• Title/Summary/Keyword: MM

Search Result 35,933, Processing Time 0.051 seconds

Evaluation of Bolus Applicability through Dose Evaluation According to 3D Print Materials (3D 프린트 소재에 따른 선량평가를 통한 볼루스 적용성 평가)

  • Kim, Jung-Hoon;Lee, Deuk-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.241-246
    • /
    • 2019
  • Among the 4th Industrial Revolution technologies, evaluated bolus applicability through dose assesment according to the materials of 3D printing technology. Dose assesment was using MCNPX which was applied Monte Carlo method and 3D print materials were ABS, PC and PLA. Thus, the thickness with the same effect as the bolus 10 mm was found to be ABS 10 mm, PC 9 mm and PLA 9 mm for the 6 MeV electron. For 6 MV X-ray, ABS 11 mm, PC 10 mm and PLA 9 mm were shown. This study showed that tissue equivalent materials made from 3D printer materials can replace bolus.

Pork Quality Characteristics by Different Backfat Thickness (등지방 두께에 따른 돈육의 품질 특성)

  • Hah Kyoung-Hee;Jin Sang-Keun;Kim Il-Suk;Song Young-Min;Lee Jae-Ryong;Chung Ku-Young
    • Food Science of Animal Resources
    • /
    • v.25 no.4
    • /
    • pp.391-396
    • /
    • 2005
  • The objective of this study was carried out investigate the changes of carcass characteristics, physico-chemical characteristics and fatty acid composition in crossbred pigs (Korean native breed ${\times}$ Landrace breed) by backfat thickness. A total 182 Pigs were divided into 3 groups by there backfat thickness, i.e., <11.80mm, $11.80\~25.01mm\;and\;25.01mm<.$ The live weight carcass weight and dressing percent of backfat thickness 25.01mm< group were higher compared to those for backfat thickness <11,80mm and $11.80\~25.01mm group, but the final grade were lower. The pH of backfat thickness 25.01mm< group were higher compared to those for backfat thickness <11.80mm and $11.80\~25.01mm$ group. Shear lone of 25.01 mm< group were lower than that of other groups. Water, crude fat content and cooking loss have no difference between the 3 groups. The hardness of backfat thickness 25.01mm< group were higher compared to those for backfat thickness <11.80mm and $11.80\~25.01mm$ group. The yellowness $(b^*)$ of meat and fat color in backfat thickness 25.01mm< group were lower compared to those for backfat thickness <11.80mm and $11.80\~25.01mm$ group. The stearic acid and saturated fatty acid content were higher compared to those for backfat thickness <11.80mm and $11.80\~25.01mm$ group but the linoleic acid and unsaturated fatty acid content were lower.

Performance Evaluation of a Pinhole Collimator According to the Aperture Diameter (핀홀 콜리메이터 초점의 직경 크기 별 성능비교 및 평가)

  • Lee, Kwang Hun;An, Byung Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.104-109
    • /
    • 2014
  • Purpose: Conventional pinhole scintigraphy offers a high resolution and generally use for thyroid scan or bone scintigraphy. the aim of this study is to evaluate performance of each aperture according to the diameter size. Materials and Methods: In this study 2 mm, 4 mm, 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture, we acquired projection image by using SPECT for evaluating FWHM, resolution test and static image for evaluating thyroid phantom test. Results: As a result of FWHM showed 2.2 mm FWHM, 3.2 mm FWHM, 5.4 mm FWHM, 7.5 mm FWHM per each aperture in the resolution test. SNR, uniformity, contrast were acquired result from thyroid phantom test comparing general image and delayed image. as a result of SNR showed 6.55, 8.47, 6.2, 5.23 in case of general image and 5.25, 5.01, 5.38, 5.82 in case of delayed image per each aperture. as a result of uniformity showed 0.152, 0.118, 0.161, 0.19 in case of general image and 0.19, 0.199, 0.185, 0.171 in case of delayed image per each aperture. as a result of contrast showed 1.31, 1.19, 1.15, 1.01 in case of general image and 1.09, 1.08, 1.04, 1 in case of delayed image per each aperture. Conclusion: Resolution and sensitivity were heavily influenced by aperture size. and also we found advantage of delayed image as a result of thyroid phantom test.

