local and central governments based on their systematic strategies for industry development should be implemented in order to build world-competitive industry clusters in Korea.

  • PDF