• 제목/요약/키워드: MM

Search Result 36,029, Processing Time 0.06 seconds

Impact of Lumen Size and Helical Coil Place Change in Spring on Orthodontic Force (Spring의 lumen size와 helical coil 형성 위치 변화가 교정력에 미치는 영향)

  • Lee, Gyu-Sun;Lee, Sun-Kyoung;Kim, Bok-Dong
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.331-337
    • /
    • 2011
  • Purpose: The purpose of this study was to impact of force system change in finger spring that add helical coil one round on orthodontic force. Methods: The following conclusions were drawn from the experiment conducted after bending 90 samples with a CNC wire forming machine while changing the height and lumen size to 1mm - 3mm - 5mm and 2mm - 3mm - 4mm respectively in the coil of the force system in finger spring added with one wheel of helical coil of 18-8 stainless steel round wire (${\Phi}0.5mm$, spring hard) from Jinsung Co. in domestic market under the following conditions: Laboratory name = Instron 5942; Temperature($deg^{\circ}C$) = 18.00; Humidity(%) = 50.00; Rate 1 = 10.00000 mm/min; Compressive extension = 5.0mm. Results: When Coil height is 1, 3, 5mm and lumen size is 2, 3, 4mm reduce finger spring as mean value of compressive extension occasion maximum load(mN) increases as coil height rises, and lumen size grows to 5.0mm. And was expose that compressive load(mN) increases as coil position of finger spring rises and increase as lumen size is decrescent. Conclusion: As the adherence height of coil was raised from 1mm through 3mm to 5mm, compressive load increased. As the lumen size increased from 2mm through 3mm to 4mm, compressive load decreased. Therefore, these results suggest that it is desirable to lower the coil height and enlarge the lumen size to enhance the biomechanical efficiency of finger spring when manufacturing the finger spring for removable orthodontic devices.

Determination of Transferring Period of Several Plants using Image Processing (영상처리를 이용한 작물의 모종시기 결정)

  • 민병로;김웅;김동우;이대원
    • Journal of Bio-Environment Control
    • /
    • v.13 no.3
    • /
    • pp.178-184
    • /
    • 2004
  • This study carried out to develope the vision system which automatically finds out a optimum transferring period of plants (Perilla, Platycodon grandifloums and Lactuca sativa) by using image process-ing. This system mearsured a height, long diameter and short diameter of the three plants with 20 replications. Following results were obtained on each plant. Compared with real data to be measured by hand with the vernier calipers, height, long diameter and short diameter of Perilla showed 0.5 mm average error rate with 1.7%, 4.7 mm average error rate with 3.9% and 5.5 mm average error rate with 6.9% respectively. Those of Platycodon grandifloums showed 2.4 mm with 8.1%, 3.4 mm with 7.2% and 4.0 mm with 10.4% respectively. Those of Lactuca sativa showed 4.0 mm with 9.1 %,3.4 mm with 7.2% and 3.6 mm with 9.4% respectively. The system could be used to transfer accurately the plant seedling, if the system were improved enough to reduce error rate for the optimum transferring period of a plant in the greenhouse.

A Study on Image Quality and Exposure Dose of Hard-radiation Radiography of the Chest (흉부(胸部) 경선질촬영(硬線質撮影)에 있어서 피폭선양(被曝線量)의 저감(低減)에 관(關)한 연구(硏究))

  • Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakurai, Tatsuya;Kim, Chung-Woon;Hwang, Jong-Sun
    • Journal of radiological science and technology
    • /
    • v.14 no.2
    • /
    • pp.15-21
    • /
    • 1991
  • Experiment was conducted on the image quality and exposure dose following replacement of $CaWO_4$ system screen BH-III and BX-III which have so far been used for high-voltage hard-radiation quality radiography, with rare earth system screen KO750, combined with high contrast film SRH, while additional filter was altered, Cu 0.8 mm+Al 1.4 mm(HVL : Al 8.8 mm), Cu 1.3 mm+Al 1.0 mm(HVL : Al 10.6 mm) and Cu 1.8 mm+Al 1.5 mm(HVL : Al 11.4 mm). AS a result, visual evaluation did not detect extreme changes in image quality under the respective condition(HVL : $Al\;8.8\;mm{\sim}Al\;11.4\;mm$). It was noted, however, that surface exposure dose declined with an increase in the thickness of the additional filter, as it was $18.9\;{\mu}Gy$ at HVL Al 8.8 mm, $17.5\;{\mu}Gy$ at Al 10.6 mm and $15.7\;{\mu}Gy$ at Al 11.4 mm. Considering the limited rating of X-ray equipment and wear of machinery, however, the range of $Cu\;1.3\;mm{\sim}1.8\;mm+Al\;1.0\;mm{\sim}1.5\;mm(1/16\;VL{\sim}1/32\;VL)$ seemed to be a limit.