  • PDF

Anthropometry of Nose in Korean Twenties (20대 한국인 코의 계측치)

  • Bae, Tae Hui;Yu, Young Il;Kim, Woo Seob;Kim, Han Koo
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.2
    • /
    • pp.61-66
    • /
    • 2009
  • Purpose: The aim of this study is to establish anatomical dimension of the nose and nostril shape in Korean twenties. Methods: Authors measured anthropometry of nose in Korean youths 1,000 individuals (male 363, female 637) and analyzed stastically them. Results: The mean measurements are as follows. 1. The shape of nostrils was classified into 7 types by the angle between both long axis of nostril (male / female). Type I ($<40^{\circ}$)1.7% / 1.72%, Type II ($41-70^{\circ}$) 26.17% / 29.35%, Type III ($71-100^{\circ}$) 39.94% / 38.77%, Type IV (unclassified) 3.85% / 5.80%, Type V ($101-130^{\circ}$) 20.93% / 17.89%, Type VI ($131-180^{\circ}$) 7.43% / 5.96%, Type VII ($>180^{\circ}$) 0% / 0.47% 2. Lengths (male/female) Width of nasal root: $25.29{\pm}2.25mm/24.72{\pm}2.40mm$ Width of nose: $37.63{\pm}2.46mm/34.77{\pm}2.11mm$ Width of columella: $7.18{\pm}0.92mm/6.92{\pm}0.86mm$ Width of alar: $4.99{\pm}1.00mm/4.74{\pm}0.91mm$ Width of nostril floor: $10.98{\pm}1.40mm/10.13{\pm}1.73mm$ Protrusion of nasal tip: $17.12{\pm}1.95mm/16.88{\pm}1.84mm$ Length of alar: $27.10{\pm}2.21mm/24.66{\pm}2.18mm$ Length of nasal root: $17.37{\pm}2.51mm/16.08{\pm}2.90mm$ Depth of nasal root: $7.83{\pm}1.63mm/6.82{\pm}1.36mm$ Length of columella: $8.13{\pm}1.40mm/7.30{\pm}1.46mm$ Height of nose: $60.50{\pm}8.90mm/59.14{\pm}9.22mm$ Height of nasal bridge: $52.68{\pm}7.49mm/50.57{\pm}7.71mm$ 3. Angles Nasofacial angle: $30.19{\pm}3.43^{\circ}/29.13{\pm}6.31^{\circ}$ Nasofrontal angle: $134.88{\pm}7.25^{\circ}/139.94{\pm}6.33^{\circ}$ Nasolabial angle: $95.08{\pm}8.95^{\circ}/95.80{\pm}8.93^{\circ}$ 4. Nasal index: $72.60{\pm}9.57%/68.21{\pm}7.03%$ Nasal tip protrusion-nasal height index: $45.64{\pm}5.21%/47.09{\pm}5.21%$ Nasal tip protrusion-nasal width index: $32.61{\pm}6.83%/31.63{\pm}6.71%$ Conclusion: These data could be useful reference for anthropometry of nose in Korean twenties.

Measurement and Comparison of Morphology of Developmental Stages of Chestnut Weevil, Curculio sikkimensis(Coleoptera: Curculionidae) (밤바구미 (Curculio sikkimensis)의 발육단계별 형태측정 및 비교)