  • PDF

A STUDY OF DETERMINATION OF PHYSIOLOGICAL ROOT APEX BY ELECTRICAL RESISTANCE VALUE (전기저항치에 의한 생리적 근첨(根尖)의 측정에 관한 연구)

  • Yun, Ki-Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.25-31
    • /
    • 1981
  • One of the most important factors for successful endodontic therapy is an accurate length determination of physiological root apex. Some methods suggested for the measurement of root canal length, include digital-tactile sense and roentgenographic technique with measuring wire, scale and grid. But these methods do not derermine an accurate working length to physiological root apex. Recently electronic measuring devices are used to locate the physiological root apex in root canal length determination and these devices are accepted as an effective apparatus. The 89 patients (116 teeth, 144 canals) among the out-patients of Yonsei University Dental Infirmary, who had had an endodontic treatment in the Department of Operative Dentistry, were measured by the Root-Canal Meter$^{(R)}$ as an electronic device, and radiographs to determine the distribution and location of physiological root apex, then the following results were made: (1) Range of ${\pm}$1mm from the radiographic root apex were present in 88.88% (128 canals) of the subjects. (2) Physiological root apex and radiographic root apex were coincided in 31.94% (46 canals) of the subjects. (3) The actual length of the physiological root apex of the teeth were as follow; A : in the maxillary central incisor : 0.46mm B : in the maxillary lateral incisor : 0.44mm C : in the maxillary canine : 0.44mm D : in the maxillary 1st premolar : a) Buccal : 0.59mm b) Lingual : 0.34mm E : in the maxillary 2nd premolar : 0.54mm F : in the maxillary 1st molar : a) Mesio-buccal : 0.50mm b) Disto-buccal : 0.42mm c) Lingual : 0.56mm G : in the mandibular central incisor : 0.62mm H : in the mandibular lateral incisor : 0.45mm in the mandibular canine : 0.54mm J : in the mandibular 1st premolar : 0.47mm K : in the mandibular 2nd premolar : 0.34mm L : in the mandibular 1st molar : a) Mesio-buccal : 0.54mm b) Mesio-lingual : 0.31mm c) Distal : 0.37mm.

  • PDF

Development on a Relay Lens Type Scope with 70 mm Eye Relief (70 mm Eye Relief를 갖는 릴레이 렌즈 방식 스코프 개발)

  • Park, Seung-Hwan;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.29-35
    • /
    • 2009
  • Purpose: To develop a relay lens type scope with 70 mm eye relief. Methods: By using Sigma 2000 design program, we designed and manufactured a relay lens type scope with 70 mm eye relief, which is integrated after designing an objective part with relay lenses and an eyepiece part, respectively. Results: The characteristics of the relay lens type scope with 70 mm eye relief whch is designed and manufactured by methods, which integrate after respectively designing an object part with relay lenses and an eyepiece part, have the magnification of $+4{\times}$,the length from 1st lens to last lens of about 105 mm, the barrel diameter of 18mm, and the effective diameter of 13 mm. Also we know that the resolution line width is 275 cycles/rad at the 30% MTF value criterion. Conclusions: We could design and manufacture the relay type scope with 70 mm eye relief, the characteristics of which have the magnification of $+4.0{\times}$the MTF above 30% at 275 cycles/rad, and the length from 1st lens to last lens of about 105 mm.

  • PDF

Effects of ponding depth treatment on evapotranspiration in paddy fields (담수심 처리가 논의 증발산량에 미치는 영향)

  • Sohn, Seung-Ho;Park, Ki-Jung;Chung, Sang-Ok
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.9-12
    • /
    • 2002
  • The purpose of this study was to investigate the effects of ponding depth treatment on evapotranspiration in paddy fields. Three poding depth treatments, very sallow, shallow, and deep were used. The experimental plots were three $80m{\times}8m$ rectangular plots. Daily values of rainfall amount, ponding depth, irrigation water, drainage water, evapotranspiration, and infiltration were measured in the field. The ponding depth was continuously observed by observed nstaff during the growing season. The ET was measured by 1m diameter PVC lysimeters. Irrigation water volume was measured by 75 mm pipe flow-meters and the drainage water volume by 75 mm pipe flow-meters and a recording parshall flume. The results showed that irrigation water depths were 688.9 mm, 513.6 mm, and 624.4 mm in 2001, and 356.9 mm, 428.6 mm, and 513.2 mm in 2002 in very shallow, shallow, and deep ponding, respectively. The evapotranspiration were 465.0 mm, 484.1 mm, and 415.1 mm in 2001 and 461.3 mm, 476.3 mm, and 470.6 mm in 2002 in very shallow, shallow, and deep ponding, respectively.

  • PDF

Structural Durability Analysis According to the Thickness of Bicycle Frame Tube (자전거 프레임 튜브 두께에 따른 구조적 내구성 해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.122-129
    • /
    • 2012
  • This study investigates structural and vibration analyses according to the thickness of bicycle frame tube. The model of bicycle frame has the dimension as length of 862mm, width of 100mm and hight of 402.5mm. There are 3 kinds of models with tubes of top, down and seat at bicycle frame as thicknesses of 10, 15 and 20mm. The maximum displacement and stress occur at the center part of seat stay and at the installation part of rear wheel respectively. Maximum displacements become 0.031936, 0.029159 and 0.027984mm in cases of thicknesses of 10, 15 and 20mm respectively. In case of thickness of 20mm among 3 cases, maximum displacement becomes lowest. But maximum stresses become 10.019, 8.5492 and 9.2511MPa in cases of thicknesses of 10, 15 and 20mm respectively. In case of thickness of 15mm among 3 cases, maximum stress becomes lowest. There is no resonance at practical driving conditions and natural frequency remains almost unchanged along the change of thickness. In case of the displacement due to vibration mode, the displacement difference at thickness between 15mm and 20mm becomes 1/2 times than that between 10mm and 15mm. Design at bicycle frame tube becomes most economical and durable effectively in case of thickness of 15mm among 3 cases.

An Evaluation on a calculation the increased cost of construction according to the Depth change of Concrete Slabs in Apartment Building by executing the law of floor impact sound (공동주택 슬래브 두께변화에 따른 공사비 증가 산정 평가 - 바닥충격음 법제화 시행에 따른 표준바닥구조를 중심으로 -)

  • Lee, Won-Yeul;Jeong, Sang-Min;Shin, Duck
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.2 s.16
    • /
    • pp.161-166
    • /
    • 2005
  • This study is to evaluate on the increased cost of construction according to the depth change of concrete slabs in apartment building. When we increased the depth of concrete slab from 150mm to 180, 210mm, the qualitative and cost of construction were calculated by the high-rise type, the unit-size type. As a result of this study, in 32 Pyong type, increment of construction cost rate appeared by $5.1\%$ in case of increase from slab 150mm to 180mm, and $10.0\%$ in case of increase from slab 150mm to 210mm. In 45 Pyong type, Increment of construction cost rate appeared by $5.7\%$ in case of increase from slab 150mm to 180mm, and $10.2\%$ in case of increase from slab 150mm to 210mm. In 55 Pyong type, Increment of construction cost rate appeared by $2.4\%$ in case of increase from slab 150mm to 180mm, and $8.9\%$ in case of increase from slab 150mm to 210mm.

Design of a Broadband Small WLAN Antenna (광대역 소형 WLAN 안테나 설계)

  • Kim, Tae Yong;Lee, Jong-Ig
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.65-67
    • /
    • 2015
  • In this paper, small WLAN antenna was designed and investigated. Proposed antenna was configured for microstrip patch antenna ($29mm{\times}29mm$) that was mounted on RF4 dielectric substrate (relative permittivity 4.4, thick 1.6mm, tangent loss 0.025) with $45mm{\times}45mm$. In order to obtain a wide band characteristic, the cutting process was 3.2mm diagonal corners of the patch antenna located on the top of the substrate. Antenna feeding position for 50 ohm impedance matching was decided to be 5.1mm at the central axis in the horizontal direction. As a result, frequency bandwidth satisfying the condition of VSWR<2dB was 2.365-2.45GHz (85MHz, 3.53%) for considering WLAN.

  • PDF

Optimized Lamina Size Maximizing Yield for Cross Laminated Timber Using Domestic Trees

  • Jeong, Gi-Young;Lee, Jun-Jae;Yeo, Hwan-Myeong;Hong, Jung-Pyo;Kim, Hyung-Kun;So, Won-Tek;Chung, Woo-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.141-148
    • /
    • 2013
  • The goal of this study was to find the optimum lamina size from red pine (Pinus densiflora) and Japanese cedar (Cryptomeria japonica) logs for the cross laminated timber (CLT) production. From visual inspection of the logs from two species, red pine log showed a larger knot and warp compared to the Japanese cedar. Different cross-sectional sizes of lamina ($110mm{\times}30mm$, $110mm{\times}40mm$, $110mm{\times}50mm$, $50mm{\times}30mm$, $30mm{\times}30mm$) from two species were analyzed for yield and grade. Regardless of the species, the optimized cross sectional size for maximizing the yield was $110mm{\times}30mm$. In grading for the different size laminas from Japanese cedar and red pine, a higher percentage of the first and second grade was found from the $110mm{\times}30mm$ lamina cut.