  • Kim, Young-Jae;Moon, Sang-Rae;Yoon, Chang-Mann;Kim, Gil-Hah
    • Korean journal of applied entomology
    • /
    • v.49 no.1
    • /
    • pp.11-16
    • /
    • 2010
  • Measurements were made on morphology of each developmental stages of the chestnut weevil, Curculio sikkimensis, reared in the laboratory and field from 2003 to 2006. The size of egg was 0.8${\pm}$0.03 mm. The escaping larvae were measured, in average, as 98 mg in body weight, 10.65 and 3.99 mm in body length and width, and 1.70 mm in head width. Pupal size of female and male was 7.01 and 6.53 mm, respectively. The fresh weight (0.343 g), body length (7.76 mm) and width (3.38 mm), and head width (1.60 mm) of female adults were significantly bigger than those (0.268 g, 7.14 mm, 3.01 mm and 1.37 mm, respectively) of male adults. Proboscis length (6.53 mm) and antennal length (5.47 mm) of female was also significantly longer than those (3.56 and 4.63 mm, respectively) of male. The larvae of C. sikkimensis overwintered for 1~3 years and their body weight, body length, and body width were decreased. The ratio between proboscis length and body length, the basipodite position attached to the proboscis, and shape of the sex organ on the abdominal end could be used to discriminate sexes.

Relationship between Rainfall Intensity and Slope Stability based on Numerical Analysis (수치해석에 의한 강우강도와 사면 안정성의 상관성 분석)

  • Lee, Min-Seok;Kim, Gyo-Won
    • The Journal of Engineering Geology
    • /
    • v.19 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • This study was conducted to characterize the relationship of rainfall intensity and slope stability by using numerical analysis. The maximum precipitation rate for 10 minutes, 1 hour and 1 day was determined as 28 mm, 70 mm and 271 mm, respectively, by investigating 36 years of KMA data. Then slope infiltration analysis was performed to obtain the ground water level in the slope by using computer programming SEEP/W, and slope stability analysis was done for each time step by using program SLOPE/W. The factor of safety was minimized when the slope was saturated under each rainfall intensity; the time required for saturation was 2 hours with 10 minutes rainfall intensity of 28 mm, 7 hours with 1 hour rainfall intensity of 70 mm and 3 days with 1 day rainfall intensity of 271 mm. When accumulated rainfall was 196 mm for the 10minutes rainfall intensity of 28 mm with duration of 2 hours, the factor of safety was decreased to 1.0, while accumulated rainfall of 468 mm and 820 mm for the 1 hour and 1 day rainfall intensity, respectively, was required to reach the factor of safety, 1.0. Since the normalized rainfall intensity was 13 mm and 1.9 mm for 1 hour and 1 day maximum rainfall, respectively, those results showed that the rainfall intensity could have a more effect on the slope stability than the accumulated rainfall.

INFLUENCE OF TIP DISTANCE ON DEGREE OF CONVERSION OF COMPOSITE RESIN IN CURING WITH VARIOUS LIGHT SOURCES (광원에 따른 조사거리의 증가가 복합레진의 중합도에 미치는 영향)

  • Kim, Sang-Bae;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.273-279
    • /
    • 2004
  • Recently, newly developed single high-intensity LED curing lights for composite resins are claimed to have a higher intensity than previous LED curing lights and to results in optimal properties and short curing time. The purpose of this study was to determine the curing effectiveness of the curing units and to evaluate the relationship between the degree of polymerization and distance from curing light tip end to resin surface. One composite resin was tested(Filtek Z250). Thin film specimens were cured with a LED curing unit(Elipar Freelight 2, 10s), Plasma Arc curing unit(Flipo, 6s), Halogen curing light(XL3000, 20s) at four curing light tip to the resin surface(0mm, 2mm, 4mm, 6mm). Degree of conversion of composite resins were determined by a Fourier Transform Infrared Spectrometer(FTIR). From the present study, the following results were obtained. 1. In all curing units, relative light intensity was significantly decreased according to the increase of distance of light tip to the resin surface(p<0.05). LED curing units showed a higher percentile decrease in intensity than other curing units. 2. In all curing units, degree of conversion was decreased as increase of the distance but no statistically significant difference(p>0.05) except between 4mm and 6mm(p<0.05). 3. When comparing degree of conversion of light curing units at each distance(0mm, 2mm, 4mm, 6mm), LED curing light had a higher degree of conversion than plasma arc and halogen curing lights at 0, 2, 4mm(p<0.05). At 6mm, there was a no significant difference among the curing units(p>0.05).

  • PDF

Cortical Bone Thickness for Mini-implant Placement in Korean

  • Kim, Kyu-Tag;Yu, Sun-Kyoung;Lee, Myoung-Hwa;Lee, Yun-Ho;Kim, Hye-Ryun;Kim, Heung-Joong
    • International Journal of Oral Biology
    • /
    • v.36 no.2
    • /
    • pp.65-70
    • /
    • 2011
  • Recently, mini-implant is popular in the orthodontic treatment due to its simplicity and convenient surgical procedure. The objective of this study is to provide the anatomical guideline for mini-implant placement by analysing the cortical bone thickness in Korean. Hemi-sections of sixteen maxillae and twenty-two mandibles with normal teeth were used. Interdental areas between the 1st premolar and the 2nd premolar (Group 1), the 2nd premolar and the 1st molar (Gruop 2), and the 1st molar and the 2nd molar (Group 3) were sectioned and then scanned. After setting the axis of teeth, the cortical bone thickness was measured at the distance of 2 mm, 4mm, 6 mm, and 8 mm from alveolar crest. The mean thickness of cortical bone in the maxilla according to distance from alveolar crest was $1.30\;{\pm}\;0.63\; mm$ (2 mm), $1.49\;{\pm}\;0.62\; mm$ (4mm), $1.72\;{\pm}\;0.64\; mm$ (6mm), and $1.90\;{\pm}\;0.90\; mm$ (8 mm) at the buccal side and $1.33\;{\pm}\;0.47 \;mm$, $1.31\;{\pm}\;0.45\; mm$, $1.37\;{\pm}\;0.55\; mm$, and $1.39\;{\pm}\;0.58 \;mm$ at the palatal side. In the mandible, that was $3.14\;{\pm}\;1.71 \;mm$, $4.31\;{\pm}\;2.22 \;mm$, $4.23\;{\pm}\;1.94 \;mm$, and $4.30\;{\pm}\;1.57\; mm$ at the buccal side and $1.98\;{\pm}\;0.88 \;mm$, $2.79\;{\pm}\;1.01\; mm$, $3.35\;{\pm}\;1.27$ mm, and $3.93\;{\pm}\;1.38\; mm$ at the lingual side. The buccal cortical bone thickness in the maxilla was decreased from Group 1 to Group 3, while the thickness of palatal side was no change. In the mandible, it did not show a tendency at the buccal side and it was decreased from Group 1 to Group 3 without significant difference at the lingual side. Therefore, the buccal side of the Group 1 and Group 2 in both the maxilla and mandible seems to be the most appropriate site for a mini-implant placement with taking the stability and retention.

Studies on the Antibacterial Activity of Poria cocos (복령의 항균력(抗菌力)에 관한 연구(硏究))

  • Lee, Kook-Sung;Lee, Min-Woong;Lee, Ji-Yul
    • The Korean Journal of Mycology
    • /
    • v.10 no.1
    • /
    • pp.27-31
    • /
    • 1982
  • The antibacterial activity of Poria cocos against the human pathogenic bacteria and general bacteria was observed. The results obtained were as follows; 1. There wasn't any anti­bacterial activity at the Poria cocos powders, pieces and its extracts in every different kinds and places of origin. 2. Hyphae of Poria cocos in every different kinds and places of origin had the antibacterial activity against four Gram positive bacteria, i.e., Staphylococcus aureus, S. epidermidis, Bacillus subtilis and Streptococcus faecalis, on the other hand, hadn't the antibacterial activity against six Gram negative bacteria, Salmonella typhi, Shigella dysenteriae, Pseudomonas aeruginosa, Escherichia coli, Proteus vulgaria and Klebsiella pneumoniae. 3. The average inhibitory zone was 13.6mm for S. aureus, 14.7mm for S. epidermidis, 12.7mm for B. subtilis, and 13.2mm for S. faecalis at the concentration of $335{\mu}g$ of hyphae of Poria cocos.

  • PDF